SDR CALA2014060291188Attach Bolt · wornNUMBER 4 RT WING FLAP TRACK AFT CANOE FAIRING ATTACH BOLT WORN. INSTALLED NEW BOLT IAW AMM 57-55-11-400-001.SDR CALA2014060291187Attach Bolt · wornNUMBER 3 RT WING FLAP AFT CANOE FAIRING ATTACH BOLT WORN. INSTALLED NEW CANOE FAIRING BOLT IAW AMM 57-55-11-400-001.SDR USAA2014053000012Control Unit · malfunctionedBRAKE SYS NR 1 & AUTO BRAKE FAULT. PILOT DECLARED A EMER & LANDED WITHOUT INCIDENT, ACFT WAS TOWED TO GATE. BSCU RESET WAS ACCOMPLISHED.SDR YENA20140529102Battery Pack · failedON MAINTENANCE CHECK, FOUND EPSU 11WL FAILED THE EMERGENCY LIGHT TEST. R & R BATTERY PACK FOR EPSU 11WL, OPS CHECKED GOOD IAW AMM 33-51-38.SDR CALA2014060591215Fan · faultyCREW REPORTS BURNING PLASTIC SMELL & ODOR FROM REAR GALLEY AREA. NO SMOKE OR HAZE WAS PRESENT, ONLY ODOR. TURNED OFF AFT GALLEY POWER & ODOR DISSIPATED. IAW TSM 21-00- -00-810-802-A & SIL 21-132. CHECKED AFT GALLEY & CABIN NO ODOR. IAW MM05 51 10 200 801CSDR CALA2014060291189Proximity Switch · dirtyDOOR 1L NOT SHOWING ARMED. VERIFIED DOOR CLOSED & ARMED PRIOR TO DEPARTURE. CLEANED PROXIMITY SWITCH 4WN1 SYS CHECK NORMAL.SDR CALA2014060291186Unknown · malfunctionedCREW REPORTS BURNING SMELL ODOR FROM REAR GALLEY AREA. CREW REPORTS ODOR SMELLED LIKE BURNING PLASTIC. NO SMOKE OR HAZE WAS PRESENT, ONLY ODOR. CREW TURNED OFF AFT GALLEY POWER & ODOR DISSIPATED. FOUND SUPPLY RECIRC FAN CB OUT TESTED & POPPED AGAIN. COLLASDR USAA2014052800006Wire Harness · inoperativeR & R EMERGENCY LIGHT HARNESS AT ROW 19L IAW ASM 33-51-04, OPERATIONS CHECKED GOOD.SDR GTIA2014052701323Seal · tornL2 DOOR SEAL TORN. UPON INSPECTION OF L2 DOOR SEAL NOTED NO DEFECT WITH SEAL. SEAL COMPRESSES WHEN L2 DOOR IS CLOSED. NO CRACKING/CUTS OR OTHER DAMAGE TO SEAL IS NOTED IAW MM 52-13-18-220-050-A.SDR YENA20140527103Unknown · smokeCREW REPORTED FUMES IN COCKPIT ENROUTE, NO VISIBLE SMOKE, ELECTRICAL ODOR. PERFORMED TSM 24-00-00-810-823A, FOUND LTV SYTEM AT FAULT. CONFIRMED BY PULLING CIRCUIT BREAKERS. ACFT PACKS OPERATE NORMALLY, ALL ZONES OPERATE NORMALLY. LIVE TV SYS DEACTIVATED. TECSDR CALA2014052791161Engine · odorIAW CREW ON TAKEOFF, GOT AIR BLEED 2 MSG & WITHIN 30 SECONDS SMOKE ALARM IN FWD LAVATORY WENT OFF. CABIN CREW SAID THEY STARTED GETTING SMELL & ODOR AROUND ROW 23 THEN SMELL MOVED FWD TO AROUND ROW 8 & SMELL STARTED TO INTENSIFY. SMELL WAS COMING FROM NR 2 ESDR GTIA2014052701317Bottle · low pressureFWD RT DOOR EMERGENCY ACTUATOR PRESSURE LOW. SERVICED R1 DOOR TO PROPER PRESSURE IAW AMM 52-10-00-614-001.SDR CALA2014052791163Release Mech · dirtyDURING O2 MASK DROP TEST IAW AMM 35-23-00-710-001-A, MASKS DID NOT DEPLOY AT ROW 12 ABC. CLEANED PLUNGER O2 DOOR RELEASE MECHANISM OPERATIONS CHECKS NORMAL IAW AMM 35-23 -00 IDT INSP PERFORMED.SDR YENA20140525100Servo