Airbus A321-211
Service difficulty reports · 12,330
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A321211' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A321211' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR USAA2013090600007Seat Track · corroded2S CHECK, CORROSION ON SEAT TRACK BETWEEN FRAMES 20 TO 21, -Y189. REPLACED SEAT TRACK IAW SRM 51-72-11 & DWG D53111406.SDR USAA2013090500022Web · corroded2S CHECK, CORROSION ON WEB AT FRAME 20, Y1732. REPLACED WEB IAW SRM 51-72-11 AND DWG D53114392.SDR USAA2013090500021Web · corroded2S CHECK, CORROSION ON WEB BETWEEN FRAMES 20 TO 24, S23R, -Y1732. REPLACED WEB IAW SRM 51-72-11.SDR USAA2013091100025Floor Panel · delaminated2S CHECK, DELAMINATION ON FLOOR PANEL 151GF BETWEEN FRAMES 52 TO 56 & BETWEEN Y765 TO -Y765. REPLACED FLOOR PANEL IAW SRM 53-02-00 & IRM 9701, REV G.SDR USAA2013091100022Skin · contaminated2S CHECK, TRAPPED WATER INDICATION ON RT ELEVATOR UPPER SKIN SURFACE APPROX 70" INBD FROM RIB 10" & 4" FROM T/E. REPAIRED RT ELEVATOR UPPER SKIN SURFACE IAW SRM 55-21-11.SDR USAA2013091100021Elevator · saturated2S CHECK, TRAPPED WATER INDICATION ON RT ELEVATOR UPPER SKIN SURFACE APPROX 54" INBD FROM RIB 10" & 4" FROM T/E. REPAIRED RT ELEVATOR UPPER SKIN SURFACE IAW SRM 55-21-11, PAR 5E (2).SDR USAA2013091100020Skin · saturated2S CHECK, TRAPPED WATER INDICATION ON RT ELEVATOR UPPER SKIN SURFACE APPROX 7" INBD FROM RIB 10" & 4" FROM T/E. REPAIRED RT ELEVATOR UPPER SKIN SURFACE IAW SRM 55-21-11, PAR 5E(2).SDR USAA2013091100019Skin · saturated2S CHECK -TRAPPED WATER INDICATION ON RT ELEVATOR UPPER SKIN SURFACE APPROX 55" OTBD FROM RIB 5" & 4" FROM T/E. REPAIRED RT ELEVATOR UPPER SKIN SURFACE IAW SRM 55-21-11, PAR 5E(2).SDR USAA2013091100018Skin · saturated2S CHECK - TRAPPED WATER INDICATION ON RT ELEVATOR UPPER SKIN SURFACE APPROX 40" OTBD FROM RIB 5" & 4" FROM T/E. REPAIRED RT ELEVATOR UPPER SKIN SURFACE IAW SRM 55-21-11, PAR 5E.SDR USAA2013091100017Skin · contaminated2S CHECK - TRAPPED WATER INDICATION ON RT ELEVATOR UPPER SKIN SURFACE APPROX 26" OTBD FROM RIB 5" & 4" FROM T/E. REPAIRED RT ELEVATOR UPPER SKIN SURFACE IAW SRM 55-21-11, PAR 5E.SDR USAA2013091100016Skin · contaminated2S CHECK -TRAPPED WATER INDICATION ON RT ELEVATOR UPPER SKIN SURFACE APPROX 12" OTBD FROM RIB 5 & 4" FROM T/E. REPAIRED RT ELEVATOR UPPER SKIN SURFACE IAW SRM 55-21-11, PAR 5E (2).SDR USAA2013091100015Skin · contaminated2S CHECK -TRAPPED WATER INDICATION ON RT ELEVATOR UPPER SKIN SURFACE APPROX 1.0" OTBD FROM RIB 4 & 3" FROM T/E. REPAIRED RT ELEVATOR UPPER SKIN SURFACE IAW SRM 55-21-11, PAR 5E (2).SDR USAA2013082800020Floor Support · corroded2S CHECK- CORROSION ON FLOOR SUPPORT BETWEEN FRAMES 68 TO 69, Y254. REPLACED FLOOR SUPPORT IAW SRM 53-00-14, FIG 102 & 51-42-11.SDR USAA2013082700034Floor Panel · delaminated2S CHECK - DELAMINATION ON FLOOR PANEL 261PF BETWEEN FRAMES 68 TO 70 & BETWEEN Y1732 TO -Y1732. REPLACED FLOOR PANEL IAW SRM 53-02-00, FIG 209.SDR USAA2013082700033Floor Panel · delaminated2S CHECK - DELAMINATION ON FLOOR PANEL 262BG BETWEEN FRAMES 