Airbus A320-232
Service difficulty reports · 32,653
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A320232' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A320232' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2016081195634Slide · no testCIDS CABIN CHECK, FAULTS LEFT AFT EXT LOADS REPLACED THE LEFT AFT SLIDE PACKSDR CALA2016081195635Module · no testLEFT AFT EMERGENCY LIGHT MODULE FAULT RESET THE MODULE, OPS CHECKED GOODSDR AALA201606229010Floor Panel · delaminatedAIRCRAFT WAS NOT GROUNDED. AFT CARGO FLOOR PANEL 151NF DELAMINATED. REPLACED FLOOR PANEL 151NF IAW AMM 53-42-17.SDR AALA201606229009Floor Panel · delaminatedAIRCRAFT WAS NOT GROUNDED. AFT CARGO FLOOR PANEL 151EF DELAMINATED. REPLACED AFT CARGO FLOOR PANEL 151EF IAW AMM 53-42-17.SDR YENA20160621589Skin Panel · corrodedDURING MAINTENANCE, CORROSION WAS DISCOVERED ON OVERHANG T/E LOCATED AT RIB 16, TOP SKIN PANEL 2, LOWER SURFACE ON RT WING. PERFORMED PERMANENT REPAIR ON OVERHANG T/E LOCATED AT RIB 16, TOP SKIN PANEL 2, LOWER SURFACE ON RT WING.SDR YENA20160621588Skin Panel · corrodedDURING MAINTENANCE, CORROSION WAS DISCOVERED ON OVERHANG T/E LOCATED AT RIB 17 TOP SKIN PANEL 2 LOWER SURFACE ON RT WING. PERFORMED PERMANENT REPAIR ON OVERHANG T/E.SDR YENA20160621587Skin Panel · corrodedDURING MAINTENANCE, CORROSION WAS DISCOVERED ON OVERHANG T/E AT RIB 15 + 8", TOP SKIN PANEL 2, LOWER SURFACE ON LT WING. PERFORMED PERMANENT REPAIR ON OVERHANG T/E AT RIB 15 + 8", TOP SKIN PANEL 2 ON LT WING.SDR YENA20160621586Skin Panel · corrodedDURING MAINTENANCE, CORROSION WAS DISCOVERED ON OVERHANG T/E LOCATION AT RIB 16 TOP SKIN PANEL 2, LOWER SURFACE ON LT WING. PERFORMED PERMANENT REPAIR ON OVERHANG T/E LOCATED AT RIB 16, TOP SKIN PANEL 2, ON LT WING.SDR YENA20160621585Skin Panel · corrodedDURING MAINTENANCE, CORROSION WAS DISCOVERED ON OVERHANG T/E LOCATION AT RIB 15, TOP SKIN PANEL 2 LOWER SURFACE ON LT WING. PERFORMED PERMANENT REPAIR ON OVERHANG T/E LOCATED AT RIB 15, TOP SKIN PANEL 2 ON LT WING.SDR YENA20160621584Skin · corrodedDURING MAINTENANCE, CORROSION WAS DISCOVERED ON TOP SKIN ON UPPER SURFACE ON LT WING ON RIB 1 AND STR 11. REPAIRED AREA ON TOP SKIN UPPER SURFACE ON LT WING ON RIB 1 AND STR 11.SDR YENA20160621583Skin · corrodedDURING MAINTENANCE, CORROSION WAS DISCOVERED ON TOP SKIN ON UPPER SURFACE LEVEL STR 11, BETWEEN RIB 11 AND RIB 12, LEFT WING. REPAIRED AREA ON TOP SKIN UPPER SURFACE LEVEL STR 11, BETWEEN RIB 11 AND RIB 12 LT WING.SDR YENA20160621582Door