Boeing 727-223

Service difficulty reports · 5,313

Newest first. General aviation reporting is voluntary.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE aircraft_model_key = '727223'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR EISA20010134Structure · corrodedFOUND CORROSION AT FWD LT CORNER NLG TUNNEL BOX AT STA 294.5 LBL 14. REMOVED DAMAGED SECTION AND INSTALLED REPAIR IAW EO 01-294 REV A.Dec 1, 2001 · N6815 · Boeing 727223 · Fuselage Miscellaneous StructureSDR AALA20012063Connector · damagedLAX - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT LIGHT INOPERATIVE. REPAIRED EMERGENCY EXIT LIGHT SPLICE AT CONNECTOR. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)Nov 22, 2001 · N887AA · Boeing 727223 · Emergency LightingSDR GAIA01316OPLight · defectiveDURING ROUTINE MAINTENANCE AT DFW, IT WAS DISCOVERED THAT THE L1 EMERGENCY EXIT LIGHT WAS DIM. MAINTENANCE REPLACED THE EMERGENCY EXIT LIGHT. OPERATIONALLY CHECKED GOOD. THE AIRCRAFT WAS RETURNED TO SERVICE. (M)Nov 19, 2001 · N6831 · Boeing 727223 · Emergency LightingSDR AALA20012032Light · looseMIA - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT LIGHT AT L1 LOOSE. SECURED EMERGENCY EXIT LIGHT AT L1. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)Nov 11, 2001 · N874AA · Boeing 727223 · Emergency LightingSDR AALA20012028Light · inoperativeDFW - DURING OVERNIGHT MAINTENANCE FORWARD SECTION OF EMERGENCY EXIT ESCAPE PATH LIGHTS INOPERATIVE. REPLACED EMERGENCY EXIT ESCAPE PATH LIGHT STRIP IN FORWARD SECTION. SYSTEM GROUND CHECK NORMAL OPERATION. (M)Nov 8, 2001 · N889AA · Boeing 727223 · Emergency LightingSDR AALA20012017Light · inoperativeDFW - DURING OVERNIGHT MAINTENANCE, AFT AIRSTAIR EMERGENCY EXIT LIGHT INOPERATIVE. REPLACED AFT AIRSTAIR EMERGENCY EXIT LIGHT. SYSTEM GROUND CHECK NORMAL OPERATION. (M)Nov 6, 2001 · N867AA · Boeing 727223 · Emergency LightingSDR 2002F00058Pitot Line · contaminatedON REPOSITION FLIGHT DUE TO IMPENDING HURRICANE ON TAKEOFF ROLL. NO CAPTAINS AIR SPEED INDICATION FLUSHED SYSTEM PER MM 34-11-0 PAGE 209 AND PERFORMED OPS CHECK PER MM 34-11-0. OPS CHECK OK. (M)Nov 4, 2001 · N707AA · Boeing 727223 · Pitot/Static SystemSDR 2002F00057Pitot Line · contaminatedON REPOSITION FLIGHT DUE TO IMPENDING HURRICANE ON TAKEOFF ROLL. NO CAPTAINS AIR SPEED INDICATION FLUSHED SYSTEM PER MM 34-11-0 PAGE 209 AND PERFORMED OPS CHECK PER MM 34-11-0. OPS CHECK OK. (M)Nov 4, 2001 · N707AA · Boeing 727223 · Pitot/Static SystemSDR AALA20011956Light · inoperativeDFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT LIGHT AT ROW 6 THROUGH 8 INOPERATIVE. REPAIRED EMERGENCY EXIT LIGHT SPLICE AT ROW 6 THROUGH 8. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)Oct 23, 2001 · N881AA · Boeing 727223 · Emergency LightingSDR AALA20011960Light · inoperativeMIA - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT LIGHT AT AFT AIRSTAIRS INOPERATIVE. CLEANED EMERGENCY EXIT LIGHT SOCKET AT AFT AIRSTAIRS. