Airbus A320-232
Service difficulty reports · 32,653
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A320232' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A320232' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR YENA20140618113Fan · failedCREW DECLARED AN EMERGENCY AND DIVERTED. DURING CRUISE AT FL 340 NOTICED A STRONG BURNING ELECTRIC ODOR. ODOR DISSIPATED DURING DESCENT. NOTICED CB X18 RECIRCULATING FAN SUPPLY CIRCUIT BREAKER WAS TRIPPED. ACCOMPLISHED TSM 24-00-00-810-823A AND TSM 05-50-00SDR YENA20140618112Secu · failedCREW DECLARED AN EMERGENCY, FLIGHT CONTROL AILERON SERVO FAULT UNCOMMANDED PITCH, AILERON FLUTTER. PERFORMED TSM 27-10-00-810-824A AND TSM 27-93-00-810-918A. R & R NR 1 ELAC AND NR 2 SEC WORKED IAW 27-93-34 AND 27-94-34. PERFORMED OPS TEST OF ELAC'S AND SECSDR YENA20140618111Computer · failedCREW DECLARED AN EMERGENCY, FLIGHT CONTOL AILERON SERVO FAULT UNCOMMANDED PITCH, AILERON FLUTTER. PERFORMED TSM 27-10-00-810-824A AND TSM 27-93-00-810-918A. R & R NR 1 ELAC AND NR 2 SEC WORKED IAW 27-93-34 AND 27-94-34. PERFORMED OPS TEST OF ELAC'S AND SEC'SDR GTIA2014061701346Light · inoperativeEMERGENCY LIGHTS CAPACITY TEST OF EPSU, 11WL, BITE CHECK SHOWS EMERGENCY LIGHT AFT-LT FAULT. R & R AFT LT LIGHT, OVER WING IAW AMM CH 33-51-15PB401. OPS CHECK GOOD.SDR CALA2014062091313Spar · chafedNUMBER 2 PYLON LOWER SPAR FOUND CHAFED AT LOWER SPAR RIB 5. ACCOMPLISHED REPAIR IAW SRM54-51-12 FIG 202. THIS IS A CAT B REPAIR & REQUIRES SUBSEQUENT INSPECTIONS.SDR CALA2014062091312Spar · chafedNUMBER 1 PYLON LOWER SPAR FOUND CHAFED AT LOWER SPAR RIB 5. ACP REPAIR IAW SRM 54-51-12 FIG 202. THIS IS A CAT B REPAIR & REQUIRES SUBSEQUENT INSPECTIONS.SDR YENA20140617110Mount · crackedDURING SPECIAL DETAILED INSPECTION OF NR 1 ENGINE FWD MOUNT FITTING ATTACHMENT BOLT HOLES AT OTBD LWR ARM COMMON TO LWR SPAR & LWR BOOM, A CRACK INDICATION WAS NOTED. ACCOMPLISHED THE REPAIR OF EDGE DAMAGE AND REPLACED LOWER BOOM, PN D54610024200 TO NR 1 LT PYSDR CALA2014061791300Hydraulic System · lowHYDRAULIC QTY LOW, YELLOW SYS. SERVICED YELLOW HYD SYS AS NEEDED IAW AMM 12-12-00.SDR CALA2014061791299Warning System · false activationNW STEER FAULT DISPLAYED ON UPPER ECAM SCREEN. CYCLED NOSE STEERING SWITCH ON FWD INSTRUMENT PANEL. ACCOMPLISHED BITE OF BSCU 1 & 2 TEST PASSED NO FAULTS DISPLAYED.SDR USAA2014061700008Lens · missingEMERGENCY LIGHT MOUNTED TO ROW 9 LT IS MISSING THE RED LENS. EMER LIGHT RED LENS INSTALLED AT ROW 9 LT.SDR USAA2014061600038Slide Raft · unserviceablePERFORMING ORDER 2514Y110 FOUND CONTACT BETWEEN THE SLIDE RAFT COVER AT DOOR R1 & THE FUSELAGE. NO DAMAGE FOUND. PLACED