SDR UALA2013061804217Latch · out of adjustOVERWING EXIT LANYARD DOOR, LT SIDE, POPS OPEN. ADJUSTED STOW BIN LATCH FOR OVER WING EXIT LANYARD, OPS CHECK NORMAL.SDR UALA2013061804215Strap · out of positionCAPTAIN'S OXYGEN HARNESS FAILS TO INFLATE (IS LEAKING). CAPTS O2 MASK WHEN DONNED IS VERY LOOSE AND WON'T STAY SECURED. NO LEAK NOTED BY CAPTAIN. FOUND MASK CROSS STRAPS INCORRECTLY POSITIONED. REPOSITIONED STRAPS, MASK OPS CHECKED OK.SDR UALA2013061804213Fan · noisyAFT CARGO EXTRACTION FAN MAKING VERY LOUD NOISE. DEACTIVATED AFT CARGO EXTRACTION FAN BY PULLING OPEN CB AFT CARGO VENT & HEATING CONTROL CB ON PANEL 122VU S22. PARTS: 565-9012, MR21270. (FAN)SDR UALA2013061804221Cover · misinstalledL1 DOOR EMERGENCY EXIT LIGHT APPEARS TO BE IMPROPERLY INSTALLED. REPOSITIONED EMERGENCY EXIT LIGHT COVER.SDR UALA2013061804226Latch · damagedDURING DROP TEST, AFT FWD LAVATORY OXYGEN MASK COMPARTMENT WILL NOT LATCH CLOSED. REPAIRED FWD AFT LAVATORY OXYGEN STORAGE BOX LATCH. PERFORMED TASK 35-23-00-710-001-A. OPS CHECK OF MANUAL MASK RELEASE. CHECKED OK.SDR UALA2013061704176Cover · misinstalledL2 DOOR SLIDE COVER DOES NOT APPEAR TO BE INSTALLED CORRECTLY. INSTALLED DOOR SLIDE COVER REF AMM 25-62-44.SDR UALA2013061904233Skin · damagedRIGHT WING TANK LANDING FOR PANEL 640NB HAD ONE HOLE REPAIRED IAW SRM. REPAIR REQUIRES GENERAL VISUAL INSPECTION EA 3600C OR 4500T WHICHEVER OCCURS FIRST IAW SRI 57-21-11-2-002-00, TBL 203. NOTE: ACFT HAS EXCEEDED ORIGINAL INSP CRITERIA OF 54,600 T. BY- 0866SDR UALA2013061904232Panel · damagedRT WING TANK LANDING FOR PANEL 640KB HAS 1 BOLT HOLE REPAIRED IAW SRM. REPAIR REQUIRES GVI INSPECTION EA 3600C OT 4500 T WHICHEVER COMES FIRST IAW SRI 57-21-11-2-002-00 TBL 20. NOTE: INITIAL INSP CRITERIA OF 54,600 T HAS BEEN EXCEEDED.SDR UALA2013061804227Shield · damagedCAPTAIN'S OXYGEN FACE SHIELD IS DAMAGED. REPLACED CAPTAIN'S OXYGEN FACE SHIELD IAW AMM.SDR UALA2013061804211Power Supply · failedEMERGENCY LIGHT BITE FAILS LT EPSU AND AFT BATTERY. REPLACED LT EPSU AND BATTERY AND AFT BATTERY. CHECKS OK.SDR USAA2013061800005Lens · missingDOOR 1R EMERGENCY EXIT COVER MISSING. REPLACED 1R DOOR EMERGENCY EXIT LENS COVER.SDR CALA2013082790801Bottle · unknownCABIN INTERPHONE DISTRIBUTION SYSTEM PANEL LIGHT ON. INTERROGATED PTP PANEL SHOWS LT OVERWING EXIT BOTTLE PRESSURE. FOUND BOTTLE PRESSURE TWO NEEDLES IN THE GREEN. REPLACED LEFT OVERWING SLIDE INFLATION RESERVIOR PER AMM.SDR UALA2013061704174Scuff Plate · tornTEAR IN METAL AT THRESHOLD OF FWD CARGO BAY, ABOUT 6-8 INCHES LONG. REMOVED AND REPLACED FWD CARGO BAY INBD SCUFF PLATE.SDR UALA2013061804218Unknown · odorF/A SMELLED SMOKE IN AFT GALLEY COMING FROM AIR VENT OVER GALLEY TABLE, NO OVEN IN BACK. THERE WAS NO VISIBLE SMOKE REPORTED BY FA. APPEARS TO HAVE EMANATED FROM COFFEEMAKERS, BURNED COFFEE ODOR. PULLED COFFEEMAKERS OUT AND INSPECTED, NO DEFECTS NOTED. CLEANSDR UALA2013061704189Panel · damagedPANEL BELOW CONTROL STICK ON CAPTAIN`S SIDE DAMAGED. REPAIRED PANEL.SDR UALA2013061704171Bottle · unknownF/A SAYS CIDS PANEL LIGHT ON. INTERROGATION OF PTP PANEL SHOWS LT OVERWING