Airbus A320-232
Service difficulty reports · 32,653
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A320232' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A320232' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2013070104599Handset · malfunctionedAFT F/A HANDSET MAKING NOISE. REPLACED HANDSET AT L2 DOOR. OPS CHECKED OK.SDR GTIA20130630369Proximity Switch · faultedR1 DOOR ECAM CAME ON FOR A FEW SECONDS IN CRUISE. R & R PROXIMITY SWITCH (13WV2) R1 DOOR IAW AMM. R1 DOOR SYS WARNING OK.SDR UALA2013070204622Bottle · reads lowR1 DOOR DOOR ASSIST BOTTLE PRESSURE NOT IN LIMITS, LOW. SERVICED ASSIST BOTTLE.SDR UALA2013070204621Bottle · reads lowL2 DOOR OPEN ASSIST BOTTLE PRESSURE NOT IN LIMITS, HIGH. SERVICED ASSIST BOTTLE.SDR UALA2013070104579Control Unit · faultyAFT CABIN, LAVATORY TOILET WILL NOT FLUSH. AFT LAV VACUUM SYS IS INOP ON GROUND. WATER ENTERS BOWL NORMALLY WHEN FLUSHED. LAV FCU IS NOT TURNING ON VACUUM. VERIFIED WHEN OTHER LAV FLUSHES THIS LAV WILL FLUSH.SDR UALA2013070104578Starter · failedRAMP REPORTED SPARKS FROM NR 1 ENGINE DURING START. INSPECTED AREA, NO DAMAGE NOTED TO AREA OR NR 1 ENGINE COWLS, FOUND METAL CHARDS HANGING FROM STARTER. R & R NR 1 STARTER AND START VALVE IAW AMM, OPS CHECKED GOOD.SDR UALA2013070104577Fastener · looseNR 1 NACELLE PATCH, HAS A LOOSE RIVET AT 6 O'CLOCK JUST AFT OF INLET LIP.SDR UALA2013070104571Access Panel · damagedRT WING FUEL PANEL 640QB, SCRE HOLE FOUND MIS-DRILLED. REPAIRED 1 EA MISDRILLED HOLE RT WING PANEL 640QB LANDING IAW ECRA 5720-02416.SDR USAA2013070100011Megaphone · brokenAFT MEGAPHIONE HANDLE LOOSE AND DETACHING. REPLACED MEGAPHONE.SDR UALA2013070104559Landing Gear · vibrationEXCESSIVE NOSE WHEEL VIBRATION ON TAKEOFF ROLL FROM 80 KIAS THROUGH GEAR RETRACTION. R & R BOTH NOSE WHEEL ASSY IAW AMM. TIRE PRESSURE CHECKED GOOD.SDR UALA2013070104558Processor · malfunctionedHAD A 3400 LB FUEL IMBALANCE WITH 7500 IN CENTER TANK. BALANCED AND WHEN CENTER TANK EMPTY HAD 800 IMBALANCE. FUEL IMBALANCE CONTINUED. LEFT HAD A HIGHER FUEL BURN AND ALL PUMPS SEEM OK. LEFT SIDE WAS HEAVY SIDE WHICH IS CONTRARY TO LEFT ENGINE BURN. ACCOSDR UALA2013070104560Cap · damagedSECOND REPORT ON SEAT 20F INDICATES PHYSICAL DAMAGE TO SEAT ARM. MADE INTERIM REPAIR WITH TAPE. DAMAGED ARMCAP IS AT 20F, LT SIDE WHICH HOLDS PCU. REPLACED ARMCAP.SDR UALA2013070104551Access Panel · damagedLT FUEL PANEL 540LB BETWEEN RIBS 16-17 HAS SEVEN ELONGATED HOLES IN TANK LANDINGS. REPAIRED FOUR HOLES IAW SRM 57-21-11, REPAIRED THREE HOLES IAW ECRA 5720-02415 REV A.SDR UALA2013070104547Power Supply · faultyDURING EMERGENCY LIGHT TEST, EPSU INT LOAD EMERGENCY LIGHT FAILURE MESSAGE. REPLACED LT CABIN EMERGENCY EXIT POWER SUPPLY IAW MM, TESTS OK.SDR USAA2013070100009Accumulator · low pressurePAX DOOR R2 ASSIST ACCUMULATOR PRESSURE IS LOW. SERVICED R2 DOOR ASSIST ACCUMULATOR IAW AMM 52-10-00-010-001-A.SDR USAA2013070100008Accumulator · low pressurePAX