SDR YENA20160705635Stringer Splice · corrodedDURING MAINTENANCE, CORROSION WAS FOUND ON FWD CARGO BAY UNDER FLOOR AREA STRINGER SPLICE ON STRINGER 41L BETWEEN FRAMES 30 - 31. REMOVED AND REPLACED SPLICE.SDR YENA20160705634Door Sill · corrodedDURING MAINTENANCE, CORROSION WAS FOUND ON LEFT AFT CABIN DOOR SILL Y1762 STRINGER 23L FRAMES 66 - 68. REMOVED AND REPLACED THE DOOR SILL.SDR YENA20160705633Web · corrodedDURING MAINTENANCE, CORROSION WAS FOUND ON FWD CARGO BAY UNDER FLOOR AREA DOOR SILL WEB BETWEEN FRAMES 26 - 27 AND STRINGERS 40 - 41R. REMOVED AND REPLACED DOOR SILL WEB.SDR YENA20160705632Threshold · corrodedDURING MAINTENANCE, CORROSION WAS FOUND ON AFT CARGO BAY DOOR THRESHOLD AROUND TIE-DOWN FITTINGS AT FRAMES 53, 54, 55, 56. REMOVED AND REPLACED AFT CARGO BAY DOOR THRESHOLD.SDR YENA20160705631Shear Tie · corrodedDURING MAINTENANCE, CORROSION WAS FOUND ON FWD CARGO BAY UNDER FLOOR AREA SHEAR TIE PLATE ON FRAME 28 AND CENTER STRINGER. REMOVED AND REPLACED SHEAR TIE.SDR YENA20160705630Floorbeam · corrodedDURING MAINTENANCE, CORROSION WAS FOUND ON LEFT AFT CABIN FLOORBEAM Y1292, 1" FWD OF FRAME 68. REMOVED AND REPLACED THE FLOORBEAM.SDR YENA20160705629Shear Tie · corrodedDURING MAINTENANCE, CORROSION WAS FOUND ON SHEAR TIE FRAME 28 AND STRINGER 43L. REMOVED AND REPLACED THE SHEAR TIE .SDR YENA20160705628Floor Support · corrodedDURING MAINTENANCE, CORROSION WAS FOUND ON RT AFT CABIN FLOOR SUPPORT BETWEEN FRAMES 68-69. REPLACED THE FLOOR SUPPORTSDR YENA20160705627Floorbeam · corrodedDURING MAINTENANCE, CORROSION WAS FOUND ON MAIN CABIN FLOORBEAM Y765 AT FRAME 69. REMOVED AND REPLACED MAIN CABIN FLOORBEAM.SDR YENA20160705626Door Sill · corrodedDURING MAINTENANCE, CORROSION WAS FOUND ON RT AFT PASS DOOR SILL FRAME 68. REMOVED CORRODED REPAIR. FABRICATED AND INSTALLED NEW REPAIR.SDR YENA20160705625Shear Web · corrodedDURING MAINTENANCE, CORROSION WAS FOUND ON RT CABIN FLOOR SHEAR WEB AND CHANNEL 8 INCHES FWD OF FRAME 70. REPLACED THE SHEAR WEB AND CHANNEL SUPPORT.SDR YENA20160705624Floorbeam · corrodedDURING MAINTENANCE, CORROSION WAS FOUND ON THE LEFT AFT CABIN FLOORBEAM AT Y765, 2" FWD OF FRAME 66. REPLACED THE FLOORBEAM.SDR YENA20160705623Shear Web · corrodedDURING MAINTENANCE, CORROSION WAS FOUND ON THE LEFT AFT CABIN FLOOR SHEAR WEB AND CHANNEL, 8 INCHES FWD OF FRAME 70. REPLACED THE SHEAR WEB AND CHANNEL SUPPORT.SDR YENA20160705622Dummy Rail · corrodedDURING MAINTENANCE, FOUND CORROSION ON DUMMY RAIL AT Y765-10' CORRODED AT FRAMES 64 - 66. REPLACED THE DUMMY RAIL.SDR YENA20160705621Floorbeam · corrodedDURING MAINTENANCE, CORROSION WAS FOUND ON FLOORBEAM AT -Y254, FRAME 17 TO FRAME 18, STR 23R. REPLACED FLOORBEAM.SDR GTIA2016070401503Bottle · low pressureR1 DOOR ASSIST BOTTLE REQUIRES NITROGEN SERVICING. SERVICED R1 DOOR WITH NITROGEN IAW AMM 52-10-00-614-001-A.SDR GTIA2016070401502Oxygen Mask · unwanted deployON LANDING, OXYGEN MASKS OVER ROW 11 ABC DROPPED. REPLACKED OXYGEN MASKS AND SECURED DOOR IAW AMM 35-21-43-550-802-ASDR AALA201607049002Sign · unsecureEXIT SIGN ON DIVIDER BETWEEN