Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR AALA202410087883Accumulator · low pressureAIRCRAFT WAS GROUNDED: RIGHT AFT CABIN DOOR ACCUMULATOR LOW. SERVICED DOOR ACCUMULATOR PER AMM 52-13-00.Oct 7, 2024 · N951XV · Airbus A321253N · Passenger/Crew DoorsSDR AALA202410016418Bottle · low pressureAIRCRAFT WAS NOT GROUNDED: LEFT HAND FORWARD EMERGENCY EXIT DOOR CYLINDER/ACCUMULATOR HAS LOW PRESSURE. SERVICED AS REQUIRED LEFT HAND FORWARD EMERGENCY EXIT DOOR CYLINDER/ACCUMULATOR.Sep 30, 2024 · N956XV · Airbus A321253N · Emergency ExitsSDR AALA202409308454Connector · not seatedAIRCRAFT WAS NOT GROUNDED: CABIN EMERGENCY DOME LIGHT WON'T TURN ON (ROW 11). RESEATED CONNECTORS FOR ER DOME LIGHT AT ROW 11.Sep 29, 2024 · N957XV · Airbus A321253N · Light System WiringSDR AALA202409301986Connector · looseAIRCRAFT WAS NOT GROUNDED: CABIN EMERGENCY DOME LIGHT WON'T TURN ON (ROW 21). RESEATED CONNECTORS FOR ER DOME LIGHT AT ROW 21.Sep 29, 2024 · N957XV · Airbus A321253N · Light System WiringSDR AALA202409303348Bottle · low pressureAIRCRAFT WAS NOT GROUNDED: DOOR 3R PRESSURE REQUIRE SERVICE. PRESSURE SERVICED AS REQUIRED IAW AMM 12-00-00.Sep 29, 2024 · N950XV · Airbus A321253N · Emergency EquipmentSDR AALA202409301776Lever · looseAIRCRAFT WAS NOT GROUNDED: 2R EMERGENCY EXIT ARM/DISARM LEVER LOOSE. SECURED 2R EMERGENCY EXIT ARM / DISARM LEVER BY TIGHTENING ATTACHMENT HARDWARE IN PLACE.Sep 29, 2024 · N956XV · Airbus A321253N · Emergency ExitsSDR AALA202409205134Circuit Breaker · trippedAIRCRAFT WAS GROUNDED: CABIN EMERGENCY LIGHTS CIRCUIT BREAKER H7 TRIPPED DURING BOARDING. REMOVED AND REPLACED EMERGENCY LIGHT SWITCH 4WL.Sep 19, 2024 · N951XV · Airbus A321253N · Light System WiringSDR AALA202409168072Bottle · low pressureAIRCRAFT WAS NOT GROUNDED: DURING PERFORMING PS CHECK FOUND L2 DOOR ACCUMULATOR PRESSURE LOW. SERVICED L2 DOOR ACCUMULATOR WITH NITROGEN.Sep 14, 2024 · N952XV · Airbus A321253N · Emergency ExitsSDR AALA202409101616Bottle · low pressureAIRCRAFT WAS NOT GROUNDED: LEFT HAND AFT 834 DOOR DAMPER PRESSURE LOW. RECHARGED L3 DOOR DAMPER.Sep 10, 2024 · N959XV · Airbus A321253N · Passenger/Crew DoorsSDR AALA202409100537Bottle · low pressureAIRCRAFT WAS NOT GROUNDED: RIGHT AFT 844 DOOR DAMPER PRESSURE LOW. RECHARGED R3 DOOR DAMPER.Sep 10, 2024 · N959XV · Airbus A321253N · Service DoorsSDR AALA202409102284Bottle · low pressureAIRCRAFT WAS NOT GROUNDED: R2 DOOR ASSIST BOTTLE PRESSURE LOW. SERVICED DOOR AS REQUIRED PER AMM 52-22-00.Sep 9, 2024 · N953XV · Airbus A321253N · Emergency EquipmentSDR