SDR F3LA202110260081Ecs · contaminatedCHEMICAL ODOR DETECTED IN BOTH CABIN AND FLIGHT DECK. PERFORMED LEVEL 'C' DECONTAMINATION OF THE (ECS) ENVIRONMENTAL CONTROL SYSTEM IAW AMM 71-00-00-615-804-A, AIRCRAFT RUNS PERFORMED WITH NO ODOR PRESENT. REF PEMCO NR11773-00, AMM 71-71-49/36-22-00/NTM 51-90SDR F3LA202110220078Unknown · odorFUME EVENT ON DESCENT. -SEEMS ASSOCIATED WITH PACK 1. PERFORMED TSM 05-50-00-810-831-A, NO APU OIL LEAK FOUND, NO ENGINE OIL LEAK FOUND. OPERATED PACKS WITH ENG BLEED AIR & APU BLEED AIR UNABLE TO DUPLICATED FAULT ON GROUND A/C OK FOR SVC.SDR F3LA202110200076Unknown · odorELEC SMOKE SMELL EMER EXIT ROW RIGHT SIDE ON DESCENT BELOW 8000 FT. PERFORMED VISUAL IN AIRCRAFT CABIN WITH PACKS COLD FOR 10 MINUTES AND HOT FOR 10 MINUTES NO SMELL NOTED. PERFORMED #2 ENGINE IDLE NO SMELLS NOTED. NO CBS TRIPPED. NO ECAM FAULTS. NO FUMES NOTSDR F3LA202110190077Slide Raft · inoperativeLP183473 ITEM 2 DISCREPENCY --- EMER POWER SUPPLY UNIT 10WL INOP. CORRECTIVE ACTION LP189477 ITEM 1 -- R+R R1 DOOR SLIDE IAW AMM 25-62-44-00-802-A +25-62-44-400-802-A TW JC-2756 DUE DATE 6/14/2022SDR F3LA202110130075A/C Pack · odorFLIGHT ATTENDANTS AND PASSENGERS SMELLED ODOR DESCRIBED AS COMING FROM AFT CABIN VENTS. FLIGHT ATTENDANTS DESCRIBED ODOR AS 1) BURNING RUBBER OR 2) "MUSTY SOCKS" . ISOLATED / REMOVED ODOR IAW QRH ELIMINATION OF ODORS CHECKLIST - PACK 2 OFF ODOR DISSIPATED W/INSDR F3LA2021090200064Line · leakingHYD Y RSVR LO LVL IN FLIGHT. REPLACED ENG PYLON PRESS LINE IN FWD PYLON, P/N D2902083400000 LEAK CHECK GOOD AMM 29-13-49-400-842-ASDR F3LA2021081600060Line · leakingGREEN HYDRAULIC SYSTEM FAILURE AND MANUAL GEAR EXTENSION. DURING THE T/S FOUND HYD LINE #1 ENGINE PYLON CRACKED. SVCD GREEN HYD PER REF AMM 12-12-29-611-301-A. R/R ENG 1 PYLON HYD LINE PER AMM 29-11-49-04, LK & OPS CK OK. C/W AMM 32-00-00-860-003-A TO PUT LSDR F3LA2021081600059Seal · failedRT WING AIR LEAK. R/R #2 PACK OZONE CONVERTER SEAL AS REQUIRED. OPS CHECK & LEAK CHECK GOOD REF AMM 21-51-41-04.SDR F3LA2021082600062Fan · failedHEARD ODD PULSATING SOUND AND BEGAN SMELLING ACRID ELECTRICAL SMOKE SMELL. RAN SMOKE /FUME/AVIONICS SMOKE CHECKLIST AND SMELL AND SOUND DISSAPATED WHEN VENTILATION FANS WERE TURNED OFF. REMOVED AND REPLACED AVIONIC FAN IAW AMM 21-26-51-000-001-A / 400-001-A OSDR F3LA2021081000114Fan · fumesHEARD ODD PULSATING SOUND AND BEGAN SMELLING ACRID ELECTRICAL SMOKE SMELL. RAN SMOKE /FUME/AVIONICS SMOKE CHECKLIST AND SMELL AND SOUND DISSAPATED WHEN VENTILATION FANS WERE TURNED OFF.SDR F3LA2021071200053Fitting · leakingHYD. Y RSVR LO LVL. R&R HYD. YELLOW PRESSURE LINE FITTING AND LINE AT ENG #2 REF. AMM 29-13-49-400-812-A. PERFORMED MIN. IDLE LEAK CHECK IS OK. REF. NON ROUTINE #123083.SDR F3LA2021071200054Fitting · crackedLP156984 ITEM 1, DISCREPANCY: GREEN HYDRAULIC SYSTEM LO PRESSURE. AIR TURN BACK TO DENVER. CORRECTIVE ACTION: FOUND PRESSURE FITTING LEAKING IN #1 ENGINE PYLON. REPLACED FITTING AND HYD LINE, DUE TO BOTH NEEDING TO BE REPLACED AS A SET PER THE IPC (SDR F3LA2021061700044Slide · no testL1 ESCAPE SLIDE FAILED EPSU TEST. THIS WAS DURING OVERNIGHT MAINTENANCE. REPLACED L1 ESCAPE SLIDE L1 IAW AMM 25-62-44-400-007-A. T/W F9TAB1763C, CAL DUE 04-2022. TEST OK.SDR F3LA2021052700038Slide · detachedDISCREPANCY, LP156914: L1 SLIDE PACK BECAME DETACHED FROM DOOR AT DEPLANE ( AS DOOR OPENED AT ARRIVAL GATE) CORRECTIVE ACTION: REPLACED L1 DOOR (7500MM) ESCAPE SLIDE-RAFT PACK ASSY REF AMM 25-62-44-000-012-A, AMM 25-62-44-400-007-A. TW # F9TAB2940C DUE 08-2021SDR F3LA2021050500035Battery · dischargedDISCREPANCY: EPSU TEST FAILED. CORRECTIVE ACTION: REMOVED AND REPLACED BATTERY (11WL). OPS OK. REF. AMM 33-51-38-400-002-A.SDR F3LA2021041200029Ecs · odorDISCREPENCY: FORWARD FLIGHT ATTENDENT REPORTED SMELLING BURNING RUBBER FOR 3 TO 4 MIN ON FINAL APPROACH. CORRECTIVE ACTION: PERFORMED DECONTAMINATION OF THE ECS PER AMM 21-00-00-615-802-A. NO ODOR WAS NOTED DURING THIS PROCEDURE. A/C OK FOR SERVICE AMM 21-00-0SDR F3LA2021032900026Warning Message · false activationLP164059 ITEM 1 -- DURING TAKEOFF ROLL AT ABOUT 60KTS WE GOT THE DOOR L AFT EMER EXIT ECAM ABORTED TAKEOFF AND RETURNED TO THE GATE --- CORRECTIVE ACTION -- PERFORMED OPS CHECK OF THE LEFT AFT PASSENGER COMPARTMENT EMERGENCY EXIT IAW TSM 52-21-00-810-802-A OPSSDR F3LA2021030900020Battery · no testLP1217092 ITEM 2 -- DURING OPERATIONAL TEST OF EMER LIGHTING FOUND FWD L (12WL) EMER BATTERY FAILED --- CORRECTIVE ACTION -- REMOVED AND REPLACED FWD L ( 12WL) EMER BATTERY OPS CHECKS GOOD. REF AMM 33-51-38-002A/AMM 33-51-38-400-002A.SDR F3LA2021030900019Battery · no testLP1217092 ITEM 1 -- DURING OPERATIONAL TEST OF EMER LIGHTING FOUND FWD L (10WL) EMER BATTERY FAILED --- CORRECTIVE ACTION -- REMOVED AND REPLACED FWD L ( 10WL) EMER BATTERY OPS CHECKS GOOD. REF AMM 33-51-38-002A/AMM 33-51-38-400-002A.SDR F3LA2021030100016Battery · dischargedLP 145547 ITEMS 2 & 3 UPON AIRCRAFT INSPECTION THE EMERGENCY POWER SUPPLY UNITS 11WL & 12WL (EPSU BATTERIES) FAILED TO TEST
