What was found
ATL - DURING CONTRACT MAINTENANCE AT DALA FOR HEAVY C-CHECK. MAINTENANCE FOUND A CRACK IN THE DOOR FRAME OF THE E/E COMPARTMENT. THE CRACK WAS 1 INCH LONG ON THE RT SIDE AT THE FASTENER HOLE AFT AND ABOVE OF THE LATCH PIN. MTC ALSO FOUND A 1 INCH CRACK IN THE LOWER RADIUS OF THE TRANSVERSE BEAM. REPAIRS WERE ACCOMPLISHED IAW SB 727-52-94, REV 2, REF: DL ERA 303317-14AD. ACFT TT: 40,899 HRS. ACFT TC, 21,258. (X)