66 TO 68 & BETWEEN -Y765 TO -Y1732. REPLACED FLOOR PANEL IAW SRM 53-02-00, FIG 209.SDR USAA2013082700032Floor Panel · delaminated2S CHECK - DELAMINATION ON FLOOR PANEL 262EF BETWEEN FRAMES 66 TO 68 & BETWEEN -Y1292 TO -Y765. REPLACED FLOOR PANEL IAW SRM 53-02-00, FIG 209.SDR USAA2013082700031Floor Panel · delaminated2S CHECK - DELAMINATION ON FLOOR PANEL NR 261EF BETWEEN FRAMES 66 TO 68 & BETWEEN Y765 TO Y1292. REPLACED FLOOR PANEL IAW SRM 53-02-00, FIG 209.SDR USAA2013082700030Floor Panel · delaminated2S CHECK - DELAMINATION ON FLOOR PANEL 261DF BETWEEN FRAME 66 TO 68 & BETWEEN Y765 TO -Y765. REPLACED FLOOR PANEL IAW SRM 53-02-00, FIG 209.SDR USAA2013082700029Floor Panel · delaminated2S CHECK - DELAMINATION ON FLOOR PANEL 261BG BETWEEN FRAMES 64 TO 66 & BETWEEN Y765 TO Y1732. REPLACED FLOOR PANEL IAW SRM 53-02-00, FIG 209.SDR USAA2013082700028Floor Panel · delaminated2S CHECK - DELAMINATION ON FLOOR PANEL 232XF BETWEEN FRAMES 32 TO 35 & BETWEEN Y765 TO Y1292. REPLACED FLOOR PANEL IAW SRM 53-02-00, FIG 209.SDR USAA2013082700027Floor Panel · delaminated2S CHECK - DELAMINATION ON FLOOR PANEL 221DF BETWEEN FRAMES 16 TO 21 & BETWEEN Y254 TO -Y254. REPLACED FLOOR PANEL IAW SRM 53-02-00, FIG 209.SDR USAA2013082700026Floor Panel · delaminated2S CHECK - DELAMINATION ON FLOOR PANEL 222EF BETWEEN FRAMES 16 TO 20 & BETWEEN -Y1292 TO -Y254. REPLACED FLOOR PANEL IAW SRM 53-02-00, FIG 209.SDR USAA2013082700021Floor Panel · delaminated2S CHECK - DELAMINATION ON AFT CARGO FLOOR PANEL 151GF BETWEEN FRAMES 58 TO 59 & BETWEEN S32-38L. REPLACED AFT CARGO FLOOR PANEL IAW SRM 53-02-00, FIG 209.SDR USAA2013082600028Girt Bar · out of adjustR4 DOOR PRESSURE DIFFERENTIAL LIGHT ILLUMINATED RED IN FLIGHT. DOOR NO LONGER SHOWS ARMED ON THE ECAM DOOR PAGE. GIRT BAR OUT OF ADJUSTMENT.SDR USAA2013082200011Power Supply · failedFWD LT EPSU FAILED TEST. R & R FWD LT EPSU IAW AMM 33-51-38-400-001-A.SDR USAA2013082800014Seat Track · corroded2S CHECK - CORROSION ON SEAT TRACK BETWEEN FRAMES 16 TO 20, Y1292. REPLACED SEAT TRACK IAW SRM 51-74-00, 53-11-14, FIG 102 & 51-42-11.SDR USAA2013082800023Shear Plate · cracked2S CHECK - CRACK ON LATERAL SHEAR PLATE BETWEEN FRAMES 68 TO 69, S23R. REPLACED SHEAR PLATE IAW SRM 51-42-11.SDR USAA2013082800022Floor Support · corroded2S CHECK - CORROSION ON FLOOR SUPPORT BETWEEN FR68 TO FR69 & BETWEEN-Y1292 TO -Y1162. REPLACED FLOOR SUPPORT IAW SRM 51-42-11.SDR USAA2013082800019Floor Support · corroded2S CHECK - CORROSION ON FLOOR SUPPORT BETWEEN FRAMES 67 TO 68 & -Y1292 TO -Y1162. REPLACED FLOOR SUPPORT IAW SRM 51-42-11, 51-75-12 & 53-00-14, FIG 102.SDR USAA2013082800010Floorbeam · corroded2S CHECK - CORROSION ON FLOORBEAM AT FR 66, -Y1292. REPLACED FLOORBEAM IAW SRM 51-42-11 & 51-75-12.SDR USAA2013082300008Light · missingLAV L EMERGENCY LIGHT MODULE MISSING. INSTALLED EMERGENCY LIGHT MODULE AT LAV L.SDR USAA2013082900024Web · corroded2S CHECK - CORROSION FOUND ON WEB AT FRAME 16, -Y1584. REPLACED WEB IAW SRM 51-74-00 & 51-42-11.SDR USAA2013082900018Seat Track · corroded2S CHECK - CORROSION ON SEAT TRACK