ON MONITOR, INSPECT EVERY 100 HRS. REPLACED SLIDE AT NEXT HEAVY CHECK. R & R THE R1 DOOR SLIDE RAFT AS REQUIRED IAW JOB CARD 26L00025011SDR USAA2014061600036Slide Raft · unserviceablePERFORMING ORDER 2514Y110 FOUND CONTACT BETWEEN THE SLIDE RAFT COVER AT DOOR R2 & THE FUSELAGE. NO DAMAGE FOUND. PLACED ON MONITOR, INSPECT EVERY 100 HRS. REPLACED SLIDE AT NEXT HEAVY CHECK. R & R ESCAPE SLIDE RAFT IAW JOB CARD 26L00025011.SDR CALA2014061691293Rub Strip · chafedNUMBER 2 PYLON LOWER RUB STRIP FOUND CHAFFED AT RIBS 5 & 10. REPAIRED LOWER SPAR PLATE CNA ANTI- CHAFE IAW SRM54-51-12 P 207 REPAIR 5 BA REQUIRES INSPECTION IAW SRI 54-51-12-2-001-00. INITIAL INSPECTION THRESHOLD TO BEGIN AT 102297 PTT 66543PTC.SDR CALA2014061691292Rub Strip · chafedNUMBER 1 PYLON LOWER RUB STRIP CHAFED BETWEEN RIB 5 & RIB 10. REPAIRED LOWER SPAR PLATE CNA ANTI-CHAFE IAW SRM54-51-12 P207 RPR 5 BA. REQUIRES INSPECTION. INITIAL THRESHOLD TO BEGIN AT 102297 PTT 66453 PTC.SDR USAA2014061600032Lens · missingEMERGENCY EXIT LIGHT COVER AT DOOR 2L IS MISSING. INSTALLED EMER EXIT LIGHT COVER AT DOOR 2L .SDR USAA2014062400019Access Panel · corrodedS2 CHECK LEVEL 2 GALVANIC CORROSION ON RT WING LOWER FUEL PANEL 640JB BETWEEN WING RIB 14 TO 15 & BETWEEN STRINGER 8 TO 11. REPLACED RT WING LOWER FUEL PANEL 640JB IAW SRM 51-72-11.SDR USAA2014061600031Hydraulic Line · looseAIR TURN BACK AFTER LOSS OF HYD SYS. SECURED YELLOW SYS LOOSE HYD LINE ON PTU MANIFOLD IAW AMM 29-13-15-400 & SERVICED YELLOW SYS HYD TO LIMITS IAW AMM 12-12-29-611-001-A WITH APPROX 4 GALLONS OF FLUID. OPERATIONS & LEAK CHECKED OK.SDR YENA20140614108Regulator Valve · failedAIR RETURN TO DEPARTURE DUE TO ENGINE 2 BLEED ABNORMAL PRESSURE DURING CLIMB OUT. R & R BLEED PRESSURE REGULATING VALVE IAW TASKS 36-11-52-000-010-B & 36-11-52-400-010-B, LEAK CHECKED OK.SDR YENA20140614109Switch · failedFLT 1051, AIRCRAFT DIVERTED DUE TO VERY NOTICEABLE ELECTRICAL ODOR IN COCKPIT ONLY. QRH TROUBLESHOOTING UNSUCCESSFUL.NO SMOKE OR VISIBLE ARCHING BEHIND PANEL. ODOR STRONGEST NEAR FLOOR. ODOR BECAME STRONGER AT LOWER ALTITUDE. ACCOMPLISHED TSM 05-50-00-810-SDR CALA2014061691279A/C Pack · inoperativeNUMBER 1 PACK IS INOPERATIVE. INOPED PACK 1 PER MEL 215 2A.SDR CALA2014061391258A/C Pack · inoperativeNUMBER 1 PACK IS INOPERATIVE REF MEL CARD. INOPERATIVE PACK 1 IAW MEL 215 2A.SDR USAA2014061300020Slide · defectivePERFORMING EO 2514Y110 FOUND CONTACT BETWEEN THE SLIDE RAFT COVER AT DOOR R2 & THE FUSELAGE, NO DAMAGE FOUND. PLACED ON MONITOR, INSPECT EVERY 100 HOURS. REPLACED SLIDE AT NEXT HEAVY CHECK. REPLACED THE R2 DOOR SLIDE & VALIDATED THAT IT NO LONGER