Boeing 727-223
Service difficulty reports · 5,313
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '727223' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '727223' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA960615Light · defectiveDFW - DURING OVERNIGHT CHECK, EMERGENCY LIGHT AT FORWARD GALLEY DOOR INOPERATIVE. REPLACED EMERGENCY LIGHT AT FORWARD GALLEY DOOR. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR 96FDEA00809Floor Beam · corrodedMAIN CARGO STA 344 FLOOR BEAM UPPER CHORD CORRODED WL 208 FROM RBL 23 TO LBL 65. REMOVED DAMAGED SECTION OF UPPER CHORD. INSTALLED NEW UPPER CHORD SECTION, RBL 23 TO LBL 65, PER STANDARD REPAIR DRAWING NR SR 27-53-007, DATED 03-15-94.SDR AALA960611Accessory Unit · defectiveDFW - FLT 1176 - EN ROUTE CUN/DFW - DURING CRUISE, LEFT MAIN LANDING GEAR WARNING LIGHT ILLUMINATED. ALL GEAR DOOR WARNING LIGHTS REMAINED OUT. NO OTHER ABNORMAL INDICATIONS AND AIRCRAFT PROCEEDED TO DFW AND LANDED WITHOUT INCIDENT. REPLACED LANDING GEAR ACSDR AALA960723Carriage Journal · corrodedATL - DURING CONTRACT MAINTENANCE AT DALA FOR HEAVY C-CHECK, THE OUTBOARD CARRIAGE LARGE JOURNAL OF THE LT INBOARD FLAP WAS FOUND CORRODED. MAINTENANCE MACHINED THE OUTER DIAMETER DOWN TO 2.957 INCH AND THE INNER DIAMETER OUT TO 2.010 INCH ON THE TAPERED SECTSDR AALA960599Light · inopMIA - DURING OVERNIGHT CHECK, EMERGENCY FLOOR LIGHTS IN MAIN CABIN INOPERATIVE. CORRECTED REVERSE POLARITY CONDITION AT EMERGENCY FLOOR LIGHT STRIP BY PAX SEAT ROW 29. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA960585Skin · corrodedTUL - FOUND CORROSION ON SKIN BUTT JOINT AFT SIDE FRAME 680, STRINGER 28L TO 28R. REMOVED CORROSION PER SRM CHAP 51-10-6. INSTALLED DOUBLER IAW SRM 53-30-3 P14D. DOUBLER MANUFACTURED FROM .07 INCH 2024-T3. (M)SDR AALA960584Stringer · corrodedTUL - REMOVED CORRODED STRINGER AND INSTALLED NEW STRINGER AND DOUBLERS PER 53-10-3. (M)SDR AALA960722Skin · damagedATL - DURING CONTRACT MAINTENANCE AT DALA, THE UPPER FORWARD CORNER OF THE C-2 DOOR OPENING HAS HAD DAMAGE REMOVED FROM THE OUTER LAYER OF SKIN. THE RESULTING CUT-OUT IS 1.5 INCHES BY .75 INCH IN THE OUTER LAYER OF SKIN. ACCOMPLISHED REPAIRS PER DL ERA 30343SDR CKSA96029Connector · failedKHUF - FLT 73729 - AT CRUISE, ENGINE FIRE WARNING BELL CAME ON VERY WEAK WITHOUT ANY FIRE WARNING LIGHTS. SILENCED THE BELL AND TESTED FIRE WARNING SYSTEM. TESTED OK, BUT WHEN ATTEMPTED RE-TEST, NR 2 FIRE LIGHT WOULD NOT TEST. AFTER SEVERAL ATTEMPTS, NR 2 FSDR AALA960724Wing Chord · crackedATL - DURING CONTRACT MAINTENANCE AT DALA FOR HEAVY C-CHECK, CRACKS WERE DISCOVERED IN THE VERTICAL FLANGE OF THE LBL AND RBL 70.5 WING CHORD AT FS 760.95. REPAIRS WERE ACCOMPLISHED PER SB 727-57-0112, REV B. ACFT TT: 39,457 HRS. ACFT TOTAL CYCLES: 21,587SDR AALA960520Skin · corrodedATL - DURING CONTRACT MAINTENANCE AT