CORRECTIVE ACTION: REMOVED AND REPLACED EPSU BATTERIES 11WL & 12WL -TEST OK REF AMM 33-51-38-04 CONF 00SDR F3LA2021022200010Slide · no testLP1229953 ITEM 1 DISCREPANCY: L1 DOOR SLIDE FAILED EPSU TEST (PER NIGHT SHIFT). CORRECTIVE ACTION: REMOVED AND REPLACED SLIDE RAFT FWD FIN 7500MM. REF AMM 25-62-44-400-012A.SDR F3LA2021021700009Speed Brake · unwanted deployDURING DESCENT THROUGH 14000 @ 320 K SPEED BRAKES EXTENDED AUTOPILOT ENGAGED AIRCRAFT MADE AN UNCOMMANDED ROLL TO THE RIGHT. AUTOPILOT WAS DISENGAGED. AIRCRAFT HANDLED NORMAL AT THAT TIME. SPEED BRAKES APPEARED TO EXTEND SYMMETRICALLY AND RETRACTED EVENTUALSDR F3LA2021020100007None · noneRAD NAV PAGE BLANK AND ACFT DIDN'T CAPTURE THE ILS SIGNAL. FOUND RMP 1&2 STYBY NAV SWITCH SELECTED. PLACED RMP'S TO NORMAL CONFIG. PERFORMED AFS TEST, TEST OK NO DEFECTS FOUND. ACFT OK FOR SERVICE. AMM 22-96-00-710-001ASDR F3LA2021012500004Arming Lever · looseDOOR L1 ARMED LEVER IS LOOSE WHEN STOWED IN THE ARMED POSITION. PLACED ON MEL 25-61-02A CONTROL 1167688. DUE DATE 01/31/2021 PER MCC RAH 428023 A/C OK FOR SERVICE. LP 147501 ITEM 2 CORRECTIVE ACTION: REF MEL 25-61-02A CNTRL 1167688. REMOVED L1DOOR SLIDE RESDR F3LA2021011400003Battery · dischargedUPON AIRCRAFT INSPECTION THE EMERGENCY POWER SUPPLY UNIT (EPSU BATTERY) FAILED TO TEST. CORRECTIVE ACTION: REMOVED AND REPLACED EPSU BATTERY. OPERATIONS CHECK GOOD, REF AMM 33-51-00-710-050-B.SDR F3LA2021011100002Line · leakingHYD G RSVR LO LEVEL HYD G ENGINE 1 PUMP LO PR HYD G SYS LO PR. FOUND HYD LINE PART NR D2902083800000 LEAKING IN FORWARD PYLON NR 1 ENGINE. CORRECTIVE ACTION: REPLACED HYD LINE, PER AMM 29-00-00-910-0014-A. LEAK CHECK C/W NO LEAKS NOTED. AIRCRAFT OK FOR SERSDR F3LA2020123100057Power Supply · failedDISCREPANCY: AFT EMERGENCY EXIT SIGNS NOT ILLUMINATED. CORRECTIVE ACTION: R & R EPSU, IAW AMM 33-51-38-000/400-001-A. OPERATIONS CHECK GOOD, AC OK TO CONTINUE.SDR F3LA2020123000056Battery Pack · no testDEFECT: EPSU TEST FAILURE. CORRECTIVE ACTION: REMOVED AND REPLACED EPSU BATTERY FOR UNIT (10WL) AND UNIT (13WL). EPSU TEST STILL FAILS. SYSTEM REQUIRES FURTHER TROUBLESHOOTING, REFERENCE AMM 33-51-38. REMOVED AND REPLACED R2 DOOR SLIDE, OPERATIONS CHECK GOSDR F3LA2020122100053Battery · no testDURING EPSU BATTERY CAPACITY TEST, EPSUS FIN 10WL, 11WL 12WL AND 13WL FAILED TEST. CORRECTIVE ACTION: REMOVED AND REPLACED EPSU BATTERIES FIN 10WL, 11WL, 12WL AND 13WL, TEST OK AT THIS TIME, REF AMM 33-51-00-920-050-A.SDR F3LA2020121500052Oil System · overservicedEXPERIENCED FUME EVENT DURING CRUISE. BURNING RUBBER SMELL IN FLIGHT DECK OCCURED 11 MINUTES INTO FLIGHT AND REMAINED UNTIL LANDING. CORRECTIVE ACTION: FOUND ENGINE 1 OIL OVERSERVICED TO 19 QT DRAINED DOWN OIL TO WITHIN SERVICEABLE LIMITS. PERFORMED TSM 05-SDR F3LA2020121400051Inlet · contaminatedDISCREPANCY: BTB 2107-FA ADVISED OF A STRONG ODOR IN THE CABIN THAT WAS BURNING THIER EYES. A/C