BETWEEN FRAMES 64 TO 66, Y1292. REPLACED SEAT TRACK IAW SRM 53-00-14, FIG 102 & 51-42-11.SDR USAA2013082800026Shear Plate · corroded2S CHECK - CORROSION ON SHEAR PLATE BETWEEN FRAMES 69 TO 70, S23R. REPLACED SHEAR PLATE IAW SRM 51-74-00 & 51-42-11.SDR USAA2013082800025Shear Plate · corroded2S CHECK - CORROSION ON SHEAR PLATE BETWEEN FRAMES 69 TO 70, S23L. REPLACED SHEAR PLATE IAW SRM 51-74-00 & 51-42-11.SDR USAA2013082800021Floor Support · corroded2S CHECK - CORROSION ON FLOOR SUPPORT BETWEEN FRAMES 68 TO 69 & Y1292 TO Y1162. REPLACED FLOOR SUPPORT IAW SRM 53-00-14, FIG 102 & 51-42-11.SDR USAA2013082800018Floor Support · corroded2S CHECK - CORROSION ON FLOOR SUPPORT BETWEEN FRAMES 66 TO 68 & Y1292 TO Y1162. REPLACED FLOOR SUPPORT IAW SRM 51-42-11 & 53-00-14, FIG.102.SDR USAA2013082200010Light · bentEMERGENCY EXIT LIGHT AT SEAT 9D BENT AND PARTIALLY DETACHED. STRAIGHTENED AND SECURED EMERGENCY LIGHT.SDR USAA2013082900022Dummy Rail · corroded2S CHECK - CORROSION FOUND ON DUMMY RAIL BETWEEN FRAMES 13 TO 16, -Y81. REPLACED DUMMY RAIL IAW SRM 53-11-14, FIG 101 & 51-42-11.SDR USAA2013082900014Sill · corroded2S CHECK - CORROSION FOUND ON L4 DOOR SILL AREA BETWEEN FRAMES 66 TO 68, S23L. REPLACED DOOR SILL IAW SRM 53-41-14, FIG 101 & 51-42-11.SDR USAA2013082700025Floor Panel · cracked2S CHECK - CRACK IN FLOOR PANEL 232MF BETWEEN FRAMES 24 TO 28 & BETWEEN -Y1292 TO -Y765. REPLACED FLOOR PANEL IAW SRM 53-02-00, FIG 209.SDR USAA2013082700024Floor Panel · delaminated2S CHECK - DELAMINATION ON FLOOR PANEL 232FF BETWEEN FRAMES 20 TO 24 & BETWEEN -Y1732 TO -Y1292. REPLACED FLOOR PANEL IAW SRM 53-02-00, FIG 209.SDR USAA2013082700023Floor Panel · corroded2S CHECK - CRACK IN FLOOR PANEL 231GF BETWEEN FRAMES 20 TO 24 & BETWEEN Y765 TO Y1292. REPLACED FLOOR PANEL IAW SRM 53-02-00, FIG 209.SDR USAA2013082700022Floor Panel · delaminated2S CHECK - DELAMINATION ON FLOOR PANEL 222CF BETWEEN FRAMES 12 TO 16 & BETWEEN Y81 TO Y1732. REPLACED FLOOR PANEL IAW SRM 53-02-00, FIG 209.SDR USAA2013082100012Bottle · low pressureEMERGENCY DOOR ASSIST BOTTLE HAS LOW PRESSURE AT R3 DOOR. SERVICED ASSIST BOTTLE IAW AMM 52-22-00-614-002-A.SDR USAA2013082200014Attach Fitting · brokenDURING 2S CHECK, TAB LUG BROKEN ON RT ELEVATOR HINGE ARM FITTING BETWEEN ELEVATOR STA 5274 TO 5894 & BETWEEN RIB 12 TO 13. REPAIRED RT ELEVATOR TAB LUG AT HINGE ARM FITTING IAW SRM 55-26-41 & 51-75-12.SDR USAA2013082900021Web · corroded2S CHECK - CORROSION FOUND ON WEB AT FRAME 20, -Y1732. REPLACED WEB IAW SRM 51-74-04, 51-42-11 & 51-42-00.SDR USAA2013082900016Floor Support · corroded2S CHECK - CORROSION ON FLOOR SUPPORT BETWEEN FRAMES 20 TO 21, Y1732. REPLACED FLOOR SUPPORT IAW SRM 51-74-00, 51-42-11 & 51-75-12.SDR USAA2013082800024Shear Plate · cracked2S CHECK -CRACK ON SHEAR PLATE BETWEEN FRAMES 68 TO 69, S23L. REPLACED SHEAR PLATE IAW SRM 51-42-11 & 51-44-11.SDR USAA2013082800017Floor Support · corroded2S CHECK - CORROSION ON FLOOR SUPPORT BETWEEN FRAMES 65 TO 67, -Y465. REPLACED FLOOR SUPPORT IAW SRM 51-42-11 & 53-00-14, FIG 102.
Back to Airbus A321-211