SDR DALA2021032601796Battery Pack · faultedTHE CAT WALK LOWER EMERGENCY LIGHTS ARE INOPERATIVE. MAINTENANCE FOUND THE BATTERY PACK B5-260 TO BE FAULTING. THE EMERGENCY LIGHT BATTERY POWER SUPPLY B5260 WAS REPLACED PER B717 AMM 33-51-03. ALL EMERGENCY LIGHTS NOW CHECK GOOD. THE AIRCRAFT IS OK FOR SERVICSDR DALA2022110207101None · noneDAMAGE TOLERANCE EVALUATION REQUIRED FOR ERA 590529-14. REPAIR APPROVAL IS LIMITED TO 24 MONTHS SERVICE FROM DATE OF APPROVAL ONLY (23 MAR 2023). ADDITIONAL ENGINEERING AUTHORIZATION (ER/A REVISION) IS REQUIRED FOR CONTINUED SERVICE BEYOND THIS LIMIT. NOTE TO SDR DALA2021032401733Hinge · excess playTHE LT O/B FLAP HINGE HAS EXCESSIVE PLAY AT HINGE BOLT. DEFERRED FOR SDR REPORTING. NRC 331: REPAIRED PER PRI 590529-14 REV 0,1,2,3,&4 AND ER/A 590529-14 REV ORIG. (LP #1761231)SDR DALA2021032301719Cover · missingA FLAP COVER ON LEFT WING (CIRCLER 2" DIAMETER COVER) ON UNDER SIDE IS MISSING LOCATED NEAR FUSELAGE BY GEAR BAY. MAINTENANCE INSTALLED A NEW COVER. (LP #7576961)SDR DALA2021032301674Sign · dislodgedTHE EXIT SIGN AT RO 19 IS DISLODGED. MAINTENANCE SECURED THE EXIT SIGN. (LP #7446516)SDR DALA2021032301673Ring · detachedTHE R1 SLIDE PACK MANUAL DEPLOYMENT RING IS NOT ATTACHED TO THE CABLE. MAINTENANCE REPLACED THE R-1 DOOR SLIDE REF ROUTINE TASK CARD 2561-9005. (LP #1760202)SDR DALA2021032201659Strut · damagedTHE LT MLG FIXED STRUT, OB FITTING HAS TOOLING DAMAGE. NRC 006-0003:3211-4003/010 00024: REWORKED AREA PER B717 CMM/OHM 57-40-1 PAGE 611.005 MATERIAL REMOVED TREATED AND PAINTED BLENDED AREA.SDR DALA2021031801529Former · corrodedFORMER AT FS 889 CORRODED AT BL0. PER NRC 001-0291:2550-2003/018 00336 TASK COMPLETE. REPLACE FORMER PER DWG #9923486 AND REF B717 SRM 53-20- 07-2R PROCEDURE 3. (LP #1757932)SDR DALA2021031801528Door Frame · corrodedCORROSION AT MULTIPLE SPOTS AFT CARGO DOOR CUT OUT. (MARKED) PER NRC 00173 001-0371:5230-2002/002, MAINTENANCE APPLIED TOP COAT OF POLY. TASK COMPLETE PER B717 SRM 53-20-15-2R-7. (LP #1757922)SDR DALA2021031801530Battery Pack · no testTHE EMERGENCY LIGHTS WOULD NOT TEST FROM F/A SWITCH. MAINTENANCE FOUND THE OVERWING BATTERY PACK LOW AND REPLACED IT. THE EMERGENCY LIGHTS NOW CHECK GOOD FROM BOTH THE F/A AND COCKPIT POSITIONS. (LP #7577565)SDR DALA2021031201419Power Supply · inoperativeBOTH LEFT & RIGHT EXTERIOR EMERGENCY OVERWING LIGHTS ARE INOPERATIVE. MAINTENANCE REPLACED THE OVERWING