Airbus A320-232
Service difficulty reports · 32,653
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A320232' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A320232' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR GTIA2014110101446Bottle · low pressureL1 DOOR ASSIST BOTTLE REQUIRES SERVICING. L1 DOOR ASSIST BOTTLE SERVICED IAW AMM 52-10-00.SDR USAA2014110300020Floor Panel · corrodedRON VISIT FLOOR PANEL 261LG HAS CORROSION ON INBD END SCREW HOLES & AFT OTBD EDGE. REPLACED FLOOR PANEL 261LG IAW AMM 53-32-12-400.SDR USAA2014110300027Sign · inoperativeRON VISIT EMER EXIT FWD FACING SIGN OVER AISLE AT AFT GALLEY NEEDS TO BE REPLACED. REPLACED EMER EXIT FWD FACING SIGN OVER AISLE AT AFT GALLEY.SDR USAA2014110300026Sign · inoperativeRON VISIT EMER EXIT SIGN AT RT EMER EXIT HATCH NEEDS TO BE REPLACED. REPLACED EMER EXIT SIGN AT RT EMER EXIT HATCH.SDR USAA2014110300019Intercostal · corrodedRON VISIT CORROSION ON SUPPORT FRAME INTERCOSTAL BETWEEN FRAME 69 TO 70, STRINGER 23L. REPLACED SUPPORT FRAME INTERCOSTAL BETWEEN FRAME 69 TO 70, STRINGER 23L IAW SRM 51-42-11.SDR USAA2014110300011Shear Plate · corrodedRON VISIT CORROSION ON SHEAR FRAME PLATE BETWEEN FRAME 69 TO 70, STRINGER 23L. REPLACED SHEAR FRAME PLATE BETWEEN FRAME 69 TO 70, STRINGER 23L IAW SRM 51-42-11.SDR USAA2014110300007Sign · inoperativeRON VISIT EMER EXIT SIGN AT R2 DOOR NEEDS TO BE REPLACED. REPLACED EMER EXIT SIGN AT R2 DOOR.SDR USAA2014103100009Battery · dischargedFORWARD FLIGHT ATTENDANT FLASHLIGHT BATTERY LOW. REPLACED FLASHLIGHT BATTERY, OPERATIONS NORMAL.SDR CALA2014103192645Door Sill · corrodedL2 DOOR SILL HAS CORROSION AT FRAME 68 UNDER NUTPLATE. INSTALLED ANGLE REPAIR IAW SRM 53-41-14 FIG 201.SDR YENA20141029237Power Supply · failedDURING MAINTENANCE CHECK, FOUND EMERGENCY LIGHT SYS TEST FAILED. R & R EPSU 10WL. OPS CHECKED NORMAL IAW AMM 33-51-38, PB 401.SDR YENA20141029236Power Supply · failedDURING MAINTENANCE CHECK, FOUND CENTER AISLE EMERGENCY EXIT SIGN NEAR SEAT 11 FAILED THE TEST. R & R EPSU 11WL. OPS CHECKED NORMAL IAW AMM 33-51-00-710.SDR YENA20141029235Wire · brokenON MAINTENANCE CHECK, FOUND EMERGENCY EXIT HARNESS ROW 20ABC HAD BROKEN WIRE. R & R EMERGENCY EXIT WIRE HARNESS ROW 20ABC IAW AMM 33-51-18. OPS CHECKED GOOD.SDR CALA2014103192644Door Sill · corrodedR2 DOOR SILL CORRODED JUST AFT OF FRAME 68. R2 DOOR SILL WAS FOUND CORRODED OUT OF LIMITS BETWEEN FRAME 66 & 68 IAW SRM 53-41- 14 FIG 101. R & R R2 DOOR SILL BEAM IAW SRM 51-42-11.SDR YENA20141028234Control Valve · failedAIR