AALA202409101413Bottle · low pressureAIRCRAFT WAS NOT GROUNDED: L3 DOOR ASSIST BOTTLE PRESSURE LOW. SERVICED DOOR AS REQUIRED PER AMM 52-22-00.Sep 9, 2024 · N953XV · Airbus A321253N · Emergency EquipmentSDR AALA202409104893Bottle · low pressureAIRCRAFT WAS NOT GROUNDED: L4 EMERGENCY DOOR BOTTLE PRESSURE BELOW LIMITS. SERVICED L4 EMERGENCY DOOR BOTTLE IAW AMM 52-10-00, PRESSURE CHK GOOD. NO LEAKS NOTED.Sep 9, 2024 · N956XV · Airbus A321253N · Emergency EquipmentSDR AALA202409034924Flashlight · inoperativeAIRCRAFT WAS NOT GROUNDED: BATTERY FLASHLIGHT INOPERATIVE AT OUTBOARD FLIGHT ATTENDANT SEAT L1 DOOR. REPLACED BATTERY FLASHLIGHT PER AMM 25-65-99.Sep 2, 2024 · N951XV · Airbus A321253N · Emergency EquipmentSDR AALA202409038994Bottle · low pressureAIRCRAFT WAS GROUNDED: L4 SERVICE DOOR ACCUMULATOR REQUIRES SERVICING. SERVICED L4 DOOR ACCUMULATOR IAW AMM 52-10-00.Aug 31, 2024 · N959XV · Airbus A321253N · Passenger/Crew DoorsSDR AALA202408300834Damper Plate · low pressureAIRCRAFT WAS NOT GROUNDED: WHILE ACCOMPLISHING JOB CARD 26L0000505, FOUND R4 DOOR EMERGENCY CYLINDER LOW. 1200PSI AT 68F. SERVICED R4 DOOR EMERGENCY CYLINDER IAW AMM 52-10-00-614-001-A, AND 52-22-00-614-002-A.Aug 28, 2024 · N950XV · Airbus A321253N · Emergency EquipmentSDR AALA202408309167Bottle · low pressureAIRCRAFT WAS NOT GROUNDED: WHILE ACCOMPLISHING JOB CARD 26L0000505, FOUND L3 DOOR EMERGENCY CYLINDER LOW. 1200PSI AT 68F. SERVICED L3 DOOR EMERGENCY CYLINDER IAW AMM 52-10-00-614-001-A, AND 52-22-00-614-002-A.Aug 28, 2024 · N950XV · Airbus A321253N · Emergency EquipmentSDR AALA202408306606Bottle · low pressureAIRCRAFT WAS NOT GROUNDED: AFT EMERGENCY EXIT DOOR (L3) DAMPENER LOW PSI (1200 PSI AT 80F). SERVICED L3 DOOR IAW AMM 52-22-00.Aug 28, 2024 · N953XV · Airbus A321253N · Emergency EquipmentSDR AALA202408266662Bottle · low pressureAIRCRAFT WAS NOT GROUNDED: L2 EMERGENCY DOOR DAMPER BELOW PRESSURE LIMIT. SERVICED L2 EMERGENCY DOOR DAMPER TO CORRECT PRESSURE IAW AMM 52-22-00Aug 25, 2024 · N956XV · Airbus A321253N · Emergency EquipmentSDR AALA202408264979Damper · low pressureAIRCRAFT WAS NOT GROUNDED: R1 DOOR BOTTLE LOW. SERVICED DOOR BOTTLE IAW MM 52-22-00 LEAK CHECK GOOD.Aug 24, 2024 · N951XV · Airbus A321253N · Emergency EquipmentSDR AALA202408266431Bottle · low pressureAIRCRAFT WAS NOT GROUNDED: L4 EMERGENCY CYLINDER ACCUMULATOR PRESSURE BELOW LIMITS. TEMP 80 DEGREES F. R4-1000PSI L4-1100PSI. SERVICED R4 AND L4 DOOR ACCUMULATORS TO CORRECT PRESSURE IAW AMM 52-10-00Aug 24, 2024 · N956XV · Airbus A321253N · Emergency EquipmentSDR