DALA FOR HEAVY C-CHECK. CORROSION DAMAGE WAS FOUND ON THE LOWER WING SKIN CENTER SECTION BETWEEN S-3C AND S-4C ABOVE THE LT PLENUM CHAMBER. CORROSION WAS CLEANED AND A REPAIR SIMILAR TO SRM 57-30-3, FIGURE 10, WAS INSTALLSDR AALA960519Frame · loose bushingsATL - DURING CONTRACT MAINTENANCE AT DALA FOR HEAVY C-CHECK. FUSELAGE OPENING FRAME AT FS 784 RIGHT, HAS LOOSE BUSHINGS IN LOCATIONS PREVIOUSLY INSTALLED PER AAL ESO 1523. NEW BUSHINGS WERE INSTALLED PER DL ERA 303303-14AD. ACFT TT, 40,899 HRS. ACFT TC, 21SDR AALA960513Stringer · crackedTUL - FOUND .3125 INCH CRACK IN SUPPORT STRINGER BETWEEN VERTICAL BEAMS, STATION 1183 RBL 36 WL 270. INSTALLED NEW STRINGER AT RBL 36 WL 270 STATION 1183. (M)SDR AALA960721Stringer · corrodedATL - DURING CONTRACT MAINTENANCE AT DALA, FOUND STR 29L WITH SEVERAL AREAS OF CORROSION ON THE OUTBOARD SKIN ATTACH FLANGE. THE DAMAGE WAS LOCATED AT FS 950C TO FS 1000. ACCOMPLISHED REPAIRS PER DL ERA 303390. ACFT TT: 39,457 HRS. ACFT TOTAL CYCLES: 21,SDR AALA960507Frame · crackedTUL - FOUND CRACK ON FRAME AT STATION 420 IN E/E COMPT. INSTALLED DOUBLER PER SRM 51-40-3. (M)SDR AALA960506Angle · crackedTUL - CRACK IN CHORD ANGLE AT FASTENER HOLE BS 804.5, STRINGER 14R. STOP DRILLED CRACKS PER SRM 51-10-1, INSTALLED DOUBLER PER SRM 51-40-3. (M)SDR AALA960505Angle · crackedTUL - FOUND CRACK IN CHORD ANGLE AT FASTENER HOLE BS 804.5, STRINGER 14L. STOP DRILLED CRACK PER SRM 51-10-1, INSTALLED DOUBLER PER SRM 51-40-3. (M)SDR AALA960504Seat Track · crackedTUL - STATION 458 TO 460, RIGHT INBOARD SEAT TRACK HAS CRACK AND CORRSION INSIDE CHANNEL FOR FEET LOCK DOWNS. INSTALLED NEW SEAT TRACK FROM STAITON 440 TO 480 AS PER SRM 53-10-5. (M)SDR AALA960517Door Frame · crackedATL - DURING CONTRACT MAINTENANCE AT DALA FOR HEAVY C-CHECK. MAINTENANCE FOUND A CRACK IN THE DOOR FRAME OF THE E/E COMPARTMENT. THE CRACK WAS 1 INCH LONG ON THE RT SIDE AT THE FASTENER HOLE AFT AND ABOVE OF THE LATCH PIN. MTC ALSO FOUND A 1 INCH CRACK IN TSDR AALA960516Fitting · corrodedATL - DURING CONTRACT MAINTENANCE AT DALA FOR HEAVY C-CHECK. C/W AA ROUTINE CARD NR 4189, THE BORE OF THE TENSION TIE BOLT FITTING ON THE OUTBOARD FORWARD RIGHT SIDE OF THE BS 1183 TORQUE BOX STRINGER 3A WAS FOUND CORRODED. THE CORROSION WAS REMOVED BY REAMISDR 96ZZZX2968Wheel · vibrationKHUF - FLT 73304 - ABORTED TAKEOFF AS A RESULT OF SEVERE VIBRATION EMANATING FROM NOSE WHEEL AREA. VIBRATION BEGAN AT APPROXIMATELY 90 KNOTS AND CONTINUED TO INCREASE WITH AIRSPEEDS. ABORTED AT 110 KNOTS. REMOVED AND REPLACED LEFT NOSE WHEEL. TAXI CHECKED SDR EISA96038Skin · crackedSEVERAL CRACKS ON RIGHT SIDE, UPPER S-DUCT. CUT OUT CRACKED SECTION OF S-DUCT. FABRICATED AND INSTALLED DOUBLER WET PER SRM 54-10-3. (M)SDR AALA960478Stringer · corrodedFOUND CORROSION IN STRINGER 27 RT FROM STATION 615 TO STATION 620. REPAIRED STRINGER 