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)Oct 17, 2001 · N887AA · Boeing 727223 · Emergency LightingSDR AALA20011938Stringer Clip · corrodedTUL - FOUND CORRODED STRINGER CLIP, FS 1007-1010. INSTALLED NEW STRINGER CLIP PER ESO 11697. (M)Oct 17, 2001 · N864AA · Boeing 727223 · Fuselage Miscellaneous StructureSDR EISA20010129Light · inoperativeFOUND FWD ENTRY DOOR EMERGENCY EXIT LIGHT INOP. REMOVED AND REPLACED FWD EMERGENCY EXIT LIGHT ASSY IAW B727 MM 33, OPS CHECK GOOD.Oct 16, 2001 · N6839 · Boeing 727223 · Emergency LightingSDR EISA20010127Throttle Cable · disconnectedEN ROUTE NR 3 ENGINE WENT TO MAX POWER. RETARDING THROTTLE HAD NO EFFECT. SHUT DOWN ENGINE. AFTER 20 MINUTES, MOVED START LEVER TO IDLE FOR 3 MINUTES TO PURGE FUEL CONTROL. FOUND NR 3 THROTTLE LINKAGE DISCONNECTED. INSTALLED BOLT AND COTTER KEY, INSPECTEDOct 16, 2001 · N6819 · Boeing 727223 · Power LeverSDR AALA20011937Stringer · corrodedTUL - FOUND STRINGER CORRODED STATION 682-691 26R. REMOVED CORRODED STRINGER REPLACED PER ECO11697. (M)Oct 12, 2001 · N864AA · Boeing 727223 · Fuselage Main, Longeron/StringerSDR AALA20011936Sill · corrodedTUL - FOUND CORROSION BETWEEN UPPER AND LOWER SILL PLATES LOWER FORWARD CORNER OF AFT CARGO DOOR CUTOUT. REPAIRED IAW ESO 11697. (M)Oct 12, 2001 · N864AA · Boeing 727223 · Fuselage Miscellaneous StructureSDR AALA20011902Intercostal · corrodedTUL - FOUND CORROSION ON LOWER END OF INTERCOSTAL O/B OF STRINGER 28L. REMOVED INTERCOSTAL, INSTALLED NEW INTERCOSTAL. REMOVED CORRODED SKIN BENEATH INTERCOSTAL, INSTALLED TRIPLER REPAIR PER SRM 53-30-3 INTERCOSTAL REMOVAL AND INSTALLATION PER SRM 51-10-1. Oct 11, 2001 · N864AA · Boeing 727223 · Fuselage Miscellaneous StructureSDR AALA20011910Intercostal · corrodedTUL - FOUND CORROSION ON LOWER FLANGE, FS 950F. INSTALLED INTERCOSTAL AT STRINGER 28R, STATION 950F PER 51-10-1. (M)Oct 11, 2001 · N864AA · Boeing 727223 · Fuselage Miscellaneous StructureSDR EISA20010125Door · out of adjF/E PANEL MAIN CARGO DOOR WARNING LIGHT ILLUMINATE, PRESSURIZATION NORMAL, ALT FL310 PSID 8.0. MAIN CARGO DOOR PANEL, DOOR WARNING LIGHT, VENT DOOR OPEN, AND MAIN CARGO DOOR NOT CLOSED. ADJUSTED MAIN CARGO DOOR, DOOR CLOSED, AND LATCH CLOSED SWITCHES AND OPSOct 11, 2001 · N6813 · Boeing 727223 · Cargo/Baggage DoorsSDR GAI2001F00000Wire · dirtyAFTER TAKE OFF, THE FLIGHT CREW DISCOVERED THAT THE OUTBOARD FLAPS WERE STUCK AT THE 2 DEGREE POSITION. AN EMERGENCY WAS DECLARED AND THE AIRCRAFT RETURNED TO AIRPORT. THE AIRCRAFT MADE AN UNEVENTFUL LANDING. RESET ASYMMETRY CIRCUIT AND CLEANED CANNON PLUG Oct 11, 2001 · N6806 · Boeing 727223 · Trailing Edge Flap Control SystemSDR AALA20011911Channel · corrodedTUL - FOUND CORROSION ON INBOARD SIDE OF HAT CHANNEL AT STATION 1163 APPROX. REPLACED HAT CHANNEL AND INSTALLED DOUBLER PER SRM 51-40-2. (M)Oct 10, 2001 · N864AA · Boeing 727223 · Fuselage Miscellaneous StructureSDR AALA20011845Wire · damagedDFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT LIGHT AT ROW 15-20 INOPERATIVE. REPAIRED EMERGENCY EXIT LIGHT WIRE. