Airbus A321-231
Service difficulty reports · 20,673
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A321231' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A321231' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA202509249384Bottle · low pressureAIRCRAFT WAS NOT GROUNDED: R3 DOOR DAMPER AND EMERGENCY OPERATION CYLINDER PRESSURE LOW. SERVICED DOOR DAMPER AND EMERGENCY OPERATION CYLINDER PER AMM 52-22-00.SDR AALA202509253142Flashlight · no testAIRCRAFT WAS NOT GROUNDED: FORWARD FLIGHT ATTENDANT FLASHLIGHT BRACKET IS LOOSE AND DOES NOT TEST UNDER 1B JUMP SEAT. MAINTENANCE REPLACED THE ENTIRE FLASHLIGHT BRACKET SYSTEM ASSEMBLY PER CMM 25-60-02 AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK WITH NO SDR AALA202509246681Battery · no testAIRCRAFT WAS NOT GROUNDED: BATTERY FAULT MESSAGE FOR EMERGENCY POWER SUPPLY UNIT 15WL DISPLAYED DURING SYSTEM TEST. REPLACED BATTERY AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK PER AMM 33-51-38 WITH NO FAULTS NOTED.SDR AALA202509241428Battery · no testAIRCRAFT WAS NOT GROUNDED: BATTERY FAULT MESSAGE FOR EMERGENCY POWER SUPPLY UNIT 10WL DISPLAYED DURING SYSTEM TEST. REPLACED BATTERY AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK PER AMM 33-51-38 WITH NO FAULTS NOTED.SDR AALA202509249169Bottle · low pressureAIRCRAFT WAS NOT GROUNDED: FLIGHT ATTENDANTS CIDS PANEL DISPLAYS CHECK DOOR PRESSURE WITH NO OTHER INDICATIONS ON ECAM. MAINTENANCE SERVICED L1 DOOR DAMPER AND EMERGENCY OPERATION CYLINDER PER AMM 52-10-00 WHICH CLEARED THE FAULT MESSAGE ON THE CIDS PANEL.SDR AALA202509239658Battery · no testAIRCRAFT IN BASE MAINTENANCE: BATTERY FAULT FOR EMERGENCY POWER SUPPLY UNIT 11WL DISPLAYED DURING SYSTEM TEST. REPLACED BATTERY AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK PER AMM 33-51-38 WITH NO FAULTS NOTED.SDR GTIA2025101439130Panel · corrodedCORROSION UPPER SURFACE LOC. BTW RIB 5 TO RIB 6 REAR SPAR AREA ON RH WING RAF 3525563-02 GENERATED -PERFORMED PERMANENT REPAIR UPPER SURFACE LOC. BTW RIB 6 REAR SPAR AREA ON RH WING I.A.W EA #57-0095-25. THIS REPAIR IS CATEGORY A AND NOT REQUIRED FUTURE INSPECSDR GTIA2025101439129Panel · corrodedCORROSION UPPER SURFACE LOC. BTW RIB 4 TO RIB 6 REAR SPAR AREA ON LH WING RAF 3525563-01 CREATED SEE APPENDIX 3525563-01-PERFORMED PERMANENT REPAIR LOC. ON UPPER SURFACE BTW RIB 4 TO RIB 6 REAR SPAR AREA ON LH WING I.A.W EA # 57-0097-25. THIS REPAIR IS CATEGORSDR GTIA2025101439128Panel · corrodedCORROSION UPPER SURFACE LOC. BTW RIB 4 TO RIB 5 REAR SPAR AREA ON RH WING RAF-01 3525564-01 GENERATED -PERFORMED PERMANENT REPAIR UPPER SURFACE LOC. BTW RIB 