Airbus A321-211
Service difficulty reports · 12,330
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A321211' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A321211' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR USAA2014050700003Access Panel · corroded2S CHECK LT WING FUEL ACCESS PANEL 550BB CORRODED AT FASTENER HOLES. R & R ACCESS PANEL IAW SRM 57-27-11.SDR USAA2014050100008Proximity Switch · faultyTHE LOWER ECAM SHOWING 2R SLIDE NOT ARMED, SLIDE ARMED, FLASHING GREEN ON CIDS PANEL. REPLACED PROX SWITCH 5WN2 IAW AMM 52-71-13, OPERATIONS CHECKED GOOD.SDR USAA2014042900005Light · unsecureCREW REPORTED THE EXIT LIGHT AT FWD ENTRY DOOR LOWER PANEL NOT SECURE. SECURED PANEL AS REQUIRED.SDR USAA2014051300014Seat Track · corrodedS2 CHECK LEVEL 2 EXFOLIATION CORROSION ON SEAT TRACK AT FRAME 24, Z -500, -Y1292. REPAIRED SEAT TRACK AT FRAME 24, Z -500, -Y1292 IAW SRM 53-11-01-05.SDR USAA2014051200034Floorbeam · corrodedS2 CHECK, LEVEL 2 INTERGRANULAR CORROSION ON UPPER SURFACE OF FLOORBEAM AT FRAME 66, Y1292. REPLACED FLOORBEAM AT FRAME 66, Y1292 IAW SRM 51-42-11.SDR USAA2014051200019Floorbeam · corrodedS2 CHECK, LEVEL 2 INTERGRANULAR CORROSION ON AFT SECTION OF FLOORBEAM AT FRAME 68, Z-500, -Y1160. REPLACED FLOORBEAM AT FRAME 68, Z-500, -Y1160 IAW SRM 51-72-11 & IPC 53-41-04-21.SDR USAA2014051200018Floorbeam · corrodedS2 CHECK, LEVEL 2 INTERGRANULAR CORROSION UPPER SURFACE OF FLOORBEAM BETWEEN FRAME 66 TO FRAME 67, Z-500, -Y1292. REPLACED FLOORBEAM BETWEEN FRAME 66 TO FRAME 67, Z-500, -Y1292 IAW SRM 51-42-11.SDR USAA2014050900001Door Sill · corrodedS2 CHECK, LEVEL 2 SURFACE CORROSION ON R4 DOOR SILL AT FRAME 68, Z-500, -Y1589. REPAIRED R4 DOOR SILL AT FRAME 68, Z-500, -Y1589 IAW SRM 53-41-14-201, REPAIR PRINCIPLE 5 & EA 207457.SDR USAA2014050800004Door Sill · corrodedS2 CHECK LEVEL 2 EXFOLIATION CORROSION ON R1 DOOR SILL BETWEEN FRAME 16 TO FRAME 20, Z-500, -Y1584. REPLACED R1 DOOR SILL BETWEEN FRAME 16 TO FRAME 20, Z-500, -Y1584 IAW SRM 51-72-11 & 51-75-12.SDR USAA2014050700002Floorbeam · corroded2S CHECK CABIN FLOORBEAM CORRODED AT FRAME 16, W -500 & Y -81. R & R FLOORBEAM IAW SRM 51-72-11 & DWG D53112828.SDR USAA2014050600021Door Sill · corrodedS2 CHECK - LEVEL 2 INTERGRANULAR CORROSION ON L4 DOOR WAY CTR SHAPE SILL BETWEEN FRAME 66 TO FRAME 68 & BETWEEN Z-500, Y1292. REPLACED L4 DOOR WAY CTR SHAPE SILL BETWEEN FRAME 66 TO FRAME 68 & BETWEEN Z-500, Y1292 IAW SRM 51-72-11 & DWG D53480048.SDR USAA2014050600019Seat Track · corrodedS2 CHECK LEVEL 2 EXFOLIATION CORROSION ON SEAT TRACK BETWEEN FRAME 21 TO FRAME 23, Z-500, -Y 765. REPLACED SEAT TRACK BETWEEN FRAME 21 TO FRAME 23, Z-500, -Y765 IAW SRM 51-27-11.SDR USAA2014042800019Handle · lack of lubeTHE L4 DOOR EXTERIOR HANDLE WILL NOT LOCK IN UP POSITION. CLEANED & LUBRICATED L4 DOOR HANDLE, EXTERIOR. OPERATED SEVERAL TIMES, HANDLE LOCKED INTO POSITION EACH TIME. OK FOR SERVICE AT THIS TIME IAW MINOR MAINTENANCE IAW MPPM 54-01-10.SDR USAA2014042800022Cover · brokenLOW LEVEL LIGHT AT 1AC COVER BROKEN. REPLACED AS REQUIRED, CHECKED OK.SDR USAA2014042400017Lens · missingTHE RT REAR EMERGENCY LIGHT LENS COVER MISSING ON PANEL NEXT TO SERVICE DOOR. INSTALLED NEW LENS COVER, OPERATIONS CHECKED GOOD.SDR USAA2014042100017Spring · brokenTHE L1 DOOR GIRT BAR FITTING SPRING BROKEN. REPLACED L1 DOOR GIRT BAR FITTING SPRING IAW AMM 52-13-31-400-003-A.SDR USAA2014041700003Lens · missingROW 8 EMERGENCY LIGHT LENS MISSING. REPLACED ROW 8 EMERGENCY LIGHT LENS AS REQUIRED.SDR USAA2014041700002Filter · dirtyALL LAVATORY SMOKE DETECTOR FILTERS DIRTY & CLOGGED, POST WEEKLY CHECK. REPLACED ALL LAVATORY SMOKE DETECTOR FILTERS, AS NECESSARY.SDR USAA2014041600008Cover · brokenTHE EXIT LIGHT COVER BROKEN AT SEAT 8D. REPLACED LIGHT COVER, OK FOR SERVICE.SDR USAA2014041600005Wire · damagedTHE EMERGENCY LIGHT INOPERATIVE AT BULKHEAD 2L. REPAIRED WIRING IAW ESPM CHAPTER 20-43-11, OPERATIONS CHECKED OK.SDR USAA2014041500003Unknown · malfunctionedTHE EMERGENCY EXIT LIGHT 2L & EMERGENCY EXIT LIGHT OVERHEAD FWD LIGHT STAYS ON, ROW 10. ACCOMPLISHED TEST OF EPSU, TESTED OK IAW 33-51-00-710-001, OPERATIONS CHECKED NORMAL.SDR USAA2014041400025Bottle · low pressureL3 DOOR PRESS LOW ON CIDS. FOUND L3 DOOR ASSIST BOTTLE LOW, SERVICED TO REQUIRED INDICATION IAW AMM 52-22-00.SDR USAA2014041400005Floor Panel · delaminatedS2 CHECK DELAMINATION ON FLOOR PANEL 251PF BETWEEN FRAME 54 TO FRAME 58, Z-500, Y1292. REPLACED FLOOR PANEL 251PF IAW IRM 9701, REVISION G.SDR USAA2014041400004Floor Panel · delaminatedS2 CHECK DELAMINATION ON FLOOR PANEL 252KF BETWEEN FRAME 52 TO FRAME 57, Z-500, -Y1292. REPLACED FLOOR PANEL 252KF IAW IRM 9701, REVISION G.SDR USAA2014041400002Slide · damagedS2 CHECK THE LT REAR PAX DOOR SLIDE BINDING CORD IS FRAYED. REPLACED SLIDE ASSEMBLY AT LT REAR PAX DOOR IAW JOB CARD 26C83252020.SDR USAA2014041000006Floor Panel · delaminated2S CHECK FLOOR PANEL 231HG IS DELAMINATED BETWEEN FRAME 35.5 & FRAME 35.8. FABRICATED & INSTALLED NEW FLOOR PANEL IAW IRM 9701 REVISION G.SDR USAA2014041000005Floor Panel · damaged2S CHECK FLOOR PANEL 251JF SURFACE DAMAGED FROM FRAME 51 TO FRAME 54 AT Y 1497. FABRICATED & INSTALLED NEW FLOOR PANEL IAW IRM 9701 REVISION G.SDR USAA2014040900005Lens · missingR4 DOOR EMERGENCY EXIT LIGHT LENS MISSING AT LOWER AFT SIDE OF DOOR FRAME. INSTALLED NEW LIGHT LENS ON R4 DOOR LOWER AFT SIDE AS NOTED.SDR USAA2014040900006Lens · missingRED EMERGENCY EXIT LIGHT LENS AT SEAT 9A IS MISSING. INSTALLED RED EMERGENCY EXIT LIGHT LENS AT SEAT 9A.SDR USAA2014040800010Sensor · faultyEN ROUTE FROM PHL TO MCO, CREW SENT AN ACARS MSG, ANTI-ICE LT WINDSHIELD. DUE TO HISTORY ON ANTI-ICE LT WINDSHIELD & FORECASTED ICING CONDITIONS AHEAD, FLIGHT DIVERTED TO CLT. FLIGHT LANDED WITHOUT INCIDENT. IAW TSM 30-42-00-810-801A, SWAPPED WIRES TO SPARESDR USAA2014040800007Computer · faultyEN ROUTE FROM CLT TO JFK, CREW RECEIVED AN ECAM ANTI-ICE LT WINDSHIELD INOPERATIVE, PRIOR TO ENTERING ICING CONDITIONS. FLIGHT DIVERTED TO PHL FOR MAINTENANCE, FLIGHT LANDED WITHOUT INCIDENT. TROUBLE SHOT IAW TSM 30-42-00-810-801-A, ALL SYS CHECKED GOOD. R &SDR USAA2014040900004Floor Panel · delaminatedS2 CHECK DELAMINATION ON FLOOR PANEL 251HF BETWEEN FRAME 51 TO FRAME 54, Z-500, Y756, REPLACED IAW IRM 9701, REV G.SDR USAA2014040700015Terminal · missingMAINTENANCE FOUND EMERGENCY LIGHT AT 37WL 3L DOOR INOPERATIVE. FOUND WIRE MISSING TERMINAL TO LIGHT HOUSING. REPLACED EMERGENCY LIGHT AT 37WL 3L DOOR TERMINAL END & HOUSING IAW ESPM 20-48-14 & WDM 33-51-02-W-030019-AB. OPERATIONS CHECKED GOOD, ACFT OK FOR SSDR USAA2014040700014Lens · missingCREW REPORTED THE EMERGENCY LIGHT COVER MISSING NEAR SEAT 25C. REPLACED LIGHT LENS NEAR SEAT 25C.SDR USAA2014040900003Floor Support · corrodedS2 CHECK CORROSION ON FLOOR SUPPORT BEAM BETWEEN FRAME 42 TO FRAME 47.5, Z-500, -Y1584, REPLACED IAW SRM 51-72-11 & DWG D53459000.SDR USAA2014040700013Spring · lack of lubeCREW REPORTED THE FWD ENTRY DOOR SLIDE PACK RETAINER SPRING BROKEN. LUBED & OPERATIONS CHECKED SPRINGS, CHECKED GOOD.SDR USAA2014040700007Sensor · faultyCABIN TEMPS ON DEPARTURE & CLIMB OUT WERE EXCESSIVELY HIGH & UNCONTROLLABLE. RETURNED TO CLT FOR OVERWEIGHT LANDING, LANDING WEIGHT 176,200. TOUCHDOWN RATE OF DESCENT 200 - 300 FT, NORMAL BRAKING, BRAKE TEMPS 360. FOUND NR 2 PACK INLET PRESS SENSOR 36HH FAULSDR USAA2014040800002Shear Plate · corrodedSY6 CHECK LEVEL 2 EXFOLIATION CORROSION ON LATERAL SHEAR PLATE BETWEEN FRAME 69 TO