Airbus A320-232
Service difficulty reports · 32,653
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A320232' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A320232' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA201505129010Floor Panel · delaminated3S CHECK, FLOOR PANEL 262BG DELAMINATED IN AFT GALLEY. REPLACED FLOOR PANEL IAW SRM 53-02-00 PAR 8H FIG 209 & IRM 9701 REV G.SDR AALA201505129008Floor Panel · delaminated3S CHECK, FLOOR PANEL 261DF DELAMINATED IN AFT GALLEY AREA. REPLACED FLOOR PANEL IAW JC 26C26053014.SDR AALA201505129006Floor Panel · delaminated3S CHECK, FLOOR PANEL 251LG, DELAMINATED IN AFT GALLEY AREA. REPLACED FLOOR PANEL WITH REPLACEMENT MATERIAL IAW SRM 53-02-00 PAR 8 H FIG 209 & IRM 9701 REV G.SDR AALA201505129004Floor Panel · delaminated3S CHECK, FLOOR PANEL 252LG DELAMINATED IN AFT GALLEY AREA. REPLACED FLOOR PANEL WITH REPLACEMENT MATERIAL IAW SRM 53-02-00 PAR 8 H FIG 209 & IRM 9701 REV G.SDR AALA201505059002Floor Panel · delaminated3S CHECK, FLOOR PANEL 261PF DELAMINATED IN AFT GALLEY. REPLACED FLOOR PANEL IAW SRM 53-02-00 PARAGRAPH 84 FIGURE 209 & IRM 97-01 REV G.SDR AALA201504289020Floor Panel · delaminated3S CHECK, CABIN FLOOR PANEL 252QH DELAMINATED. REPLACED IAW SRM 53-02-00 & IRM 9701 REV G.SDR AALA201504289019Floor Panel · delaminated3S CHECK, AFT GALLEY FLOOR PANEL 261BG DELAMINATED. REPLACED IAW SRM 53-02-00 & IRM 9701 REV G.SDR AALA201504289017Floor Panel · delaminated3S CHECK, CABIN FLOOR PANEL 252KF DELAMINATED. REPLACED IAW SRM 53-02-00 & IRM 9701 REV G.SDR AALA201504289016Floor Panel · delaminated3S CHECK, CABIN FLOOR PANEL 252EF DELAMINATED. REPLACED PANEL IAW SRM 53-02-00 & IRM 9701 REV G.SDR AALA201504289015Floor Panel · delaminated3S CHECK, CABIN FLOOR PANEL 252QF DELAMINATED. REPLACED IAW SRM 53-02-00 & IRM 9701 REV G.SDR AALA201504149004Light · missing7X EMERGNECY EXIT LIGHT MISSING. REPLACED MISSING EMERGENCY LIGHT AS REQUIRED.SDR AALA201504109005Pump · failedFLT 504 EN-ROUTE, WHILE IN CRUISE FLIGHT, THE ACFT EXPERIENCED A GREEN HYD SYS OVERHEAT WARNING, FOLLOWED BY A GREEN HYD ENG 1 PUMP LOW PRESS FAULT, THEN A PTU FAULT. AS A PRECAUTION, THE FLIGHT DIVERTED. THE FLIGHT CREW DECLARED AN EMER. THE FLIGHT LANDED SDR AALA201504109012Floor Panel · delaminatedAFT CARGO FLOOR PANEL 151LF DELAMINATED. REPAIRED AFT CARGO FLOOR PANEL 151LF IAW SRM 53-02-00-201 & EA 250047.SDR AALA201504089004Fmu · inoperativeAFTER TAKEOFF, THE CREW