SDR HALA2014091600138Warning Light · false activationAPU START SUCCESSFUL. APU FAULT AFTER INFLIGHT START. TROUBLESHOT IAW TSM 49-62-00. CHECKED LUBRICATION, OIL FILTER AND GENERATOR OIL FILTER DIFFERENTIAL PRESSURE INDICATORS. CHECK OK. PERFORMED APU TEST IAW AMM 49-62 TEST OK. INDICATION NORMAL. UNABLE SDR USAA2014091700001Cvr · inoperativeRETURN TO FIELD. DISTINCT UNPLEASANT ODOR ON CLIMB OUT. THE SMELL WAS METALLIC WITH A METALLIC TASTE IN THEIR MOUTHS. REPLACED THE COCKPIT VOICE RECORDER .SDR USAA2014091100002Lens · brokenSEAT MOUNTED ESCAPE PATH LIGHTING LENS AT SEAT 10G IS BROKEN. R & R ESCAPE PATH LIGHTING ASSEMBLY AT SEAT 10G.SDR HALA2014090900134Pump · failedAPU AFT FUEL PUMP FAULT ECAM DISPLAYED WHEN LEAVING THE ACFT. R & R AFT APU FUEL PUMP IAW AMM 28-22-52. OPS & LEAK CHECKED GOOD.SDR USAA2014090900001Monitor · faultyCABIN ODOR ON TAKEOFF, SUSPECTED ELEC SMELL. ABOUT 12 PEOPLE COMMENTED ON ODOR REPORTED TO OCC. NO SMELL COMING FROM ENGINES OR APU, ISOLATED PACKS NO SMELL. OPERATED ALL GALLEY EQUIPMENT, NO SMELL, NO BREAKERS TRIPPED. OPERATED IFE FOUND MONITOR AT 31C BESDR USAA2014090800003Fitting · leakingFLIGHT 206 WAS FLYING FOR ONE HOUR TWENTY MINUTES WHEN THE CREW ADVISED HE WAS LOSING HYD FLUID FROM THE GREEN SYS. AFTER CONTACTING MAINTENANCE IT WAS AGREED TO RETURN & THE FLIGHT LANDED UNEVENTFULLY BUT NEEDED TOWED TO THE GATE. FOUND LEAKING LINE PRESS FSDR HALA2014090500129Idg · malfunctionedNR 2 GENERATOR FAULT, TROUBLESHOT IAW TSM 24-20-00-810-942-A. SWAPPED GCU'S AND RAN ENGINES, CONDITION SAME. IDG WIRE CHECKED GOOD. R & R NR 2 ENGINE IDG IAW AMM 24-21-51-400-804-A. OPS CHECKED GOOD, NO FAULTS NOTED. OK FOR SERVICE.SDR HALA2014090500128Idg · malfunctionedNR 2 GENERATOR FAULT. TROUBLESHOT IAW TSM 24-20-00-810-942-A, SWAPPED GCU'S AND RAN ENGINES, CONDITION SAME. IDG WIRE CHECKED GOOD. R & R NR 2 ENGINE IDG IAW AMM 24-21-51-400-804-A. OPS CHECK EDGOOD, NO FAULTS NOTED, OK FOR SERVICE.SDR USAA2014090500001Bottle · low pressureCIDS PANEL WARNING TO CHECK 2R DOOR PRESS. PRESS LIGHT NOT ON AT 2R DOOR. SERVICED DOOR ASSIST BOTTLE, OK FOR SERVICE. MSG CLEARED, DOOR ASSIST BOTTLE NOW IN GREEN BAND.SDR HALA2014083100127Pump · contaminatedFUEL ECAM FOR LT PUMP FAULT. TROUBLESHOT IAW TSM 28-21-00-810-852, PURGED LEFT PUMP BOOST PUMP. FOUND DIRT AND WATER WHILE PURGING BOOST PUMP. NOW OPS NORMAL, OK FOR SERVICE.SDR USAA2014090200001Sign · unsecure3R DOOR EXIT LIGHT ABOVE DOOR FELL OFF & IS CRACKED. REPLACED SIGN.SDR USAA2014082900002Cylinder · low pressure2R DOOR ASSIST PRESS LOW. SERVICED AS REQUIRED. LEAK CHECKED GOOD.SDR USAA2014082800015Power Supply · inoperativeEPSU 15WL FAILS TEST WITH BATTERY FAULT. REPLACED EPSU 15WL BATTERY.SDR USAA2014082800012Bottle · low pressureA5 CHECK L4 DOOR ASSIST BOTTLE PRESS FOUND BELOW SERVICEABLE LIMIT IAW JOB CARD 33C80052002. SERVICED L4 DOOR