AALA202408261845Bottle · low pressureAIRCRAFT WAS NOT GROUNDED: R4 EMERGENCY CYLINDER ACCUMULATOR PRESSURE BELOW LIMITS.TEMP 80 DEGREES F. R4-1000PSI L4-1100PSI. SERVICED R4 DOOR ACCUMULATORS TO CORRECT PRESSURE IAW AMM 52-10-00Aug 24, 2024 · N956XV · Airbus A321253N · Emergency EquipmentSDR AALA202408191634Bottle · low pressureAIRCRAFT WAS NOT GROUNDED: R3 EMERGENCY EXIT DOOR DAMPER REQUIRES NITROGEN SERVICING. SERVICED R3 EMERGENCY EXIT DOOR DAMPER PER JC 26L00005005.Aug 18, 2024 · N950XV · Airbus A321253N · Emergency EquipmentSDR AALA202407299287Battery · inoperativeAIRCRAFT WAS NOT GROUNDED: BATTERY/EMERGENCY POWER SUPPLY UNIT (15WL) EXTERNAL LEFT CLASS 1 MAINTENANCE MESSAGE AFTER SYSTEM TEST. REMOVED AND REPLACED 15WL BATTERY.Jul 28, 2024 · N951XV · Airbus A321253N · Emergency LightingSDR AALA202407296264Battery · inoperativeAIRCRAFT WAS NOT GROUNDED: BATTERY/EMERGENCY POWER SUPPLY UNIT (11WL) EXTERNAL LEFT CLASS 1 MAINTENANCE MESSAGE AFTER SYSTEM TEST. REMOVED AND REPLACED 11WL BATTERY.Jul 28, 2024 · N951XV · Airbus A321253N · Emergency LightingSDR AALA202407296142Bottle · low pressureAIRCRAFT WAS NOT GROUNDED: 3L DOOR ASSIST BOTTLE PRESSURE LOW. CHARGED 3L DOOR CYLINDER BOTTLE PER AMM 52-10-00.Jul 26, 2024 · N954XV · Airbus A321253N · Emergency EquipmentSDR AALA202407290347Bottle · low pressureAIRCRAFT WAS NOT GROUNDED: R2 DOOR PRESSURE IS LOW SERVICE IS REQUIRED. SERVICED R2 DOOR DAMPER IAW AMM 52-10-00. LEAK CKD NO LEAKED NOTED.Jul 25, 2024 · N955XV · Airbus A321253N · Service DoorsSDR AALA202407297265Bottle · low pressureAIRCRAFT WAS NOT GROUNDED: R1 DOOR PRESSURE IS LOW SERVICE IS REQUIRED. SERVICED R1 DOOR DAMPER.Jul 25, 2024 · N955XV · Airbus A321253N · Passenger/Crew DoorsSDR AALA202407294631Damper · low pressureAIRCRAFT WAS NOT GROUNDED: L1 DOORS PRESSURE IS LOW SERVICE IS REQUIRED. SERVICED L1 DOOR DAMPER.Jul 25, 2024 · N955XV · Airbus A321253N · Passenger/Crew DoorsSDR AALA202407263115Bottle · low pressureAIRCRAFT WAS NOT GROUNDED: R3 DOOR ASSIST BOTTLE PRESSURE BELOW PS CHECK LIMIT. SERVICED AND CHARGED R3 DOOR ASSIST BOTTLE PER AMM 52-10-00.Jul 25, 2024 · N950XV · Airbus A321253N · Emergency EquipmentSDR AALA202407265646Bottle · low pressureAIRCRAFT WAS NOT GROUNDED: L4 DOOR ASSIST BOTTLE PRESSURE BELOW PS CHECK LIMIT. SERVICED AND CHARGED L4 DOOR ASSIST BOTTLE PER AMM 52-10-00.Jul 25, 2024 · N950XV · Airbus A321253N · Emergency EquipmentSDR AALA202407229882Bottle · low pressureAIRCRAFT WAS NOT GROUNDED: L/H AFT EMERGENCY DOOR PRESSURE LOW. SERVICE L/H AFT EMERGENCY