WAS ON THE GROUND WITH ENGINE BLEEDS ON AND BOTH PACKS ON. CORRECTIVE ACTION: PERFORMED INSPECTION OF APU, IAW AMM 49-16-00-210-802-A. CLEANED DE-ICE FLUID FROM SDR F3LA2020111700045Connector · looseDISCREPANCY: FWD FACING EXIT LIGHT OVER EXIT ROW 13 INOPERABLE. CORRECTIVE ACTION: GROUND CONNECTOR TO EXIT LIGHT ASSEMBLY LOOSE. SECURED GROUND CONNECTOR, OPERATIONS CHECK OF EMERGENCY LIGHT SYSTEM GOOD, REF AMM 33-51-00-710-805-A.SDR F3LA2020110500044Unknown · odorSTRONG, FOUL, OILY, MUSTY ODOR ON TAXI. PERFORMED IDENTIFICATION OF CAUSE FOR CABIN ODOR, SMOKE OR FUME, IAW TSM 05-50-00-810-831-A. FOUND NO FAULTS, NO CABIN ODOR NOTED AT THIS TIME, A/C OK TO CONTINUE.SDR F3LA2020092500039Regulator · faultedCRUISE AT FL270 GOT ADVISORY FOR EXCESSIVE CABIN ALTITUDE. CABIN WAS AT 9200 FT CABIN PRESS PAGE POPPED UP AND SHOWED THE PACK 1 TRIANGLE AMBER. CABIN WAS SLOWLY RISING (REMEMBER PACK 2 TRIANGLE WAS AMBER AS WELL AS PACK 2 WAS MEL'D) A FEW MINUTES LATER WE GSDR F3LA2020092500040Actuator · failedDURING MX FOUND THS ONLY MOVING 1/2 DEGREE UP AND DOWN. MX IS T/S, NO ECAM FAULTS. AIRBUS IS ENGAGED. R & R THS ACTUATOR, IAW AMM 27-44-51-400-001-A. OPS CHECK GOOD.SDR F3LA2020091400036Slide · no testDISCREPANCY: ITEM 1, L1 DOOR SLIDE FAILED EPSU TEST. CORRECTIVE ACTION: R AND R L1 DOOR SLIDE IN ACCORDANCE WITH AMM 25-62-44-000-012-A/AMM 25-62-44-400-007-A. OPS CHECKED GOOD, NO DEFECT AT THIS TIME. AIRCRAFT IS OK TO CONTINUE.SDR F3LA2020091400037Slide · no testDISCREPANCY: L1 DOOR SLIDE FAILED EPSU TEST. DURING OVERNIGHT MAINTENANCE. CORRECTIVE ACTION: REPLACED L1 DOOR SLIDE, REF AMM 25-62-44-000-012-A AND 25-62-44-400-007-A. OPS CHECKS GOOD AT THIS TIME.SDR F3LA2020090800035Diaphragm · puncturedFOUND DOOR DAMPER DIAPHRAGM PUNCTURED. REPLACED DIAPHRAGM AND SERVICED DAMPER, REF AMM 52-10-00-614-001 AND 52-10-00-616-001-A. 09/06/2020-L1 DOOR ASSIST BOTTLE WILL NOT HOLD A PRESSURE CHARGE.SDR F3LA2020090800034Relay · failed09/06/2020-CORRECTIVE ACTION: REMOVED AND REPLACED RELAY FIN#3PH, IAW TSM 24-24-00-810-806-A. OPS CHECK GOOD, AIRCRAFT OF FOR RETURN TO SERVICE. 09/05/2020-FAILS EMER GEN TEST, AS PER HEAVY SERVICE CHECK TASK CARD 281100-01 STEP 8 AMM REF 24-24-00-710-001-A,SDR F3LA202008030033Pitot Line · obstructedUNRELIABLE AIRSPEED INDICATION ON T/O. CAPT @ 70KTS, FO @ 105 ABORTED TAKE-OFF - MAX BRAKE TEMP WAS APPROX 720°. FLUSHED PITOT STATIC SYSTEM, PERFORMED FUNCTIONAL TEST OF ALT AIRSPEED DATA SYSTEM, FUNCTIONAL TEST PASSED IAW AMM 34-13-00-720-009-B.SDR F3LA202007300032Actuator · leakingTHS ACTUATOR LEAKING AND SIGHT GLASS READS MIN. REMOVED AND REPLACED ACTUATOR PER A320 AMM 