RECEIVED A NR 2 FUEL CONTROL FAULT. DEFERRING TO THE QRH, WHICH TOLD THEM TO PULL ENG BACK TO IDLE. PROCEDURE WAS FOLLOWED, BUT THE SAME ISSUE WAS ACTIVE. THE FLIGHT WAS DIVERTED, AN EMERGNECY WAS DECLARED. RECEIVED AN NR 2 ENG ADSDR AALA201504089003Pressure Switch · leakingNOTICED A DIRTY SOCK SMELL IN COCKPIT & AFT CABIN, TAKEOFF POWER & CLIMB. FLIGHT ATTENDANTS NOTICED IT FOR LAST 5 MIN OF FLIGHT IN ENTIRE CABIN. INSPECTED ACFT IAW 26L00021001 & 26L00021003. NO EXTERNAL LEAKAGE SOURCES NOTED FROM ENGS OR EXTERNAL FUSELAGE ASDR GTIA2015040401548Oxygen Mask · unsecure18 DEF, O2 MASK PARTIALY DEPLOYED. FOUND O2 MASK NOT TO BE DEPLOYED. RESECURED PANEL BEHIND PSU IAW AMM 25-23-00.SDR USAA2015040300006Light · inoperativeEMERGENCY ESCAPE PATH LIGHT AT SEAT 22C DOES NOT ILLUMINATE. REPLACED LIGHT AT SEAT 22C. OPERATIONAL CHECKED WITH NO DEFECTS NOTED.SDR YENA20150402069Power Supply · failedON MAINTENANCE CHECK FOUND EMERGENCY LIGHT HAD TEST FAULT EPSU BATTERY EMERGENCY. R & R EPSU 12WL IAW AMM 33-51-38-000-001-A PARA 4.A, 33-51-38-400-001-A PARA 4.A, 33-51-38-860-052-A STEP C & D. OPS CHECKED GOOD.SDR YENA20150402068Power Supply · failedFLT 6454 , ON MAINTENANCE CHECK FOUND EMERGENCY LIGHT TEST FAULT EPSU BATTERY EMERGENCY AFT L. R & R EPSU 13WL IAW AMM 33-51-38-000-001-A, PARA 4 A, 33-51-38-400-001-A, PARA 4.A, 33-51-38-740-050-B. OPS CHECKED GOOD.SDR USAA2015040200021Door Sill · corrodedCORROSION ON LOWER SILL BULK CARGO DOOR BETWEEN FRAME 60 - 62, 5 POINTS. REPAIRED LOWER SILL BULK CARGO DOOR BETWEEN FRAME 60 - 62 IAW SRM 53-41-49 FIGURE 203 & SRM 53-41-49-2-001-00.SDR USAA2015040200012Battery · faultyAFT GALLEY EMER LIGHT UNIT INDICATES INTERNAL LIGHT FAULT & EXTERIOR LIGHT FAULT. REPLACED AFT GALLEY EMER LIGHT BATTERY IAW AMM 33-51-38-040.SDR USAA2015040200005Light · inoperativeEMERGENCY EXIT LIGHTS SEAT ROW 1 & 4 LT INOPERATIVE. INSTALLED SEAT ROW 1 LT IAW CMM 25-40-06 & INTERIOR ARRANGEMENT DOC 12F-138Y. OPERATIONS CHECK OF SEAT MOUNTED EXIT LIGHTS GOOD.SDR USAA2015040200011Solenoid Valve · faultyON TAKEOFF AT ABOUT 1500 FT, CREW HAD NR 2 ENG COMPRESSOR STALL & HIGH EGT. FLIGHT RETURNED TO FIELD WITH NO EMER DECLARED & WITH NO FURTHER INCIDENT. TROUBLE SHOT IAW TSM 71-00-00-810-809A & PERFORMED FUNCTIONAL CHECK OF THE HPC 7TH & 10TH STAGE BLEED VLV &SDR USAA2015040200010Bleed Valve · faultyON TAKEOFF AT ABOUT 1500 FT, CREW HAD NR 2 ENG COMPRESSOR STALL & HIGH EGT. FLIGHT RETURNED TO