Airbus A320-232
Service difficulty reports · 32,653
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A320232' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A320232' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2013061204030Sill · corrodedCORROSION ON L2 DOOR SILL AT FR 68. L2 DOOR SILL REPAIRED IAW SRM 53-41-14, FIG 201, SHEET 3. MAJOR REPAIR.SDR UALA2013061204029Stringer · corrodedCORROSION ON STRINGER 43L BETWEEN FR 33 AND 34. CORROSION FOUND TO BE OUT OF LIMITS. REMOVED STRINGER AND FABRICATED NEW IAW SRM 51-72-11 PG 1 & 2 AND 51-21-11, PG 1,2,3 & 4. INSTALLED STRINGER IAW SRM 51-72-11, PG 1& 2.SDR UALA2013061204028Stringer · corrodedCORROSION ON STRINGER 42L BETWEEN FR 33 AND 34. CORROSION FOUND TO BE OUT OF LIMITS IAW SRM 53-21-13, FIG 102. REMOVED STRINGER AND FABRICATED NEW IAW SRM 51-72-11, PG 1 & 2 & 51-21-11 PG 1, 2, 3, & 4. INSTALLED STRINGER IAW SRM 51-72-11 PG 1 & 2. MAJOR RESDR USAA2013061200021Slide Raft · low pressureAFT LT BOTTLE SHOWS LOW PRESSURE ON SLIDE RAFT (L2) DOOR. R & R AFT LT (L2) SLIDE RAFT.SDR USAA2013061200020Fire Bottle · leakingWATER FIRE EXTINGUISHER LEAKING. REPLACED WATER FIRE EXTINGUISHER.SDR UALA2013061204005Line · leaking"Y RESERVOIR LO LEVEL" DISPLAYED ON UPPER ECAM SCREEN. FOUND HYD LINE LEAKING AT CLAMP. 12 O'CLOCK POSITION, JUST INBD OF HUGE PURPLE HYD CONNECTOR ON ENG NR 2. FOUND LINE UNDER CLAMP WITH CRACKED. REPLACED LINE. SERVICED YELLOW HYD'S AND MOTORED ENGINE,SDR UALA2013061204037Unknown · odorELECTRICAL ODOR IN ACFT, NO DISCERNABLE LOCATION. AFTER EXTENSIVE TROUBLESHOOTING OF ACFT SYSTEMS, NO FAULTS FOUND. ODOR WENT AWAY. THERE ARE NO FAULTS FOUND ON THE ACFT SYS AND AFTER USING APU AND PACKS ODOR WENT AWAY AND HASN'T RETURNED IAW TSM.SDR GTIA20130610349Bottle · low pressureR1 DOOR ACTUATOR BOTTLE PRESSURE LOW. SERVICED DOOR ACTUATOR BOTTLE IAW MM.SDR CALA2013082990822Bottle · low pressureFOUND 1L DOOR ASSIST BOTTLE PRESSURE ZERO. REPLACED DOOR 1L ASSIST BOTTLE.SDR UALA2013061204000Unknown · odorF/A REPORTED ELECTRICAL BURNING ODOR FROM AFT GALLEY DURING TAXI OUT, NO SMOKE. FOUND RT AFT GALLEY CEILING LIGHT BULB INTERMITTENT, REPLACED LAMPS SAME PROBLEM, INSPECTED AREA ABOVE AFT GALLEY IN CEILING AREA, NO EVIDENCE OF OVERHEATED OR BURNED COMPONENTS, NSDR UALA2013061204004Tat Probe · failedADR 1 FAULTED, FLT DIVERTED. REPLACED NR 1 TAT PROBE.SDR GTIA20130609347Oxygen Mask · unwanted deployROW 11 ABC, PSU O2 MASK DEPLOYED. PERFORMED O2 DROP TEST REF ACFT MX MANUAL TEST OK.SDR USAA2013061200028Unknown · odorCABIN ODOR, DIRTY SOCK SMELL, REPORTED BY F/A`S. NO ODOR NOTED.SDR USAA2013061000047Girt Bar · obstructedDOOR 1L WILL NOT ARM. REMOVED PAPERCLIP FROM L1 GIRT BAR.SDR USAA2013061000046Lens · missingFLOOR LEVEL LIGHTING AT SEAT 26C IS MISSING FACE PLATE. REPLACED LENS IAW AMM 33-51-19.SDR UALA2013061103998Liner · damagedNR 2 ENGINE HAS DAMAGE TO ACCOUSTICAL MATERIAL AT THE 5:30 POSITION NEAR NACELLE LIP.SDR UALA2013061103993Structure · damagedRT WING TANK LANDING HAS TWO MISDRILLED HOLES.SDR