Boeing 727-223

Service difficulty reports · 5,313

Newest first. General aviation reporting is voluntary.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE aircraft_model_key = '727223'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR AALA990942Overheat Loop · defectiveMIA - FLT 625 - AFTER TAEKOFF STRUT OVERHEAT LIGHT FLICKERED AT FL330. FLIGHT CREW PERFORMED EMERGENCY CHECKLIST AND LIGHT EXTINGUISHED. CLOSED NUMBER THREE BLEED VALVE AND DESCENDED TO FL250. OPENED NR 1 BLEED VALVE FOR REMAINDER OF FLIGHT WITH NO OVERHEATJun 24, 1999 · N874AA · Boeing 727223 · Overheat DetectionSDR AALA990933Connector · disconnectedMIA - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT FLOOR PATH LIGHTING IN COACH INOPERATIVE. SECURED EMERGENCY EXIT FLOOR PATH LIGHT STRIP CONNECTOR. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)Jun 23, 1999 · N710AA · Boeing 727223 · Emergency LightingSDR AALA991430Light · defectiveTPA - DURING OVERNIGHT, MAINTENANCE EMERGENCY EXIT LIGHT ABOVE AFT ENTRY DOOR DOES NOT TEST. REPLACED EMERGENCY EXIT LIGHT ABOVE AFT ENTRY DOOR. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)Jun 22, 1999 · N869AA · Boeing 727223 · Emergency LightingSDR AALA990967Window Frame · crackedTUL - R-1 WINDOW FRAME CRACKED UPPER RIGHT CORNER. INSTALLED REPAIR DOUBLER UPPER RT CORNER OF R-1 WINDOW FRAME PER SRM 53-30-3. (M)Jun 22, 1999 · N850AA · Boeing 727223 · Fuselage Miscellaneous StructureSDR AALA990924Battery · dirtyMIA - DURING OVERNIGHT MAINTENANCE, AFT STAIR EMERGENCY EXIT LIGHTS INOPERATIVE. CLEANED CONTACTS ON BATTERY PACK. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)Jun 22, 1999 · N884AA · Boeing 727223 · Emergency LightingSDR EISA99139Switch · out of adjustLANDING GEAR DOOR WARNING LIGHT AND NOSE GEAR DOOR WARNING LIGHT ILLUMINATED AT 275 ACCOMPLISHED ABNORMAL CHECKLIST. JACKED NOSE GEAR, SWUNG GEAR AND ADJUSTED GEAR DOORS PER MM 32-22. (M)Jun 18, 1999 · N311NE · Boeing 727223 · Landing Gear Position and WarningSDR GAIA9977Air Dist · odorFLT 1756 - HUF-CLT - AT FLT LVL 290 SMELLED ODOR FROM CARGO COMPARTMENT. EMERGENCY WAS DECLARED AND CHECKLIST COMPLETED. NORMAL LANDING AT CLT. PERFORMED HAZ MAT INSPECTION FOR POSSIBLE HAZ WASTE SPILLAGE IAW THE KHA GMM CHAPTER 18. NO DEFECTS NOTED. AIRCJun 17, 1999 · N6816 · Boeing 727223 · Air Distribution SystemSDR GAIA9976Light · inoperativeFLT 1725 - HUF-MCO - COCKPIT EMERGENCY EXIT LIGHT REMAINS ON. AIRCRAFT CONTINUED ON TO MCO WITH NO ADDITIONAL PROBLEMS NOTED AND MADE AN UNEVENTFUL LANDING IN MCO. REMOVED AND REPLACED EMERGENCY LIGHT ASSEMBLY. OPERATIONALLY