27 RT STATION 615 TO STATION 620 PER SRM 53-10-3, FIG 1. (M)SDR AALA960477Skin · wornTUL - UPPER FWD CORNER OF CARGO DOOR OPENING WORN. REPORTED PER ESO 11697, DATED 2-28-96. (M)SDR AALA960476Skin · corrodedFOUND CORROSION ON STRINGER 29L AND SKIN FWD OF 950E AFT CARGO FROM 950D-950E. REMOVED CORROSION FROM SKIN AND STRINGER 29L AT 950D-950E NDT DETERMINED THICKNESS OF SKIN TO BE BELOW SRM LIMITS, TREATED PRIMED AREA DOUBLER TRIPLER INSTALLED PER ECO11697. (M)SDR AALA960475Skin · corrodedTUL - CORROSION LOWER WING SKIN EXTENSION OUTBOARD OF NR 4 SLAT TRACK. REPAIRED PER B727 AARD 57-30-00-2 PG 1-3. (M)SDR AALA960474Blkhd Beam · crackedFOUND VERTICAL BEAM CRACKED AT STATION 1183 RBL 36, BOTH SIDES APPROX 30 INCHES ABOVE FLOOR LINE. REPAIRED IAW BOEING 727 SB NR 727-53-0192. (M)SDR AALA960473Skin · corrodedTUL - FOUND CORROSION INSIDE FUSELAGE SKIN FWD CARGO BILGE. REMOVED CORROSION INSIDE SKIN AND BLENDED OUT SRM 51-10-6 DAMAGED AREA NOT CUT OUT PER ESO 11697 DATED 1/24/96 2024-T3 .063 DOUBLER INSTALLED OUTSIDE SKIN SRM 53-30-3. (M)SDR AALA960472Web · corrodedFOUND CORROSION FORWARD CARGO DOOR WEB LANDING AT FWD AND AFT ENDS. REMOVED CORRODED WEB BOTH ENDS AT FWD CARGO DOOR MANUFACTURED NEW WEBS 7075-T6 .071 AND CHORD ANGLES TREATED AND PRIMED AND INSTALLED PER SRM 51-10-1. (M)SDR AALA960471Stringer · corrodedTUL - FOUND CORROSION IN STRINGER SPLICE STRINGER 28L, STATION 680. INSTALLED STRINGER REPAIR STATION 680, STRINGER 28L IAW SRM 53-10-3. (M)SDR AALA960470Stringer · corrodedFOUND CORROSION ON STRINGER 27R STATION 680-706. CUT OUT CORRODED AREA OF STRINGER, FABRICATED AND INSTALLED SPLICE PLACE PER SRM 51-10-1. (M)SDR AALA960469Skin · crackedFOUND SKIN HAS CRACK AND CORROSION AT STRINGER 27R, STATION 695. CUT OUT CORROSION ON SKIN FROM STATION 695-680 ALONG STRINGER 27R. INSTALLED DOUBLER ON SKIN FROM STATION 680-710 PER SRM 53-30-3. (M)SDR AALA960468Stringer · corrodedFOUND CORROSION ON STRINGER 29RT, STATION 992 TO 102. REMOVED CORROSION AND INSTALLED REPAIR DOUBLER PER SRM 53-10-3 PGS 11A THROUGH 11E. (M)SDR AALA960467Intercostal · corrodedFOUND CORROSION ON INBOARD SIDE OF INTERCOSTAL STRINGER 28R, STATION 950F AND 970. REMOVED AND REPLACED INTERCOSTAL STRINGER 28R, STATION 950F-970. (M)SDR AALA960466Skin · corrodedTUL - FOUND STATION 950F TO 970 SKIN IS CORRODED ON OUTBOARD SIDE OF STRINGER 28R. REMOVED (BLENDED) CORROSION FROM SKIN 950F-970. INSTALLED DOUBLER AND TRIPLER IN AREA OF CORROSION AND SPLICED IN 2 SECTIONS OF STRINGER REPAIRS IAW ES11697, DTD 3-15-96. (M)SDR AALA960465Stringer · corrodedFOUND STATION 950F TO 970 STRINGER 28R IS CORRODED. REPLACED CORRODED SECTION OF STRINGER REF ESO 11697, DTD 3-15-96. (M)SDR AALA960464Skin · corrodedFOUND CORROSION ON STRINGER 27R AND FUSELAGE SKIN AT STATION 680-685. CUT OUT DAMAGED AREA AND INSTALLED REPAIR DOUBLER