Boeing 727-223
Service difficulty reports · 5,313
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '727223' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '727223' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA20011699Battery Pack · dischargedDFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY LIGHT IN AFT CABIN INOPERATIVE. REPLACED BATTERY PACK. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA20011695Battery Pack · dischargedDFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY AFT STAIRWELL LIGHTS INOPERATIVE. REPLACED BATTERY PACK. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA20011719Stringer · corrodedTUL - FOUND STRINGER 24L DENTED AT STATION 460. CUT AND REMOVED DAMAGED SECTION OF STRINGER. SPLICED IN NEW SECTION OF STRINGER PER SRM 53-10-3. (M)SDR AALA20011720Skin · gougedTUL - FOUND GOUGE IN SKIN STATION 460 STRINGER 24L. CUTOUT DAMAGED AREA OF SKIN AND INSTALLED DOUBLER REPAIR PER SRM 53-30-3. (M)SDR AALA20011700Light · inoperativeTUL - FOUND VENTRAL STAIRS EMERGENCY LIGHT INOPERATIVE. INSTALLED SERVICEABLE VENTRAL STAIRS EMERGENCY LIGHT PER MM 33-50-061-4 PAGE 403, REPAIRED ON E-58 4012889. (M)SDR EISA20010113Hydraulic Line · looseON HEADING TO JOIN THE FINAL APPROACH COURSE TO 31R AT JFK, SYSTEM 1 LOW LEVEL LIGHT ILLUMINATED. OBSERVED SYSTEM A HYDRAULIC QUANTITY DECREASING RAPIDLY PAST 2 TO LESS THAN 1 GALLON. REQUESTED A VECTOR OFF THE FINAL APPROACH COURSE TO COMPLETE THE SYSTEM A SDR AALA20011718Web · crackedTUL - FOUND VERTICAL WEB OF RIGHT LOWER TORQUE BOX CRACKED APPROX STATION 1233 UPPER LIGHTENING HOLE. INSTALLED DOUBLER OVER DAMAGED AREA (AFTER ROUTING OUT CRACK) PER SRM 51-40-2. (M)SDR AALA20011677Light · inoperativeDFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT PATH LIGHTING IN AFT STAIRWELL INOPERATIVE. REPLACED AFT STAIRWELL LIGHT ASSEMBLY. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA20011667Web · corrodedTUL - FOUND CORROSION ALONG LINE STATION 1140 FROM APPROX 24 INCHES RBL TO 36 INCHES RBL SEVERAL AREAS. CUTOUT DAMAGED AREA AND INSTALLED WEB REPAIR PER SRM 51-40-2 PAGES 1-6. (M)SDR AALA20011654Battery Pack · dischargedDFW - DURING OVERNIGHT MAINTENANCE EMERGENCY EXIT PATH LIGHTING AT R1 AND L1 DOOR INOPERATIVE. REPLACED BATTERY PACKS. SYSTEM GROUND CHECK NORMAL OPERATION. (M)SDR AALA20011652Light · inoperativeDFW - DURING OVERNIGHT MAINTENANCE, AFT STAIR EMERGENCY LIGHT INOPERATIVE. REPLACED LIGHT ASSEMBLY. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA20011653Connector · looseMIA - DURING OVERNIGHT MAINTENANCE, EMERGENCY FLOOR PATH LIGHTING IS INTERMITTENT. RESECURED LOOSE CONNECTOR. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA20011666Rib · crackedTUL - FOUND STATION 760 RIB CHORD CRACKED BEHIND 760 RIGHT FRAME. STOP DRILLED CRACK. INSTALLED REPAIR DOUBLERS 760 RBL 70.5 IAW SB 727-57-0112 AS EPR CARD 4258 PAGE 2 ITEM 9. (M)SDR AALA20011665SkinTUL - FOUND BULGE ABOVE LEFT RAM AIR DOOR MIDWAY ALONG LEFT EDGE OF CUTOUT. REMOVED CORROSION AND INSTALLED .080 17-7 PH DOUBLER PER ESO 11697 DATED 8/15/2001. (M)SDR AALA20011663Skin · corrodedTUL - FOUND CORROSION UPPER RIGHT HORIZONTAL STAB SKIN T/E BEAM 4 HINGE IN FROM STAB TIP AT ABOUT STAB STATION 115. REPAIRED CORROSION AREA AS PER ESO 11697 DATED 8-16-2001. (M)SDR AALA20011662Beam · corrodedTUL - FOUND CORROSION UPPER RIGHT HORIZONTAL T/E BEAM 3RD ELEVATOR HINGE IN FROM TIP. REPAIRED CORROSION AREA AS PER ESO 11697, 8-16-2001. (M)SDR AALA20011664Skin · corrodedTUL - FOUND LOWER WING LEADING EDGE SKIN CORRODED AFT OF INBOARD FUEL CAP. INSTALLED DOUBLER PER ESO NR 11697 DATED 8-13-2001. (M)SDR GAIA01296STFrame · damagedDURING ROUTINE