CONTACTS TSDR USAA2014061300019Slide Raft · defectivePERFORMING EO 2514Y110, FOUND CONTACT BETWEEN THE SLIDE RAFT COVER AT DOOR L2 & THE FUSELAGE, NO DAMAGE FOUND. PLACED ON MONITOR, INSPECT EVERY 100 HRS. REPLACED SLIDE AT NEXT HEAVY CHECK. SUPPLEMENT MX REPLACED THE L2 DOOR SLIDE IAW 26L00025011.SDR USAA2014061300027Unknown · vibrationDURING CLIMB THRU FL280 AT MACH 79 STRONG AIRFRAME VIBRATION IN VERTICAL AXIS, UP & DOWN MOTION, AT APPROX RATE OF 2 - 3 CYCLES PER SECOND, HAD TO SLOW BELOW 280 KNOTS MACH 76 TO STOP MOTION. REPLACED SEALS ON HYD ACCESS PANELS & AFT CARGO DOOR SEALS. REPLACESDR USAA2014061300026Connector · dirtyRETURNED TO FIELD DUE TO NR 1 ENG OIL QTY DROPPED ERRATICALLY. CLEANED OIL QTY INDICATOR CONNECTOR.SDR USAA2014061200016Switch · faultyCABIN EMER LIGHT FLICKERS ON & OFF, STAYS ON STEADY WOULD NOT RESET. REPLACED OVERHEAD EMER LIGHT SWITCH.SDR CALA2014061391257Slide · deployedRIGHT OVERWING SLIDE DEPLOYED. REPLACED RT OVERWING SLIDE IAW AMM 25-62-42-400-001-A. REPLACED RT OVERWING INFLATION RESERVOIR IAW AMM 25-62-46-400-001-A. INSTALLED EMER EXIT HATCH IAW AMM 52-21-11-400-001-A.SDR YENA20140609107Battery Pack · no testDURING MAINTENANCE, EPSU BATTERY FAILED SYS TEST. R & R BATTERY IAW AMM 33-51-38-020-051A. OPS CHECKED GOOD.SDR USAA2014061000002Power Supply · inoperativeEMERGENCY LIGHTS WILL NOT TEST. REPLACED FWD EMER POWER SUPPLY UNIT. OPERATIONS CHECKED GOOD IAW AMM 33-51-00.SDR USAA2014061000001Lens · missingEMERGENCY LIGHT LENS AT ROW 9L IS MISSING. REPLACED EMER LIGHT LENS AT ROW 9L.SDR CALA2014060991250Aileron · malfunctionedRIGHT AILERON DEFLECTED DOWN 2 - 3 SCALE WITH ASSOCIATED ROLL OBSERVED.SDR YENA20140608106Battery Pack · failedDURING MAINTENANCE, NOTED A FAILURE OF BATTERY IAW EPSU 13WL. R & R BATTERY PACK IAW AMM 33-51-38.SDR USAA2014061200020Floorbeam · corrodedS2 CHECK SURFACE CORROSION ON CABIN FLOORBEAM AT FRAME 68, Z-500, -Y765. REPLACED CABIN FLOORBEAM AT FRAME 68, Z-500, -Y765 IAW SRM 51-72-11.SDR CALA2014060991235Oxygen Mask · defectiveCAPTAIN'S OXYGEN HARNESS FAILS TO INFLATE, IS LEAKING. REPLACED CAPTAIN`S O2 MASK, OPERATIONS CHECKED OK.SDR USAA2014060900012Bottle · low pressureDOOR ASSIST BOTTLE PRESS LOW A DOOR 2L. SERVICED DOOR 2L ASSIST BOTTLE TO PROPER CHARGE IAW AMM 52-10-00 -614-001.SDR GTIA2014060501335Tube · rupturedOBSERVER OXYGEN MASK HARNESS TUBING RUPTURED INSIDE FABRIC. R & R OBSERVER OXYGEN MASK IAW AMM 35-12-41. OPS CHECKED GOOD.SDR CALA2014060591217Stringer · corrodedSTRINGER 41R CORRODED BETWEEN FRAME 63 & 64. STRINGER SECTION WAS R & R FROM FACTORY SPLICES AT FRAME 58 TO 64 IAW SRM 51-42-11 PG 7 & PG 25.SDR