TEST OF EMERGENCY LIGHTING SYSTEJun 17, 1999 · N6821 · Boeing 727223 · Emergency LightingSDR EISA99138Bracket · brokenON POSITION AND HOLD ON RUNWAY, THERE WAS A LOUD POP FOLLOWED BY NOSE GEAR DOOR LIGHT RETURNED TO GATE. REPLACED NOSE GEAR DOOR BRACKET AND ADJUSTED NOSE GEAR DOORS PER MM 32-22-0. (M)Jun 17, 1999 · N311NE · Boeing 727223 · Landing Gear Door Retract SectionSDR AALA990885Floor · corrodedTUL - EXFOLIATED CORROSION ON FLOOR PAN EXTRUDING UNDER AND CAUSING BULGING TO FLOOR STRAP ON FORWARD SIDE OF STATION 1183 BULKHEAD, AT LOWER RIGHT CORNER OF VAULT DOOR FRAME, RBL 14 - RBL 24. FABRICATED AND INSTALLED DOUBLER PER SRM 51-40-2 AND FLOOR PAN ON Jun 16, 1999 · N707AA · Boeing 727223 · Fuselage Floor PanelSDR AALA990881Connector · defectiveDFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT FLOOR PATH LIGHTING AT EXIT ROW 18 INOPERATIVE. REPLACED EMERGENCY EXIT FLOOR PATH LIGHT CONNECTOR. SYSTEM GROUND CHECKED NORMAL OPERATIONS. (M)Jun 16, 1999 · N712AA · Boeing 727223 · Emergency LightingSDR AALA990884Skin · crackedTUL - HFEC INDICATES CRACK IN FUSE SKIN AT FORWARD ENTRY DOOR LOWER HINGE CUTOUT. INSTALLED DOUBLER PER BSB 727-53-0198 PAGE 32, FIG 4 DETAIL IV. (M)Jun 15, 1999 · N707AA · Boeing 727223 · Fuselage Main, Plate/SkinSDR AALA990857Wire · looseSJU - DURING OVERNIGHT MAINTENANCE, LOWER EMERGENCY EXIT SIGN AT L1, R1, 16A, AND 18A INOPERATIVE. SECURED WIRES ON BATTERY PACK. SYSTEM GROUND CHECKED, NORMAL OPERATION. (X)Jun 13, 1999 · N712AA · Boeing 727223 · Light System WiringSDR AALA990853Light · defectiveDFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT AFT STAIR LIGHT INOPERATIVE. REPLACED EMERGENCY EXIT LIGHT ASSEMBLY. SYSTEM GORUND CHECKED, NORMAL OPERATION. (X)Jun 10, 1999 · N892AA · Boeing 727223 · Emergency LightingSDR AALA990852Terminal · brokenDFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT FLOOR PATH LIGHTING AFT CABIN INOPERATIVE. REPLACED SEVERAL TERMINAL ENDS ON EMERGENCY EXIT PATH LIGHTING. SYSTEM GROUND CHECKED, NORMAL OPERATION. (X)Jun 10, 1999 · N892AA · Boeing 727223 · Emergency LightingSDR AALA990851Connector · brokenMIA - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT FLOOR PATH LIGHTING AFT CABIN INOPERATIVE. REPAIRED CONNECTOR ON EMERGENCY EXIT FLOOR PATH LIGHTING. SYSTEM GROUND CHECKED, NORMAL OPERATION. (X)Jun 10, 1999 · N880AA · Boeing 727223 · Emergency LightingSDR AALA990886Floorbeam · corrodedTUL - CABIN FLOORBEAM CORRODED TOP SIDE RBL 52-62. REMOVED CORROSION AND INSTALLED REPAIRED DOUBLER PER AARD 53-10-07-2. (M)Jun 9, 1999 · N707AA · Boeing 