SENSOR FAULT ECAM UPON ADVANCING THRUST ON T/O. REMOVED SIDE STICK ASSY ON FO'S SIDE IAW AMM 27-92. R & R SIDE STICK TRASDUCER UNIT 4CE2 IAW AMM 27-92. REINSTALLED F/O'S SIDE STICK ASSY IAW AMM 27-92. ALL TEST OPS CHECK GOOD.