What was found
2S CHECK - CORROSION ON FLOOR SUPPORT BETWEEN FRAMES 67 TO 68 & -Y1292 TO -Y1162. REPLACED FLOOR SUPPORT IAW SRM 51-42-11, 51-75-12 & 53-00-14, FIG 102.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
2S CHECK - CORROSION ON FLOOR SUPPORT BETWEEN FRAMES 67 TO 68 & -Y1292 TO -Y1162. REPLACED FLOOR SUPPORT IAW SRM 51-42-11, 51-75-12 & 53-00-14, FIG 102.