Boeing 717-200
Service difficulty reports · 18,771
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '717200' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '717200' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CA051007001Engine · malfunctionedAC DIVERTED AND LANDED. IN CRUISE, AUTO THROTTLES BEGAN MOVING BACK FORTH AS NR 1 ENG APPARENTLY WAS LOSING PWR, NR 2 ENG WAS INCREASING PWR TO COMPENSATE, A GROWLING NOISE IN NR 1 ENGINE, ENG SURGED 3 TO 5 TIMES, SMELL OF SMOKE WAS NOTICED IN CABIN, OIL PRESSDR AT0500034Engine · unserviceableAT CRUISE, A GROWLING NOISE HEARD ALONG WITH ENGINE SURGE FOLLOWED BY TWO LOUD POPPING NOISES ACCOMPANIED BY A BRIEF SMELL OF SMOKE. SHUT ENGINE DOWN AND DIVERTED. REMOVED AND REPLACED NR 1 ENGINE.SDR AT0500033Lamp · brokenROW 17 EMERGENCY LIGHT INOP. REMOVED & REPLACED EMERGENCY LIGHT BULBS REF AMM 33-51, OPS CHECK GOOD. P/N OFF/ON LP7265-001.SDR AT0500032Lamp · brokenEMERGENCY PATH LIGHT 1FWD, 10, AND 20 INOP. RELAMPED, OPS CHECK NORMAL. REF MM 33-00.SDR MWEA050103Battery Pack · inoperativeBOTH OVERWING EMERGENCY LIGHTS INOPERATIVE. REPLACED OVERWING BATTERY PACK.SDR AT0500031Display · failedNR 4 DU FAILED IN FLIGHT WITH SMOKE IN COCKPIT ONLY. REMOVED AND REPLACED NR 4 DU. DISPLAY TESTS PASSED. ALSO CLEANED REMAINING DU COOLING INLETS. INSPECTED INST COOLING FAN & FILTER, NO DEFECTS FOUND. OK FOR SERVICE. REF 31-43, 31-61. P/N OFF/ON 408217SDR HALA0500905Eec · malfunctionedWHILE CLIMBING OUT AT 5000 FT, WE GO A RT ENGINE FADEC SELECT LIGHT ABNORMAL WAS PERFORMED BUT SOON AFTER EXPERIENCED A MOMENTARY RT ENGINE SHUTDOWN. ENGINE CAME BACK TO NORMAL, RETURNED TO AIRPORT. FOUND FAULT 732167 FOR EEC, 2 REPLACED, NR 2 EEC PERFORMED SDR HALA0500873Eec · failedENGINE RT SYSTEM FAIL MESSAGE ILLUMINATED. REMOVED AND REPLACED EEC, OPS CHECK OK. AIRCRAFT RELEASED FOR SERVICE. (K)SDR AT0500028Display · shortedPAX & F/A REPORTED SMOKE /ELECT ARCHING ASSOCIATED WITH X/M SATELLITE SYSTEM AT SEATS 11/A/C. PULLED SYSTEM BREAKERS SMOKE/ ARCHING CEASED. UNEVENTFUL DIVERT TO RIC. REMOVED AND REPLACED DASDU UNDER SEAT 11 AC.SDR AT0700048Skin · dentedFOUND DENT LEFT SIDE OF AIRCRAFT AT LONGERON 18 - 3 INCHES BY 1 INCH BY .0625 DEEP AT STATION 237. INSTALLED PERMANENT DOUBLER REPAIR AT STA 229 TO STA 264 BETWEEN L-16L TO 18L IAW B717 SRM 51-00-01 FIG 401. MATERIAL AND SIZE USED. DOUBLER 2024T3-.063 X 36SDR AT0500026Power Supply · inoperativeFIRST CLASS SEAT EMERGENCY LIGHTS INOPERATIVE. REMOVED AND REPLACED EMERGENCY LIGHT POWER SUPPLY AND BATTERY PACKS AT STA 312 IAW MM 33-51. OPS CK GOOD.SDR AT0500025Line · crackedLOSS OF HYD PRESSURE AND QUANTITY AFTER TAKE OFF. FOUND CRACKED END ON