MAINTENANCE AT DFW, IT WAS DISCOVERED THAT THE BS 600 FRAME WAS DAMAGED AT STRINGER S17R. REPAIRED IAW BOEING 727 SRM 51-40-3, FIGURE 1 PAGE 3. THE AIRCRAFT WAS RETURNED TO SERVICE. (M)SDR GAIA01297OPLight · inoperativeDURING ROUTINE MAINTENANCE AT DFW, IT WAS DISCOVERED THAT THE L1 DOOR POSITION EMERGENCY EXIT LIGHT WAS INOPERATIVE. REMOVED AND REPLACED THE L1 DOOR POSITION EMERGENCY EXIT LIGHT ASSEMBLY. OPERATIONALLY CHECKS GOOD. THE AIRCRAFT WAS RETURNED TO SERVICE. (SDR GAIA01295OPWarning System · malfunctionedFLT 202 - SEA-GEG - DURING CRUISE, THE NR 1 ENGINE STRUT OVERHEAT LIGHT ILLUMINATED. THE CREW ACCOMPLISHED ABNORMAL PROCEDURES AND THE LIGHT EXTINGUISHED. AIRCRAFT MADE AN UNEVENTFUL LANDING IN GEG. INSPECTED AIR DUCTS FOR LEAKS IN PYLON AREA. NO LEAKS WERSDR AALA20011610Bear Strap · crackedTUL - FOUND LOW FREQUENCY EDDY CURRENT INDICATES CRACK PROGRESSING FROM FASTENER ON AFT LWR FORWARD GALLEY DOOR CUTOUT. TRIMMED OUT DAMAGE AT BARE STRAP AND INSTALLED DOUBLER/TRIPLER PER SB 727-53-188 FIG 3. (M)SDR GAIA01293OPShutoff Valve · stuckFLT 2015 - BIL-DEN - DURING CLIMB-OUT FROM BIL, THE FLIGHT CREW NOTICED THE NR 1 ENGINE OIL TEMPERATURE SLOWLY RISING. A EMERGENCY WAS DECLARED AND THE ENGINE WAS SHUTDOWN. THE AIRCRAFT RETURNED TO BIL AND AN UNEVENTFUL LANDING WAS MADE. INVESTIGATION REVEASDR AALA20011573Battery Pack · dischargedTUL - FOUND LEFT AND RIGHT FORWARD DOOR SLIDE LIGHTS FAILED 10 MINUTE CHECK. REPLACED FORWARD DOOR SLIDE LIGHT BATTERY PACK. (M)SDR AALA20011574Battery Pack · dischargedTUL - FOUND RIGHT FORWARD AND AFT OVERWING EXIT EMERGENCY LIGHTS FAIL 10 MINUTE CHECK. REPLACED OVERWING EMERGENCY EXIT SIGN BATTERY PACK. (M)SDR AALA20011575Battery Pack · dischargedTUL - FOUND CENTER AISLE OVERHEAD FORWARD AND AFT OVERWING AREA EMERGENCY EXIT LIGHTS FAIL 10 MINUTE CHECK. REPLACED AISLE SIGN EMERGENCY EXIT BATTERY PACK. (M)SDR GAIA01291OPCoalescer Bag · dirtyFLT 2031 - RNO-DEN - AFTER TAKEOFF, THERE WAS A STRONG ODOR OF JET FUEL IN THE COCKPIT. THIS AIRCRAFT MADE AN UNEVENTFUL RETURN TO RNO. REMOVED AND REPLACED BOTH CONDENSER BAGS. INSPECTED AND CHECKED FOR LEAKS. RAN APU AND ENGINES WITH NO LEAKS OR SMELL NOSDR AALA20011602Light · damagedDFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY FLOOR PATH LIGHTING AT ROW 6 DAMAGED. REPLACED TRACK AND LIGHT ASSEMBLY. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA20011608Skin · gougedTUL - FOUND GOUGE IN SKIN AT STATION 936 BETWEEN STRINGER 3R AND 4R. INSTALLED DOUBLER REPAIR AT STATION 936 BETWEEN STRINGER 3R AND 4R PER SRM 53-30-3 PART 1. (M)SDR AALA20011609Shear Tie · corrodedTUL - FOUND SHEAR TIE CORRODED AT STATION 520 STRINGER 26 TOP SIDE. REMOVED AND REPLACED SHEAR TIE IAW SRM 51-10-1, TREATED, PRIMED PAINTED IAW MM 51-20-0. (M)SDR AALA20011593Light · inoperativeDFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT PATH LIGHTING IN AFT STAIRWELL INOPERATIVE. REPLACED LIGHT ASSEMBLY. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA20011580Battery Pack · dischargedTUL - AFT SLIDE LIGHTS INOPERATIVE, STATION 1143 EQUIP NR M983. REPLACED BATTERY PACK M983. (M)SDR AALA20011581Light · inoperativeTUL - FOUND AIRSTAIRS EMERGENCY EXIT LIGHT INOPERATIVE, STATION 1398. REPLACED LIGHT ASSEMBLY. (M)SDR AALA20011561Connector · disconnectedMIA - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT SIGN BETWEEN L1 AND R1 DOOR INOPERATIVE. RECONNECTED EMERGENCY SIGN CONNECTOR. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA20011562Light · inoperativeMIA - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT OVERHEAD LIGHTING INOPERATIVE. REPLACED EMERGENCY LIGHT ASSEMBLY. SYSTEM GROUND CHECK NORMAL OPERATION. (M)SDR AALA20011560Connector · damagedMIA - DURING OVERNIGHT MAINTENANCE, AFT ENTRY DOOR EMERGENCY LIGHT INOPERATIVE. REPLACED BAD CONNECTOR. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA20011549Light · inoperativeMIA - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT LIGHT AT R1 DOOR INOPERATIVE. REPLACED EMERGENCY EXIT LIGHT ASSEMBLY AT R1 DOOR. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA20011548Light · defectiveDFW - DURING OVERNIGHT MAINTENANCE CEILING EMERGENCY LIGHT AT SEAT ROW 8 DIM. REPLACED CEILING EMERGENCY LIGHT ASSEMBLY AT SEAT ROW 8. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA20011522Wire · damagedMIA - DURING OVERNIGHT MAINTENANCE, AFT ENTRY DOOR EMERGENCY EXIT ESCAPE PATH LIGHT INOPERATIVE. REPAIRED WIRE TO EMERGENCY EXIT ESCAPE PATH LIGHT AT AFT ENTRY DOOR. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR GAIA01286OPIndicator · inoperativeFLT 302 - GEG-SEA - ON DEPARTURE, INBOARD FLAPS FAILED TO RETRACT FROM TAKEOFF SETTING. AIRCRAFT MADE AN UNEVENTFUL RETURN LANDING AT GEG. FOUND INBOARD FLAP POSITION INDICATOR INOPERATIVE. REMOVED AND REPLACED INBOARD FLAP POSITION INDICATOR. OPS CHECK OFSDR AALA20011513Connector · disconnectedMIA - DURING OVERNIGHT MAINTENANCE, OVERHEAD EMERGENCY SIGN BETWEEN L1 AND R1 INOPERATIVE. RECONNECTED EMERGENCY EXIT SIGN CONNECTOR. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA20011525Light · inoperativeDTW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT LIGHT AT AFT STAIRWAY INOPERATIVE. REPLACED EMERGENCY EXIT LIGHT ASSEMBLY AT AFT STAIRWAY. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR EISA20010109Engine · inoperativeJUST AFTER ROTATION, SEVERAL COMPRESSOR STALLS WERE HEARD. GAUGES FOR #1 ENGINE SHOWED SOME FLUCTUATION; ENG. FAIL LIGHT FLASHED. ACCOMPANIED BY AUTO PACK TRIP. AIR TURN BACK TO INDIANAPOLIS.CORRECTIVE ACTION:INSP. INLET AND EXHAUST, NO DAMAGE NOTED, R/R PRBCSDR AALA20011506Contactor · brokenDFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT ESCAPE PATH LIGHTS AT 27D AND FORWARD DIM. REPLACED BROKEN CONDUCTOR AT R2 DOOR. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA20011493Connector · defectiveDFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT ESCAPE PATH LIGHTS VERY DIM. REPLACED EMERGENCY EXIT ESCAPE PATH LIGHT CONNECTORS AT FIRST CLASS FORWARD PARTITION. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA20011488Sign · inoperativeDFW - DURING OVERNIGHT MAINTENANCE, LEFT AFT SERVICE DOOR EXIT SIGN INOPERATIVE. REPLACED LEFT AFT SERVICE DOOR EXIT SIGN ASSEMBLY. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA20011469Wire · disconnectedDFW - DURING OVERNIGHT MAINTENANCE, FORWARD FLOOR EMERGENCY EXIT PATH LIGHTING INOPERATIVE. REATTACHED WIRE TO FLOOR EMERGENCY EXIT PATH LIGHT STRIP. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR C8GA20010016Door · not closedFLT 4201 FROM SAT TO DFW. DURING CLIMB, THE DOOR WARNING LIGHT CAME ON IN FLIGHT AND COULD NOT PRESSURIZED THE AIRCRAFT. AIR TURNBACK TO SAT AND LANDED WITHOUT INCIDENT. PERFORMED FORWARD ENTRY DOOR OPERATION AND INSPECTION, INSPECTED LATCHES AND LOCK CAM ASDR AALA20011414Light · defectiveTUL - LIGHT FLICKERS. REPLACED LIGHT OPS CHECKS GOOD. (M)SDR AALA20011485Floorbeam · corrodedTUL - FOUND RIGHT BUTT LINE 10 CORROSION ON TOP OF FLOORBEAM STATION 380. REPAIRED FLOORBEAM PER 53-10-08. (M)SDR AALA20011483Floorbeam · corrodedTUL - FOUND CORROSION ON THE TOP OF THE FLOORBEAM AND FAST HOLES STATION 380 RBL 20-60. CUT OUT AND REMOVED CORROSION AND INSTALLED REPAIRS PER 53-10-8 PAGE 9A AND 9B AND 53-10-8 FIG 1 STIFFENER REPAIRS AND FILLERS. (M)
Back to Boeing 727-223