EMEGRENCY EVACUATION LIGHT BATTERY POWER SUPPLY PER B717 AMM 33-51. OPERATIONAL CHECK WAS GOOD. (LP #7577552)SDR DALA2021030801297Frame · corrodedCORROSION ON AFT SIDE OF FRAME AT AFT CARGO BIN AFT BULKHEAD STA 1022. MARKED. NRC 037-0022:5310-2014/002 00282 REPAIRED REF B717 SRM 53-20-07-2R. (LP #1748759)SDR DALA2021030801296Floorbeam · crackedREF NRC 131. CRACK FOUND EXTENDING THROUGH MULTIPLE ATTACH FASTENERS ON FLOOR BEAM STA 737. LOCATED RT SIDE OF A/C JUST I/B OF THE OVERWING EXIT FUSELAGE FRAMES. MARKED. NRC 131. MAINTENANCE REPLACED FLOOR BEAM PER DWG #5940863 & INSTALL FLOOR PANELS PER B717 SDR HALA2021030400025Bayonet · out of adjustEMER EQ - DURING OVERNIGHT FOUND MAIN ENTRY DOOR COULD NOT CLOSE FROM OUTSIDE HANDLE. PUSH PULLGAUGE SHOWS 120LBS TO CLOSE FROM OUTSIDE HANDLE AND 80LBS TO CLOSE INSIDE HANDLE. ADJUSTED BAYONET OPERATING ROD PER AMM 52-11-01-820-811 PRESSURIZATION AND OP CHESDR DALA202208205282Door · unknownPD: SUMMARY: DOOR HAD SEVERAL CRACKED AND WORN AREAS, 21 NON-ROUTINE CARDS TOTAL. SEE CARDS FOR DETAILS. SDR DUE TO SRM REPAIRS USED. 52-30-02, / CA: REPAIRED UNIT. THE WORK SPECIFIED IN BLOCK(S) 11/12 ACCOMPLISHED WITHREFERENCE TO OEM CMM 52-30-1, REV. 36 WITSDR HALA2021031200031Rib · crackedCRACK - RIGHT SIDE UNDERWING BARREL KEEL AREA (INSIDE) RIB CRACKED OTBD SIDE STA. 674 // REPAIR FORMER PER E105-B10214-PERM 1/25/21 MECH 13377 INSP 4884SDR HALA2021031200030Former · crackedCRACK - RH MLG DOOR FORMER P/N 9923450-504 CRACKED STA 750.2729 (M) // INSTALLED REPLACEMENT MLG DOOR FORMER P/N 9923450-504 IAW DWG# 5910783.SDR HALA2021031200029Former · crackedCRACK - RH MLG DOOR FORMER P/N 9923450-502 CRACKED UNDER REPAIR FILLER STA 745.027 (M) // INSTALLED REPLACEMENT MLG DOOR FORMER P/N 9923450-502 AT STA 745.027 IAW DWG# 5910783.SDR DALA2021030101128Skin · crackedCRACK DETECTED ON OPEN HOLE BY HFEC ROUTINE CARD 5530-01048-02, STEP 14, VERT STAB L/E SKIN AND FRONT SPAR CAP. CRACK INDICATION IS FIRST HOLE GOING UP R/H SIDE SKIN SPLICE L/E ZFS 52.267. MAINTENANCE REMOVED VOR #1 RH / LH AND VOR #2 RH / LH PER B717 AMM 34-3SDR HALA2021030100023Battery Pack · inoperativeEMER EQ - OVERWING EMERGENCY LIGHTS DO NOT ILLUMINTAE WITH EMER LT SWITCH ON // REMOVED AND REPLACED OVERWING EMER. EVAC BATTERY POWER SUPPLY PER AMM 33-51-06. OPS CHECK GOOD. OK FOR SERVICE.SDR HALA2021030100022Battery Pack · inoperativeEMER EQ - CATWALK EMERGENCY EXIT FLOOR LIGHTS