27-44-51-000-001-A & 27-44-51-400-001-A. OPS & LEAK CHECK GOOD.SDR F3LA202006240029Fitting · buckledHYD GREEN RSVR LO LEVEL FOLLOWED BY GREEN PUMP LO PRESSURE, GREEN SYSTEM LO PRESS, PERFORMED QRH PROCEDURES. DECLARED EMERGENCY, NO FURTHER DEFECTS NOTED. UNDER LANDING WEIGHT. - ALSO GRAVITY GEAR EXTENSION PERFORMED W/NO DEFECTS NOTED, ALL 3 GREEN IND. MAINTASDR F3LA202006050028Connector · looseEPSU AT FIN 11WL FAULTS DURING TEST ON HEAVY CHECK. REMOVED LT OVERWING SLIDE, FOUND LOOSE CONNECTOR, TIGHTENED CONNECTOR. REINSTALLED SLIDE ON ITEM 2 OF THIS LOG PAGE AND PERFORMED OPS TEST PER AMM 33-51-15-400-001-A, NO FAULTS FOUND.SDR F3LA202005290027Power Supply · failedDISCREPANCY: LP1267381 ITEM 1, EXIT LIGHT AT THE EXIT ROW ON THE LEFT SIDE INOPERATIVE. CORRECTIVE ACTION: REMOVED AND REPLACED EMERGENCY POWER SUPPLY UNIT "11WL", OPS CHECK GOOD. REF AMM 33-51-38-04.SDR F3LA202003260024Epsu · failedDISCREPANCY: LP1241800 ITEM 1: DURING OVERNIGHT MAINTENANCE, EPSU SYS TEST FAILED DUE TO EPSU 11WL FAULT. CORRECTIVE ACTION: REMOVED AND REPLACED EPSU 11WL, DUE TO FAULTING PERFORMED EPSU SYS TEST, TEST PASSED. REF AMM 33-51-38-000-001-A AND AMM 33-51-38-400SDR F3LA2020032530020Oil System · overservicedDISCREPANCY : ON DESCENT AT ABOUT 10000 FT SMELLED ODOR IN BOTH COCKPIT & CABIN LASTED ABOUT 5 MINUTES. CORRECTIVE ACTION : PERFORMED T/S TASK FOR CAUSE FOR CABIN ODOR. AFTER ENGINE RUN DETERMINED ENGINE 2 BLEED SYSTEM IS CAUSE AS PER TSM 05-50-00-810-331-A SESDR F3LA202003030014Unknown · malfunctioned03/03/2020 - PRELIMINARY: POSSIBLE INTERNAL SPRING WEAR, AC FERRIED IN FROM RDU // MX INSPECTING DOOR HANDLE AND MECHANISM. SUPPLEMENT: 03/04/2020 - LP 1239995 ITEM 1 -- FRONT RIGHT (1R) DOOR WILL NOT LATCH FROM OUTSIDE. -- OPERATIONAL CHECK OF R1 DOOR SHOWS NSDR F3LA2020030490015Seat · looseLP 1238842 ITEM 2 -- ROW 2 DEF CAME LOOSE ON TAKEOFF ROLL AND HIT ROW 3 DEF. CORRECTIVE ACTION -- INSTALL REQUIRED HARDWARE + REINSATLLED SEAT ROW 2 DEF INTO SEAT TRACK . OK FOR SERVICE . TW # 9946 CAL DUE 3-5-20 CMM 25-20-35SDR F3LA2020022530012Switch · failedPASSENGER O2 SYSTEM ACTUATED DURING FLIGHT FOR UNKNOWN REASON. 02/27/2020 SUPPLEMENT - CORRECTIVE ACTION: REFERENCE PEMCO NR 2788N3 AND LP1254353 ITEM 1, CABIN ALTITUDE PRESSURIZATION SWITCH FOUND FAULTY. REMOVED AND REPLACED CABIN ALTITUDE PRESSURIZATION SWITSDR F3LA2020021850010Tip Cap · damagedSUPPLEMENT: 03/05/2020: R&R LEFT WING TIP ASSEMBLY PN D5735690300001, SN 11543-REF AMM 57-31-23-PB401. REMOVED AND REPLACED LH WING SLAT #5 PN D5746095000600, SN SA8202, IAW AMM27-84-67-PB401, REF NR 121228, WO401588 FOR CORRECTIVE ACTION. SIGNIFICANT DAMAGE T