4 TO RIB 5 REAR SPAR AREA ON RH WING I.A.W EA #57-0095-25. THIS REPAIR IS CATEGORY A. AND NOT REQUIRED SDR GTIA2025F00008Panel · corrodedCORROSION UPPER SURFACE LOC. BTW RIB 4 TO RIB 6 REAR SPAR AREA ON LH WING RAF 3525563-01 CREATED SEE APPENDIX 3525563-01-PERFORMED PERMANENT REPAIR LOC. ON UPPER SURFACE BTW RIB 4 TO RIB 6 REAR SPAR AREA ON LH WING I.A.W EA # 57-0097-25. THIS REPAIR IS CATEGORSDR GTIA2025F00007Panel · corrodedCORROSION UPPER SURFACE LOC. BTW RIB 4 TO RIB 5 REAR SPAR AREA ON RH WING RAF-01 3525564-01 GENERATED -PERFORMED PERMANENT REPAIR UPPER SURFACE LOC. BTW RIB 4 TO RIB 5 REAR SPAR AREA ON RH WING I.A.W EA #57-0095-25. THIS REPAIR IS CATEGORY A. AND NOT REQUIRED SDR AALA202509291004Bottle · low pressureAIRCRAFT IN BASE MAINTENANCE: R3 EMERGENCY DOOR PRESSURE IS LOW. MAINTENANCE SERVICED R3 EMERGENCY DOOR DAMPER IAW AMM 52-22-00-614-002-A.SDR AALA202509264664Bottle · low pressureAIRCRAFT IN BASE MAINTENANCE, L1 DOOR DAMPER AND EMERGENCY OPERATION CYLINDER PRESSURE LOW. SERVICED DOOR DAMPER AND EMERGENCY OPERATION CYLINDER PER AMM 52-10-00.SDR AALA202509233304Battery · no testAIRCRAFT IN BASE MAINTENANCE: FAULT DISPLAYED FOR EMERGENCY POWER SUPPY UNIT 15WL DURING SYSTEM TEST. REPLACED EMERGENCY POWER SUPPLY UNIT 15WL (AALA202509230268) AND BATTERY (AALA202509234928) PER AMM 33-51-38. A SATISFACTORY OPERATIONAL CHECK WAS ACCOMPLISHESDR AALA202509238712Bottle · low pressureAIRCRAFT WAS NOT GROUNDED: R4 DOOR DAMPER AND EMERGENCY OPERATION CYLINDER PRESSURE LOW. SERVICED DOOR DAMPER AND EMERGENCY OPERATION CYLINDER PER AMM 52-10-00.SDR AALA202509230527Power Supply · no testAIRCRAFT IN BASE MAINTENANCE: FAULT DISPLAYED FOR EMERGENCY POWER SUPPY UNIT 15WL DURING SYSTEM TEST. REPLACED EMERGENCY POWER SUPPLY UNIT 15WL (AALA202509230268) AND BATTERY (AALA202509234928) PER AMM 33-51-38. A SATISFACTORY OPERATIONAL CHECK WAS ACCOMPLISHESDR AALA202510133934Strip · splitAIRCRAFT IN BASE MAINTENANCE: TRAILING EDGE OF RUDDER ON THE LOWER CORNER IS SPLITTING AND HAS A PULLED RIVET. REPAIRED RUDDER APEX STRIP PER SRM 55-41-19-300-004.SDR AALA202509263934Skin · damagedAIRCRAFT IN BASE MAINTENANCE: TRAILING EDGE OF RUDDER ON THE LOWER CORNER IS SPLITTING AND HAS A PULLED RIVET. (OPEN)SDR AALA202509228703Wire · brokenAIRCRAFT WAS NOT GROUNDED: SEAT MOUNTED EMERGENCY LIGHTS ROWS 32 AND 33 ABC ARE INOPERATIVE. MAINTENANCE FOUND BROKEN WIRE, REPAIRED WIRE AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK PER AMM 33-51-00.SDR AALA202510164181Fitting · wornAIRCRAFT IN BASE MAINTENANCE: AFT AVIONIC COMPARTMENT RACK 80VU LEFT HAND LATERAL FITTING WORN BETWEEN