FIRST CLASS COACH NEEDS REPAIRED. REINSTALLED EXIT SIGN ON DIVIDER BETWEEN FIRST CLASS AND COACH.SDR YENA20160702620Servo Control · failedDECLARED EMERGENCY, WHEEL N/W STEERING FAULT WHILE IN FLIGHT. RESET N/W STEERING SWITCH TWICE IN FLIGHT AND ONCE ON GROUND, WOULD NOT FUNCTION NORMALLY. R & R N/W STEERING SERVO CONTROL, 6GC, IAW AMM 32-51-51. OPS CHECK GOOD, NO DEFECTS AND LEAKS NOTED AT TSDR CALA2016070895504Stringer · corrodedSTRINGER 41L CORRODED IN AFT CARGO BETWEEN FRAMES 52 AND 53. REMOVED CORROSION AND REPAIRED THE STRINGER IAW SRM 53-00-13 PARA 4B FIG 202 SHEET 5.SDR CALA2016070895503Keelbeam · damagedWHILE ACCOMPLISHING FCD 5330-05575 REV.B, THE L11 HOLE THROUGH THE KEEL BEAM SIDE WALL STRUCTURAL LAYERS WAS FOUND DAMAGED. REPAIRED IAW ECRA 5330-05745.SDR AALA201607029003Connector · defectiveACFT WAS GROUNDED: ON DECENT THROUGH 10,000, F/A ALERTED US TO THE ELECTRICAL ODOR IN AFT CABIN, ISOLATED TO C/B PANEL, DECLARED AN EMERGENCY, UNEVENTFUL LANDING WITH EMERGENCY EQUIPTMENT. MAINTENANCE ISOLATED TO COFFEEMAKER J-11 CONNECTOR PLUG CONNECTOR. REPSDR CALA2016070195498Skin · crackedFUSELAGE BUTT JOINT AREA AT FRAME 35 STINGER 30L CRACKED. REPAIRED IAW ECRA 5330-05742 REV- PART 1.SDR GTIA2016063001496Container · inoperativeROW 15 ABC OXYGEN MASK DID NOT DEPLOY DURING DROP CHECK. R & R EMERGENCY OXYGEN CONTAINER IAW AMM 35-21-41. DROP TEST GOOD.SDR CALA2016070195502Pump · leakingGREEN RESERVOIR LOW LEVEL TO NEAR ZERO DISPLAYED ON ECAM. FOUND NR 1 HYDRAULIC PUMP LEAKING, REPLACED PUMP, OPS GOODSDR AALA201607049004Master Switch · defectiveAIRCRAFT WAS GROUNDED: DURING TAXI OUT ANOTHER AIRCRAFT REPORTED FIRE / FLAMES COMING FROM THE APU EXHAUST. THE FIRE DEPARTMENT EXTINGUISHED FLAMES AND THE AIRCRAFT SAFELY RETURNED TO THE GATE. APU HAD BEEN SHUT DOWN AFTER ENGINE START SEVERAL MINUTES EARLIER.SDR AALA201607049003Shutoff Valve · failedAIRCRAFT WAS GROUNDED: DURING TAXI OUT ANOTHER AIRCRAFT REPORTED FIRE / FLAMES COMING FROM THE APU EXHAUST. THE FIRE DEPARTMENT EXTINGUISHED FLAMES AND THE AIRCRAFT SAFELY RETURNED TO THE GATE. APU HAD BEEN SHUT DOWN AFTER ENGINE START SEVERAL MINUTES EARLIER.SDR AALA201606309001Fuel Control · defectiveDURING TAXI OUT ANOTHER AIRCRAFT REPORTED FIRE / FLAMES COMING FROM THE APU EXHAUST. AIRCRAFT WAS GROUNDED. THE FIRE DEPARTMENT EXTINGUISHED FLAMES AND THE AIRCRAFT SAFELY RETURNED TO THE GATE. APU HAD BEEN SHUT DOWN AFTER ENGINE START SEVERAL MINUTES EARLISDR CALA2016070195495Stringer Splice · corrodedFWD CARGO STRINGER 43L SPLICE JUST FWD OF FRAME 31 HAS CORROSION REMOVED THE STRINGER SPLICE AND FOUND DEFECTS AFTER REMOVING CORROSION, RECEIVED NEW STRNGR SPLICE AND INSTALLED IAW SRM 51-42-11.SDR CALA2016070195491Tire · vibrationNOSE GEAR HAS STRONG VIBRATION ON ROTATION AND RETRACTION :REPLACED BOTH NOSE TIRES IAW AMM 32-41-12-400-001-A.SDR CALA2016070195494Stringer Splice · corrodedFWD CARGO BAY, STRINGER 41L SPLICE JUST FWD OF FRAME 31 HAS CORROSION REMOVED AND REPLACED THE STRINGER IAW SRM 51-42-11.SDR CALA2016070195490Door Sill · corrodedAFT CABIN R2 DOOR SILL