USAA2014060500004Apu · defectiveODORS REPORTED BY FLIGHT ATTENDANT & SOME PAX AT PUSH BACK & TAKEOFF. REPLACED THE APU IAW NON-ROUTINE 3005363.SDR USAA2014060500001Girt Bar · dirtyDOOR L1 WILL NOT ARM OR DISARM CORRECTLY. CLEANED & LUBED GIRT BAR MECHANISM IAW AMM 52-10-00-100-801A.SDR YENA20140614104Warning Message · activatedCREW DECLARED AN EMERGENCY AND DIVERTED. HYDRAULIC G RESERVOIR LOW LEVEL, LANDING GEAR DOORS NOT CLOSED. HYDRAULIC G RESERVOIR OVERHEAT. R & R LT MLG LOCK STAY ACTUATOR LT HOSE IAW AMM 32-11-23. FUNCTIONAL CHECKED, CHECK OF THE GREEN SYSTEM AFTER POSSIBLESDR CALA2014060591218Lens · missingEMERGENCY EXIT SIGN LENS COVER MISSING AT DOOR 2RT LOWER AFT CORNER. REPLACED LENS COVER AT DOOR 2RT, OPERATIONS CHECKED GOOD.SDR USAA2014060400005Battery · faultedDOOR L1 EMER LIGHTS BATTERY FAULTS. REPLACED EMER LIGHT BATTERY AT DOOR L1.SDR USAA2014060400004Cover · crackedEXIT SIGN COVER AT DOOR 2L IS CRACKED AND WILL NOT STAY IN PLACE. REPLACED EXIT SIGN COVER AT DOOR 2L.SDR CALA2014060591219Pump · faultyENGINE 2 EDP LOW PRESS DISPLAYED. YELLOW RESERVOIR QTY IS DECREASING. EDP & PTU SELECTED OFF IAW QRH. ACCOMPLISHED CHECK OF ALL DPI NONE WERE POPPED & NO METAL FOUND IN FILTER. REPLACED ENG CASE DRAIN FILTER IAW MM29-11-43-000-010-A 13 & REPLACED ENG HYD PSDR CALA2014060591216Skin · damagedRUDDER PN 5547100001400 SN TS-1274 WAS FOUND TO HAVE WATER INGRESS & DISBOND DAMAGE. ACCOMPLISHED ALL REPAIRS IAW ECRA 5541-01046 REV A. WORK ACCOMPLISHED ON WU'S 49575, 49576, 49577, 49578, 49579 & 49580. CURRENT PTT 41377 PTC 17871. REPAIR TO RUDDER SIDSDR USAA2014060300004Lens · missingEMERGENCY LIGHT LENS AT DOOR L1 IS MISSING. INSTALLED EMER LIGHT LENS AT DOOR L1 IAW AMM 33-51-13 PB 0401.SDR YENA20140531105Switch · failedTHE CREW REPORTED DURING DESCENT, EMERGENCY EXIT LIGHTS AND ESCAPE PATH LIGHTING ALL CAME ON. RESET THE EMERGENCY LIGHTS FROM THE COCKPIT UNSUCCESSFUL. R & R BAD EMERGENCY EXIT LIGHT SWITCH IAW TSM 33-51-00-810-881-A. OPS CHECKED GOOD. NO FURTHER DEFECTS NSDR GTIA2014053101327Seal · leakingL1 DOOR HAS A LOUD AIR WHISTLE DURING FLIGHT. FOUND L1 DOOR LOWER COSMETIC SEAL PEELED OFF, SECURED AND LUBE SEAL AS REQUIRED. ACFT PRESSURIZED IAW AMM 21-31-00-710-002-A, OPS TEST OK. NO WHISTLE NOISE NOTED AT THIS TIME.SDR CALA2014060291204Unknown · odorSMELL OF SMOKE PASSING THROUGH 10K FEET ON DEPARTURE. AFT FLIGHT ATTENDANT REPORTED CHIME & LAVATORY SMOKE MSG ON CIDS PANEL. NO HEAT OR VISUAL INDICATIONS OF FIRE.SDR GTIA2014053001326Oxygen Mask · damagedFIRST OBSERVERS OXYGEN MASK HAS HOLE IN HEAD BAND. R & R OXYGEN MASK ASSY IAW AMM 35-12-41.
Back to Airbus A320-232