FR 23 AND FR 24 AT +Y1263. REPLACED LEFT HAND LATERAL FITTING PER EA 368345.SDR AALA202510166160Fitting · wornAIRCRAFT IN BASE MAINTENANCE: AFT AVIONIC COMPARTMENT RACK 80VU RIGHT HAND LATERAL FITTING WORN BETWEEN FR 23 AND FR 24 AT -Y1263. REPLACED RIGHT HAND LATERAL FITTING PER EA 368345.SDR AALA202509225350Apu · contaminatedAIRCRAFT WAS GROUNDED: IN DESCENT WITH POWER AT IDLE SLIGHT MUSTY SMELL FROM PACKS. MAINTENANCE FOUND A RESIDUAL HYDRAULIC FLUID STREAK FRM THE RIGHT-HAND MAIN LANDING GEAR WHEEL WELL TO THE APU INLET. A LEAK CHECK OF THE HYDRAULIC SYSTEM RESULTED IN NO LEAKS SDR AALA202509223492Power Supply · no testAIRCRAFT WAS GROUNDED: FAULT MESSAGE FOR EMERGENCY POWER SUPPLY UNIT 10WL DISPLAYED DURING SYSTEM TEST. MAINTENANCE ISOLATED THE ISSUE TO THE L1 DOOR SLIDE ASSEMBLY, REPLACED THE SLIDE ASSEMBLY AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK PER TASK CARD 26SDR AALA202509226273Connector · out of adjustAIRCRAFT IN BASE MAINTENANCE: RED SEAT MOUNTED EMERGENCY AISLE LIGHT ON LEFT HAND SEAT ROW 11 DOES NOT ILLUMINATE. MAINTENANCE ADJUSTED CONNECTOR FOR THE RED SEAT MOUNTED EMERGENCY AISLE LIGHT ON LEFT HAND SEAT ROW 11 PER AMM 20-18-01 AND ACCOMPLISHED A SATISFSDR AALA202509229472Battery · no testAIRCRAFT WAS GROUNDED: BATTERY FAULT MESSAGE DISPLAYED FOR EMERGENCY POWER SUPPLY UNIT 14WL DURING SYSTEM TES. REPLACED BATTERY AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK PER AMM 33-51-38.SDR AALA202509222869Slide Raft · unraveledAIRCRAFT IN BASE MAINTENANCE: WHILE INSTALLING THE LEFT AFT PASSENGER / CREW DOOR SLIDE, THE UNDER SKIRT OF THE SLIDE WHERE RETAINING BALLS MEET THE SLIDE PLATE, THE SLIDE UNRAVELED AFTER NYLON LACING WAS CUT.REPLACED SLIDE RAFT PER TASK CARD 26L00025011.SDR AALA202509194072Bottle · low pressureAIRCRAFT WAS NOT GROUNDED: L2 DOOR DAMPER AND EMERGENCY OPERATION CYLINDER PRESSURE LOW. SERVICED DOOR DAMPER AND EMERGENCY OPERATION CYLINDER PER AMM 52-22-00.SDR AALA202510206332Hook · deterioratedAIRCRAFT IN BASE MAINTENANCE: PASSENGER / CREW DOOR 841 STAY MECHANISM HOOK WHEN IN THE LOCKED POSITION IS DETERIORATED. REPLACED STAY MECHANISM AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK PER AMM 52-11-12.SDR AALA202510021124Hinge Fitting · excess playAIRCRAFT IN BASE MAINTENANCE: EXCESSIVE PLAY ON ELEVATOR HINGE ARM END FITTING #6 ON LH HORIZONTAL STABILIZER. MAINTENANCE REPLACED ELEVATOR HINGE ARM END FITTING # 6 ON LH HORIZONTAL STABILIZER IAW AMM 55-16-42-000-001-A AND AMM 55-16-42-400-001-A.SDR AALA202510026258Hinge Fitting · excess playAIRCRAFT IN BASE MAINTENANCE: EXCESSIVE PLAY ON ELEVATOR