RETURN DUE TO CABIN TEMP FULL HOT. UNABLE TO CONTROL NR 1 PACK VALVE. INDICATED FULL OPEN AND HOT NO ECAM PRESENT. R & R 1 FLOW CONTROL VALVE, PERFORMED OPS CK + BITE TEST NO FAULTS NOTED AMM 21-51-51.SDR USAA2014102700003Eec · unserviceableLEFT N1 GAUGE INTERMITTENT, ECAM DISAGREEMENT. REPLACED E1 ELECTRONIC ENG CONTROL IAW JOB CARD 26L40073002.SDR YENA20141026233Battery Pack · failedDURING A MAINTENANCE CHECK, FOUND RT EPSU BATTERY FAILED. R & R THE BATTERY PACK IAW AMM 33-51-38. OPS CHECKED GOOD.SDR CALA2014102792622Connector · not seatedEMERGENCY LIGHT TEST FAILED ON 2 SERVICE. RESEATED CONNECTOR & BATTERY ON EMER LIGHT POWER SUPPLY IAW 33-51-38, TEST PASSED.SDR CALA2014102792619Stringer · corrodedMAJOR REPAIR & SDR. STRINGER 41R HAS CORROSION BETWEEN FRAME 59 & 64 IN AFT CARGO COMPARTMENT. R & R STRINGER 41R & FACTORY INSTALLED SPLICE IAW SRM 51-72-11 PGS 1 - 2. NO REQUIREMENT FOR SRI INSPECTIONS.SDR CALA2014102792613Skin Panel · contaminatedMAJOR REPAIR & SDR. RT ELEVATOR UPPER SKIN PANEL HAS TRAPPED WATER INDICATION 101.5 FROM INBD, 4.5 INCHES FROM TE, 3 INCHES DIAMETER. CUT OUT THE DAMAGED SKIN & CORE. REMOVED WATER APPLIED REPAIR & RESTORED FINISH IAW SRM 55-21-11 PARA 5E. REQUIRES RE-INSPSDR CALA2014102792612Epsu · inoperativeRIGHT EMER LIGHTS TEST FAIL WITH MSG EPSU EMER RT. REPLACED EPSU & BATTERY AT RT OVERWING DOOR IAW AMM 33-51-38. OPERATIONS CHECKED OK.SDR USAA2014102700006Lens · missingSEAT 3C EXIT TRACK LIGHT COVER MISSING. REINSTALL LENS IAW TROUBLE SHOOTING MANUAL 24-00-00-810-818-A.SDR YENA20141023232Wire Harness · failedACFT DIVERTED DUE TO NR 1 ENGINE EGT SPIKED AFTER TAKEOFF. EGT WITHIN LIMITS AFTER THRUST REDUCTION AT THE RED ALT, REDUCTION ALTITUDE. ECAM WENT AWAY. R & R EGT HARNESS AND JUNCTION BOX IAW AMM 77-21-43-400-804-B. OPS CHECK PERFORMED OK ON ENGINE RUN.SDR USAA2014102400010Light · malfunctionedCABIN EMER EXIT LIGHTS ON WHEN SWITCH IS ARMED. RESET CABIN EGRESS LIGHT SYS. OPERATIONS CHECKED NORMAL IAW AMM TSM 24-00-00.SDR USAA2014102300001Sensor · disengagedOVERWING SLIDE DOES NOT INDICATE ARMED ON ECAM LT & RT EMER EXITS. FOUND LT & RT OVERWING EMER EXIT ARMING PINS NOT ENGAGING ARMING SENSOR PIN. RE ARMED LT & RT OVERWING EMER EXITS TO ENGAGE ARMING SENSOR PINS. OPERATIONS CHECKED GOOD IAW MM 25-62-43-400. SDR CALA2014102392550Battery · failedEMERGENCY TEST FAILS AT 2 SERVICE, FAILS EMER LT BATTERY. REPLACED LT BATTERY AT SEAT 21A IAW AMM 33-51-38. OPERATIONS CHECKED GOOD.SDR YENA20141022231Power Supply · inoperativeDURING MAINTENANCE, FOUND