ASSIST BOTTLE PRESS IAW JOB CARD 33C80052002.SDR USAA2014082800011Bottle · low pressureA5 CHECK R1 DOOR ASSIST BOTTLE PRESS FOUND BELOW SERVICEABLE LIMIT IAW JOB CARD 33C80052002. SERVICED R1 DOOR ASSIST BOTTLE PRESS IAW JOB CARD 33C80052002.SDR HALA2014082600120Warning Message · false activationDURING TAKEOFF ROLL, RECEIVED AN ECAM FOR ABNORMAL THRUST, ABNORMAL BLEED CONFIGURATION. PERFORMED TSM 71-00-00-810-941-A. CHECKED OK. OK FOR SERVICE.SDR CA140827003Pump · cracked(CAN) IN CRUISE FLIGHT CREW OBSERVED THE GREEN HYDRAULIC QTY SLOWLY STARTING TO DECREASE. APPROXIMATELY 1.5 HOURS PRIOR TO LANDING LOW LEVEL ADVISOR WAS TRIGGERED. THE CREW CARRIED OUT THE QRH PROCEDURE AND SHUT DOWN THE PUMP TO PREVENT PUMP CAVITATION AND DAMSDR USAA2014082500025Bottle · low pressureA 08 CHECK LOW PRESS ON R2 DOOR ASSIST BOTTLE. SERVICED R2 DOOR ASSIST BOTTLE IAW JOB CARD 33C80052002.SDR USAA2014082500022Bottle · low pressureDURING DAILY CHECK FOUND 2R DOOR ASSIST BOTTLE PRESS LOW. REQUIRES SERVICING. NO MSG ON FAP OR CIDS. SERVICED 2R DOOR TO NOMINAL PRESS.SDR USAA2014082500021Bottle · low pressure2R DOOR ASSIST BOTTLE SHOWS LOW PRESS. SERVICED 2R DOOR ASSIST BOTTLE TO PROPER CHARGE.SDR USAA2014082500007Oven · overheatedEN-ROUTE AFT GALLEY OVEN NR 1 OVERHEAT WARNING LIGHT ILLUMINATED. PULLED OVEN CB 6-11. R & R AFT NR 1 OVEN.SDR USAA2014082200019Bottle · low pressureA5 CHECK R4 DOOR ASSIST BOTTLE HAS LOW PRESS. SERVICED R4 DOOR ASSIST BOTTLE IAW WITH JOB CARD 33C80052002.SDR USAA2014082200018Bottle · low pressureA5 CHECK L1 DOOR ASSIST BOTTLE HAS LOW PRESS. SERVICED L1 DOOR ASSIST BOTTLE IAW WITH JOB CARD 33C80052002.SDR USAA2014082200017Bottle · low pressureA5 CHECK L2 DOOR ASSIST BOTTLE HAS LOW PRESS. SERVICED L2 DOOR ASSIST BOTTLE IAW WITH JOB CARD 33C80052002.SDR USAA2014082200016Bottle · low pressureA5 CHECK R1 DOOR ASSIST BOTTLE HAS LOW PRESS. SERVICED R1 DOOR ASSIST BOTTLE IAW WITH JOB CARD 33C80052002.SDR USAA2014082200007Bottle · low pressureR4 DOOR ASSIST BOTTLE PRESS LOW. SERVICED R4 DOOR ASSIST BOTTLE.SDR USAA2014082200006Bottle · low pressureR1 DOOR ASSIST BOTTLE PRESS LOW. SERVICED R1 DOOR ASSIST BOTTLE.SDR USAA2014082200005Bottle · low pressureL2 DOOR ASSIST BOTTLE PRESS LOW. SERVICED L2 DOOR ASSIST BOTTLE.SDR USAA2014082200004Bottle · low pressureL1 DOOR ASSIST BOTTLE PRESS LOW. SERVICED L1 DOOR ASSIST BOTTLE.SDR USAA2014082200003Bottle · low pressureR2 DOOR ASSIST BOTTLE PRESS LOW. SERVICED R2 DOOR ASSIST BOTTLE.SDR USAA2014082200002Bottle · low pressureL2 DOOR ASSIST BOTTLE PRESS LOW. SERVICED L2 DOOR ASSIST BOTTLE.SDR USAA2014082100007Bottle · low pressureA CHECK 2R DOOR ASSIST BOTTLE PRESS IS LOW. SERVICED 2R DOOR ASSIST BOTTLE IAW JOB CARD 33C80052002.SDR USAA2014082100006Bottle · low pressureA CHECK 2L DOOR ASSIST BOTTLE PRESS IS LOW. SERVICED 2L DOOR ASSIST BOTTLE IAW JOB CARD 