Control · leakingDURING CRUISE, FLT 390, WITH AUTOPILOT ON, EXPERIENCED SUDDEN FIVE DEGREE ROLL OR DIP TO LT WITH IMMEDIATE RECOVERY. AT SAME TIME FLIGHT CONTROL AILERON SERVO FAULT ECAM APPEARED ON FLIGHT CONTROL PAGE LT AILERON "B" HAS AMBER BOX DISPLAYED. ECAM & QRH COMPSDR CALA2014052791148Door Sill · corrodedR2 DOOR SILL AFT GIRT BAR ATTACH FITTING ATTACH HOLES HAVE CORROSION. R & R R2 DOOR SILL DUE TO NO CORROSION OR REWORK ALLOWED AT JOINTS ON FRAME 66 & 68 IAW SRM 53-41-14, FIG 101, PG 103 & SRM 51-42-11, PG 1- 7.SDR USAA2014052700045Structure · dirtyR1 DOOR WILL NOT ARM. FOUND R1 DOOR ARMING LEVER CONTACTING TRIM PIECE ON FLOOR. REMOVED TRIM, CLEANED MOUNTING SURFACE & REINSTALLED.SDR USAA2014052700042Slide · defectiveDOOR 1L GUST LOCK RELEASE BUTTON HARD TO PUSH DOWN. REPLACED ESCAPE SLIDE AT DOOR L1.SDR YENA20140524101Power Supply · failedMAINTENANCE CHECK FOUND EMERGENCY LIGHTING FAILED, FAULT MESSAGE EPSU BATTERY FWD L. REPLACED BATTERY POWER SUPPLY UNIT 10WL IAW AMM 33-51-38-400-002A. OPS CHECKED OK IAW AMM 33-51-00-710-001A.SDR CALA2014052791169Generator · malfunctionedDURING CLIMB LOST GENERATOR NR 2.SDR CALA2014052791147Start Valve · faultyCREW REPORTS DURING NR 2 ENG START APU BLEED PRESS SHOWS ONLY 22 PSI, ENG DID NOT START, CYCLED APU BLEED SWITCH, PRESS RECOVERED TO 30 PSI BUT LATER DROPPED TO 20 PSI. UNABLE TO START ENG WITH START VLV FAULT, RESET A05 & Q4 0 CROSS BLEED START RESULTED IN SSDR CALA2014052791146Epsu · faultedLT CTR EPSU FAULTED DURING CABIN EMERGENCY LIGHTING CHECK IAW JOB CARD 4-2020 STEP 26. REPLACED LT CTR EPSU & BATTERY. RAN TEST AGAIN FROM PTP PANEL, FWD CABIN. SYS CHECKED GOOD.SDR USAA2014052700046Power Supply · inoperativeAFT EMERGENCY LIGHT INOPERATIVE. REPLACED THE EMERGENCY POWER SUPPLY UNIT.SDR USAA2014052700044Acm · malfunctionedRETURN TO GATE WITH SMOKE IN FWD GALLEY & FIRST CLASS CABIN STARTED IN AFT PART OF ACFT & MOVED FWD. REPLACED RT PACK AIR CYCLE MACHINE & PLENUM CHAMBER IAW AMM TASK 21-52-21-000-001& 21-52-21-400-001.SDR GTIA2014052301311Flashlight · inoperativeF/O FLASHLIGHT INOPERATIVE. REPLACED FLASHLIGHT IAW AMM 33-10-00. OPS CHECKED NORMAL.SDR GTIA2014052301310Oxygen Mask · inoperativeOBSERVERS OXYGEN MASK INOPERATIVE. R & R OBSERVERS OXYGEN MASK IAW AMM 35-12-41 PB 401. OPS CHECKED GOOD.SDR GTIA2014052301309Oxygen Mask · inoperativeF/O OXYGEN MASK WILL NOT TEST. INTERCHANGED F/O OXYGEN MASK WITH 1ST OBSERVER OXYGEN MASK IAW AMM 35-12-41-400-001-A. BOTH OXYGEN MASK OPS CHECKS GOOD.SDR YENA20140523099Battery Pack · failedDURING MODIFICATION, IT WAS DISCOVERED THE EMERGENCY LIGHT FAILED MESSAGE EPSU BATTERY RT ILLUMINATED. R & R 12WL EPSU BATTERY IAW AMM 33-51-38-000-002-A AND 33-51-38-710-052 B STEP (1). OPS CHECKED NORMAL.SDR YENA20140522098Hose · leakingAFTER LANDING, GREEN HYDRAULIC SYS RESERVIOR LOW LEVEL ILLUMINATED. R & R HYDRAULICS HOSE ON ENGINE NR 1 IAW AMM 29-11-06. OPS CHECKED NORMAL, NO LEAKS NOTED. GREEN SYSTEM SERVICED.SDR USAA2014052300011Acm · malfunctionedRETURN TO GATE WITH SMOKE IN FWD GALLEY & FIRST CLASS CABIN. STARTED IN AFT PART OF ACFT & MOVED FWD. REPLACED RT PACK AIR CYCLE MACHINE & PLENUM CHAMBER IAW AMM TASK CARDS 21-52-21-000-001 & AMM 21-52-21-400-001.SDR CALA2014052291129Battery · dischargedFOUND RT OVERWING EXIT POWER SUPPLY BATTERY BAD. REPLACED BATTERY IAW MM 33-51-38. INSPECTED RT OVERWING EXIT POWER SUPPLY INSTALLATION & OPERATIONS CHECKED EEL LIGHTING IAW MM 33-51-38.SDR CALA2014052291128Battery · dischargedRIGHT OVERWING EXIT EMERGENCY LIGHTS FAILS EEL LIGHT TEST. FOUND RT OVERWING EXIT POWER SUPPLY BATTERY BAD. REPLACED BATTERY IAW MM 33-51-38. OPERATIONS CHECKED OK.SDR CALA2014052291127Frame · corrodedCORROSION FOUND ON FWD FACE ON FRAME 68 BETWEEN STRINGER 23R & 24R. REMOVED CORROSION AT FWD FACE OF FRAME. PERFORMED REPAIR AT FRAME 68 BETWEEN STRINGER 23R & 24R. REPAIR REQUIRES RE-INSP AT 36294 FC OR 78006 TOTAL FH WHICHEVER COMES FIRST IAW ECRA 5311-01SDR CALA2014052291126Structure · corrodedAFT CARGO COMPARTMENT SHOW SIGNS OF CORROSION AT STRINGER 42R 6 INCHES AFT OF FRAME 64. PERFORMED LT ANGLE REPAIR AT AFT CARGO COMPARTMENT AT STRINGER 42R AFT OF FRAME 64 IAW SRM 53-00-13 FIG 203 SHEET 3. REPAIR IS A CATEGORY B REPAIR & REQUIRES RE-INSP AT 6SDR CALA2014052291125Structure · corrodedAFT CARGO COMPARTMENT SHOW SIGNS OF CORROSION AT STRINGER 42L BETWEEN FRAME 54 & FRAME 55. PERFORMED LT ANGLE REPAIR AT AFT CARGO COMPARTMENT STRINGER 42L BETWEEN FRAME 54 & FRAME 55 IAW SRM 53-00-13 FIG 205 SHEET 3. REPAIR IS A CATEGORY B REPAIR & REQUIRES SDR CALA2014052291124Structure · corrodedAFT CARGO COMPARTMENT SHOW SIGNS OF CORROSION AT STRINGER 42L JUST AFT OF FRAME 63. PERFORMED LT ANGLE REPAIR AT AFT CARGO COMPARTMENT STRINGER 42L JUST AFT OF FRAME 63 IAW SRM 53-0 0-13 FIG 203 SHEET 3. REPAIR IS A CATEGORY B REPAIR & REQUIRES RE-INSP AT 6SDR CALA2014052291122Skin · corrodedCORROSION AFT CARGO COMPARTMENT JUST AFT RT FRAME 57 UNDER FLOOR STRINGER 38. PERFORMED LT ANGLE REPAIR AT AFT CARGO STRINGER 42L BETWEEN FRAME 58 & FRAME 59 IAW SRM53-00-13 FIG 205 SHEET 3. REPAIR IS A CAT B REPAIR & REQUIRES RE-INSP AT 60000 FC & 75000 FH SSDR USAA2014052200012Control Servo · unserviceableAIRCRAFT EXPERIENCED SLIGHT ROLL OSCILLATIONS, LEFT DURING CRUISE CLIMB AT .78 265 KIAS FOLLOWED IMMEDIATELY BY FLIGHT CONTROL AILERON SERVO FAULT ECAM. FLIGHT CONTROL STATUS PAGE DISPLAYED G AILERON SERVO INOPERATIVE SYMBOLOGY. ALTITUDE FL310 CLIMBING. ROLLSDR CALA2014052291111Stringer · corrodedAFT CARGO BAY SHOWS SIGNS OF CORROSION ON