727223 · Fuselage Main, Floor BeamSDR GAIA9971Shear Tie · corrodedFOUND DURING ROUTINE SCHEDULED MAINTENANCE AT THE OSC MAINTENANCE FACILITY. CORROSION ON SHEAR TIE AT BODY STATION 720, BETWEEN STRINGERS 25R AND 26R. REMOVED SHEAR TIE IAW B727 SRM 51-30-2. REMOVED DAMAGED AREA AND INSTALLED NEWLY FABRICATED SHEAR TIE, IAWJun 8, 1999 · N6833 · Boeing 727223 · Fuselage Miscellaneous StructureSDR GAIA9970Shear Tie · corrodedFOUND DURING ROUTINE SCHEDULED MAINTENANCE AT THE OSC MAINTENANCE FACILITY. CORROSION ON SHEAR TIE AT BODY STATION 700, LBL 12. REMOVED CORROSION ON SHEAR TIE AND FOUND TO BE OUT OF LIMITS IAW B727 SRM 51-10-1. REMOVED DAMAGED AREA AND INSTALLED NEW SHEAR TJun 8, 1999 · N6833 · Boeing 727223 · Fuselage Miscellaneous StructureSDR GAIA9969Web · corrodedFOUND DURING ROUTINE SCHEDULED MAINTENANCE AT THE OSC MAINTENANCE FACILITY. FLOOR WEB AT FRAME STATION 1170 TO 1175, RBL 26 WAS FOUND TO BE CORRODED. REMOVED CORRODED WEB IAW B727 SRM 51-30-2. INSTALLED NEW WEB IAW B727 SRM 51-30-2. ITEM RETURNED TO SERVICJun 8, 1999 · N6833 · Boeing 727223 · Fuselage Miscellaneous StructureSDR GAIA9968Angle · corrodedFOUND DURING ROUTINE SCHEDULED MAINTENANCE AT THE OSC MAINTENANCE FACILITY. THE FLOORBEAM AT FRAME STATINO 380, UPPER CHORD AFT FLANGE BETWEEN RBL 14 AND RBL 28, WAS FOUND TO HAVE CORROSION AND OUT OF SRM REPAIR TOLERANCE PER B727 SRM 51-10-1 AND SRM 51-10-6.Jun 8, 1999 · N6833 · Boeing 727223 · Fuselage Miscellaneous StructureSDR GAIA9967Angle · corrodedFOUND DURING ROUTINE SCHEDULED MAINTENANCE AT THE OSC MAINTENANCE FACILITY. RIGHT WING STATION 525, REAR SPAR STIFFENER ANGLE HAS CORROSION AT NR 12 SPOILER ACTUATOR OUTBOARD FLANGE. REMOVED AND REPLACED STIFFENER ANGLE IAW B727 SRM 51-30-02. SEALED FASTENEJun 8, 1999 · N6833 · Boeing 727223 · Wing Miscellaneous StructureSDR GAIA9966Beam · corrodedFOUND DURING ROUTINE SCHEDULED MAINTENANCE AT THE OSC MAINTENANCE FACILITY. CORROSION ON RIGHT WALKING BEAM FORWARD OF THE NR 8 SPOILER ACTUATOR. REWORKED RIGHT WALKING BEAM IAW, AMERICAN INTERNATIONAL AIRWAYS, ENGINEERING DEVIATION REQUEST B2-06492. FLAP PJun 8, 1999 · N6833 · Boeing 727223 · Wing Miscellaneous StructureSDR GAIA99065Actuator · leakingAFTER TAKEOFF OF SCHEDULED FLIGHT NUMBER 302 FROM SEA TO DFW, THE CREW SELECTED THE GEAR UP. THE LEFT GEAR WOULD NOT RETRACT. THE CREW RECYCLED THE LANDING GEAR, AND THE LEFT MAIN GEAR REMAINED EXTENDED. THE CREW ELECTED TO RETURN TO SEA. THE AIRCRAFT LANDJun 7, 1999 · N6811 · Boeing 727223 · Landing Gear Retraction/Extension SystemSDR EISA99132Wire · brokenA/C LOST PRESSURIZATION