Boeing 717-200
Service difficulty reports · 18,771
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '717200' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '717200' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR MWEA040160Panel · unsecureCLIMBING THROUGH 10,000FLT. ALTITUDE NO WATER PRESSURE FOR COFFEE, ALSO NO WATER PRESSURE IN EITHER LAVATORY. FOUND WATER SERVICE PANEL OPEN. SECURCURED PANEL, NO DAMAGE FOUND.SDR MWEA040159Warning System · false indicationLEVEL TWO ALERT GENERATOR RIGHT WITH NO VOLTS OR FREQUENCY. -- PERFORMED SATISFACTORY TEST OF SYSTEM. ALL SYSTEMS, OPERATIONS CHECKED GOOD. AIRCRAFT OK FOR SERVICE.SDR AT0400017Switch · inoperative3 GEAR UNSAFE ON EXTENSION OF GEAR. BAD SWITCH (S-189) REPLACED (P/N DT2R-A7) SENSING AND CONTROL MICRO SWITCH.SDR CA040902001Turbine · failed(CAN) ENGINE WAS REMOVED DUE TO TURBINE AND HPC FAILURE. THIS ENGINE IS BEING ROUTED CANADA (MONTREAL) MFG FOR INVESTIGATION AND REPAIR. EVENT: 8/22/04, AIRCRAFT, NR 2 POSITION. WHILE SPOOLING THE ENGINES UP FOR THE TAKOFF ROLL, A LOUD BANG WAS HEARD FROM THESDR AT0700139Skin · dentedDENT LOCATED FS 408 AND RT L16 MEASURES A 1.5 INCH IN DIA BY .045 DEEP, PER SRM 53-00-01 COND 3 MUST BE REPAIRED WITHIN 4500 FLT HOURS. INSTALLED DOUBLER REPAIR ON FUSELAGE SKIN RT BETWEEN STA 414.5 TO 422 AND BETWEEN L-16R TO 18R IAW B717 SRM 53-00-01 FIG 20SDR AT0400016Odor · detectedRETURNED TO ATL AFTER TAKEOFF BECAUSE OF REPORTED SMELL OF SMOKE OR ELECTRICITY EMITTING FROM THE GALLEY 2 AREA. RAN LEFT AND RIGHT ENGINE AND BOTH PACKS, NO DEFECTS NOTED. CHECKED E & E AND CARGO COMPARTMENT REF M/M 49-10, 21-00, 71-00 AND 05-52.SDR MWEA040153Relay · inoperativeEMERGENCY POWER SWITCH OFF ALERT CAME ON. REMOVED AND REPLACED BUS SENSING RELAY.SDR MWEA040152Engine · vibrationRIGHT ENGINE HIGH VIBRATION ALERT. INSPECTED RIGHT ENGINE, NO DEFECTS FOUND. PERFORMED POWER ASSURANCE CHECK, SATISFACTORY. AIRCRAFT OK FOR SERVICE.SDR AT0700053Skin · dentedA/C HAS DENT LOCATED AFT OF L-1 DOOR AT APPROX STA 235, 8 INCHES ABOVE CUSP LINE .5 L X .75 W X .018 DEEP. INSTALLED DOUBLER REPAIR AT AFT OF L-1 DOOR STA 235 AS PER B717 SRM 53-00-01. MATERIAL USED 2024 T3.032, 6.25 X 5.75 INCHES.SDR HALA0400829Engine · fireCREW REPORTED TO TAXI OUT, NR 2 ENGINE WENT TO 997C. ALOHA OBSERVED FLAMES COMING FROM NR 2 EXHAUST. ALSO, ACARS MESSAGE ENGINE SURGE. ENGINE CHANGE IN PROCESS. (M)SDR CA040813002Blade · damaged(CAN) ENGINE 11348 HAD A COMMANDED IFSD AT 33,000 FT WHEN LEFT ENGINE SURGE IN FLT. ENGINE WAS SHUT DOWN AS IT CONTINUE TO SURGE. BOROSCOPE REVEALED SEVERE HPC DAM AGE FROM STAGE 2 TO STAGE 10, WITH BLADES HEAVILY DAMAGED AND MISSING. ENGINE ENROUTE FOR RRC, FSDR AT0400015Engine · surgesLT ENGINE SURGED IN FLIGHT. ENGINE SHUT DOWN AS IT CONTINUED TO SURGE.SDR MWEA040127Transducer · malfunctionedDURING FLIGHT CONTROL CHECK, CIRCUIT BREAKER POPPED AND STICK PUSHER FAIL ANNUNCIATED. REMOVED AND REPLACED FORCE TRANSDUCER.SDR MWAE040126Bypass Valve · openLEFT HYDRAULIC TEMPERATURE HIGH CAME ON. FOUND ELEVATOR BYPASS VALVE OPEN. CLOSED VALVE, OPERATED BOTH HYDRAULIC SYSTEMS WITHOUT DISCREPANCY.SDR MWEA040125Skin · damagedLIGHTNING STRIKE DAMAGE LEFT ELEVATOR LOWER OUTBOARD TRAILING EDGE. FABRICATED AND INSTALLED ELEVATOR STRUCTURAL ASSEMBLY.SDR MWEA040123Skin · bentLOWER CORNER OF PASSENGER DOOR SKIN IS BENT AT EDGE 1.00 INCH X 4.00 INCH. REMOVED DAMAGE, INSTALLED EXTERNAL DOUBLER.SDR MWEA04124Skin · damagedUPPER FORWARD CORNER OF PASSENGER DOOR SKIN EDGE IS BENT 1.00 INCH X 2.00 INCH. REMOVED DAMAGE AND INSTALLED DOUBLER.SDR MWEA040120Thermocouple · illuminatedLEFT ENGINE SYSTEM FAIL ALERT CAME ON. REMOVED AND REPLACED LEFT ENGINE CHANNEL A AND B T-30 THERMOCOUPLES.SDR AT0400014Light · smokeWHEN TESTING EMERGENCY LIGHTS, AISLE PATH LIGHTS STARTED TO SMOKE. TURNED OFF LIGHTS AND SMOKE STOPPED. RELAMPED EMERGENCY EXIT LIGHTS AT 20D, OPS CHECKED GOOD IAW 33-51.SDR AT0700072Skin · damagedLEFT FLAP DAMAGE DUE TO FOD. INSTALLED TWO DOUBLER REPAIR AT LEFT INBOARD AREA IAW AIRTRAN RES 06-05-19. MATERIAL USED 0.063 7075T6. SIZE 7" X 7.5" AND 6" X 8".SDR AT0400013Power Supply · inoperativeFOUND DURING SERVICE CHECK BUSINESS CLASS SEAT ROWS 1, 2 AND 3 EMERGENCY PATH LIGHTS FAILED TO ILLUMINATE. REMOVED AND REPLACED POWER SUPPLY ASSEMBLY B5-118 IAW AMM 33-51-03, OPS CHECK GOOD. BLOWN FUSE INTERNAL.SDR MWEA040106Doubler · damagedFORWARD CARGO DOOR PAN IS DAMAGED AT LOWER AFT CORNER. INSTALLED DOUBLER.SDR MWEA040105Pcdu · inoperativeRECEIVED ELECTRICAL FAULT, CENTER TRANSMITTER SHOWS 29 VOLTS AND ZERO LOAD. REMOVED AND REPLACED POWER CONVERSION AND DISTRIBUTION UNIT.SDR MWEA040104Outflow Valve · inoperativeCABIN PRESSURE MANUAL FAIL. REMOVED AND REPLACED THE CABIN AIR OUTFLOW VALVE ACTUATOR.SDR MWEA040099Warning Light · illuminatedFORWARD GALLEY DOOR LIGHT ILLUMINATED. PERFORMED FIM PROCEDURE 52-40 TASK 806, ADJUSTED AIR GAP. OPERATION CHECKED GOOD.SDR MWEA040098Controller · inoperativeAUXILIARY POWER UNIT QUIT DURING ENGINE START. REMOVED AND REPLACED AUXILIARY DOOR CONTROLLER.SDR MWEA040093Doubler · lightning strikeLEFT ELEVATOR UPPER SKIN OUTBOARD AFT SKIN HAS AN AREA OF LIGHTNING STRIKE DAMAGE. FABRICATED AND INSTALLED DOUBLER.SDR AT0700073Skin · dentedDENT FOUND AT FS 229 AND STRINGER L-18 ON LT SIDE OF FUSELAGE JUST AFT OF L-1 DOOR - 2 INCH WIDE BY 4.35 INCHES LONG MAX DEPTH OF DENT .091. INSTALLED DOUBLER REPAIR AT STA 229 TO STA 245.5 BETWEEN L-16 TO L-18 IAW B717 SRM 53-00-01 REP 6. MATERIAL USED FILLSDR AT0700086Skin · dentedDENT FOUND AT FS 229 AND STRINGER L-18 ON LT SIDE OF FUSELAGE JUST AFT OF L-1 DOOR - 2 INCH WIDE BY 4.35 INCHES LONG MAX DEPTH OF DENT .091. INSTALLED DOUBLER REPAIR AT STA 229 TO STA 245.5 BETWEEN L-16 TO L-18 IAW B717 STM 53-00-01 REPAIR 6. MATERIAL USED FSDR MWEA040083Warning Light · false indicationSPOILER INBOARD FAIL ALERT. PERFORMED FIM 27-60-805/807 SPOILER ELECTRONIC CONTROL UNIT RETURN TO SERVICE, PASSED TEST AND NO FAULTS NOTED. CLEARED SYSTEM, OPERATION CHECKED GOOD.SDR MWEA040082Control Column · inoperativeCREW REPORTED COLUMN DISCONNECT. RECONNECTED CONTROL COLUMN, OPERATIONS CHECK GOOD.SDR MWEA040078Skin · damagedHOLE IN FUSELAGE SKIN MEASURING 12 INCHES X 4 INCHES AT STATION 422 BETWEEN LONGERON 26 LT AND 24 LT. SPLICE IN NEW SECTION OF SKIN.SDR