Airbus A320-232
Service difficulty reports · 32,653
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A320232' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A320232' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2013070804731Line · leakingTHREE TO FOUR CUPS OF WATER FLOWED FROM UNDER COFFEEMAKER IN AFT GALLEY EVERY TIME AIRCRAFT STOPS OR SLOWS. FOUND EVIDENCE OF LEAK UNDER INBOARD COFFEEMAKER. REMOVED AND CLEANED AREA AND TIGHTENED WATER LINE THAT APPEARED TO BE LOOSE. INSTALLED COFFEEMAKER ASDR USAA2013070800018Smoke Detector · false activationLAV E SMOKE DETECTOR ACTIVATED SEVERAL TIMES WITH NO EVIDENCE OF SMOKE OR FIRE. OPS CHECKED LAV E SMOKE DETECTOR IAW TROUBLESHOOTING MANUAL 26-17-00-001-A. CHECKS NORMAL AT THIS TIME.SDR CALA20130708001Computer · faultyELAC 1 FAULT DISPLAYED ON UPPER ECAM SCREEN. F-CTL. SUPPLEMENTAL DATA UPDATE NO PARTS, PCN (482-9572). REPLACED ELAC 1 IAW AMM, CKS OK. PERFORMED CAT 3, CK REF AMM.SDR UALA2013070804733Control Box · failedSTEERING DISCONNECT MESSAGE DISPLAYED AFTER PUSHBACK. R & R NLG LOCKOUT BOX, OPS CHECKED GOOD.SDR UALA2013070804710Sill · corrodedR2 DOOR SILL CORRODED. CORROSION FOUND TO BE OUT OF LIMITS. DOOR SILL REPLACED. MAJOR REPAIR.SDR UALA2013070804709Sill · corrodedL2 DOOR SILL HAS CORROSION. SILL CORROSION FOUND TO BE OUT OF LIMITS. DOOR SILL WAS REPLACED. MAJOR REPAIR.SDR UALA2013070904759Wire Harness · inoperativeROW 34 EMERGENCY PATH LIGHT INOPERATIVE ON SIDE OF SEAT. REPLACED LIGHT WIRE HARNESS.SDR UALA2013070804730Control Unit · malfunctionedBSCU 2 FAILED NLG STEERING TEST. F/O STEERING TILLER REPLACED, DISPLAYS DASHED LINES ON STEERING DATA PAGE. TRIED NEW BSCU, NO HELP. ACCOMPLISHED TSM 32-51-11 WIRING CHECKS AND REINSTALLED BSCU & F/O'S TILLER, ALL TESTS OK IAW AMM.SDR UALA2013070804715Computer · faultyELAC 1 FAULT DISPLAYED ON UPPER ECAM SCREEN. NO PARTS PCN (482-9572) REPLACED ELAC 1 IAW AMM, CKS OK. PERFORMED CAT 3, CK REF AMM.SDR USAA2013070800019Smoke Warning · false activationLEFT AFT LAV SMOKE DETECTOR ECAM WARNING SMOKE CRC. PERFORMED BITE TEST ON SMOKE DETECTION SYS NO FAULT NOTED IAW TASK 26-16-00-710-001-A.SDR USAA2013070800017Smoke Detector · false activationLAV E SMOKE DETECTOR ACTIVATED TWICE IN FLIGHT WATER WAS POURED IN TRASH RECEPTICAL WITH NO EVIDENCE OF SMOKE. PERFORMED OPS CHECK OF LAV E SMOKE DETECTION SYS REF TROUBLESHOOTING MANUAL 26-17-00-710-001-A. OK FOR SERVICE AT THIS TIME.SDR CALA2013082990856Power Supply · faultyDURING COMPLETION OF OPERATIONAL CHECK OF THE EMERGENCY LIGHTING DURING ROUTINE S-C THE PTP DISPLAYED FAULT CODE EPSU UNIT AFT LT. R & R AFT LT EPSU 13WL, OPERATIONS CHECKED GOOD.SDR CALA2013090490970Engine · bird ingestionDUE TO FAN BLADE DAMAGE ON NR 2 ENGINE CAUSED BY BIRD STRIKE. ACCOMPLISHED INSPECTION OF THE FAN BLADES PER AMM TASK 72-31-11-200-010-B 13. FOUND ONE BLADE WITH ALLOWABLE DEFLECTION LIMIT & EVIDENCE OF AN AREA OF 'RUB ON THE ATTRITION LINER.SDR CALA2013082990855Battery Pack · faultyEMERGENCY EXIT LIGHTS TEST SHOWS FORWARD BATTERY MESSAGE. REPLACED FORWARD BATTERY PACK.SDR CALA2013082990854Battery · faultyWHEN PERFORMING 2 SERVICE FOUND EMERGENCY LIGHT BATTERY FAULT. REPLACED