STRINGER 42R, 9 INCHES AFT OF FRAME 63. PERFORMED ANGLE REPAIR IAW SRM 53-00-13 FIG 203 SHEET 3 REPAIR IS A CAT B.SDR CALA2014051991064Spar · chafedNUMBER 1 PYLON LOWER SPAR HAD CHAFE MARK FROM CONTACT WITH THE CNA. BLENDED & WITHIN LIMITS IAW SRM 54-51-12 FIG 103. MAX MATERIAL LOSS IS 0.017, EXTENDED CHAFE PLATE INST IAW SRM 54-51-12 PARA 5 B FIG 202. REQUIRES INSPECTION IAW SRI54-51-12-2-001-00 PARA SDR CALA2014051991061Support · corrodedFRAME 60 - FRAME 70 CIRCUMFERENTIAL SUPPORT FOUND CORRODED. R & R SUPPORT FRAME D5347112320200 IAW A320 51-72-11.SDR YENA20140518097Skin · corrodedDURING HEAVY MAINTENANCE VISIT, CORROSION WAS REPORTED AT ONE LOCATION ON THE LT WING, UPPER SKIN PANEL, LOWER SURFACE, T/E BETWEEN RIBS 14-15, REAR SPAR DATUM. REMOVED CORROSION BY BLEND OUT, PERFORMED NDT AND REPLACED FASTENERS WITH THE BLENDED AREAS AS OVESDR CALA2014051991065Light · intermittentOVERHEAD EMERGENCY LIGHTS INOPERATIVE. LIGHTS GO ON & OFF BY THEMSELVES. UNABLE TO DUPLICATE. EEL BITE TEST AT FAP OKAY. ALL LIGHTS OPERATIONAL NO HISTORY NOTED.SDR YENA20140518096Safety Valve · failedAIR RETURN DUE TO CABIN PRESSURE SAFETY VALVE OPEN. COMPLIED WITH ECAM & QRH DELTA P PEAKED 8.2, CABIN PERSSURE PEAKED AT 10200. INITIATED EMERGENCY DESCENT AT 10000 CABIN ALTITUDE REMAINED AT -450 TO SEA LEVEL CABIN V/S FLUCTUATES BETWEEN -1000FT/MIN TO +14SDR USAA2014051900022Wire Harness · damagedSEAT MOUNTED EMERGENCY EXIT LIGHT AT 24C HAS DAMAGED WIRE HARNESS. REPLACED EMERGENCY EXIT LIGHT WIRE HARNESS AT SEAT 24C.SDR CALA2014051991067Battery · dischargedEMERGENCY LIGHT TEST FAILED. CIDS MSG, EPSU INT LOAD EMER LT & EPSU EXT LOAD EMER LT ATA 33-51-38. REPLACED EMERGENCY BATTERY AT LT OVERWING POWER SUPPLY.SDR CALA2014051991066Warning System · activatedFORWARD CARGO DOOR ECAM ON TAKEOFF ROLL. RETURNED TO BLOCK.SDR CALA2014051991063Door Sill · corrodedL2 DOOR LOWER SILL L2 CORROSION FOUND, FRAME 68 BEAM. REMOVED CORROSION FROM MAIN CABIN L2 SILL BEAM. REPAIRED IAW SRM 53-41-14 REPAIR PRINCIPAL 5.SDR CALA2014051991062Connector · unknownCEILING EMERGENCY LIGHT AT ROW 1 INOPERATIVE. TROUBLESHOOTING CEILING EMERGENCY LIGHT AT ROW 1 FOUND CONNECTOR & OPERATION CHECKED CEILING EMERGENCY LIGHT IAW AMM 33-51-11-400-001-A OPERATIONS CHECKED NORMAL.SDR USAA2014051900023Warning System · activatedCLIMBING THRU FL 200 RECEIVED ECAM FOR HOT NR 1 BRAKE 305. ALL OTHER BRAKES APPROXIMATELY 120 STOPPED CLIMB AT 220, SLOWED 250 KTS, EXTENDED GEAR. ONE BRAKE COOLED, SLOWED TO 220KTS TO RETRACT GEAR. GEAR FAILED TO RETRACT AT 215KTS, SO DESCENDED TO 16,000 FT.SDR USAA2014051900021Wire Harness · unsecureLIGHTING HARNESS WIRING NEEDS TO BE SECURED TO SEAT RAIL AT 26C. REPLACED SEAT PORTION OF EMERGENCY EXIT LIGHT WIRING HARNESS SEAT 26C.
Back to Airbus A320-232