Sill · corrodedDURING MAINTENANCE, CORROSION WAS DISCOVERED ON LOWER SILL, LOCATION: FRAME 66, STR 23L AT AFT GALLEY AREA; INSTALLED NEW LOWER SILL LOCATION, FRAME 66 AT LEVEL STR 23L AT AFT GALLEY AREA.SDR YENA20160621581Door Sill · corrodedDURING MAINTENANCE, CORROSION WAS DISCOVERED ON LOWER SILL LOCATION, FRAME 66, STR 23R AT AFT GALLEY AREA. R & R NEW LOWER SILL.SDR YENA20160621580Door Sill · corrodedDURING MAINTENANCE, CORROSION WAS DISCOVERED ON LOWER SILL LOCATION, FRAME 68, STR 23R AT AFT GALLEY AREA. R & R LOWER SILL.SDR YENA20160621579Floorbeam · corrodedDURING MAINTENANCE, CORROSION WAS DISCOVERED ON FLOORBEAM LOCATION: -Y1162, LOCATION FRAME 67 + 18" AT AFT GALLEY AREA; R & R FLOORBEAM -Y1162, FR 67 +18" AT AFT GALLEY AREA.SDR YENA20160621578Floorbeam · corrodedDURING MAINTENANCE, CORROSION WAS DISCOVERED ON FLOORBEAM LOCATION: -Y1162, FR 67 +15" AT AFT GALLEY AREA. R & R FLOORBEAM -Y1162, FRAME 67 + 15" AT AFT GALLEY AREA.SDR YENA20160621577Floorbeam · corrodedDURING MAINTENANCE, CORROSION WAS DISCOVERED ON FLOORBEAM LOCATION: -Y1292 BETWEEN FRAME 16 TO FRAME 20 AT FWD GALLEY AREA. R & R
FLOORBEAM AT FWD GALLEY AREA.SDR YENA20160621576Floorbeam · corrodedDURING MAINTENANCE, CORROSION WAS DISCOVERED ON FLOORBEAM, +Y1292 BETWEEN FRAME 16 TO FRAME 20 AT FWD GALLEY AREA. REPLACED FLOORBEAM +Y1292 BETWEEN FRAME 16 TO FRAME 20 AT FWD GALLEY AREA.SDR YENA20160621575Floorbeam · corrodedDURING MAINTENANCE, CORROSION WAS DISCOVERED ON FLOORBEAM, -Y765 BETWEEN FRAME 20 TO FRAME 24 AT FWD GALLEY AREA. R & R FLOORBEAM -Y765 BETWEEN FRAME 20 TO FRAME 24 AT FWD GALLEY AREA.SDR YENA20160621574Floorbeam · corrodedDURING MAINTENANCE, CORROSION WAS DISCOVERED ON FLOORBEAM, LOCATION: -Y254, FRAME 20 AT FWD GALLEY AREA; R & R FLOORBEAM -Y254, FRAME 20 AT FWD GALLEY AREA.SDR YENA20160621573Floorbeam · corrodedDURING MAINTENANCE, CORROSION WAS DISCOVERED ON THE FLOORBEAM, LOCATION: +Y1162, FRAME 67+18" AT AFT GALLEY AREA. R & R FLOORBEAM Y1162 FRAME 67 + 18" AT AFT GALLEY AREA IAW SRM 51-72-11.SDR AALA201606219004Fillercap · leakingAIRCRAFT WAS GROUNDED. WHEN EXTERNAL AIR WAS REMOVED AND APU BLEED AND PACK 1+2 COOLING A/C AT GATE, A STRONG DIRTY SOX ODOR WAS OVERWHELMING. MAINTENANCE DETERMINED THAT THE SOURCE OF THE ODOR WAS THE APU AND WAS PLACED ON MEL. MAINTENANCE FOUND EVIDENCE OSDR CALA2016062295471Frame · damagedFRAME SECTION AT FRAME 67, STR 23R-30R HAS SEVERAL OUT OF ROUND HOLES AT DOOR SILL ATTACH POINT. REMOVED FRAME