BATTERY FOR 12WL IAW AMM 33-51-038-000-001-A.SDR GTIA20130704376Oxygen Mask · unwanted deploy25 DEF, O2 MASKS DROPPED. REPACKED O2 MASKS AT 25 DEF IAW AIRCRAFT MM.SDR YENA20130704139Fan · failedDURING CLIMB, TEMPORARY ELECTRICAL ODOR WAS NOTICED IN COCKPIT AND CABIN. PERFORMED ELECTRICAL BURN ODOR INSPECTION IAW TSM 24-00-00-810-823A, FOUND CABIN NR 1 RECIRCULATION FAN CIRCUIT BREAKER X18 TRIPPED. REMOVED & INSTALLED A NEW RECIRCULATION FAN ASSY ISDR USAA2013070500007Shear Pin · brokenMX REPORTED L1 DOOR ASSIST BOTTLE SHEAR PIN BROKEN. MX REPLACED BROKEN SHEAR PIN ON ASSIST BOTTLE L1 AS REQUIRED.SDR USAA2013070500005Battery · dischargedCREW REPORTED THE F/A AFT FLASHLIGHT IS NOT BLINKING. MX R & R AFT F/A FLASHLIGHT BATTERY. OPS CHECK GOOD.SDR USAA2013070500004Reservoir · failedMX REPORTED THE R-2 DOOR ASSIST FAILED DURING OPS TEST OF PASSENGER/CREW DOOR-ESCAPE SLIDE/RAFT. MX REPLACED R-2 DOOR ASSIST RESERVOIR IAW MM 52-13-14-401.SDR UALA2013070304650Stringer · damagedFWD CARGO INTERIOR BILGE AREA STRINGER 42R BETWEEN FR30-31 DAMAGED. R & R STRINGER 42R IAW SRM 51-42-11, P7.SDR USAA2013070800025Shear Plate · corrodedLEVEL 2 EXFOLIATION CORROSION ON LT SHEAR PLATE BETWEEN FR69 TO FR70, Y1732. REPLACED LT SHEAR PLATE BETWEEN FR69 TO FR70, Y1732 IAW TYPICAL REPAIR TR320-2528-10-0011G.SDR USAA2013070300012Seal · leakingSY6 CHECK - L2 DOOR DAMPER DOES NOT HOLD PRESSURE. REPLACED DIAPHRAM SEAL OF DAMPER IAW AMM 52-10-00-610-001.SDR UALA2013070504674Fan · failedAMBER FAN INDICATION ON ECAM CONDITION PAGE. LOCKED OUT RT FAN CIRCUIT BREAKER ON ACCOUNT OF TRIPPING TWICE. CIRCUIT BREAKER DOES NOT POWER ANYTHING ELSE IAW AWM.SDR UALA2013070304663Oxygen Box · no testCAPTAIN`S OXYGEN BOX WILL NOT TEST. REPLACED OXYGEN BOX, OPS CHECKED GOOD IAW MM.SDR USAA2013070500021Floorbeam · corrodedSY6 CHECK. CABIN FLOORBEAM CORRODED AT FR 66 AND Y -1292. R & R BEAM IAW SRM 51-42-11.SDR USAA2013070500020Shear Plate · corrodedSY6 CHECK. CABIN FLOOR SHEAR PLATE CORRODED BETWEEN FR 69 & FR 70 AT Y 1732. R & R SHEAR PLATE IAW TR 320-2528-10-001163.SDR USAA2013070500019Web · corrodedSY6 CHECK. CABIN FLOOR WEB CORRODED FR 20 AND Y 62. R & R WEB IAW SRM 51-42-11.SDR USAA2013070500018Floorbeam · corrodedSY6 CHECK. CABIN FLOORBEAM CORRODED AT FR 68 AND Y 1732. R & R BEAM IAW SRM 51-42-11, SRM 51-42-211/2.SDR USAA2013070500017Floorbeam · corrodedSY6 CHECK. CABIN FLOORBEAM CORRODED BETWEEN FR 68 AND FR 69 AT Y -1292. R & R BEAM IAW SRM 51-72-11.SDR USAA2013070500016Shear Plate · corrodedSY6 CHECK. CABIN FLOOR SHEAR PLATE CORRODED BETWEEN FR 69 & FR 70 AT Y -1732. R & R SHEAR PLATE IAW TR320-2528-10-0011G.SDR USAA2013070500015Floor Support · corrodedSY6 CHECK. CABIN FLOOR SUPPORT CORRODED AT FR 16 AND Y 254. REPAIRED SUPPORT IAW SRM 53-00-14, FIG 206 AND SRM 51-42-11.SDR USAA2013070500014Floorbeam · corrodedSY6 CHECK. CABIN FLOORBEAM CORRODED BETWEEN FR 66 AND FR 68 AT Y -1162.5. R & R BEAM IAW SRM 51-72-11.SDR USAA2013070500013Shear Plate · corrodedSY6 CHECK. CABIN FLOOR SHEAR PLATED CORRODED BETWEEN FR 69 AND FR 70 AT Y -1732. R & R SHEAR PLATE IAW TR320-2528-10-0011G.SDR USAA2013070500011Diaphragm · leakingMX REPORTED THE L2 