What was found
A/C HAS DENT LOCATED AFT OF L-1 DOOR AT APPROX STA 235, 8 INCHES ABOVE CUSP LINE .5 L X .75 W X .018 DEEP. INSTALLED DOUBLER REPAIR AT AFT OF L-1 DOOR STA 235 AS PER B717 SRM 53-00-01. MATERIAL USED 2024 T3.032, 6.25 X 5.75 INCHES.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
A/C HAS DENT LOCATED AFT OF L-1 DOOR AT APPROX STA 235, 8 INCHES ABOVE CUSP LINE .5 L X .75 W X .018 DEEP. INSTALLED DOUBLER REPAIR AT AFT OF L-1 DOOR STA 235 AS PER B717 SRM 53-00-01. MATERIAL USED 2024 T3.032, 6.25 X 5.75 INCHES.