YENA20130608123Gcu · faultyDIVERTED, DURING CLIMBOUT OF 19,000 FT POSSIBLE LIGHTNING STRIKE. MULTIPLE ELECTRICAL FAILURES. NR 1 GENERATOR , ALL EFIS DISPLAYES WENT BLANK. F/O'S CAME BACK FOLLOWED BY CAPTAINS 1 MINUTE LATER. LIGHTNING STRIKE INSPECTION PERFORMED IAW AMM 05-51-200-001-SDR YENA20130608122Idg · faultyDIVERTED, DURING CLIMBOUT OF 19,000 FT POSSIBLE LIGHTNING STRIKE. MULTIPLE ELECTRICAL FAILURES. GEN NR 1, ALL EFIS DISPLAYES WENT BLANK. F/O'S CAME BACK FOLLOWED BY CAPTAINS, 1 MINUTE LATER. LIGHTNING STRIKE INSP, PERFORMED IAW AMM 05-51-200-001-A, NO STRIKSDR YENA20130608121Battery Pack · faultedDURING MX EMERGENCY LIGHT UNIT FAULTED AT FIN 11WL. R & R BATTERY FOR EPSU IAW AMM 33-51-38. OPS CHECK GOOD.SDR YENA201308121Battery Pack · faultedDURING MX EMERGENCY LIGHT UNIT FAULTED AT FIN 11WL. R & R BATTERY FOR EPSU IAW AMM 33-51-38. OPS CHECK GOOD.SDR CALA2013082790788Life Vest · missingFLIGHT DECK LIFE VEST MISSING. REPLACED COCKPIT LIFE VEST.SDR CALA2013082790786Battery Pack · dischargedDURING CABIN EMERGENCY LITE TEST GOT THE MESSAGES "BATTERY AFT LEFT", "UNIT EMERGENCY RIGHT", & "BATTERY EMERGENCY LEFT". REPLACED BATTERY PACK AT AFT LT DOOR PASSENGER SERVICE UNIT IAW MM, TESTED OKAY.SDR GTIA20130607344Flashlight · no testF/A AFT RT FLASHLIGHT WILL NOT PUSH TO TEST. R & R F/A RT FLASH LIGHT. OPS CHECKED GOOD.SDR USAA2013061000003Lens · missingROW 9R, EMERGENCY LIGHT LENS MISSING. REPLACED ROW 9R EMERGENCY LIGHT LENS AS REQUIRED.SDR USAA2013061000002Battery · dischargedFWD F/A JUMPSEAT FLASHLIGHT INOPERATIVE. REPLACED BATTERY AND SAFETY STRAP ON FORWARD FLASHLIGHT JUMPSEAT POSITION.SDR UALA2013060703960Tire · damagedNR 3 MLG HAS BUBBLE ON INNER BEAD OF THE TIRE. REPLACED NR 3 TIRE IAW AMM 32-41-11-401.SDR UALA2013060703962Oxygen Mask · leakingFIRST OFFICER`S OXYGEN HARNESS FAILED TO INFLATE. SWAPPED F/O`S MASK WITH OBSERVERS MASK . CHECKED OK. REPLACED OBSERVERS MASK.SDR UALA2013060603948Battery · failedEMERGENCY LIGHT TEST FAILED ON 2 SVC. REPLACED BATTERY IAW MM 33-51-38.SDR UALA2013060603953Servo · malfunctionedLEFT AILERON FAILED FREE PLAY CHECKS WITH INBD OR OTBD SERVOS ACTIVE. R & R LT AILERON INBD AND OTBD SERVO IAW MM 27-14-00-820-001-A. FREEPLAY CHECKED INBD & OTBD SERVOS IAW MM 27-14-00-220-001-A (CK GROUND) AND OPS CK AILERONS IAW MM 27-14-00-710-004.SDR USAA2013060700009Lens · brokenEXIT ROW LIGHT BROKE OFF AT 1C. REPLACED LENS AT 1C EMERGENCY LIGHT.SDR USAA2013060700008Light · inoperativeEMERGENCY EXIT SIGN AT AFT OF CABIN NOT ILLUMINATED. REPLACED EMERGENCY EXIT LIGHT AT AFT CABIN OVERHEAD.SDR UALA2013060603954Servo · out of adjustRT AILERON FAILED FREE PLAY CHECK WITH INBD SERVO ACTIVE R & R RT AILERON SERVO. ADJUSTED SERVO FREEPLAY, CHECKED GD SERVO & OPS CK SERVO IAW MM 27-14-51-000-001-A, 27-14-51-400-001-A, 27-14-00-220-0014, 27-14-00-820-001-A AND 27-14-00-710-001-A. OPS CK & FRSDR UALA2013060603952Battery · no testCABIN EMERGENCY LIGHT CHECK FAILED. REPLACED BATTERY, OPS CHECKED GOOD.SDR UALA2013060603950Power Supply · inoperativeACCOMPLISHED