DOOR DAMPER DOES NOT HOLD PRESSURE. MX R & R DIAPHRAGM SEAL OF L2 DOOR DAMPER PERCUSSION MECHANISM AND SERVICED WITH NITROGEN (BOTTLE HELD PRESSURE) IAW AMM 52-10-00-610-001.SDR YENA20130703138Pilot Valve · leakingCREW DECLARED AN EMERGENCY. CAPTAIN REPORTED A GREEN SYS HYD LOW PRESSURE IN FLIGHT WITH HYD-G RESERVOIR LO LEVEL ECAM MESSAGE. FOUND PILOT VALVE HAD A CRACK AT LANDING GEAR SAFETY VALVE 49GA. R & R VALVE IAW AMM 32-31-00-710. LEAK AND OPS CKS GOOD.SDR UALA2013070304661Threshold · misinstalledL2 DOOR PRODUCING A LOUD SQUEAL FROM SURFACE TO FL 350. STOPPED SQUEAL ON DESCENT AT FL 310. FOUND NEW THRESHOLD PLATE INSTALLED WITH EDGES BENT UP CAUSING LARGE BUMP, STRAIGHTENED IAW MT N52-020.SDR UALA2013070304651Stringer · corrodedFWD CARGO STRINGER 40R BETWEEN FR30-31 CORRODED. STRINGER 40R SPLICED AND REPLACED IAW SRM 53-21-13, FIG 204.SDR GTIA20130702374Bottle · low pressureR2 DOOR ASSIST BOTTLE REQUIRES SERVICING. R2 DOOR ASSIST BOTTLE SERVICED IAW AIRCRAFT MM.SDR UALA2013070504688Cids · malfunctionedEMERGENCY CALL GOES OFF WITHOUT CREW INTERACTION. REPLACED CIDS 2 DIRECTOR.SDR UALA2013070304662Exhaust Duct · crackedNR 1 ENGINE EXHAUST TAILCONE HAS A CRACK APPROX 6 INCHES LONG AT THE 3 O'CLOCK POSITION FWD EDGE. FOUND A CRACK AT 9:00 POS THAT IS "Y" SHAPED WITH LEGS MEASURING 3.5 X 3.5X 2.5 INCHES FOR A TOTAL OF COMBINED LENGTH OF 9.5 INCHES. FOUND CRACK AT 3:00 POS AT SDR UALA2013070304660Drive Assy · failedWEATHER RADAR MAKES A NOISE AND VIBRATES COCKPIT FLOOR WITH EACH PASS. REPLACED DRIVE UNIT IAW AMM, OPS CHECKED GOOD. BITE TEST OK.SDR UALA2013070304649Fairing · crackedNOSE CONE NR 2 ENGINE CRACKED. CRACK IN FAIRING ASSY. FROM 1 BOLT HOLE ALL THE WAY THRU TO THE REAR EDGE, OUT OF LIMITS IAW AMM. REPLACED INLET CONE FAIRING IAW AMM.SDR USAA2013070300009Lens · missingCLEAR COVER HAS COME OFF EXIT LIGHT AT DOOR 2L. REPLACED EMERGENCY EXIT LIGHT LENS.SDR UALA2013070204607Stringer · corrodedAFT CARGO BAY STRINGER 42L CORRODED AT FR 57. REPLACED STRINGER FROM FR53 TO FR 60 IAW SRM.SDR YENA20130701137Skin · corrodedDURING HEAVY MX VISIT, LT WING T/E TOP SKIN ON RIB 74 OTBD OF NR 1 SPOILER ACTUATOR FITTING CORRODED. REMOVED ALL CORROSION BY BLENDING. ACCOMPLISHED DETAIL VISUAL INSP AND HFEC. FABRICATED SHIM WASHERS, RECUT HOLES AND COUNTERSINK TO SUIT FASTENERS. APPLISDR GTIA20130701371Bottle · low pressureR2 DOOR ASSIST BOTTLE LOW PRESSURE. R2 DOOR ASSIST BOTTLE SERVICED IAW AMM.SDR UALA2013070104581Proximity Sensor · failedMULTIPLE ECAM FAULTS AFTER A-C ARRIVAL. SWINGS REPORTED FAULTS OCCURED DURING POWER SWAP? ECAM FAULTS. LG CUI 2, REVERSER 2, MAIN GALLEY SHED, MAINT MESSAGE ENG 2 EIU, OVERHEAD PBSW FAULT LIGHTS ENG2 YELLOW HYD, BLUE HYD SYS, ENGINE INDICATIONS WITH FADAC OSDR UALA2013070204619Oil Cooler · leakingNR 1 ENGINE OIL COOLER LEAKING. PER MT 79-007, RAN NR 1 ENG AND FOUND THE LOWER AFT CORNER OF THE OIL COOLER TO BE LEAKING OIL AT 12-15 DROPS PER MINUTE. OIL COOLER REPLACED. LEAK CHECKED GOOD, NO MESSAGES.SDR UALA2013070104580Solenoid Valve · faultyREGULATE LOW PRESSURE DISPLAYED ON DOOR-OXY SYS ECAM PAGE -DOOR-OXY. REPLACED LP OXYGEN SUPPLY SOLENOID VALVE.
Back to Airbus A320-232