EPSU AT 12WL BATTERY INOPERATIVE. R & R EPSU BATTERY AT 12WL IAW 33-51-38. OPS CHECKED GOOD.SDR CALA2014102392552Fan · malfunctionedEXTRACT FAULT DISPLAYED ON UPPER ECAM SCREEN. ELEC FUMES FOLLOWED BY VENT EXTRACT FAULT, TURNED OFF BLOWER EXTRACT CABIN FANS NO FUMES. REPLACED EXTRACT FAN 18HQ IAW AMM 21-26-51. COMPLETED OPERATIONAL TEST OF EXTRACT & BLOWER FANS IAW AMM 21-26-51-710-001-SDR YENA20141021226Contact · looseON MAINTENANCE CHECK FOUND ROW 7ABC SEAT EMERGENCY LIGHT INOPERATIVE. FOUND LOOSE CONTACT AT FIN 5751VC, PIN 2. REMOVED AND RESEATED CONTACT IAW ESPM 20-44-00. EMERGENCY LIGHTING SYS, OPS CHECK GOOD IAW AMM 33-51-00.SDR USAA2014102200006Floor Panel · delaminatedDELAMINATION ON FWD CGO FLOOR PANEL 131HF AT FRAME 31 BL0. REPLACED FWD CGO FLOOR PANEL 131HF IAW AMM 53-22-14.SDR YENA20141020225Wire · damagedCREW REPORTED ROW 10 RED EMERGENCY EXIT AISLE LIGHT INOPERATIVE. BARE WIRES, 2, EXPOSED AT ADJACENT SIDEWALL. REPAIRED WIRING TO CONNECTOR 7261VC IAW WM 33-51-07, OPS CHECKS GOOD.SDR YENA20141020224Wire · damagedCREW REPORTED THAT EMERGENCY EXIT LIGHT AT FLOOR LEVEL ON FWD BULKHEAD ROW 1 INOPERATIVE. REPAIRED WIRING AND REPLACED RED EMERGENCY LIGHT ASSY 361WL1 IAW WM 33-51-06 OPS CHECKS GOOD.SDR YENA20141020223Wire · damagedCREW REPORTED THAT EMERGENCY EXIT FLOOR LIGHTING RED LIGHT AFT END OF AISLE IS INOPERATIVE. IDENTIFIED LIGHT TO BE INSTALLED ON LAV D WALL. REPAIRED WIRING IAW ESPM 20-43-00. LIGHT OPS CHECK NORMAL.SDR YENA20141020222Connector · damagedCREW REPORTED EMERGENCY LIGHT AT 9C INOPERATIVE. REPINNED CONNECTOR 7261VC1A IAW AWM 33-51-07. OPS CHECK OK.SDR USAA2014102100005Apu · fireON TAXI OUT HAD 3 DIFFERENT ACFT SAY WE HAD FLAMES COMING OUT APU EXHAUST. PUSHED APU FIRE SWITCH & DISCHARGED THE FIRE AGENT. FIRE FROM TAILPIPE WENT OUT. RETURNED TO GATE WITH EMER EQUIPMENT FOLLOWING. INSPECTED APU IAW AMM 49-00-00-200-001-A. INSPECTIOSDR CALA2014102192546Door Sill · corrodedR2 DOOR SILL HAS CORROSION AT FRAME 68 AT PREVIOUS REPAIR. REPLACED DOOR SILL IAW SRM 51-42-11.SDR CALA2014102192543Light · malfunctionedEMERGENCY LIGHT TEST FAILED, EPSU BATTERY AFT. CYCLED EMER LIGHT CB`S CHECKED OK IAW AMM 33-51-00-710-001-A.SDR YENA20141018230Skin · corrodedDURING HEAVY MAINTENANCE CHECK, CORROSION FOUND ON THE RT WING TOP SKIN T/E. REMOVED CORROSION AND REPAIRED RT WING TOP SKIN IAW PT20-57-023 AND A14-661-01.SDR YENA20141018229Skin · corrodedDURING HEAVY MAINTENANCE CHECK, CORROSION WAS FOUND ON LT WING TOP SKIN T/E IAW EC A320-57-1154-01/02. REMOVED