EXIT DOOR DAMPER IAW AMM 52-22-00 LEAK AND OPERATIONAL CHECK OKAY.Jul 21, 2024 · N953XV · Airbus A321253N · Passenger/Crew DoorsSDR AALA202407123569Bottle · low pressureAIRCRAFT WAS NOT GROUNDED: L4 ACCUMULATOR LOW. SERVICED L4 DOOR ACCUMULATOR IAW AMM 52-22-00. NO LEAKS NOTED.Jul 11, 2024 · N956XV · Airbus A321253N · Emergency EquipmentSDR AALA202407116744Toilet · odorAIRCRAFT WAS GROUNDED: STRONG AMMONIA SMELL AT AFT GALLEY. SMELL WAS DETERMINED TO BE URINE. JOB CARD 26L00021001 WAS ACCOMPLISHED. LEFT AFT TOILET WAS REMOVED AND REPLACED PER AMM 38-31-41.Jul 9, 2024 · N951XV · Airbus A321253N · Waste Disposal SystemSDR AALA202407088894Bottle · low pressureAIRCRAFT WAS GROUNDED: R1 DOOR ASSIST BOTTLE PRESSURE LOW. SERVICED R1 DOOR ASSIST BOTTLE PER AMM 52-10-00. NO LEAKS NOTED.Jul 5, 2024 · N958XV · Airbus A321253N · Emergency EquipmentSDR AALA202407056243Bottle · low pressureAIRCRAFT WAS NOT GROUNDED: AFT RIGHT-HAND PASSENGER/SERVICE CABIN DOOR ACCUMULATOR/CYLINDER HAS LOW PRESSURE. SERVICED CYLINDER/ACCUMULATOR AT RIGHT-HAND AFT PASSENGER DOOR PER AMM 52-10-00.Jul 4, 2024 · N955XV · Airbus A321253N · Emergency EquipmentSDR AALA202407056784Bottle · low pressureAIRCRAFT WAS GROUNDED: AFT LEFT-HAND PASSENGER/SERVICES CABIN DOOR ACCUMULATOR/CYLINDER HAS LOW PRESSURE. SERVICED CYLINDER/ACCUMULATOR AT LEFT-HAND AFT PASSENGER DOOR PER AMM 52-10-00.Jul 4, 2024 · N955XV · Airbus A321253N · Passenger/Crew DoorsSDR AALA202407017422Life Vest · missingAIRCRAFT WAS NOT GROUNDED: FLIGHT CREW REPORTED THAT LIFEVEST AT SEAT 13C IS MISSING. INSTALLED LIFE VEST PER AMM 25-66-52.Jun 28, 2024 · N952XV · Airbus A321253N · Life JacketSDR AALA202406287185Bottle · low pressureAIRCRAFT WAS NOT GROUNDED: RH AFT EMERGENCY DOOR CYLINDER/ACCUMULATOR HAS LOW PRESSURE. SERVICED CYLINDER / ACCUMULATOR BOTTLE AT RH AFT EMERGENCY DOOR IAW AMM 52-10-00Jun 27, 2024 · N950XV · Airbus A321253N · Emergency EquipmentSDR AALA202406242654Bottle · low pressureAIRCRAFT WAS NOT GROUNDED: R3 EMERGENCY EXIT DOOR DAMPENER ASSIST BOTTLE BELOW PRESSURE LIMIT. SERVICED R3 DOOR DAMPENER ASSIST CHARGE BOTTLE TO PROPER PRESSURE RANGE IAW AMM 52-10-00, OPS/LEAK CHECK OK.Jun 22, 2024 · N959XV · Airbus A321253N · Emergency EquipmentSDR AALA202406249251Bottle · low pressureAIRCRAFT WAS NOT GROUNDED: L4 SERVICE DOOR DAMPENER ASSIST BOTTLE BELOW PRESSURE LIMITS & REQUIRED SERVICE. SERVICED L4 DOOR DAMPENER ASSIST BOTTLE TO PROPER PRESSURE IAW AMM 52-10-00, OPS/LEAK CHECK OK.Jun 22, 2024 · N959XV · Airbus A321253N · Emergency EquipmentSDR