MWEA040074Skin · damagedLOWER SKIN SECTION AT STATION 422 BELOW LONGERON 26 LEFT IS TORN 3 INCHES. REMOVED AND REPLACED DAMAGED SECTION.SDR MWEA040073Longeron · damagedLONGERON 25 LEFT DAMAGED AT STATION 422. SPLICED IN NEW SECTION OF LONGERON.SDR MWEA040072Skin · damagedSCRATCH ON FUSELAGE SKIN AT STATION 484 AND LONGERON 25 LEFT REQUIRES REPAIR. INSTALLED REPAIR DOUBLER.SDR MWEA040070Clip · defectiveTAILCONE WOULD NOT DROP USING AFT ENTRY DOOR EMERGENCY RELEASE MECHANISM. ADJUSTED SPRING CLIPS FOR PIN 12. RETESTED OPERATIONS CHECKED GOOD.SDR AT0400012Wire · brokenEMERGENCY LIGHTS AT ROW 3F INOPERATIVE. RETERMINATED BROKEN WIRE AT SEAT ROW 3 DISCONNECT IAW SWPM 20-31-00. FUNCTIONAL CHECK NORMAL IAW AMM 33-51-00.SDR 2004FA0000392Connector · mismanufacturedMOD 16 INSTALLED BY OEM MISWIRED. THIS IS CAUSING THE OVER TEMP PROTECTION CIRCUIT TO BECOME INOPERATIVE.SDR AT0400011Wire · brokenDURING EMERGENCY LIGHT OPS CHECK, WHILE PERFORMING SERVICE CHECK, SEAT ROW 20 DEF LIGHT FAILS TO LIGHT. REPAIRED WIRING AT SEAT ASSY. PER B717 SWPM 20-30-12 AND SWPM 20-10-13, AND WDM 33-51-14 OPS CHECK NORMAL IAW AMM 33-51-00.SDR AT0400010Power Supply · inoperativeOVERWING EMERGENCY LIGHT WOULD NOT ILLUMINATE. REMOVED AND REPLACED BATTERY SUPPLY REF 717 AMM 33-51-06, OPS CHECK GOOD (IN AFT CARGO COMPARTMENT).SDR AT0400009Power Supply · unserviceableCABIN CEILING EMERGENCY LIGHTS FOR ROWS 1-15 DISCHARGE AND SHUT OFF AFTER APPROXIMATELY 10 SECONDS. REMOVED AND REPLACED EMERGENCY LIGHTS BATTERY POWER SUPPLY R5-227 IAW AMM 33-51-03. OPS CHECK NORMAL IAW MM 33-51-00.SDR AT0400008Light · will not testTAIL COMPARTMENT EMERGENCY LIGHT DID NOT TEST ON A CHECK L2-738. CLEANED LIGHT TERMINALS, OPS CHECK GOOD IAW B717 MM 3353.SDR MWEA040049Doubler · gougedAFT CABIN DOOR PAN IS GOUGED ON LEFT SIDE NEAR FLIGHT ATTENDANT SEAT, BOTTOM SNUBBER. FABRICATED AND INSTALLED REPAIR DOUBLER.SDR AT0700031Structure · ground damageCATERING TRUCK STRUCK AIRCRAFT ON RIGHT SIDE NEAR R-1 DOOR. INSTALLED REPAIR CLASS 3 PAGE 219-226 LONGERON 19R-20R STA 210-200 AS PER B717 SRM 53-00-01 AND RES 04-0289 WO 24177 AND N/R 3052 AVBORNE.SDR 2004FA0000301Coupler · inoperativeOPTO COUPLER (MOD-16) INSTALLED BY MFG IS MISWIRED, CAUSING OVER TEMP PROTECTION CIRCUIT TO BECOME INOPERATIVE.SDR AT0400007Slide · unserviceableL1 DOOR EVACUATION SLIDE PRESSURE INDICATES JUST OUT OF GREEN ARC. REMOVED AND REPLACED L1 DOOR EVACUATION SLIDE PER B717 AMM 25-61-01.SDR MWEA040031Audio Panel · intermittentCAPTAIN'S AUDIO PANEL IS INTERMITTENT. REMOVED AND REPLACED AUDIO CENTRAL PANEL.SDR MWEA040029Generator · false indicationGENERATOR FAILED APU STARTED AND POWER BUSSES NORMAL, STATUS PAGE SHOWS LEVEL TWO ALERTS THAT ARE PRESENT. PERFORMED FIM 24-20-801, NO FAULTS FOUND.SDR MWEA040028Computer · intermittentLOW SPEED HIGH PROTECTION CAME ON TOGETHER AND STICK SHAKER. PERFORMED ADJUSTMENT TEST OF NUMBER 1 FLIGHT CONTROL COMPUTER AND NR 2 FLIGHT CONTROL COMPUTER STALL WARNING SYSTEM BOTH PASSED STALL WARNING CHECK.SDR MWEA040026Valve · malfunctionedANTI-SKID FAIL ALERT ILLUMINATED. REMOVED AND REPLACED ANTI-SKID RETURN VALVE.
Back to Boeing 717-200