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)Oct 6, 2001 · N872AA · Boeing 727223 · Light System WiringSDR AALA20011905Floorbeam · corrodedTUL - FOUND CORROSION ON TOP OF FLOORBEAM STATION 400 OUTBOARD OF OUTBOARD SEAT TRACK AND AT SCREW HOLE. REMOVED CORROSION TREATED AND PRIMED WITHIN LIMITS PER ECO 11697. (M)Oct 5, 2001 · N864AA · Boeing 727223 · Fuselage Main, Floor BeamSDR AALA20011900Splice · crackedTUL - FOUND STRINGER 27R SPLICE CRACKED AND CORRODED AT STATION 685. REMOVED CRACKED SPLICE AND REMOVED CORROSION FROM STRINGER AT STATION 675 AND 685. ALODINED AND PRIMED AREA. REPLACED SPLICE PER SRM 51-10-6. (M)Oct 5, 2001 · N864AA · Boeing 727223 · Fuselage Miscellaneous StructureSDR AALA20011908Bracket · corrodedTUL - FOUND LEFT PRIMARY HEAT EXCHANGER PLENUM ATTACH BRACKET CORRODED, FS 922. REMOVED ANGLE AND INSTALLED NEW ANGLE PER 51-40-3. (M)Oct 5, 2001 · N864AA · Boeing 727223 · Fuselage Miscellaneous StructureSDR AALA20011909Angle · corrodedTUL - FOUND FORWARD GALLEY DOOR SILL DRAINS HAVE CORROSION ON CREASE ANGLE STATION 409 TO STATION 410 AND STATION 373 TO STATION 375. REMOVED DRAIN FITTINGS AND CREASE ANGLE. INSTALLED NEW CREASE ANGLE AND REINSTALLED DRAIN FITTINGS PER SRM 51-40-1. (M)Oct 5, 2001 · N864AA · Boeing 727223 · Fuselage Miscellaneous StructureSDR EISA20010124Switch · inoperativeDURING CLIMB, RED MCD LIGHT ALONG WITH AMBER VENT DOOR NOT CLOSED ILLUM. ALONG WITH UNSCHEDULED CLIMB IN CABIN ALT. ACC. AERONAUTICAL MCD WARNING ILLUM. IN FLT. AFTER RAPID DEPRESS. CHECKLIST COMPLETED LAND AT NEAREST SUITABLE AIRPORT.CORRECTIVE ACTION:DUPLICAOct 5, 2001 · N6813 · Boeing 727223 · Door Warning SystemSDR CA011018005Control Cable · failed(CAN) NOSE GEAR WHEEL WELL DOORS LOWER CABLE REPLACED IN ACCORDANCE WITH MAINTENANCE MANUAL. GEAR SWING CARRIED OUT AND CHECKED SERVICEABLE.Oct 4, 2001 · Boeing 727223 · Landing Gear Door Retract SectionSDR AALA20011903Skin · corrodedTUL - FOUND CORROSION ON WING CENTER SKIN ABOVE LEFT PRIMARY HEAT EXCHANGER PLENUM STATION 900 LBL 28. INSTALLED DOUBLER PER SRM 57-30-3. (M)Oct 4, 2001 · N864AA · Boeing 727223 · Wing, Plate/SkinSDR AALA20011904Skin · corrodedTUL - FOUND CORROSION CENTER WING SKIN ABOVE RIGHT PRIMARY HEAT EXCHANGER PLENUM STATION 903 RBL 30. REMOVED CORROSION AND INSTALLED REPAIRED DOUBLER PER SRM 57-30-3 FIG 10. (M)Oct 4, 2001 · N864AA · Boeing 727223 · Wing, Plate/SkinSDR AALA20011907Floor Support · corrodedTUL - FOUND FLOOR SUPPORT JUST INSIDE OF FORWARD GALLEY DOOR CUTOUT IS CORRODED FROM BS 362-420. INSTALLED NEW Z-ANGLE AT FORWARD GALLEY DOOR STATION 352-420 PER 51-40-3. (M)Oct 4, 2001 · N864AA · Boeing 727223 · Fuselage Miscellaneous StructureSDR AALA20011828Battery Pack · dischargedDTW - DURING OVERNIGHT MAINTENANCE, EMERGENCY FLOOR PATH LIGHTING INOPERATIVE. REPLACED BATTERY PACK. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)Sep 28, 2001 · N843AA · Boeing 727223 · Emergency LightingSDR AALA20011838Stringer · corrodedTUL - FOUND CORROSION ON STRINGER TIE STATION 1133 ON INBOARD SIDE OF STRINGER 27L. CUT OUT CORRODED SECTION OF STRINGER STATION 1116 TO 1134. INSTALLED NEW STRINGER SECTION AND REPAIR SPLICE PER SRM 53-10-3. (M)Sep 27, 2001 · N875AA · Boeing 727223 · Fuselage Main, Longeron/StringerSDR AALA20011840Shear Tie · corrodedTUL - FOUND CORROSION ON SHEAR TIE STATION 680 BETWEEN STRINGER 28R AND STR 29R. REMOVED CORRODED SHEAR TIE FLANGE AND INSTALLED REPAIR ANGLE PER SRM 53-10-4 FIG 14. (M)Sep 26, 2001 · N875AA · Boeing 727223 · Fuselage Main, StructureSDR AALA20011839Shear Tie · corrodedTUL - FOUND CORROSION ON SHEAR TIE STATION 700 BETWEEN STRINGER 28R AND 29R. TRIMMED OFF DAMAGED SECTION OF SHEAR TIE AND INSTALLED REPAIR AT SKIN ATTACHMENT AS PER SRM 53-10-4 FIG 15 SHEET 3. (M)Sep 26, 2001 · N875AA · Boeing 727223 · Fuselage Main, StructureSDR AALA20011813Frame · corrodedTUL - FOUND CORROSION ON FRAME STATION 370 BELOW FLOOR LINE RBL 65. CUT OUT DAMAGED AREA AND INSTALLED DOUBLER PER ESO 11697 ATED 9-14-2001. (M)Sep 19, 2001 · N876AA · Boeing 727223 · Fuselage Main, FrameSDR AALA20011812Floorbeam · corrodedTUL - FOUND SATION 1130 TOP OF FLOORBEAM BETWEEN LEFT SEAT TRACKS CORRODED. FABRICATED AND INSTALLED REPAIR STRAP PER ESO 11697 DATED 9-17-01. (M)Sep 18, 2001 · N876AA · Boeing 727223 · Fuselage Main, Floor BeamSDR AALA20011814Splice · corrodedTUL - FOUND LIGHT CORROSION ON END OF STRINGER SPLICE, STATION 686, STRINGER 28R. REMOVED AND REPLACED WITH NEW STRINGER SPLICE PER SRM 51-10-1. (M)Sep 12, 2001 · N876AA · Boeing 727223 · Fuselage Miscellaneous StructureSDR AALA20011778Light · inoperativeTUL - FOUND PORTABLE EMERGENCY EXIT LIGHT OVER COCKPIT DOOR INOPERATIVE. INSTALLED SERVICEABLE LIGHT ASSEMBLY LIG5197 IPC 33-50-00-20. INSTALLED PER MM 33-50-101-2, OPS CHECK OK. WORK ACCOMPLISHED ON E-58 3862640. (M)Sep 12, 2001 · N860AA · Boeing 727223 · Emergency LightingSDR AALA20011779Light · inoperativeTUL - FOUND VENTRAL AIRSTAIRS AFT OVERHEAD EMERGENCY LIGHT INOPERATIVE. (M)Sep 11, 2001 · N879AA · Boeing 727223 · Emergency LightingSDR GAIA01306OPLight · inoperativeDURING MAINTENANCE AT TOL, IT WAS DISCOVERED THAT THE L1 DOOR EMERGENCY EXIT LIGHT WAS INOPERATIVE. REMOVED AND REPLACED THE EMERGENCY EXIT LIGHT. THE SYSTEM OPERATIONALLY CHECKED