INOP. // REMOVED & REPLACED EMERGENCY BATTERY PER AMM 33-51-03, OPS CHECK GOODSDR DALA2021022501095Slide · no testTHE TAIL CONE SLIDE FAILED THE DEPLOYMENT TEST. THE TAIL CONE SLIDE WAS DEPLOYED FOR SAMPLING. THE SLIDE DEPLOYMENT FAILED. MAINTENANCE REPLACED THE SLIDE ON W/C 2561-9006. (LP 1739712)SDR DALA2021022501093Power Supply · inoperativeON THE SERVICE CHECK, MAINTENANCE FOUND THE OVER WING WALL EXIT LIGHT TO BE INOPERATIVE AT ROW 20. MAINTENANCE REPLACED THE POWER SUPPLY LOCATED AT B5-119. THE EMERGENCY LIGHTS NOW OPERATE NORMALLY REF B717 AMM 33-51. (LP 7596098)SDR DALA2021081104601Roller · wornPD: WORN/LOOSE, OUTBD ROLLER FITTING AT ROLLER. WORN, INBD FWD ATTACH BEARING. ELONGATED HOLES, SLIDER ON INBD ROD. WORN, INBD ROD. ELONGATED, INBD FITTING AT UP STOP ATTACHMENT. BULGING, LOWER SKIN AT TRAILING EDGE 23" FROM INBD (SDR). / CA: REPAIRED UNIT. THSDR DALA2021022501094Lens · missingTHE EMERGENCY EXIT COVER DIFFUSER LENS IS MISSING AT 1C. MAINTENANCE INSTALLED A NEW EMERGENCY LIGHT COVER FOR THE FORWARD CABIN. OPERATIONAL CHECK WAS GOOD. (LP 1737515)SDR DALA2021022200992Battery Pack · inoperativeTHE OVERWING EMERGENCY EXIT LIGHTS ARE INOPERATIVE. MAINTENANCE REPLACED THE OVERWING EMERGENCY LIGHTS BATTERY PER B717 AMM 33-51. THE OPERATIONAL CHECK IS NOW GOOD. (LP #7543697)SDR DALA2021031001367Stringer · corrodedCORROSION ON STRINGER 30 FROM STA 908-974. MARKED. MAINTENANCE REPLACED STRINGER SECTION PER B717 SRM 53-20-05-2R PROCEDURE 1. (LP #1734931)SDR DALA2021040101922Trunnion · corrodedRT MLG TRUNNION FITTING ATTACH LUG FOR FIXED SIDE STRUT AFT FACE PITTED AND CORRODED. NRC 005-0001:08-5740-9- 0052/002 00009: REPAIRED PER PRI 590053-14 REV 0, 1, AND 2 AND ER/A 590053-14 REV ORIGINAL. (LP #1733182)SDR DALA2021021800933Door Frame · corrodedIN THE AFT CARGO COMPARTMENT THERE IS CORROSION IN MULTIPLE LOCATIONS OF THE C-2 DOOR LOWER JAMB AREA. MAINTENANCE REPLACED THE PAN PER B717 SRM 53-20-15-2R-7 ON NON-ROUTINE CARD 104 DURING C2 MTC VISIT.SDR DALA2021021800932Switch · inoperativeTHE EMERGENCY LIGHT SWITCH AT THE ATTENDANT PANEL IS INOPERATIVE. LIGHTS WILL NOT TURN ON WHEN SWITCHED TO ARM (ON). TROUBLE SHOT PER B717 SDS 33-51-00-003 & WDM 33-51-11 AND SUSPECT B5-125 BATTERY PACK. REPLACED THE OVERWING EMERGENCY EVACUATION BATTERY PASDR DALA2021021600834Ballast · inoperativeTHE EMERGENCY LIGHT SIGNS BELOW THE OVERWING EXIT AT ALL FOUR LOCATIONS ARE