FIELD WITH NO EMER DECLARED & WITH NO FURTHER INCIDENT. TROUBLE SHOT IAW TSM 71-00-00-810-809A & PERFORMED FUNCTIONAL CHECK OF THE HPC 7TH & 10TH STAGE BLEED VLV &SDR USAA2015040200007Power Supply · inoperativeCABIN EMER LIGHT POWER SUPPLY INOPERATIVE AT RT OVERWING EXIT. R & R POWER SUPPLY IAW AMM 33-51-38-0401.SDR USAA2015040200006Power Supply · faultyAFT GALLEY EMER LIGHT UNIT INDICATES INTERNAL & EXTERIOR LIGHT FAULT. R & R EPSU IAW AMM 33-51-38-040 00 WITH GOOD OPERATIONAL CHECK.SDR YENA20150331070Power Supply · failedON MAINTENANCE CHECK FOUND EPSU 11WL UNIT FAULTED. EMERGENCY PATH LOW LEVEL LIGHTS INOPERATIVE EVERY OTHER SEAT. R & R EPSU 11 WL IAW AMM 33-51-38. OPS CHECK GOOD.SDR USAA2015040100004Battery · dischargedEMERGENCY LIGHT IN LT FWD PARTITION INOPERATIVE. REPLACED BATTERY AT POSITION 10WL IAW AMM 33-51-38-400-002A WITH GOOD OPERATIONAL CHECK.SDR USAA2015040100003Power Supply · inoperativeEMERGENCY LIGHT IN LT FWD PARTITION INOPERATIVE. REPLACED EPSU AT POSITION 10WL IAW AMM 33-51-38-400-001A WITH GOOD OPERATIONAL CHECK.SDR CALA2015040293498Interface Unit · malfunctionedLEFT MLG FAILED TO INDICATE DOWN & LOCKED. CYCLED GEAR IAW CHECKLIST. LT MAIN GEAR UNSAFE, CRANKED GEAR DOWN, MANUAL GEAR EXTENSION. GREEN LIGHT NOT ILLUMINATED, NO ECAM MSGS. REPLACED FIN 9LP IAW MM 33-14-33-000 400-001A PN 35-OFS-1000 & LGCIU 1 IAW MM 32SDR GTIA2015033101546Bottle · low pressureR1 DOOR ACCUMULATOR LOW PSI. SERVICED R1 DOOR ASSIT ACCUMULATOR IAW AMM 52-10-00-614-001-A.SDR USAA2015033100008Power Supply · faultyELECTRICAL SMELL COMING FROM SOMEWHERE IN FWD GALLEY. REPLACED EPSU IN THE FWD GALLEY.SDR USAA2015033100001Fuel Filter · cloggedNUMBER 2 ENG FUEL FILTER CLOGGED AFTER TAKEOFF CLIMB FOR 10 MINUTES. REPLACED NR 2 ENG FUEL FILTER IAW TASK CARD 26T40073001.SDR CALA2015040293503Hydraulic Line · damagedDIVERT, YELLOW SYS HYD LOW PRESS FLUID LOSS, YELLOW SYS ACCUMULATOR LOSING PSI. REPLENISHED YELLOW SYS HYD DUE TO FLUID LOSS FROM PRESS LINE HOLE. R & R LINE, PRESS RESTORED.SDR USAA2015033000008Floor Panel · delaminatedFLOOR PANEL 221LF TOP LAYER DELAMINATING. REPLACED FLOOR PANEL 221LF IAW AMM 53-12-12.SDR USAA2015033000006Lens · brokenEMERGENCY EXIT LIGHT LENS ADJACENT L1 DOOR BROKEN. REPLACED EMER EXIT LIGHT LENS.SDR USAA2015032900003Pin · inoperativeLEFT FWD OVERWING EXIT HATCH DISARM PIN INOPERATIVE. R & R PIN IAW AMM 52-22-22. GOOD OPERATIONAL CHECK.SDR CALA2015033093487Door Sill · corrodedR1 DOOR SILL FRAME 16 - 20 FWD & AFT GIRT BAR FITTING ATTACH AREAS HAVE CORROSION AT FASTENER HOLES. REWORKED IAW SRM 53-11-14 PAR 4 E FIG 108.SDR CALA2015033093486Door Sill · corrodedL2 DOOR SILL FRAME 66 HAS TWO EACH CORRODED FASTENER HOLES. REPAIRED IAW SRM 53- 41-14 PAR 5 A FIG 201.SDR CALA2015033093485Stringer · corrodedSTRINGER 31R AT FRAME 64 - 67 HAS CORROSION. REPLACED IAW SRM 51-72-11.SDR CALA2015033093490Starter · faultyAPU ALTITUDE NO START, COLD SOAK. APU HANGS BETWEEN 0 - 19% DURING START, 3 ATTEMPTS, ALL THREE FAULTED, MAX RPM WAS 26. R & R APU STARTER IAW AMM 49-41-01.SDR USAA2015032700004Hinge Fitting · wornRIGHT MLG DOOR AFT HINGE BRASS BUSHING HAS EXCESSIVE PLAY IN MOUNT BRACKET. R & R REAR HINGE FITTING IAW CMM 52-81-18.SDR USAA2015032700003Battery · dischargedAFT LT FLIGHT ATTENDANT FLASHLIGHT BATTERY NEEDS REPLACEMENT. REPLACED FLASHLIGHT BATTERY.SDR YENA20150325060Wire Harness · damagedON MAINTENANCE CHECK FOUND ROW 1 ABC EMERGENCY LIGHT INOPERATIVE. R & R HARNESS TO LIGHT ASSY IAW AMM 33-51-19. OPS CHECK GOOD.SDR GTIA2015032401536Oxygen Mask · brokenF/O O2 MASK INFLATABLE HEAD BAND BROKEN. SWAPPED F/O AND OBSERVER MASK IAW AMM 35-12-41, OPS CHECK OK.SDR GTIA2015032401535Oxygen Mask · inoperative1ST OBSERVERS O2 MASK INOPERATIVE. R & R 1ST OBSERVERS O2 MASK IAW AMM 35-12-41. OPS CHECKED MASK WHICH NOW OPERATES PERFECTLY THIS CLEARS DMI 53165-1 PLACARD REMOVED MOC NOTIFIED.SDR CALA2015033093489Battery · failedEMERGENCY LIGHT BATTERY CAP TEST FAILS. REPLACED 10WL & 12WL IAW AMM 33-51-38-000-002-A & 33-51-38-400-002-A. CAPACITY TEST OK IAW AMM 33-51-00-710-003.SDR YENA20150323059Deu · malfunctionedON MAINTENANCE CHECK FOUND EMERGENCY LIGHTS FAIL THE TEST. EPSU COM EMERGENCY "L" IS DISPLAYED. R & R DEU 300RH4-B IAW AMM 23-73-47-000-001 AND 23-73-47-400-001. OPS CHECKS GOOD IAW AMM 33-51-00-710-001-A. SUP: INFORMATION WILL BE FILED FOR THE PN AND SN RESDR GTIA2015032301534Oxygen Mask · unwanted deployLAVATORY O2 MASK DEPLOYED. REPACK AND PERFORMED O2 MASK DROP CHECK. OPS CHECK OK. IAW AMM 35-23-00-710-001-A. TKIS CLEARS DMI 71240-2. PLACARD REMOVED. MOC NOTIFIED.SDR YENA20150325055Epsu · no testDURING MAINTENANCE, THE RED OVERWING EMERGENCY EXIT LIGHT IS NOT WORKING. R & R ESPU & BATTERY PACK IAW AMM 33-51-38. ALL EMERGENCY LIGHTS NOW CHECK OK. ADDITIONAL PART REPLACED, DIEHL, PN 3214-31, SN 767628, TAT 2218, TAC 816, TIME SINCE 2218.
Back to Airbus A320-232