FRAME 70, -Y1162.5. REPLACED LATERAL SHEAR PLATE BETWEEN FRAME 69 TO FRAME 70, -Y1162.5 IAW SRM 51-72-11 & 53-41-17.SDR USAA2014040800001Sill · corrodedSY6 CHECK LEVEL 2 GALVANIC CORROSION ON LT AFT SILL PLATE AT FRAME 68, Z-500, Y1162.5. REPAIRED LT AFT SILL PLATE AT FRAME 68, Z-500, Y1162.5 IAW SRM 53-41-201, FIG 201.SDR USAA2014040200010Battery · dischargedTHE EMERGENCY FLASHLIGHT AT L3 DOOR NOT BLINKING. REPLACED FLASHLIGHT BATTERY, OPS CHECKED GOOD.SDR USAA2014040200007Cylinder · low pressureTHE L2 SERVICE DOOR EMERGENCY OPENING CYLINDER HAS LOW PRESSURE. SERVICED L2 DOOR EMERGENCY OPERATING CYLINDER IAW AMM 52-22-00-614-002-A. LEAK CHECKED GOOD, OK FOR SERVICE.SDR USAA2014040200006Lens · missingTHE FLOOR LEVEL EMERGENCY EXIT LENS MISSING AT ROW 10 ABC. INSTALLED LENS IAW AMM 33-51-18, PB401.SDR USAA2014040200005Light · inoperativeTHE FLOOR LEVEL WALL MOUNTED EMERGENCY EXIT LIGHT INOPERATIVE AT L1 DOOR. R & R LIGHT ASSEMBLY IAW AMM 33-51-13, PB401.SDR USAA2014040300001Fitting · corrodedS2 CHECK, CORROSION ON AFT RT CORNER SHAPE FITTING AT FRAME 68, STRINGER 31L & Z-500. REPLACED AFT RT CORNER SHAPE FITTING AT FRAME 68, STRINGER 31L & Z-500 IAW SRM 51-42-11 & 51-72-11.SDR USAA2014040100009Lens · missingREPORTED SEAT 34L EMERGENCY LIGHT LENS MISSING. INSTALLED NEW EMERGENCY LIGHT LENS AT SEAT 34L IAW AMM 33-51-18-400-001-A, STEP 4 B D.SDR USAA2014040100008Lens · dislodgedCREW REPORTED THE PLASTIC COVER FOR FIRST CLASS LOW LEVEL LIGHTING FELL OFF. REPLACED MISSING LIGHT LENS 3L AS REQUIRED, OPERATIONS OK.SDR USAA2014040100007Filter · cloggedCREW REPORTED A MX CLASS 2 MESSAGE OF SMOKE. FOUND ALL LAVATORY AIR EXTRACTION FILTERS CLOGGED. R 7 R ALL LAVATORY EXTRACTION FILTERS IAW AMM 21-23-00. RESET CID'S & SDF CB`S IAW AMM 24-00-00-810-818A. PERFORMED TEST OF LAVATORY SMOKE DETECTION SYS IAW AMMSDR USAA2014040100006Switch · faultyCREW REPORTED AN ECAM WARNING, HYD G RSVR LOW LEVEL. DECLARED AN EMERGENCY & LANDED WITHOUT INCIDENT AT CLT. FLIGHT TAXIED TO THE GATE UNDER ITS OWN POWER. R & R GREEN RESERVOIR LOW LEVEL SWITCH IAW AMM 29-11-41-400-003-A. OPERATIONS CHECK & LEAK CHECKED NSDR USAA2014033100009Sill · corrodedS2 CHECK, LEVEL 2 GALVANIC CORROSION ON RT SILL PLATE AT FRAME 66, Z-500 & -Y 1582. REPLACED RT SILL PLATE AT FRAME 66, Z-500 & -Y 1582 IAW SRM 51-72-11.SDR USAA2014033100010Cover · missingAIRCRAFT ROW 10 LT COVER OVER EMERGENCY FLOOR LIGHT MISSING. REPLACED EMERGENCY FLOOR LIGHT COVER 10 LT.
Back to Airbus A321-211