33C80052002.SDR USAA2014082100005Bottle · low pressureA CHECK 4L DOOR ASSIST BOTTLE PRESS IS LOW. SERVICED 4L DOOR ASSIST BOTTLE IAW JOB CARD 33C80052002.SDR USAA2014082100004Bottle · low pressureA CHECK 2R DOOR ASSIST BOTTLE PRESS IS LOW. SERVICED 2R DOOR ASSIST BOTTLE IAW JOB CARD 33C80052002.SDR USAA2014082100003Bottle · low pressureA CHECK 2L DOOR ASSIST BOTTLE PRESS IS LOW. SERVICED 2L DOOR ASSIST BOTTLE IAW JOB CARD 33C80052002.SDR USAA2014082100002Bottle · low pressureA CHECK 1R DOOR ASSIST BOTTLE PRESS IS LOW. SERVICED 1R DOOR ASSIST BOTTLE IAW JOB CARD 33C80052002.SDR USAA2014082200001Battery · dischargedAFT RT FLIGHT ATTENDANT EMER FLASHLIGHT INOPERATIVE. REPLACED EMER FLASHLIGHT BATTERY AT AFT RT FLIGHT ATTENDANT STATION. CHECKED OKAY.SDR USAA2014082000001Battery · dischargedEMERGENCY LIGHT TEST CLASS 1 FAULT 15WL, 16WL & 17WL BATTERY. REPLACED BATTERY'S ON EMER POWER SUPPLY UNITS 15WL, 16WL & 17WL.SDR USAA2014081900001Dampener · low pressure3R DOOR AMBER LIGHT SLIDE LOW PRESS. MX SERVICED 3R DOOR DAMPENER.SDR ANCF2014081701Shock Absorber · out of adjustREJECTED TAKEOFF 09L DUE TO EXCESSIVE NLG VIBRATION. IAW TSM 32-20-00-810-801A ITEM 3A THE NLG WHEEL ASSEMBLY WAS CHECKED. THE NLG WHEEL TIRE PRESS WERE ADJUSTED TO 193 PSI. THE NLG LUBRICATION WAS PERFORMED & THE NLG SHOCK ABSORBER WAS ADJUSTED TO CORRECT SDR USAA2014081800003Bottle · low pressureR3 DOOR ASSIST BOTTLE LOW. SERVICED DOOR ASSIST BOTTLE.SDR USAA2014081800002Lens · missingLAVATORY L38 MISSING EMER LIGHT LENS. INSTALLED EMER LIGHT LENS AT LAVATORY L38. OK FOR SERVICE.SDR USAA2014081800001Damper · low pressureDOOR 2R SLIDE PRESS LOW. SERVICED DOOR DAMPER & EMER OPERATION CYLINDER AT DOOR 2R TO NORMAL PRESS.SDR HALA2014081500114Toilet · leakingF/A REPORT LAV G HAS UNSTOPPABLE SEWAGE LEAK, AIR TURN BACK. INSTALLED NEW TOILET ASSY AT LAV G IAW AMM 38-31-41, OPS CHECKED OK. OK FOR SERVICE.SDR USAA2014081500002Switch · faultyROUGHLY AN HOUR BEFORE LANDING, FLIGHT GOT AN ECAM MSG THAT THE GREEN HYD RESERVOIR LEVEL LOW. IAW ECAM PROCEDURE THEY LOST SOME BRAKING, SLOWED FLIGHT CONTROLS, CAT 3 LANDING ABILITY & NOSE WHEEL STEERING. DECLARED AN EMER, OPERATIONS INFORMED THAT FLIGHT WSDR HALA2014081100111Transducer · malfunctionedSENSOR FAULT ECAM UPON ADVANCING THRUST ON T/O. REMOVED SIDE STICK ASSY ON FO'S SIDE IAW AMM 27-92. R & R SIDE STICK TRASDUCER UNIT 4CE2 IAW AMM 27-92. REINSTALLED F/O'S SIDE STICK ASSY IAW AMM 27-92. ALL TEST OPS CHECK GOOD.SDR USAA2014081100016Bottle · low pressureCIDS PANEL MSG, 2R CHECK DOOR PRESS DISPLAYED. SERVICED 2R DOOR ASSIST BOTTLE AS REQUIRED. OK FOR SERVICE.SDR USAA2014080600004Heater · inoperativeGIRT BAR HEATER 24DH AT DOOR 4R INOPERATIVE. R & R GIRT BAR HEATER.SDR USAA2014080600003Heater · inoperativeGIRT BAR HEATER 12DH AT DOOR 2R INOPERATIVE. R & R GIRT BAR HEATER.
Back to Airbus A330-243