CORROSION IAW SRM 51-74-00, SRM 51-42-11 AND A14-661-01.SDR YENA20141018227Cable · bindingDURING HEAVY MAINTENANCE CHECK, DURING FUNCTIONAL TEST OF TASK CARD A320-52-21-00-720-001-833, FOUND BINDING ON LT OVERWING EXIT DOOR CABLE. R & R LT OVERWING EXIT CABLE. ADJUSTMENT AND TEST, OPS CHECK GOOD IAW AMM 25-62-43.SDR YENA20141017220Power Supply · no testDURING HEAVY MAINTENANCE, EMERGENCY LIGHTS TEST FAILED AT EPSU UNIT AT POSITION 11WL. R & R EPSU AT POSITION IAW AMM 33-51-38. OPS CHECKED GOOD.SDR YENA20141017228Skin · corrodedDURING HEAVY MAINTENANCE CHECK, CORROSION WAS REPORTED ON THE TOP SKIN PANEL 2 RIB-6-9, OF THE T/E OVERHANG. REMOVED CORROSION IAW SRM 51-74-00. JACKED ACFT AND REMOVED CORROSION FROM RT WING TOP SKIN AT THE T/E LOWER SURFACE RIB 7A. ACCOMPLISHED FINAL REPAISDR USAA2014102000003Compressor · stalledENGINE NR 2 COMP STALL. 1ST STALL AT 600FT AGL, ENG QUICKLY RECOVERED ENG STALLED 2ND TIME AT 2500FT WHILE CLIMBING, ALSO RECOVERED QUICKLY. ENG WAS AT TOGA THRUST FOR THE 1ST COMP STALL, WAS AT CLIMB THRUST WHEN 2ND COMP STALL OCCURRED. ENG FAILED BORESCOPESDR USAA2014102000002Lens · missingEMERGENCY LIGHT LENS MISSING AT ROWS 3 & 26. REPLACED EMER LIGHT LENS AT ROWS 3 & 26.SDR YENA20141017221Battery Pack · no testDURING HEAVY MAINTENANCE, LIGHTING TEST FAILED, BATTERY AFT LT POSITION 13WL. TROUBLESHOT TO BATTERY AT POSITION 13L TO BE AT FAULT. R & R BATTERY AT POSITION 13WL IAW AMM 33-51-38. OPS CHECK GOOD.SDR YENA20141017219Pickup · failedDURING APPROACH AND SELECTING FLAPS TO 2 DEGREES WITH SPEED BRAKES OUT, RECEIVED F/CTL FLAPS LOCKED WING TIP ON ECAM. COMPLETED ECAM ACTION AND LANDED UNEVENTUALLY. R & R ASYMMETRY POSITION PICK OFF UNIT ON THE LT SIDE, IAW AMM 27-51-18. OPS CHECK, FLAPS GOOSDR USAA2014101600014Battery · dischargedAFT RT FLASHLIGHT INOPERATIVE. REPLACED BATTERY.SDR USAA2014101600007Windshield · crackedFLIGHT CANCELLED & ACFT FERRIED FOR FIRST OFFICER`S WINDSHIELD CRACKED & DELAMINATED. R & R FIRST OFFICER'S WINDSHIELD IAW JOB CARD 26L210560021.SDR USAA2014101400003Battery Pack · dischargedFORWARD FLASHLIGHT NOT CHARGING. REPLACED BATTERY PACK, OPERATIONS CHECKED GOOD.SDR YENA20141013216Battery · no testEMERGENCY LIGHT TEST FAILED. R & R BATTERY ON LT FIN 11WL EMERGENCY POWER SUPPLY. LIGHT TESTED OK IAW AMM 33-51-38.SDR USAA2014101400007Apu · malfunctionedDIRTY SOCK SMELL ON ARRIVAL. R & R THE APU IAW JOB CARD 26L31049005. OPERATIONS GOOD. DECONTAMINATION COMPLIED WITH IAW JOB CARD 26L00021004. NO ODOR AT THIS TIME.
Back to Airbus A320-232