AALA202406211531Bottle · low pressureAIRCRAFT WAS GROUNDED: L1 DOOR DAMPER AND EMERGENCY OPERATION CYLINDER NEEDS TO BE SERVICED. MAINTENANCE SERVICED THE L1 DOOR DAMPER AND EMERGENCY OPERATION CYLINDER PER AMM 52-10-00.Jun 21, 2024 · N951XV · Airbus A321253N · Emergency EquipmentSDR AALA202406187249Strap · unsecureAIRCRAFT WAS NOT GROUNDED: FLIGHT CREW REPORTED STRAP HANGING DOWN FROM SLIDE PACK AT 4L DOOR WHEN DOOR IS OPEN. STRAP WAS HANGING OUT CLOSED DOOR IN AUS. PULLED INSIDE BEFORE DEPARTURE. MAINTENANCE RE-SECURED STRAP PER AMM 25-62-00.Jun 17, 2024 · N953XV · Airbus A321253N · Escape SlideSDR AALA202406106314Battery · inoperativeAIRCRAFT WAS NOT GROUNDED: AFT MEGAPHONE INOPERATIVE. REPLACED BATTERIES IN AFT MEGAPHONE.Jun 9, 2024 · N957XV · Airbus A321253N · Emergency EquipmentSDR AALA202406077275Buckle · brokenAIRCRAFT IN BASE MAINTENANCE: L1 DOOR SLIDE HAS BROKEN BUCKLE. REPLACED SLIDE RAFT ASSEMBLY PER AMM 25-62-44.Jun 6, 2024 · N957XV · Airbus A321253N · Escape SlideSDR AALA202406065299Bottle · low pressureAIRCRAFT WAS NOT GROUNDED: L3 DOOR ACCUMULATOR NEEDS SERVICING. SERVICED L3 DOOR ACCUMULATOR IAW AMM 52-10-00.Jun 5, 2024 · N954XV · Airbus A321253N · Emergency EquipmentSDR AALA202406030115Smoke Detector · false indicationAIRCRAFT WAS NOT GROUNDED: SMOKE LAVATORY ECAM INDICATION. NO SMOKE WAS OBSERVED. ONLY LAVATORY IN USE AT TIME OF INDICATION WAS MIDDLE LAVATORY. MAINTENANCE ACCOMPLISHED TSM 26-17-00-810-804A AND A SATISFACTORY OPERATIONAL TEST WITH NO FAULTS OR MESSAGES NOTEJun 1, 2024 · N950XV · Airbus A321253N · Smoke DetectionSDR AALA202405210032Bottle · low pressureAIRCRAFT WAS NOT GROUNDED: THE AFT R/H PASSENGER DOOR ACCUMULATOR IS LOW NEEDS SERVICING WITH NITROGEN. SERVICED AFT R/H PASSENGER DOOR ACCUMULATOR WITH NITROGEN IAW AMM 52-10-00. LEAK CHECK GOOD.May 19, 2024 · N958XV · Airbus A321253N · Emergency EquipmentSDR AALA202405215563Bottle · low pressureAIRCRAFT WAS NOT GROUNDED: THE AFT L/H PASSENGER DOOR ACCUMULATOR IS LOW NEEDS SERVICING WITH NITROGEN. SERVICED AFT L/H PASSENGER DOOR ACCUMULATOR WITH NITROGEN IAW AMM 52-10-00. LEAK CHECK GOOD.May 19, 2024 · N958XV · Airbus A321253N · Emergency EquipmentSDR AALA202405152036Handle · stuckAIRCRAFT WAS IN BASE MAINTENANCE: R3 EMERGENCY EXIT DOOR INTERNAL HANDLE IS HARD TO OPEN (059-09). REMOVED AND REPLACED ARM LEVERS IN SECTION TRANSVERSE AT R3 EMERGENCY EXIT DOOR IAW N321 AIPC 52-22-11-04, AMM 20-21-11-0201. PERFORMED OPS CHECK GOOD, REFER TO May 14, 2024 · N951XV · Airbus A321253N · Service Doors
Back to Airbus A321-253N