GROUND SRV RETURN/PRESS LINE. REPAIRED END OF TUBING WITH PERM-A-SWAGE FITTING REF M/M 20-10 SERVICED HYD LEAK AND OPS CK GOOD. RAN NR 2 ENG, OPS CK EDP, OPS CK GOOD.SDR HALA0500801Engine · malfunctionedLT ENGINE PARAMETERS STARTED TO FLUCTUATE APPROX 7000 FT ON CLIMBOUT. WENT FROM CLB1 TO MCT PWR, IGN SYMBOL CAME ON. FMS PAGE CHANGED TO CONFIRM ENG OUT ALL FLUCTUATIONS WERE SMALL AND DID NOT SHUTDOWN ENGINE. ACCOMPLISHED FIM 73-22, TASK 807 EEC, INPUTS FRSDR AT0500030Wire · burnedAFT HANDSET CORD MELTED AND PRODUCED STRONG ELECTRICAL ODOR. REMOVED AND REPLACED AFT F/A HANDSET, OPS CHECKS NORMAL, NO OTHER DISCREPANCIES NOTED, REF AMM 23-41. OK FOR SERVICE.SDR AT0500024Battery Pack · inoperativeEMERGENCY LIGHTS IN AFT ACCESSORY COMPT INOPERATIVE. REPLACED BATTERY PACK IN OVERHEAD FWD OF AFT ACCESSORY COMPT DOOR REF 33-00. NOW CKS OK.SDR AT0500023Battery · inoperativeEMERG LIGHTS AT ROWS 123&10 WILL NOT ILLUMINATE. REMOVED AND REPLACED EMERG LIGHT BATTERY SUPPLY ASSY AND REMOVED AND REPLACED PROXIMITY LIGHT ASSY ROW 10 FWD IN REF TO MM 33-51SDR MWEA050070Skin · dentedDENT IN FUSELAGE SKIN STATION 275 AND LONGERON 18 (CUSP) LEFT HAND SIDE. FABRICATED AND INSTALLED DOUBLER.SDR MWEA050069Stringer · dentedLONGERON 18 LEFT (CUSP) IS DISTORTED AT STATION 275 DO TO DENT IN FUSELAGE SKIN. FABRICATED AND INSTALLED DOUBLER.SDR AT0500022Relay · malfunctionedPAX O2 ALT REL C/B NR L33 POPPED AFTER 1 RESET. REMOVED AND REPLACED RELAY R2-5152 AND C/B B1-870. PERFORMED O2 MASK DROP CHECK PER M/M 35-23, OPS CHECK GOOD.SDR AT0500021Connector · looseSEAT 31D E PATH LIGHTS WILL NOT ILLUMINATE. SECURED LOOSE FLOOR TRACK TO SEAT HARNESS CONNECTOR AS REQUIRED. OPS CHECK GOOD.SDR AT0500020Slide · deployedR1 DOOR SLIDE DEPLOYED BY GROUND PERSONNEL. REMOVED AND REPLACED R-1 DOOR SLIDE.SDR MWEA050059Transceiver · inoperativeAFTER DEPARTURE LOST COMUNICATION ON NR 1 AND NR 2 COMM. REMOVED AND REPLACED NR 1 VHF TRANCEIVER.SDR MWEA050058Wire · unsecureSEAT 13D EMERGENCY EXIT ROW DOOR HAS A WIRE HANGING OUT OF LOWER PANEL. RESECURED WIRE.SDR AT0700035Skin · dentedFUSELAGE DENT AT FS 239L BETWEEN L17 AND L18 MEASURES 6 X 8 X .125 INCH DEEP. INSTALLED PERMANENT REPAIR AT BS 239 BETWEEN LONG 17L AND 18L AS REQUIRED IAW B717 SRM 53-00-01 FIG 201, MATERIAL USED 2024T3.050, 16.25 X 18.5 AND 2024T3.025, 33.5 X 5.75 DOUBLER 2SDR AT0500019Control Unit · inoperativeIN CLIMB RT ENG FIRE IND CAME ON WITH NO LIGHT IN RT FIRE HANDLE. LANDED IN BWI AT 108000 LBS. PERFORMED FIM TASK 26-11, TASK 807-808 ALERT ENGINE RT FIRE. REMOVED AND REPLACED RIGHT ENGINE FDCU IAW B717 AMM 26-11 FAULT TEST OK. (REF 44EB02) NOTED BY MX OVSDR AT0500018Battery Pack · inoperativeROW 1 TO 10 EMERGENCY LIGHTS ARE INOP. REMOVED AND REPLACED SEAT MOUNTED EMERGENCY FLOOR AISLE LIGHT ASSY AT ROW 5. OPS CK GOOD. REMOVED AND REPLACED B5-118 BATTERY PACK.SDR MWEA050052Eec · faultyINFLIGHT CREW HAD THE LEFT ENGINE SYSTEM FAIL ALERT AND THE NR 1 EPR WENT INOPERATIVE. MAINTENANCE FOUND FAULT CODE 732160 AND REMOVED AND REPLACED THE LEFT ENGINE EEC.SDR MWEA050050Skin · lightning strikeLIGHTNING STRIKE AT RIVET ATTACHMENT JUST ABOVE LONGERON 6 LEFT. FABRICATED AND INSTALLED DOUBLER.SDR MWEA050049Skin · lightning strikeLIGHTNING STRIKE AT RIVET ATTACHMENT 3, 6 AND 10 FORWARD OF FRAME STATION 408 LONGERON 8 LEFT, FRAME STATION 541 LONGERON 7 LEFT AND FRAME STATION 560 BELOW LONGERON 5 LEFT. FABRICATED AND INSTALLED DOUBLER.SDR MWEA050048Skin · lightning strikeFUSELAGE SKIN AT STATION 148 BETWEEN LONGERON 14 AND 15 LEFT HAS EVIDENCE OF A LIGHTNING STRIKE. BLENDED DAMAGE.SDR MWEA050047Rivet · lightning strikeONE EACH RIVET AT STATION 64-83 ABOVE LONGERON 18 LEFT HAS EVIDENCE OF A LIGHTNING STRIKE. HEAT DAMAGE HAS BEEN REMOVED AND INSTALLED RIVETS.SDR MWEA050051Computer · faultyIN CLIMBOUT OF MKE OVER BRR NR 2 FCC FAIL WITH ENGINE LEFT AND RIGHT SYSTEMS FAULT AND A STALL WARNING FAULT. REMOVED AND REPLACED BOTH FCC.SDR HALA0500610Eec · faultySELECT L FADEC ON EAD (FOLLOWED SOP). AFTER 2 MIN EPR RETURNED TO NORMAL OPS. A/C RETURNED WHERE AN UNEVENTFUL LANDING WAS MADE. REMOVED AND REPLACED LT ENGINE EEC IAW AMM. OPS CHECK OK. NO FAULTS NOTED. (K)SDR HALA0500597Eec · malfunctionedRT ENGINE AUTO SHUTDOWN DURING THE START SEQUENCE, AFTER IGNITION AND STARTER CUTOUT. NO EXCEEDENCES NOTED. REMOVED AND REPLACED NR 2 ENGINE EEC IAW AMM. RTS TEST PASSED. GROUND RUN OPS CHECK GOOD. (K)SDR AT050016Eec · malfunctionedDURING CLIMBOUT AT CLIMB THRUST AT APPROX 14,000 FEET THE RIGHT ENGINE ROLLED BACK (THROTTLES DID NOT MOVE) EPR & TGT FELL, AUTO-IGNITION CAME ON & ENGINE RECOVERED. NO AUDIBLE INDICATIONS, NO ALERTS, NO FAULTS. THIS REOCCURRED APPROXIMATELY 2 MINUTES LATER.SDR AT0500015Battery Pack · inoperativeEMERGENCY LIGHTS AT BUSINESS SEATS AND FRONT ROW COACH INOPERATIVE. FOUND WRONG LAMPS INSTALLED SEAT ROWS 1-10. RELAMPED EPL ROWS 1-10. REMOVED AND REPLACED EMERGENCY BATTERY ASSEMBLY B5-118. ALSO REPAIRED LOOSE CONNECTION AT ROW 10, EMERGENCY LIGHTS OPS CSDR AT0500017Engine · failedAT FL 290, ENGINE LT SURGE APPEARED ON EAD. LOST OIL PRESSURE ON LEFT ENGINE; LOUD BANG PRECEEDED THESE TWO ALERTS FOLLOWED QRH PROCEDURES AND SHUT DOWN ENGINE. REMOVED AND REPLACED NR 11 ENGINE REF TASK CARD 603, OPS CHECK GOOD OK FOR SERVICE.SDR AT0700018Skin · dentedFUSELAGE SKIN HAS DENT AT FUS STA 237 ABOVE LONG 