SDR USAA2014112000006Slide · faultyEMERGENCY LIGHT TEST THROUGH PTP PANEL FAILS AT FWD LT LOCATION STEP 14F ON WEEKLY CHECK. FLASHING FAULT LIGHTS ON INTERIOR LIGHTS FAULT & EXTERIOR LIGHTS FAULT ON EMER POWER SUPPLY UNIT. REPLACED R1 DOOR SLIDE ASSEMBLY IAW JOB CARD 26L0025010. EMER LIGHT TSDR USAA2014112000004Cover · brokenEXIT LIGHT COVER SEAT 1C BROKEN. REPLACED EXIT LIGHT COVER AT SEAT 1C AS REQUIRED.SDR USAA2014112000003Power Supply · faultedEMERGENCY LIGHT TEST THROUGH PTP PANEL FAILS AT FWD LT LOCATION STEP 14F ON WEEKLY CHECK. FLASHING FAULT LIGHTS ON INTERIOR LIGHTS FAULT & EXTERIOR LIGHTS FAULT ON EMER POWER SUPPLY UNIT. R & R FWD LT EMER LIGHT POWER SUPPLY UNIT IAW AMM 33-51-00.SDR USAA2014112000002Cover · brokenCOVER FOR SEAT 3C EMER LIGHT BROKEN. INSTALLED SERVICEABLE EMER LIGHT COVER AT SEAT 3C.SDR CALA2014112492729Threshold · corrodedAFT CARGO DOORWAY THRESHOLD CORRODED FRAME 52 - 56 AT STRINGER 38R. REPLACED AFT CARGO THRESHOLD FROM FRAME 52 - 56 IAW SRM 51-42-11.SDR YENA20141118257Switch · unknownFLASH FOLLOWED BY BANG AND SMOKE ODOR FROM RT REAR CORNER OF FLIGHT DECK, SMOKE ODOR DISSIPATED AFTER 30 SEC. ACCOMPLISHED GENERAL WALKAROUND INSP IAW AMM 05-20-00, NO UNUSUAL FINDINGS. ACCOMPLISHED GENERAL VISUAL INSP OF ALL E/E COMPARTMENTS, NO UNUSUAL FINSDR USAA2014112000007Scavenge Pump · leakingFLIGHT DIVERTED & AN EMER DECLARED DUE TO CABIN ODOR & A CTR FUEL TANK TRANSFER ISSUE. CLIMBING THROUGH 15,000FT FLIGHT ATTENDANT REPORTED A STRONG DIRTY SOCKS SMELL. ACCOMPLISHED JOB CARD 26L00021001, FOUND NR 2 ENG OIL LEAK IN NR 5 BEARING AREA. EXCESSIVESDR YENA20141118255Power Supply · failedON MAINTENANCE CHECK, FOUND EMERGENCY LIGHT AT LT OVERWING EXIT INOPERATIVE. R & R ELPU NR 4 IAW AMM 33-50-01. OPS CHECKED NORMAL.SDR USAA2014111900010Fuel Control · faultyFLIGHT DIVERTED & AN EMER DECLARED DUE TO CABIN ODOR & A CTR FUEL TANK TRANSFER ISSUE DURING CLIMB. CTR TANK FAULT, FUEL PUMPS IN CTR TANK WILL NOT ACTIVATE IN AUTO OR MANUAL. ACCOMPLISHED TSM 28-21-00-810-829-A, OPERATIONAL CHECKED OK FOR SERVICE IAW AMM 28SDR YENA20141118250Battery Pack · no testDURING MAINTENANCE CHECK OF CABIN EMERGENCY LIGHTS, FOUND AFT BATTERY PACK SHOWING EXTERIOR LIGHT FAULT AND BATTERY FAULT. R & R BATTERY PACK IAW AMM CH 33-51-38. OPS CHECKED GOOD.SDR CALA2014112892746Skin Panel · damagedLEFT ELEVATOR UPPER SKIN PANEL HAS WATER INGRESS INDICATION AT 11.5 INCHES FROM INBD END, 5.0 INCHES FROM TE, 3.5 INCHES IN DIAMETER & AT 28 INCHES FROM INBD END 8 INCHES FROM TE & 3 INCHES IN DIAMETER. CUT OUT TRAPPER WATER INDICATION IN BOTH AREAS APPLIED RSDR CALA2014112492738Skin Panel · damagedLEFT ELEVATOR UPPER SKIN PANEL HAS WATER INGRESS INDICATION AT 11.5 INCHES FROM INBD END, 5.0 INCHES FROM TE, 3.5 INCHES IN DIAMETER & AT 28 INCHES FROM INBD END, 8 INCHES FROM TE, 3 INCHES IN DIAMETER. CUT OUT TRAPPED WATER INDICATION IN BOTH AREAS APPLIED RSDR CALA2014112492736Stringer · corrodedFORWARD CARGO INNER AFT BILGE AREA HAS CORROSION ON STRINGER AROUND RIVET HOLES AS MARKED 1 TO 6 INCHES FWD OF FRAME 34. R & R STRINGER 44 FROM FRAME 30 & 31 TO END FITTING AT FRAME 35 IAW SRM 5 1-42-11.SDR CALA2014112492735Stringer · corrodedFORWARD CARGO INNER AFT BILGE AREA HAS CORROSION ON STRINGER 43R AROUND RIVET HOLES AS MARKED 1 TO 4 INCHES FWD OF FRAME 34. R & R WITH NEW STRINGER FROM FRAME 30 TO 35 IAW SRM 51-42-11.SDR CALA2014112492734Door Sill · corrodedR2 LOWER DOOR SILL CORRODED BEYOND LIMITS IAW SRM 5 3-41-14. REMOVED DOOR SILL & INSTALLED NEW DOOR SILL IAW SRM 51-42-11.SDR CALA2014112492733Stringer · corrodedFORWARD CARGO INNER AFT BILGE AREA HAS CORROSION ON STRINGER 43L AROUND RIVET HOLE AS MARKED 1 TO 4 INCHES FWD OF FRAME 34. R & R WITH NEW STRINGER FROM FRAME 31 - 35 IAW SRM 51-42-11.SDR CALA2014112492732Stringer · corrodedAFT CARGO COMPARTMENT AT FRAME 56, STRINGER 4L CORRODED. SPLICED IN NEW STRINGER SECTION IAW SRM 53-00-13 FIG 201.SDR YENA20141117253Windshield · crackedCREW REPORTED AT FL 370, A LOUD POP AND ELECTRICAL ARCING ON FRONT RT WINDSHIELD. ECAM ANTI-ICE RT WINDSHIELD. FOUR LONG CRACKS ON WINDSHIELD OUTER FLY. R & R F/O FRONT WINDSHIELD. GROUND OPS CHECK OK. AIR LEAK CHECKED. NO LEAKS FOUND IAW 56-11-11.SDR YENA20141117252Battery Pack · no testDURING MAINTENANCE CHECK, FOUND EMERGENCY LIGHT FAILED THE FUNCTIONAL TEST. R & R BATTERY PACK 13WL AND 12WL IAW AMM 33-51-38. EMERGENCY LIGHT CHECKED GOOD.SDR YENA20141117251Battery Pack · no testDURING MAINTENANCE CHECK, FOUND EMERGENCY LIGHT FAILED THE TEST. R & R BATTERY PACK 13WL AND 12WL IAW AMM 33-51-38. EMERGENCY LIGHT CHECKS GOOD.SDR GTIA2014111601452Bottle · low pressureL2 PASSENGER DOOR ASSIST BOTTLE LOW. SERVICED THE ASSIST BOTTLE IAW AMM 52-12-14.SDR YENA20141116249Sensor · failedCREW REPORTED NOSE WHEEL STEERING (NWS) FAULT. WILL NOT RESET. LOST ALL STEERING DURING LANDING. ACFT TOWED TO GATE. R & R 3GC NWS FEEDBACK SENSOR IAW AMM 32-51-19. OPS CHECK GOOD.SDR YENA20141116246Solenoid · leakingAIR RETURN DUE TO ENG 1 BLEED LEAK. ACCOMPLISHED TSM 36-22-00-810-803-A. FOUND THERMOSTAT SOLENOID 10HA1 LEAKING. R & R THE SOLENOID IAW AMM 36-11-55. LEAK AND OPS CHECKED NORMAL.SDR GTIA2014111301451Bottle · low pressureL1 DOOR ASSIST BOTTLE PRESSURE IS LOW. SERVICED THE L1 DOOR BOTTLE