EXIT BOTTLE PRESSURE. FOUND BOTTLE PRESSURE NEEDLES IN THE GREEN. REPLACED LT OVERWING SLIDE INFLATION RESERVOIR IAW AMM. ACCOMPLISHED FINAL INSTALLATION CHECK. BITE TEST OK.SDR UALA2013061804212Cover · unsecureR2 DOOR SLIDE COVER LOOSE. R2 SLIDE PACK COVER FELL OFF. REINSTALLED.SDR UALA2013061704188Acoustic Liner · damagedHOLE IN ACCOUSTIC LINING ON NR 2 ENGINE.SDR UALA2013061704187Skin Panel · delaminatedPANEL AFT OF DOUBLE DRAINS ON FWD FUSELAGE L/E EXPOSED AND SCREW PULLING THRU-POS DELAMINATED. APPLIED SPEED TAPE IAW MT 53-00-02, PANEL MUST BE REPLACED WITHIN 300 HOURS.SDR UALA2013061704173Light · missingEMERGENCY SEAT LIGHT AT 24C MISSING BASE AND LENS, AISLE SIDE. INSTALLED LIGHT ASSY, LIGHT OPS CHECKS GOOD.SDR YENA20130616127Line · leakingCREW DECLARED AN EMERGENCY DUE TO BLUE HYD QTY LOW, NORMAL PSI NO ECAM INDICATION. FOUND AILERON ACTUATOR LINE LEAKING, R & R LINE IAW AMM 27-14-00. OPS CHECK BLUE SYS NORMAL ,UPON FILLED NO ECAM MSG NOTED.SDR YENA20130616126Bolt · missingDECLARED AN EMERGENCY DUE TO EXCESSIVE VIBRATION ON LANDING CONFIGURATION WITH FLAPS TO FULL. DURING WALKAROUND FOUND ACTUATOR FOR LT WING NR 1 SPOILER, WITH EYE END PISTON ROD MISSING SPECIAL BOLT AT NR 1 SPOILER ATTACHMENT BRACKET. AS PRECAUTION R & R LT WSDR UALA2013061804224Insulator · missingFIRE LOOP B FAULT DISPLAYED ON UPPER ECAM SCREEN. NR 2 ENGINE POST FLIGHT CLEANED, REPLACED MISSING INSULATORS ON FAN CORE LOOP. CHECKED GOOD.SDR UALA2013061804222Girt Bar · dirtyR2 DOOR DIFFICULT TO ARM. FOUND DEBRIS IN GIRT BAR AREA. CLEANED. DOOR ARMS AND OPS CHECKED NORMAL.SDR USAA2013061700009Sign · brokenROW 10 RT EMERGENCY EXIT SIGN BROKEN. REPLACED LIGHT LENS AT ROW 10 LT.SDR UALA2013061704158Latch · damagedONE FUEL PANEL LATCH INBD, DAMAGED. REPLACED LATCH.SDR UALA2013061804223Control Unit · faultedCLASS 2 MX MESSAGE, SDCU ON LOWER ECAM DISPLAYED, LAST SDCU REPLACED ON MAY 31, SUSPECT BAD UNIT. REPLACED SDCU IAW MM 26-17-34. ALL GROUND CHECKED GOOD.SDR UALA2013061704159Skin · dentedDENT IN FUSELAGE BELOW DOOR 2L, 1.250 LENGTH, .750 WIDTH, .031 DEPTH. DAMAGE IS LOCATED BETWEEN FR 69-70 AND STR 32-33. ACCOMPLISHED VISUAL INSPECTION, NO CRACKS. FOUND DAMAGE IS WITHIN ALLOWABLE LIMITS IAW SRM 53-41-11, DIAGRAM 103, PG 163.SDR UALA2013061804214Hose · kinkedF-O OXY PRESS TO TEST NOT SHOWING YELLOW CROSS HAIRS WHEN PRESSED. REMOVED KINK FROM HOSE TO MASK. OPS CHECKS GOOD.SDR UALA2013061704156Seat · unsecureSEATS AT ROW 37 ABC, LOOSE. SECURED SEATS AT ROW 37 ABC OK TO CONTINUE.SDR UALA2013061404128Rivet · looseNR 1 ENGINE NOSE COWL REPAIR APPEARS TO HAVE MULTIPLE LOOSE RIVETS. APPROX 3 O'CLOCK POSITION. R & R LOOSE RIVETS, ACFT OK FOR SERVICE.SDR UALA2013061704157Unknown · malfunctionedDURING REFUEL, FUEL MIGRATED TO INNER TANKS WITH TRANSFER VALVES SHOWN CLOSED ON FUEL PAGE. POSSIBLE TRANSFER VALVE SHAFT SHEARED.SDR UALA2013061404130Screw · missing2 SCREWS MISSING FROM L/E LT WING. REPLACED MISSING SCREWS.SDR UALA2013061404129Screw · missingON WALK AROUND FOUND FASTENER PROTRUDING FROM CENTER WING-TO-BODY FAIRING JUST FORWARD OF EXTERNAL AC PANEL. SCREW