18L. INSTALLED FLUSH REPAIR TO FUSELAGE SKIN AT FS 237 ABOVE LONGERON 18L DUE TO DENT. REPAIR 21 X 14 X 0.050 INCH, 2024 T3 INSTALLED PER B717 SRM 53-00-01 PG 208 FIG 201.SDR MWEA050044Battery · dischargedCOCKPIT FLASHLIGHT INOPERATIVE. REMOVED AND REPLACED BATTERIES.SDR MWEA060230Control Column · disconnectedRUDDER LIMIT FAULT ON ENGINE AND ALERT DISPLAY AND CONTROL COLUMN DISCONNECTED. PERFORMED FAULT ISLOATION MANUAL TASK OR RETURNED TO SERVICE WORK, LIGHTNING STRIKE OVERSPEED, CONTROL COLUMN DISCONNECTED, RUDDER LIMITER, ADJUSTED AIR DATA INERTIAL REFERENCE UNSDR MWEA050043Skin · lightning strikeLIGHTNING STRIKE DAMAGE TO TAILCONE BOTTOM RIGHT EDGE. NO OTHER INFORMATION AT THIS TIME WAITING FOR FIX.SDR MWEA050042Fmu · inoperativeLEFT ENGINE PARAMETER N1 AND N2 ENGINE PRESSURE RATIO BEGAN FLUCUATING. PERFORMED FAULT REVIEW. FAULTS 732132. INSPECTED AND CHANGED LEFT ENGINE LOW AND HIGH PRESSURE FUEL FILTERS, NO CONTAMINATION. REMOVED AND REPLACED LEFT ENGINE FUEL METERING UNIT.SDR MWEA050038Anti-Ice System · failedCREW REPORTS WINDOW ANTI-ICE FAIL. REMOVED AND REPLACED WINDSHIELD.SDR AT0700036Skin · dentedRT SIDE OF FUSELAGE APPROX 12 INCHES AFT OF THE MIDDLE OF R1 DOOR DAMAGED. DAMAGE IS A DENT 12 INCHES LONG X 7.5 INCHES WIDE AND .150 DEEP. A SCRATCH THAT WAS 9 INCHES LONG X .100 WIDE AND .006 DEEP HAS BEEN BLENDED. INSTALLED FLUSH REPAIR AT STA 218 BETWEESDR AT0700075Attach Fitting · crackedRIGHT LOUVER ATTACH FITTING ON RIGHT SIDE OF TAIL COMPARTMENT CRACKED. INSTALLED DOUBLER REPAIR AT RIGHT HAND LOUVER IAW AIRTRAN T/C 17-5320-2023 FIG 1.SDR AT0700088Fitting · crackedRIGHT LOUVER ATTACH FITTING ON RIGHT SIDE OF TAIL COMPARTMENT CRACKED. INSTALLED DOUBLER REPAIR AT RIGHT LOUVER IAW AIRTRAN T/C 17-5320-2023.SDR MWEA050036Lens · brokenTHE MAIN CABIN DOOR EMERGENCY LENS EXIT SIGN HAS COME OFF THE CEILING ABOVE THE DOOR. REINSTALLED LENS COVER.SDR AT0500014Eec · inoperativeENGINE RIGHT SYSTEM FAIL AND REVERSER RIGHT FAIL IN CLIMB. HAD NO THROTTLE RESPONSE TRIED ALTN FADEC, NO RESPONSE SHUTDOWN ENGINE NECESSARY TO DESCEND AND LAND. REMOVED AND REPLACED NR 2 ENG EEC PER AMM 73-21-01. C/W RTS, RTS GOOD. C/W SPECIAL INSP OF LPC SDR MWEA050029Proximity Sensor · out of toleranceACCESS COMPARTMENT DOOR ANNUNCIATOR ILLUMINATED. INSPECTED DOOR FOUND TARGET AND PROXIMITY SENSOR TO BE OUT OF TOLERANCE DUE TO FAULT. REOPENED, RESEATED AND RESECURED DOOR, ALL WORK DONE, OK FOR SERVICE.SDR AT0500013Actuator · inoperativePUT THE GEAR HANDLE DOWN AND GOT 3 GREEN AND GEAR DOOR OPEN ALERT. FOLLOWED QRH. LANDED WITH GEAR DOORS OPEN. REMOVED AND REPLACED MLG DOOR ACTUATOR IAW MM 32-34. LEAK AND OPS CHECK GOOD.
Back to Boeing 717-200