IAW AMM 52-10-00, LEAK CHECKED GOOD.SDR CALA2014111492705Stringer · corrodedFORWARD CARGO INNER AFT BILGE AREA HAS CORROSION ON STRINGER 24L AROUND RIVETS HOLES AS MARKED 4 TO 8 INCHES FWD OF FRAME 34. R & R WITH NEW FACTORY STRINGER 24 LT FROM FRAME 30 TO 34 IAW SRM 51-42-11.SDR CALA2014111492704Stringer · corrodedAFT CARGO FLOOR LT SIDE AT FRAME 63 TO 64 STRINGER 41 LT HAS CORROSION. R & R WITH NEW FACTORY STRINGER 41 LT FROM FRAME 60 TO 64 IAW SRM 51- 42-11.SDR CALA2014111492703Stringer · corrodedAFT CARGO FLOOR RT SIDE AT FRAME 63 TO 64 STRINGER 42 RT HAS CORROSION. R & R WITH NEW FACTORY STRINGER 42 RT FROM FRAME 60 TO 64 IAW SRM 51- 42-11.SDR USAA2014111400005Apu · leakingACRID, MUSTY SMELL THROUGHOUT CABIN & COCKPIT LAST 10 MINS OF FLIGHT. FIRST CLASS PAX COMPLAINED, COVERED NOSES & MOUTHS. SMELL STRONGER IN CABIN THAN FLIGHT DECK, VERY NOTICEABLE. ODOR HAD DISSIPATED AS WE PULLED INTO THE GATE. FOUND APU OIL LEAK, CORRECTSDR CALA2014111492698Skin · crackedFUSE SKIN FRAME 35 & CM 10 THE LT AFT LOWER HOLE NR 2 HAS CRACK INDICATION 5:00 POSITION. REPAIRED NR 2 HOLE & INSTALLED FASTENER LT FRAME 35 IAW ECRA 53 30-04940. REPAIR OF CRACKED & ELONGATED FASTENER HOLE FRAME 35 BELOW STRINGER 30LT HAS BEEN APPROVED AS SDR USAA2014111300004Oven · faultyLEFT OVEN SMOKES WHEN TURNED ON SMOKE QUITS WHEN OVEN IS TURNED OFF. REPLACED FWD LT OVEN IAW AMM 25-35-19.SDR YENA20141112245Fitting · corrodedDURING HEAVY MAINTENANCE CHECK, CORROSION WAS FOUND ON THE LT WING OTBD SIDE OF SPOILER NR 3 FITTING. GAINED ACCESS AND REMOVED CORROSION FROM SPOILER FITTING NR 3. FOUND CORROSION TO BE OUT OF LIMITS. FABRICATED AND INSTALLED REPAIR DOUBLER AND RESTORED AREASDR USAA2014111200003Floor Panel · damagedSOFT SPOT IN AISLE AT ROW 23. REPLACED FLOOR PANEL AT ROW 23 IAW AMM 53-42-12.SDR GTIA2014111001450Bottle · low pressureDOOR ASSIST ACCUMULATOR LOW PRESSURE. SERVICED DOOR ASSIST ACCUMULATOR WITH N2 IAW AMM 52-10-00-614-001-A.SDR CALA2014111092678Door Sill · corrodedL2 DOORSILL CORRODED AT GIRT BAR ATTACH HOLES. L2 DOORSILL REPLACED IAW SRM 51-42-11.SDR CALA2014111092677Stringer · corrodedAFT PIT STRINGER 42L CORRODED BETWEEN FRAME 63 & 64. STRINGER 42L REPLACED BETWEEN FACTORY SPLICES AT FRAME 60 & 64 IAW SRM 51-42-11.SDR CALA2014111092676Door Sill · corrodedRIGHT AFT CABIN DOOR SILL CORRODED AT NUTPLATE ATTACHMENT AT FRAME 68. CORROSION REMOVED & AREA REPAIRED IAW SRM 53-41-44 REPAIR PRINCIPAL 5.SDR USAA2014111000009Lens · missingSEATS 1L & 11R EMER LIGHT LENS MISSING. REPLACED SEATS 1L & 11R EMER LIGHT LENS AS REQUIRED.SDR GTIA2014110601447Bottle · low pressureDOOR ASSIST ACCUMULATOR