MISSING. TAPE OVER MISSING FASTENER IAW AMM 53-35-00-601 FOR 10C. PANEL NR 197AR.SDR UALA2013061404127Paint · peelingNOSE RADOME HAS PAINT PEELING ON FRONT MIDDLE PORTION.SDR USAA2013061400004Light · inoperativeSEAT MOUNTED EMERGENCY LIGHT AT 24C-INOPERATIVE. R & R SEAT MOUNTED EMERGENCY LIGHT ASSY AT 24C IAW MM 33-51-18.SDR UALA2013061304063Valve · failedNLG STRUT REPORTED FLAT WITH NO FLUID LEAKAGE. REPLACED NLG CHARGE VALVE AND O-RING AND ACCOMPLISHED NLG STRUT SERVICE REF AMM 12-12-32. NO ACTIVE LEAKS.SDR UALA2013061304066Seal · missingLEFT SIDE L/E SLAT TO BODY FAIRING SEAL MISSING 6 INCHES. REPLACED SEAL ON LT LEADING EDGE SLAT TO BODY FAIRING.SDR UALA2013061304065Computer · failedSIDE STICK PRIORITY DISPLAYED ON UPPER ECAM SCREEN. REPLACED ELAC1 & ELAC 2 IAW AMM 27-93-34, RETURNED ACFT TO FULL CAT III CAPABILITY AFS AND LAND VERIFICATION TESTS NORMAL, IAW AMM 22-96-00 AND 22-97-00.SDR UALA2013061304061Lever · obstructedR2 DOOR DOES NOT ARM PROPERLY, DIFFICULT TO MOVE ARMING LEVER. CLEANED DEBRIS FROM UNDER R2 DOOR. DOOR OPERATES AND SLIDE ARMS NORMAL. ACFT OK TO CONTINUE.SDR UALA2013061304060O-Ring · leakingLEFT ALTERNATE BRAKE SAFETY VALVE LEAKING. FOUND O-RING LEAKING. REPLACED O-RING, LEAK CHECKED GOOD.SDR USAA2013061700034Floor Panel · delaminated2S CHECK - DELAMINATION ON FLOOR PANEL NR 251XF UPPER SURFACE BETWEEN FR62 TO FR64, S23L, Z-500 & Y1028. REPLACED FLOOR PANEL NR 251XF IAW IRM 9701, REV G.SDR UALA2013061304062Actuator · leakingFOUND RT MLG RETRACT ACTUATOR LEAKING. R & R MLG ACTUATOR IAW AMM.SDR UALA2013061304054Skin · damagedDURING HMV VISIT, REPAIR DOUBLER WITH LESS THAN SRM ALLOWED EDGE DISTANCE WAS INSTALLED & SUBSEQUENTLY REMOVED ON FUSELAGE SKIN FR33-34, STR41L-41R. REPAIRED IAW SRM 53- 21-11, FIG 215.SDR UALA2013061304053Sill · corroded2R DOOR SILL BEAM HAS SPOTS OF CORROSION MIGRATING UNDER FWD GIRT FITTING PLATE, AFTER BLENDING FOUND TO BE OUT OF SRM ALLOWABLE LIMITS. REPAIRED IAW SRM 53-41-14, FIG 201.SDR UALA2013061304052Structure · debondedRT SIDE OF RUDDER HAS A DISBOND INDICATION 18" FROM TOP OF RUDDER AND 14" FROM T/E, 4" IN DIAMETER. CLEANED, PREPPED AND REPAIRED AREA OF DISBOND ON RT SIDE OF RUDDER AND REAPPLIED FINISH AS REQUIRED IAW ECRA 5540-01348.SDR USAA2013061300015Megaphone · brokenMX REPORTED THE FORWARD MEGAPHONE HANDLE BROKEN. MX R & R FORWARD MEGAPHONE IAW AMM 20-11-10.SDR UALA2013061204038Line · leakingMUSTY ODOR IN CABIN & COCKPIT. RAN BOTH PACKS IN FULL COLD FOR 15 MINUTES IAW AMM TASK 21-00-00-615-003-A, STEP 4 W, PGS 43-45. FOUND OIL LINE LEAKING AT PRESSURE SWITCH ON APU. REPLACED OIL LINE . LEAK CHECKED GOOD.SDR UALA2013061304064Line · leakingFOUND OIL LINE ON APU, AFT MID LOWER GEAR CASE TO PRESSURE SWITCH LEAKING OIL WITH APU RUNNING AND BEING INGESTED INTO APU INLET BRAIDED DEFECTED LINE IS MARKED WITH TIED OFF RAG AND PART IS ORDERED AOM C1245 PCN (225-1106). REPLACED OIL LINE. LEAK CHECK GOOD.SDR UALA2013061204036Line · leakingHYD FLUID-DRIPPING CENTER AFT FUSELAGE. TIGHTENED MAIN HYD LINE GOING INTO THE TOP OF THE YELLOW HP MANIFOLD, NO LEAKS NOTED.
Back to Airbus A320-232