GOOD. THE AIRCRAFT WAS RETURNED TO SERVICE. (M)Sep 8, 2001 · N6816 · Boeing 727223 · Emergency LightingSDR AALA20011741Beam · corrodedTUL - FOUND CORROSION ON RIGHT HORIZONTAL STAB UPPER T/E BEAM INBOARD OF NR 7 ELEV HINGE. INSTALLED DOUBLER PER ESO 11697. (M)Sep 6, 2001 · N884AA · Boeing 727223 · Horizontal Stabilizer StructureSDR AALA20011742Skin · dentedTUL - FOUND DENT WITH CREASE IN FUSELAGE SKIN. CUT OUT DAMAGE AND INSTALLED FILLER AND DOUBLER PER 53-30-3 FIG 3 PAGE 13 AND 53-30-3 PART 1 DETAIL 1. (M)Sep 5, 2001 · N884AA · Boeing 727223 · Fuselage Main, Plate/SkinSDR AALA10011743SkinTUL - FOUND BUBBLE IN FUSELAGE SKIN STATION 1013 ABOVE STRINGER 28 LEFT. CUT AND REMOVED DAMAGED SECTION OF SKIN, FABRICATED AND INSTALLED REPAIR DOUBLER IAW SRM 53-30-3A. (M)Aug 31, 2001 · N884AA · Boeing 727223 · Fuselage Main, Plate/SkinSDR GAIA01305OPActuator · failedFLT - 1843 - PHL-FWA - ON APPROACH TO FWA, THE FLIGHT CREW NOTICED THAT THE NR 8 SLAT DID NOT INDICATE EXTENDED WHEN THE FLAP HANDLE WAS MOVED FROM 2 DEGREES TO THE 5 DEGREE POSITION. AN EMERGENCY WAS DECLARED AND A UNEVENTFUL LANDING WAS MADE AT FWA. REMOVEAug 31, 2001 · N6827 · Boeing 727223 · Leading Edge Slat ActuatorSDR AALA20011715Light · inoperativeDFW - DURING OVERNIGHT MAINTENANCE, OVERHEAD EMERGENCY LIGHT AT ROW 9 INOPERATIVE. REPLACED LIGHT ASSEMBLY. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)Aug 30, 2001 · N861AA · Boeing 727223 · Emergency LightingSDR AALA20011714Battery Pack · dischargedDFW - DURING OVERNIGHT MAINTENANCE, FORWARD GALLEY CEILING EMERGENCY EXIT LIGHT INOPERATIVE. REPLACED BATTERY PACK. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)Aug 30, 2001 · N861AA · Boeing 727223 · Emergency LightingSDR AALA20011710Light · inoperativeDFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT PATH LIGHTING INOPERATIVE. REPLACED LIGHT STRIP. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)Aug 29, 2001 · N867AA · Boeing 727223 · Emergency LightingSDR AALA20011711Battery Pack · dischargedDFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT PATH LIGHTING DIM THROUGHOUT COACH. REPLACED FORWARD AND AFT BATTERY PACKS. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)Aug 29, 2001 · N849AA · Boeing 727223 · Emergency LightingSDR AALA20011712Battery Pack · dischargedDFW - DURING OVERNIGHT MAINTENANCE, L1 AND R1 EMERGENCY EXIT SLIDE LIGHT INOPERATIVE. REPLACED BATTERY PACK. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)Aug 29, 2001 · N872AA · Boeing 727223 · Emergency LightingSDR EISA20010117Hydraulic System · lowAFTER TAKEOFF WITH GEAR UP AND FLAPS AT 2 DEGREES HYD SYS A QTY DROPPED TO 1.6 GALLONS. SERVICED A-SYSTEM HYDRAULICS, RAN ALL FLT CONTROLS, SYS OPS OK AND A-SYS QTY IND FALL.Aug 28, 2001 · N312NE · Boeing 727223 · Hydraulic System, Main
Back to Boeing 727-223