LOW PRESSURE. SERVICED THE DOOR ASSIST ACCUMULATOR IAW AMM 52-10-00-614-001-A.SDR YENA20141106244Horn · out of adjustDURING HEAVY MAINTENANCE CHECK, RT OVERWING SLIDE MANUAL RELEASE FAILED CHECK. ADJUSTED HORN END OF CONDUIT HOUSING TO TOP OF HATCH BRACKET INNER RELEASE CABLE IAW AMM 25-62-43. PULL TEST CHECKED OK.SDR YENA20141106243Battery Pack · no testOPS CHECK OF EMERGENCY LIGHTS FAILED. FOUND BATTERY FAULT AT EPSU 11WL, EMERGENCY LEFT, R & R BATTERY AT EPSU 11WL IAW AMM 33-51-38. OPS TEST OF EMERGENCY LIGHTS NOW TESTS OK.SDR CALA2014110792662Fitting · corrodedL2 DOOR LOWER AFT CORNER FITTING HAS CORROSION AT LOWER FLANGE OF FRAME 68. REMOVED CORROSION & FOUND MATERIAL LOSS TO BE .018 INCHES. ORIGINAL THICKNESS WAS .070 INCHES, BEYOND LIMITS IAW SRM 51-73-11 PARA D 1. R & R L2 DOOR LOWER AFT CORNER FITTING IAW SRSDR CALA2014110792661Stringer · corrodedAFT CARGO STRINGER 41R AT FRAME 63 - 64 HAS CORROSION. REPLACED FACTORY STRINGER SECTION 41R FROM FRAME 58 - 64 IAW SRM51-42-11.SDR CALA2014110792660Charger · malfunctionedEMERGENCY LIGHT SYS FAILED TEST. FAULTS ATA 33-51-38 BATTERY FED LT. RESET FWD CHARGING UNIT & SYS TESTED GOOD IAW MM 33-51-00.SDR USAA2014110600007Lens · missingEXIT LIGHT COVER TO RT OF LT FWD WING EXIT MISSING, NEAR SEAT 10A. REPLACED EMER EXIT LIGHT LENS COVER AT ROW 10ABC. OK FOR SERVICE.SDR USAA2014110600002Battery · dischargedFORWARD EMER FLASHLIGHT SHOWS NO CHARGE. REPLACED BATTERY IN FWD EMER FLASHLIGHT. OPERATIONS CHECKED GOOD.SDR YENA20141103241Power Supply · faultedDURING WEEKLY SERVICE, AFT LT EPSU FAULTED. R & R AFT LT EPSU IAW AMM 33-51-38, BITE TEST GOOD NO FAULTS NOTED.SDR YENA20141102242Clamp · detachedCREW DECLARED AN EMERGENCY AND ACFT DIVERTED DUE TO N1 MODE ECAM, FOLLOWED BY FADEC ECAM, FOLLOWED BY ENGINE 2 FAILURE ECAM. ENGINE SHUT ITSELF DOWN. APPROPRIATE ECAM, QRC, + QRH PROCEDURES RUN. ON TROUBLESHOOTING FOUND THE FAILURE OF EEC OVERHEAT THAT RESUSDR CALA2014110492650Skin Panel · saturatedRIGHT ELEV UPPER SKIN PANEL HAS A TRAPPED WATER INDICATION 64.5 FROM INBD, 12 INCHES FROM TE, 2 INCH DIAMETER. REPAIRED ELEV UPPER SKIN BY REMOVING DAMAGE & REPAIRED IAW SRM 55-21-11 REPAIR 5 & FIG 205 CONFIG 1 ZONE L.SDR YENA20141103238Skin · corrodedDURING HEAVY MAINTENANCE CHECK, CORROSION WAS FOUND AT LT WING T/E SKIN AT RIB 7, 8, 15, 16 & 17. REMOVED CORROSION AT LT WING T/E SKIN FOR RIBS 6-9 AND 15-17 IAW A14-714-01.SDR YENA20141101240Power Supply · no testDURING ACCOMPLISHMENT OF TC A320-33-51-00-710-003, FOUND 13WL EPSU FAILED CAPACITY TEST. R & R EPSU AT POSITION 13WL IAW AMM 33-51-38. OPS CHECK GOOD.
Back to Airbus A320-232