SECT AT FRAME 67, OUTER ROUND HOLES NEW FRAME LOCATED DRILLED AND INSTALLED.SDR CALA2016062295470Cleat · corrodedFRAME CLEAT AT FRAME 67, STR 23R-26R HAS SEVERAL OUT OF ROUND HOLES AT DOOR SILL ATTACH POINT. REMOVED FRAME 67 CLEAT AT STR 23-24R OUTER ROUND HOLES FAB CLEAT IAW SRM 53-41-12.SDR YENA20160620570Epsu · failedVARIOUS EMERGENCY LIGHTS WERE REPORTED AS INOPERATIVE. R & R ESPU AT FIN 11WL. REPLACED IAW AMM 33-51-38. OPS CHECK PERFORMED AND PASSED. ALL LIGHTS NOW OPERATIONAL.SDR CALA2016081195628Connector · looseEMERGENCY LIGHT TEST FAILED. MESSAGE EPSU EXT LOAD FWD L. RESEATED EPSU CONNECTOR, REPLACED BATTERY.SDR AALA201606209010Power Supply · failedAIRCRAFT IN BASE MAINTENANCE, EMERGENCY POWER SUPPLY UNIT 10WL FAILED FUNCTIONAL TEST AND WAS REPLACED IAW AMM 53-51-38-400-001-A. A SATISFACTORY OPS CHECK WAS ACCOMPLISHED.SDR CALA2016062295469Cleat · corrodedFWD PIT AT FRAME 29, STR 42L-STR 43L CLEAT HAS CORROSION. R & R CORRODED CLEAT ON FWD CARGO FRAME 29, STR 42L-43L, SRM 51-42-11.SDR CALA2016062295467Shear Tie · corrodedFWD PIT SHEAR TIE AT FRAME 31 BETWEEN DTR 43R-43L HAS CORROSION. R & R CORRODED SHEAR TIE ON FWD CARGO FRAME 31 STR 43R-43L IAW SRM 51-42-11.SDR AALA201606209007Valve · defectiveAIRCRAFT WAS NOT GROUNDED. FLIGHT CREW REPORTED A VENT SKIN AIR VALVE FAULT OCCURRED DURING TAKEOFF, BETWEEN 30-40 KNOTS AND THE TAKEOFF WAS ABORTED. MAINTENANCE REPLACED THE SKIN AIR OUTLET VALVE AND ACCOMPLISHED A SATISFACTORY OPS CHECK IAW AMM 21-26-53.SDR GTIA2016061901486Oxygen Mask · brokenCAPTAINS OXYGEN MASK INFLATION RED GRIP IS CRACKED. R & R CAPTAIN`S OXYGEN MASK IAW AMM 35-12-41. NO LEAKS NOTED.SDR YENA20160619551Switch · failedPILOT REPORTED EMERGENCY LIGHTS CAME ON AFTER 2ND ENGINE START. REPLACED EMERGENCY LIGHT ARM SWITCH, TOGGLE, 4WL IAW AMM 33-51-08. PERFORMED OPS CHECK AND ENGINE RUN. NO FAULTS FOUND.SDR CALA2016081195622Light · malfunctionedNUMEROUS CIDS PA LIGHTS INTERMITTENT. CABIN LIGHTS TO FULL BRIGHT ON T/O. BITE CHECK OF CIDS SYSTEM AND OPS CHECKS OF LIGHTS ALL CHECK GOOD. OK TO CONT.SDR CALA2016062295464Power Supply · inoperativeWITH EMERGENCY LIGHT SWITCH IN ARMED MODE AND LOSS OF ACFT POWER, EMERGENCY LIGHTS DO NOT COME ON IN THE CABIN AND OVERWING. REPLACED EMERGENCY POWER SUPPLY AND BATTERY AT DOOR 1L. OPS CK GOOD.SDR CALA2016062295463Power Supply · inoperativeON 2 SERVICE CHECKS, EMERGENCY LIGHTS TEST FAIL WITH FOLLOWING MSG, EXT LOADS EMERGENCY RT BATTERY, EMERGENCY RT AND UNIT EMERGENCY LT. REPLACED