AND STRINGER PER SRM 53-30-3 PG 3C. (M)SDR AALA960463Stringer · corrodedFOUND CORROSION IN STRINGER SPLICE 28R, STATION 680. REPAIRED STRINGER 28R AT STATION 680, IAW SRM 53-10-3. (M)SDR AALA960462Stringer · corrodedFOUND CORROSION ON STRINGER 27L, FS 690. CUT OUT DAMAGED AREA INSTALLED DOUBLER REF 53-10-3. (M)SDR AALA960461Skin · corrodedFOUND SKIN CORROSION BEYOND LIMITS ON FUSELAGE. CUT OUT CORRODED AREA AND INSTALLED DOUBLER PER SRM 53-30-3 FIG 1, PG 1-4. (M)SDR AALA960460Frame · corrodedFOUND CORROSION ON 1148 FRAME IN AFT CARGO BILGE. REPAIRED PER SRM 53-10-4 FIG 12. (M)SDR AALA9604331Wire · failedMIA - DURING OVERNIGHT CHECK, FOUND THE EMERGENCY EXIT FLOOR PATH LIGHTS IN FIRST CLASS SECTION INOPERATIVE. REPAIRED SPLICE IN EMERGENCY EXIT FLOOR PATH LIGHTING WIRING. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR EISA96037Web · corrodedLEFT SIDE DOG HOUSE, STATION 328 WEB BULGED. REMOVED CORROSION IAW SRM 51-10-3, FABRICATED DOUBLER REPAIR AND INSTALLED REPAIR WET IAW DWG 25363-5320. (M)SDR AALA960429Wire · failedDFW - DURING OVERNIGHT CHECK, FOUND THE EMERGENCY EXIT FLOOR PATH LIGHTS IN THE ENTIRE CABIN INOPERATIVE. REPAIRED EMERGENCY EXIT FLOOR PATH LIGHTING WIRING. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA960423Connector · looseDFW - DURING OVERNIGHT CHECK, FOUND THE EMERGENCY EXIT FLOOR PATH LIGHTS AT ROWS 26 AND 27 INOPERATIVE. RECONNECTED LOOSE CONNECTOR AT EMERGENCY EXIT FLOOR PATH LIGHT TRACK STRIP. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR EISA96039Duct · separationNR 1 ENGINE FIRE WARNING AT POWER. REPAIRED DAMAGED WIRING AND REPLACED FIRE WALL SENSOR PERFORMED HARDNESS TEST ON ENGINE MOUNTS, REPLACED ALL ENGINE MOUNT VIBRATION ISOLATIONS. REPLACED BURNED NYLON SEALS AND REPLACED ENG COWL DUE TO HEAT DAMAGE. (M)SDR AALA960403Connector · brokenDFW - DURING OVERNIGHT CHECK, EMERGENCY FLOOR LIGHTS IN FIRST CLASS CABIN INOPERATIVE. REPLACED BROKEN EMERGENCY FLOOR LIGHT CONNECTOR IN FIRST CLASS CABIN. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA960388Sensor · defectiveDFW - FLT NR 1089 - EN ROUTE PHL/DFW DURING CRUISE AT FL 310, RIGHT MAIN LANDING GEAR RED WARNING LIGHT ILLUMINATED WITH GEAR HANDLE IN OFF POSITION. CYCLED LANDING GEAR HANDLE TO UP HAD NO EFFECT. AFTER APPROXIMATELY 10 MINUTES, LIGHT EXTINGUISHED AND REMAISDR EISA96032Stiffener · corrodedSECOND STIFFENER AFT OF STATION 294.5 IN NOSE GEAR WELL CORRODED. FABRICATED NEW PART PER SRM 51-20-1, HEAT TREATED PER BAC 5602 AND INSTALLED PER SRM 51-30-2. (M)SDR CKSA96025Accessory Unit · failedKHUF - RIGHT MAIN GEAR UNSAFE LIGHT ILLUMINATED INTERMITTENTLY IN FLIGHT AND ON GROUND. NOSE GEAR UNSAFE LIGHT DOES NOT ILLUMINATE DURING RETRACTION. MASTER DIM AND MASTER TEST SECTION NR 3 LIGHTS INOP. REMOVED AND REPLACED LANDING GEAR ACCESSORY UNIT, SYST
Back to Boeing 727-223