HINGE ARM END FITTING #5 ON LH HORIZONTAL STABILIZER. MAINTENANCE REPLACED ELEVATOR HINGE ARM END FITTING # 5 ON LH HORIZONTAL STABILIZER IAW AMM 55-16-42-000-001-A AND AMM 55-16-42-400-001-A.SDR AALA202509194308Battery · no testAIRCRAFT IN BASE MAINTENANCE: FAULT MESSAGE FOR EMERGENCY POWER SUPPLY UNIT 12WL DISPLAYED DURING SYSTEM TEST. REPLACED BATTERY FOR EMERGENCY POWER SUPPLY UNIT 12WL AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK PER AMM 33-51-38.SDR AALA202509190021Battery · no testAIRCRAFT IN BASE MAINTENANCE: FAULT MESSAGE FOR EMERGENCY POWER SUPPLY UNIT 13WL DISPLAYED DURING SYSTEM TEST. REPLACED BATTERY FOR EMERGENCY POWER SUPPLY UNIT 13WL AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK PER AMM 33-51-38.SDR AALA202509193779Screw · looseAIRCRAFT WAS NOT GROUNDED: FLIGHT DECK DOOR IS DIFFICULT TO OPERATE AND UPPER LATCH DOES NOT ENGAGE. LATCH IS ABOUT 1/2" AWAY FROM ENABLING CLOSURE. MAINTENANCE FOUND SCREW LOOSE ON FIGHT DECK DOOR FRAME, SECURED SCREW AND ACCOMPLISHED A SATISFACTORY OPERATIONSDR AALA202509197913Battery · no testAIRCRAFT WAS NOT GROUNDED: BATTERY FAULT FOR EMERGENCY POWER SUPPLY UNIT 11WL DISPLAYED DURING SYSTEM TEST. REPLACED BATTERY AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK PER AMM 33-51-38.SDR AALA202509194734Handle · looseAIRCRAFT WAS NOT GROUNDED: DOOR 3R ARMING HANDLE LOOSE. MAINTENANCE RESECURED ARM/DISARM HANDLE PER AMM 52-22-22.SDR AALA202510063849Hinge Fitting · excess playAIRCRAFT IN BASE MAINTENANCE: EXCESSIVE PLAY ON ELEVATOR HINGE ARM END FITTING # 3 ON RH HORIZONTAL STABILIZER. MAINTENANCE REPLACED ELEVATOR HINGE ARM END FITTING # 3 ON RH HORIZONTAL STABILIZER IAW AMM 55-16-42-000-001-A AND AMM 55-16-42-400-001-A.SDR AALA202510064372Hinge Fitting · excess playAIRCRAFT IN BASE MAINTENANCE: EXCESSIVE PLAY ON ELEVATOR HINGE ARM END FITTING #6 ON RH HORIZONTAL STABILIZER. MAINTENANCE REPLACED ELEVATOR HINGE ARM END FITTING # 6 ON RH HORIZONTAL STABILIZER IAW AMM 55-16-42-000-001-A AND AMM 55-16-42-400-001-A.SDR AALA202510067090Hinge Fitting · excess playAIRCRAFT IN BASE MAINTENANCE: EXCESSIVE PLAY BEARING OF THE ELEVATOR HINGE ARM END FITTING #1ON RH HORIZONTAL STABILIZER. MAINTENANCE REPLACED ELEVATOR HINGE ARM END FITTING # 1 ON RH HORIZONTAL STABILIZER IAW AMM 55-16-42-000-001-A AND AMM 55-16-42-400-001-ASDR AALA202510064758Hinge Fitting · excess playAIRCRAFT IN BASE MAINTENANCE: EXCESSIVE PLAY ON ELEVATOR HINGE ARM END FITTING # 2 ON RH HORIZONTAL STABILIZER. MAINTENANCE REPLACED ELEVATOR HINGE ARM END FITTING # 2 ON RH HORIZONTAL STABILIZER IAW AMM 55-16-42-000-001-A AND AMM 