DOOR 2L LIGHT POWER SUPPLY AND BATTERY OPS CHECK GOOD.SDR CALA2016081195637Battery Pack · no testEMERG LIGHTS MESSAGE. EXT LOADS EMER R, BATT EMER R, EMER L REPLACED RIGHT OVERWING EPSU & BATTERYSDR AALA201606249009Access Panel · damagedAIRCRAFT IN BASE MAINTENANCE, RT WING FUEL TANK ACCESS PANEL 650CB HAS ELONGATED FASTENER HOLE. REPLACED RT WING FUEL TANK ACCESS PANEL 650CB IAW TASK CARD 26C60057181.SDR CALA2016061795460Power Supply · inoperativeEMERGENCY BATTERY CAPACITY TEST FAILED DUE TO LT BATTERY MSG 33-51-38. REPLACED EEL POWER SUPPLY AT DR1L, 10WL. OPS CK GOOD.SDR CALA2016081195624Battery Pack · no testEPSU BATTERY EMER L SHOWN DURING TEST. REPLACED LEFT EMERGENCY EPSU BATTERY. OPS CHK GOODSDR CALA2016081195633Light · malfunctionedEXIT LIGHT AT L1 DOOR, OPERATES INTERMITTENTLY. OPS TEST OF THE EMERGENCY LIGHTS CHECKED OK IAW AMM.SDR CALA2016081195632Power Supply · no testTEST FAIL MESSAGE, EMERGENCY LIGHT. REPLACED THE BATTERY AND EPSU, OPS TESTED OKSDR CALA2016081195623Battery Pack · no testEPSU UNIT FWD L SHOWN DURING TEST. REPLACED FWD EPSU BATTERY, OPS CHECKED GOODSDR CALA2016061795462Director · faultyON CLIMB, CONTINUOUS EVAC HORN, AND CI DS 1 & 2 FAULTS ON ECAM. REPLACED 1 & 2 CIDS DIRECTORS REF AMM 23-73-34-400, NO FAULTS AT THIS TIME.SDR AALA201606159008Slide · defectiveAIRCRAFT WAS GROUNDED: L1 DOOR HAS WRONG BUSTLE ON DOOR SLIDE. UNABLE TO CLOSE DOOR. REPLACED L1 DOOR SLIDE BUSTLE IAW AMM 25-62-50.SDR AALA201606159007Lens · missingAIRCRAFT WAS NOT GROUNDED: R2 DOOR EMERGENCY EXIT LENS MISSING. INSTALLED EMERGENCY EXIT LIGHT LENS.SDR AALA201606159006Light · crackedPASSENGER-CREW DOOR 841 SLIDE ARMED INDICATOR LIGHT CRACKED. REPLACED SLIDE ARMED INDICATOR LIGHT AND ACCOMPLISHED A SATISFACTORY OPS CHECK IAW AMM 52-73-21-400-001-A AND 52-73-710-001-A.SDR AALA201606149008Pin · wornLEFT MLG RETRACTION ACTUATOR ATTACHMENT LUG PIN HAS WEAR. REPLACED PIN IAW AMM 32-31-46-400-001-A.SDR AALA201606149011Cowling · departedRETURNED TO DEPARTURE; AIRCRAFT WAS GROUNDED: THE NR 2 ENGINE INBD COWLING CAME OFF OF THE ACFT AFTER TAKEOFF. NO ABNORMAL ENGINE INDICATIONS OR ABNORMAL FLIGHT CHARACTERISTICS WERE NOTED BY THE FLIGHT CREW AND THE ACFT RETURNED TO DEPARTURE WHERE THE ACFT SDR CALA2016081195631Light · malfunctionedEMERGENCY EXIT LIGHTS WILL NOT EXTENGUISH. CYCLED POWER, LIGHT OPS NORMALSDR CALA2016081195630Power Supply · no test13WL EPSU FAILED LIGHT CHECK. REPLACED THE EPSU, OPS CHECKED GOOD.
Back to Airbus A320-232