DOOR 2L DOOR ASSIST ACCUMULATOR PRESSURE IS LOW. SERVICED 2L DOOR ASSIST ACCUMULATOR IAW AMM 52-10-00-010-001-A.SDR UALA2013062804541Control Panel · faultyFUEL MIGRATING FROM WING TANKS TO CENTER TANK. FOUND CHANNEL 2 OF FQIC INTERMITTENTLY BLANKING ALL X'S. ALSO INCORRECT ECAM DISPLAY WITH ONE CHANNEL FAILURE. BITE CHECKED OK. REPLACED FQIC.SDR UALA2013062804540Insulator · missingBMC2 TEST FAILED. MESSAGE RT WING LOOP "B" INOPERATIVE AFTER REPLACING "B" LOOP 79HF. REPLACED MISSING SOCKET INSULATOR, CONNECTOR AT 64HF REF AMM. BMC2 TEST NORMAL.SDR UALA2013062804537Relay · faultyF/A REPORTED AFT CIRCUIT BREAKER PANEL MAKES CLICKING NOISE AND CHILLERS CYCLING ON AND OFF. CHILLER M31 CYCLING ON & OFF. VERIFIED AWM 25-33-01, SHEET 1 & FOUND TR 9010ML3 FAULTY. REPLACED TR 9010ML3, NO HELP. STILL CLICKING ON AND OFF. INSTALLED NEW CHSDR UALA2013070104548Light · inoperativeEMERGENCY LIGHT ASSY AT SEAT 28 FOUND INOPERATIVE. R & R EMERGENCY LIGHT ASSY AT ROW SEAT 28, OPS CHECKED GOOD.SDR UALA2013062804539Computer · failedAVIONICS SMOKE ECAM, AEVC INSTALLED AND TESTED IAW AMM 21-26-34.SDR YENA20130627135Epsu · failedDURING MX , EMERGENCY LIGHT SYS FORWARD EPSU UNIT FAILED TO TEST. R & R FWD EPSU AT POSITION 10WL, IAW AMM 33-51-38. EMERGENCY LIGHT SYS TESTED OK.SDR UALA2013062604464Door · faultyLIFE JACKET DOOR ON CENTER OBSERVERS SEAT WILL NOT REMAIN CLOSED. R & R CREW LIFE VEST. DOOR STAYS CLOSED.SDR UALA2013062704481Ignition Unit · inoperativeAPU WILL NOT CRANK ON START. TROUBLESHOT IAW TSM 49-40-00. R & R IGNITION UNIT REF AMM 49-41-38. OPS NORMAL.SDR UALA2013062704482Window · delaminatedFIRST OFFICER`S SIDE WINDOW HAS DELAMINATION. FOUND DELAMINATION AT 3 INCHES IN AREA B. DELAMANATION AT 3 INCHES IN AREA B. FIRST OFFICER`S NR 3 WINDOW REPLACED.SDR UALA2013062704480Oxygen Mask · unwanted deployOXYGEN MASKS AT ROW 8 ABC DROPPED.SDR UALA2013062604460Actuator · no testOXYGEN MASK FOR F/A AT L1 DOOR FAILED DEPLOYMENT TEST. REPLACED ACTUATOR AND ACCOMPLISHED NEW DROP TEST. OK IAW 35-23-00-710-001-A.SDR USAA2013062700010Power Supply · inoperativeEMERGENCY LIGHTS AT ROWS 3 AND 7 INOP. RELAMP NO HELP. R & R EMERGENCY LIGHT BATTERY AND POWER SUPPLY.SDR UALA2013062604467Wire Harness · inoperativeEMERGENCY LIGHT AT 11 ABC INOPERATIVE. REPLACED EMERGENCY LIGHT HARNESS. OPS CHECKED GOOD, IAW AWM 33-51-06.SDR UALA2013062704483Actuator · failedFUEL TRANSFER FM RIGHT OTBD TIP TO MAIN TANK AFTER FUELING. SUSPECT AFT VALVE ACTUATOR. REPLACED RT AFT INTERCELL TRANSFER VALVE ACTUATOR IAW AMM. OP CHECKED AMM 28-15-00-710-002A, OPS NORMAL.SDR GTIA20130625364Slide · underservicedREMOVED L1, DOOR ESCAPE PACK-ASSY FOR MX. RE-INSTALLED L1 ESCAPE SLIDE RAFT PACK ASSY PER ACFT MM, OPS TEST OK.SDR GTIA20130625363Cylinder Damper · low pressureR2 DOOR ASSIST BOTTLE REQUIRES SERVICING. SERVICE R2 DOOR ASSIST BOTTLE TO PROPER LEVEL IAW AIRCRAFT MM. OPS CK OK.SDR UALA2013062604462Warning Light · illuminatedOXY LOW PRESS REGULATOR. REPLACED OXY PRESS REGULATOR. NO HELP.SDR UALA2013062604459Oxygen Mask · missingOXYGEN MASK MISSING FROM OXYGEN BOTTLE OVER 1A. REPLACED OXYGEN MASK ON OXYGEN BOTTLE.SDR UALA2013062604452Microphone · inoperativeF/O OXYGEN MASK MICROPHONE INOPERATIVE, IN HOT-MIC FUNCTION. REPLACED F/O OXYGEN MASK IAW AMM, OPS CHECKED GOOD.SDR UALA2013062604451Switch · inoperativeFIRST OBSERVERS SEAT, CREW OXYGEN PRESS TO TEST, DOESN`T TEST.SDR UALA2013062604446Battery Pack · inoperativeEMERGENCY LIGHT TEST AT L1 DOOR ATTENDENT PANEL FAULTED. REPLACED EMERGENCY LIGHT RT WING BATTERY PACK, GROUND TESTED OK.SDR UALA2013062604436Isolation Valve · leakingTOTAL LOSS OF GREEN HYD SYS. SHUTOFF GREEN PUMP AS SOON AS "LO LVL ECAM" APPEARED. REPLACED THRUST REVERSER HYDRAULIC ISOLATION VALVE FILTER C-RING, OPS AND LEAK CHECKED GOOD. HYD FLUID LOSS WAS 50 PERCENT.SDR UALA2013062504420Access Door · dentedTWO DENTS FOUND IN HP AIR ACCESS DOOR ON ARRIVAL.SDR USAA2013062600003Power Supply · malfunctionedDURING WEEKLY EMERGENCY LIGHT TEST, RECEIVED MESSAGE "ESPU INT LOAD EMER RT, EMER LT, AFT LT". RESET EACH PSU AT OVERWING LT, RT AND AFT GALLEY IAW TROUBLESHOOTING MANUAL 33-51-00-810-807-A, OPS CHECKS GOOD. OTHER SN'S 1421, 2736.SDR YENA20130625133Servo Control · failedCREW DECLARED AN EMERGENCY DUE TO WHEEL NWS FAULT IN FLT. RESET NOSE WHEEL STEERING SWITCH ON GROUND UNSUCCESSFUL. R & R NOSE WHEEL SERVO CONTROL IAW AMM 32-51-51. OPS AND LEAK CHECKED OK.SDR UALA2013062604450Line · leakingRESERVOIR LOW AIR PRESSURE ECAM, RETURNED TO FIELD. TOTAL TIME FROM FLUID LOSS TO GREEN PUMP SWITCH OFF LESS THAN 2 MINUTES. FOUND HYD LINE LEAKING ON MLG DOOR ACTUATOR. REPLACED LINE. SERVICED GREEN SYSTEM TO FULL . REPLENISHED HEAD PRESS AND BLED SYSTEMS SDR UALA2013062604468Door · missing1 COCKPIT CREW LIFE VEST MISSING. DOOR FOR LIFE VEST MISSING FROM SECOND OBSERVER SEAT. THIS IS THE SEAT BEHIND THE CAPTAIN'S SEAT. SEAT IS NOT TO BE USED. REPLACED VEST.SDR UALA2013062604466Lens · damagedL1 DOOR SLIDE PACK VIEW PORT OBSTRUCTED. FOUND LENS HAZED. REMOVED AND REPLACED LENS, SLIDE BOTTLE PSI CAN BE VERIFIED AS NORMAL.SDR UALA2013062604457Skin · dentedMULTIPLE DENTS ON LEFT OTBD T/E FLAP. FILLED DENTS.SDR UALA2013062604456Skin · dentedMULTIPLE DENTS ON LEFT INBOARD TRAILING EDGE FLAP. DENTS FILLED AND CURED.SDR UALA2013062604455Skin · dentedMULTIPLE DENTS ON RT INBD T/E FLAP. ALL DENTS FILLED AND CURED.SDR UALA2013062604454Extinguisher · dischargedENGINE FIRE EXTINGUISHER DISCHARGED LIGHT OF "AGENT 1" ILLUMINATED WITHOUT FIRING BOTTLE 1. R & R NR 1 ENGINE FIRE EXTINGUISHING BOTTLE IAW MM.SDR UALA2013062604447Door · detachedCAPTAIN`S OXYGEN MASK DOOR FELL OFF. REPLACED DOOR ASSY.SDR UALA2013062504419Battery Pack · failedEMERGENCY LIGHT TEST AT L1 DOOR ATTENDANT PANEL FAULTED, BATTERY EMERGENCY LIGHT RT WING. REPLACED EMERGENCY LIGHT BATTERY PACK. GROUND TESTED OK.
Back to Airbus A320-232