CORRODED AT FRAME 68. FOUND OUT OF LIMITS SRM 53-41-14. R & R THE R2 DOOR SILL & ATTACHING PARTS IAW SRM 51-72-11.SDR YENA20160628617Connector · backed outDURING ROUTINE MAINTENANCE, OVERHEAD EMERGENCY LIGHT AT ROW 18 WAS FOUND TO BE INOPERATIVE. FOUND THAT CONNECTOR HAD BACKED OFF FROM CONNECTION POINT. RECONNECTED WIRES AND PERFORMED OPS CHECK. OPS CHECK PASSED.SDR CALA2016081195626Battery Pack · no testEMERGENCY LIGHT TEST FAILED WITH EPSU BATTERY FWD LEFT FAULT. REPLACED EPSU BATTERY, OPS CHECKED NORMAL.SDR YENA20160626600Floorbeam · corrodedLT FLOORBEAM CORRODED AT FRAME 66; STR 23L. REPLACED FLOORBEAM IAW SRM REF 51-42-11 REF NR 440322-32307.SDR YENA20160626599Door Sill · corrodedL2 DOOR SILL CORRODED AROUND FASTENER HOLES FWD OF FRAME 66. REPAIRED IAW SRM REF 53-41-14, INSTALLED 2EA ANGLES REF NR 440322-32242.SDR YENA20160626598Floorbeam · corrodedAFT CABIN RT SIDE FLOORBEAM -Y765 CORRODED AT FR 66+14". REPLACED BEAM IAW SRM REF 51-72-11, REF NR 440322-32200.SDR YENA20160626597Floorbeam · corrodedAFT CABIN FLOORBEAM CORRODED AT FRAME 67 AND 67+10 ; Y765. REPLACED BEAM IAW SRM REF 51-72-11, REF NR 440322-32199.SDR YENA20160626596Door Sill · corrodedL2 DOOR SILL CORRODED AROUND FASTENER HOLE FRAME 68. REPAIRED SILL IAW SRM REF 53-41-14 REF NR 440322-32194.SDR YENA20160626595Floorbeam · corrodedAFT CABIN FLOORBEAM, Y1292 CORRODED AT FRAME 67 + 18". REPLACED BEAM IAW SRM REF 51-42-11 REF NR 440322-32197.SDR YENA20160626594Floorbeam · corrodedAFT CABIN FLOORBEAM Y1291, CORRODED AT FRAME 66. REPLACED BEAM IAW SRM REF 51-42-11, REF NR 440322-32195.SDR YENA20160626593Floorbeam · corrodedAFT CABIN FLOORBEAM Y1292, CORRODED AT FRAME 67. REPLACED BEAM IAW SRM REF 51-42-11, REF NR 44322-32196.SDR CALA2016062895488Cleat · corrodedCLEAT AT FRAME 33, IN FORWARD BETWEEN STR 43R, HAS CORROSION. R & R CLEAT AT FRAME 33, STR 43L IAW SRM 51-42-11.SDR AALA201606269001Power Supply · inoperativeAIRCRAFT WAS NOT GROUNDED: EMERGENCY EXIT SIGNS DO NOT LIGHT UP AT AFT L2 AND R2 DOORS. REPLACED EMERGENCY POWER SUPPLY UNIT 13WL AND ACCOMPLISHED A SATISFACTORY OPS CHECK IAW AMM 33-51-38.SDR CALA2016081195638Light · malfunctionedRIGHT WING EMERGENCY LIGHT CAME ON DURING LANDING RESET CIDS, LIGHTS CHECKED GOOD.SDR YENA20160624591Power Supply · failedEMERGENCY EXIT ROW 19, 23, 15 LIGHTS OUT. R & R EPSU AND BATTERY IAW AMM 33-51-38.SDR YENA20160624590Battery · dischargedEMERGENCY EXIT ROW 19, 23, 15 LIGHTS OUT. R & R EPSU AND BATTERY IAW AMM 33-51-38.SDR AALA201606259002Feeder Cable · chafedAIRCRAFT WAS GROUNDED: TOP INBD FEEDER CABLE CHAFED ABOUT 6" FORWARD OF PRECOOLER FIREWALL ON OTBD OF NR 2 ENGINE PYLON. REPAIRED WIRE 2422-4513 IAW ESPM 20-53-21.SDR AALA201606249004Feeder Cable · chafedAIRCRAFT WAS GROUNDED. NR 2 EINGINE TOP MIDDLE FEEDER CABLE WIRE CHAFED ABOUT 6" FORWARD OF PRECOOLER FIRE WALL. PERFORMED PERMANENT REPAIR ON MIDDLE FEEDER WIRE IAW 20-53-21.SDR CALA2016081195636Power Supply · no testEPSU UNIT FWD LT MESSAGE 10WL DURING TEST. REPLACED FWD LEFT EPSU IAW AMM. OPS CHECKED NORMAL
Back to Airbus A320-232