INOPERATIVE. MAINTENANCE REPLACED THE BATTERY PACK AND BALLAST B5-119 PER B717 AMM 33-51. THE EMERGENCY LIGHTS AT THE OVER WING POSITION NOW OPERATE NORMALLY. (LP #7682718)SDR DALA2021021600833Battery · missingFOUND CARGO EMERGENCY EXTERIOR LIGHTS POWER SUPPLY BATTERY MISSING. REPLACED BATTERY PER B717 AMM 33-51-03. OPERATIONAL CHECK WAS GOOD. OK FOR SERVICE. (LP #7614440)SDR DALA2021021800935None · noneSUPPLEMENTAL INFORMATION - MAINTENANCE COMPLIED WITH ER/A 590042-14 REV ORIG, SEC 1. TIME LIMITED REPAIR. SHIP 9547 - WHILE TAXIING IN PIT AND TRANSITIONING FROM TAXIWAY TO RUNWAY, THE AIRCRAFT EXITED THE HARD SURFACE. THE NOSE GEAR IS OFF OF THE TAXIWAY ANDSDR DALA2021021600835Lens · missingTHE EMERGENCY LIGHT IN THE AFT TAIL COMPARTMENT IS MISSING THE LENS. MAINTENANCE INSTALLED THE LENS ON THE EMERGENCY VENTRAL LIGHT PER B717 AMM 33-51. OPERATIONAL CHECK WAS GOOD. (LP #7614434)SDR DALA2021040101921Trunnion · gougedLMLG TRUNNION FITTING FIXED SIDE BRACE ATTACH LUG BORE HAS STRAIGHT LINE GOUGE FROM FRONT TO BACK AT BOTTOM OF BORE. NRC 006-0001:08-5740-9- 0051/005 00020 REWORKED FITTING IAW B717 OHM 57-40-1, PRI 590055-14, AND ER/A 590055-14 REV ORIGINAL. (LP #1729599)SDR DALA2021021600832Rib · corrodedCORROSION AT STA 927 BOTTOM OF RIB FROM LONGERONS 29R TO 29L. MARKED IN RED REF N/R 351. TRANSFERRED FROM NRC 217. REPAIRED REF B717 SRM 53-20-07-2R. (LP #1729895)SDR DALA2021021200817Slide · no testTHE L1 DOOR SLIDE FAILED THE DEPLOYMENT TEST FORECAST #95-0525-0111 DUE TO THE LANYARD NOT ATTACHED TO GIRT BAR. PN- D29982-225 SN-2678 MFR DATE- 11/09. MAINTENANCE REPLACED THE SLIDE PER W/C 2561-9001. (LP #1728645)SDR DALA2021021000771Sign · detachedTHE EXIT ROW SIGN ON THE AIRCRAFT LEFT IS DETACHED. MAINTENANCE REATTACHED THE SIGN. OPERATIONAL CHECK IS GOOD. (LP #7581138)SDR DALA2021031001366Door Frame · corrodedTHE AFT CARGO LOWER DOOR JAMB IS CORRODED IN NUMEROUS PLACES - MARKED. MAINTENANCE REPAIRED REF B717 SRM 53-20-15-2R PROCEDURE 7. (LP #1725722)SDR DALA2021020800703Battery Pack · inoperativeTHE TAILCONE SLIDE EMERGENCY LIGHTS WERE FOUND TO BE INOPERATIVE. MAINTENACE REPLACED THE EMERGENCY LIGHTS BATTERY, B5-116, PER B717 AMM 33-51. (LP #7593826)SDR DALA2021020200623Hinge · wornLEFT WING. SEALANT MISSING/CRACKED WITH ATTACH HARDWARE RUSTY. OUTBOARD WING FLAP HINGE CONNECTION POINT. -MARKED- REPAIRED WORN FLAP HINGE PER PRI 589529-14 REV 1 AND PER ER/A 589529-14. (LP #1720421 )SDR DALA2021020100579Structure · corrodedCORROSION INSIDE LIGHTENING HOLE AT C2 DOOR OPENING STA 960. SEE NR 048-0008:5331-2001/006 00172: REPAIRED REF ER/A 589573-14 REV O. PRI AND ER/A MATCH CLOSING REQUIREMENTS RII: INSPECTOR 00466532. (LP #1720023)SDR DALA2021020100578Nut Plate · corrodedCORROSION AT C2 CARGO DOOR THRESHOLD ATTACH POINTS. BLIND NUT LOCATIONS. SEE NR 048-0008:5331-2001/003 00169: REPAIRED REF B717 SRM 53-20-15-2R PROCEDURE 7. (LP #1719805)SDR DALA2021020100577Skin · corrodedBULGE FOUND IN FUSELAGE SKIN BENEATH AFT CARGO COMPARTMENT JUST AFT OF Y STATION 1022.091 AND AT LONGERON R29- MARKED. COMPLIED WITH PRI 589616-14 REV O-2, REPAIRED REF ER/A 589616-14 REV B. SEE NRC 34. (LP #1718582)SDR DALA2022010700124Skin · corrodedDTA REQUIRED FOR ER/A 589616-14 REV B / FUSELAGE / SKIN / STA 1022 / L-29R / SKIN BULGE. DTE REQUIRED FOR ER/A 589616-14 REV B. REPAIR APPROVAL IS LIMITED TO 12 MONTHS ONLY. ADDITIONAL ENGINEERING AUTHORIZATION (ER/A REVISION) IS REQUIRED FOR CONTINUED SERVICESDR DALA2021012900547Spar Cap · crackedONE EACH FASTENER HOLE WITH A BHEC CRACK INDICATION ON RT VERTICAL STABILIZER LEADING EDGE FRONT SPAR CAP FORWARD FLANGE. CRACK IS IN FIRST FASTENER HOLE BELOW ZFS=52.267, MARKED. REFERENCE: AA 5530-01048, AD 2018-10-08 STEP 16B. COMPLIED WITH PRI 589482-14SDR DALA2021012800523Wire · shortedTHE AIRCRAFT WAS RETURNED TO THE GATE DUE TO THE LEFT AFT BOOST PUMP CIRCUIT BREAKER TRIPPING WITH REPORTED SMOKE AND ODOR. CORRECTIVE ACTION: MAINTENANCE FOUND R5-6001 CONNECTOR WIRES SHORTED. R5-6001 WAS REPLACED, PER SWPM 20-31-15. BONDING CHECK WAS GOODSDR HALA2021012700012Line · leakingATO-ATO/BTB: HYD L QTY LO ALERT ON T/O ROLL. INSTALLED NR 1 EDP HYD LOW PRESSURE SWITCH LINE, PER AMM 20-10-13-911-801 AND AMM 29-34-01-000-801. PERFORMED IDLE ENGINE NR 1 RUN LEAK TEST, PER AMM 29-00-00-863-808. NO LEAKS NOTED. HYD PRESS OK. A/C OK TO COSDR DALA2021012500462Shear Tie · corrodedCORROSION ON FUSELAGE FRAME AND SKIN CLIP AT STA 1002 LONGERON 28L. REPAIRED FRAME AND SKIN CLIP AT STA 1002, PER B717 SRM 53-20-07-2R ON NRC 186.SDR DALA2024081508168Skin · damaged-AD- LIGHTNING STRIKE DAMAGE TO THE UPPER FWD CORNER OF THE RH #19 WINDOW (RHS STA 579-598). SECTION I: TIME-LIMITED REPAIR ACCOMPLISHMENT PER ER/A 554700-14 REV ORIG. REQUIRED PRIOR TO DEPARTURE FROM EWR. PERMANENT REPAIR ACCOMPLISHMENT PER THIS ER/A REQUIRED
Back to Boeing 717-200