EMERGENCY LIGHT TEST VIA CIDS PANEL, HAD FAULT EPSU AFT LEFT. ACCOMPLISHED TEST VIA PWR SUPPLY AND FAULTED UNIT ASSY. REPLACED POWER SUPPLY AND BATTERY, SYS OP'S CK'S NORMAL.SDR UALA2013060503894Cover · missingLEFT MLG MISSING PLASTIC COVER WHERE L-G MEETS AC. REPLACED RUBBER CUP. OK TO CONTINUE.SDR UALA2013060703961Actuator · leakingLEFT MLG LOCK STAY ACTUATOR HAS A RUNNING LEAK. REPLACED ACTUATOR, OPS AND LEAK CHECKED OK.SDR UALA2013060503884Stringer · corrodedAFT CARGO BAY STRINGER 41R HAS CORROSION BETWEEN FR 58-63. CORRODED BEYOND SRM LIMITS, REMOVED STRINGER IAW SRM 51-42-11 P7, LOCATED AND DRILLED NEW STRINGER IAW SRM 51-44-11P1 & INSTALLED IAW SRM 51-42-11 P7. MAJOR REPAIR.SDR USAA2013061200039Floor Panel · delaminated2S CHECK - DELAMINATION ON FLOOR PANEL 231BF BETWEEN FR23 TO FR24, Y=0. REPLACED FLOOR PANEL 231BF IAW IRM 9701, REV. G.SDR USAA2013061200038Floor Panel · delaminated2S CHECK - DELAMINATION ON FLOOR PANEL 221DF BETWEEN FR16 TO FR21, Y=0. REPLACED FLOOR PANEL 221DF IAW IRM 9701, REV G.SDR UALA2013060503895Fluid · leakingCONSTANT DRIP ON FLUID COMING OUT OF APU DRAIN MAST. FLIGHT CREW REPORTING THAT FUEL WAS DRIPPING FROM DRAIN MAST WITH APU RUNNING. PLACARDED APU INOP. NO DAMAGE NOTED, NO LEAKS NOTED WITH APU OFF. ALSO HOC BEGAN AFTER FCU WAS REPLACED. REF: PTT SEQ 8742001.SDR UALA2013060503893Sensor · dirtyLGCIU 1 FAULT RETURNED. FOUND NLG EXTEND SENSORS COVERED WITH GRIME AND GREASE. CLEANED SENSORS REF AMM 32-31-73 P 601 AND CHECKED CLEARANCES. PERFORMED BITE TEST: NO DAMAGED SENSORS.SDR UALA2013060503892Sleeve · damagedNR 1 ENG LOOKS TO HAVE SOME SKIN PROTRUDING FROM THE REVERSER SLEEVE ABOUT 1 O'CLOCK POSITION.SDR USAA2013060500008Lens · missingEMERGENCY LIGHT LENS MISSING AT ROW 19LT. REPLACED LENS.SDR YENA20130604119Interface Unit · failedACFT DIVERTED DUE TO LGCIU FAULT ON ECAM. ON TAKEOFF 3 RED LIGHTS INDICATING GEAR UNLOCKED. ACCOMPLISHED TASK CARD 32-31-00 AND BITE CHECK OF LGCIU1&2. R & R NR 1 LGCIU IAW AMM TASK 32-31-71. ALSO REPLACED LANDING GEAR LEVER (6GA) AS PRECAUTIONARY IAW AMM SDR UALA2013060603949Seal · damagedNR 1 RT MOVABLE FAIRING - AFT INBD OF FAIRING MISSING 5" OF SEAL. REPAIRED.SDR UALA2013060403862Stringer · corrodedAFT CARGO BAY STRINGER 42L HAS CORROSION BETWEEN FR 63-64. AFTER CORROSION REMOVAL FOUND TO BE OUT OF SRM LIMITS. REPLACED STRINGER AT FACTORY SPLICES FROM FR 60-64 IAW SRM 51-72-11, PG 1-2. STRINGER REPLACED AT FACTORY SPLICES FROM FR 60 TO 64 IAW SRM 51-7SDR USAA2013060400004Light · inoperativeEMERGENCY LIGHT 22E OUT. REPLACED LIGHT ASSY AT ROW 22E IAW AMM 33-51-19-400-001-A.SDR UALA2013060303859Seal · deterioratedF/A REPORTS LOUD WHISTLING SOUND AT EXIT ROW 21A. FOUND BUTT SEAL BETWEEN PANEL 191BT AND 191DT DETERIORATED. APPLIED MT-53-004, DL1484 CREATED TO MONITOR. REPLACED SEAL AT JOINT OF 191BT AND 191DT OK.SDR USAA2013061200036Seat Track · corroded2S CHECK - CORROSION ON SEAT TRACK BETWEEN FR60 TO FR61, -Y765. REPLACED SEAT TRACK BETWEEN FR60 TO FR61, -Y765 IAW SRM 51-42-11.
Back to Airbus A320-232