55-16-42-400-001-A.SDR AALA202510069196Hinge Fitting · excess playAIRCRAFT IN BASE MAINTENANCE: EXCESSIVE PLAY ON ELEVATOR HINGE ARM END FITTING # 4 ON RH HORIZONTAL STABILIZER. MAINTENANCE REPLACED ELEVATOR HINGE ARM END FITTING # 4 ON RH HORIZONTAL STABILIZER IAW AMM 55-16-42-000-001-A AND AMM 55-16-42-400-001-A.SDR AALA202510067168Hinge Fitting · excess playAIRCRAFT IN BASE MAINTENANCE: EXCESSIVE PLAY ON ELEVATOR HINGE ARM END FITTING # 5 ON RH HORIZONTAL STABILIZER. MAINTENANCE REPLACED ELEVATOR HINGE ARM END FITTING # 5 ON RH HORIZONTAL STABILIZER IAW AMM 55-16-42-000-001-A AND AMM 55-16-42-400-001-A.SDR AALA202510040675Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON AFT CABIN FLOORBEAM BETWEEN FR 65 AND FR 67 AT+Y919. REPLACED FLOORBEAM PER SRM 51-42-11-801.SDR AALA202509261653Hinge Fitting · excess playAIRCRAFT IN BASE MAINTENANCE: RIGHT HAND HORIZONTAL STABILIZER ELEVATOR #2 HINGE ARM END FITTING HAS EXCESSIVE PLAY. REPLACED HINGE ARM END FITTING PER AMM 55-16-42.SDR AALA202509269576Hinge Fitting · excess playAIRCRAFT IN BASE MAINTENANCE: RIGHT HAND HORIZONTAL STABILIZER ELEVATOR #1 HINGE ARM END FITTING HAS EXCESSIVE PLAY. REPLACED HINGE ARM END FITTING PER AMM 55-16-42.SDR AALA202509261563Hinge Fitting · excess playAIRCRAFT IN BASE MAINTENANCE: RIGHT HAND HORIZONTAL STABILIZER ELEVATOR #3 HINGE ARM END FITTING HAS EXCESSIVE PLAY. REPLACED HINGE ARM END FITTING PER AMM 55-16-42.SDR GTIA2025091839080Megaphone · inoperativeLOUD SQUEAL FROM L1 DOOR STARTED ON DES AT DP 7.9 AND STOPPED AT DP 6.4-PERFORMED OPS TEST OF CABIN PRESSUERIZATION IAW AMM 21-31-00. FOUND L1 DOOR MEGAPHONE MALFUNCTION. R/R L1 DOOR MEGAPHONE IAW CMM 25-64-00. OPS CHECK GOOD. NO DEFECTS NOTED. A/C OK FOR SVCDSDR AALA202509181868Lanyard · out of positionAIRCRAFT WAS NOT GROUNDED: R1 DOOR HAS A CABLE HANGING FROM THE BOTTOM OF THE DOOR. MAINTENANCE RE-STOWED R1 DOOR SLIDE LANYARD PER AMM 25-62-44.SDR AALA202509186753Connector · looseAIRCRAFT WAS NOT GROUNDED: SEAT 1C EMERGENCY EXIT LIGHT INOPERATIVE. MAINTENANCE RE-SECURED BAD CONNECTION AT 1C SEAT MOUNTED EMERGENCY LIGHT PER AMM 33-51-19. A SATISFACTORY OPERATIONAL CHECK WAS ACCOMPLISHED PER AMM 33-51-00.SDR AALA202509183326Flashlight · inoperativeAIRCRAFT WAS NOT GROUNDED: FLIGHT ATTENDANT #3 FLASHLIGHT INOPERATIVE. MAINTENANCE REPLACED FLASHLIGHT AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK PER AMM 25-60-00.SDR AALA202510064804Floor Support · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON FORWARD CABIN FLOOR BEAM BETWEEN FR 12 AND FR 20 AT +Y1292. REPLACED FLOOR BEAM PER SRM 51-42-11.
Back to Airbus A321-231