CONTROL. DROPPED TO 10,000 FT AND FLEW TO DFW. REPAIRED BROKEN WIRE ON RIGHT FLOW CONTROL VALVE. (M)Jun 6, 1999 · N311NE · Boeing 727223 · Air Conditioning System WiringSDR AALA990819Skin · crackedTUL - FOUND CRACKS AT 2 FASTENER HOLES BETWEEN 600 PLUS 620 STRINGER 4R CRACKS AT 2 FASTENER HOLES BETWEEN 620 AND 640, STRINGER 4R. CUT OUT DAMAGE 610-630, HFEC'D AREA. NO CRACKS BEYOND CUTOUT. INSTALLED .080 2024T3 DOUBLER USING EXISTING FASTENER SPACING Jun 2, 1999 · N847AA · Boeing 727223 · Fuselage Main, Plate/SkinSDR AALA990818Skin · crackedTUL - FOUND CRACKS AT 2 FASTENER HOLES BELOW STRINGER 4R AT SKIN LAP BETWEEN 640-660. CUT OUT DAMAGE 653-660. HFEC'D CUT OUT AREA NO FURTHER CRACKS INSTALLED .080 2024T3 DOUBLER USING EXISTING FASTENER SPACING PER SRM 53-30-03 PAGE 2023. (M)Jun 2, 1999 · N847AA · Boeing 727223 · Fuselage Main, Plate/SkinSDR AALA990817Skin · crackedTUL - FOUND CRACKS AT TWO EACH FASTENER HOLES BELOW STRINGER 4R AT SKIN LAP BETWEEN 500-520. CUT OUT DAMAGE 507-512, HFEC'D AREA, NO FURTHER CRACKS. INSTALLED .080 2024 T-3 DOUBLER USING EXISTING FASTENER SPACING PER SRM 53-30-03 PAGE 20-23. (M)Jun 2, 1999 · N847AA · Boeing 727223 · Fuselage Main, Plate/SkinSDR AALA990813Bulkhead Web · crackedTUL - APPROX 1 INCH CRACK IN STATION 870 BULKHEAD WEB AT APU LOAD CONTROL VALVE CUTOUT. STOP DRILLED CRACK AND INSTALLED REPAIR AS PER SRM 53-10-2 PAGE 261C. (M)Jun 2, 1999 · N703AA · Boeing 727223 · Fuselage Main, BulkheadSDR AALA990812Bulkhead Angle · crackedTUL - FOUND STATION 870 BULKHEAD TO KEELBEAM ATTACH ANGLE CRACKED RIGHT W/W. REPLACED CRACKED ANGLE WITH NEW. (M)Jun 2, 1999 · N703AA · Boeing 727223 · Fuselage Main, BulkheadSDR AALA990799Light · defectiveTPA - DURING OVERNIGHT MAINTENANCE, AFT STAIRS EMERGENCY EXIT LIGHTS OVERHEAD INOPERATIVE. REPLACED EMERGENCY EXIT OVERHEAD LIGHT ASSEMBLY. SYSTEM GROUND CHECKED, NORMAL OPERATION. (X)Jun 2, 1999 · N6823 · Boeing 727223 · Emergency LightingSDR GAIA9963Light · inoperative'NO FLIGHT' - FOUND DURING A-CHECK IN DFW. DURING ROUTINE MAINTENANCE AT DFW, THE EMERGENCY LIGHT OVER THE L-1 DOOR WAS FOUND TO BE INOPERATIVE. REMOVED AND REPLACED THE 'EMERGENCY EXIT' LIGHT ASSEMBLY AFTER THE L-1 DOOR. SYSTEM OPERATIONALLY CHECKS GOOD ANJun 1, 1999 · N6806 · Boeing 727223 · Emergency LightingSDR AALA990790Connector · defectiveDFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT FLOOR PATH LIGHTING BETWEEN FIRST CLASS AND COACH INOPERATIVE. REPAIRED EMERGENCY EXIT FLOOR PATH LIGHTING TRACK CONNECTOR. SYSTEM GROUND CHECKED, NORMAL OPERATION. (X)Jun 1, 1999 · N879AA · Boeing 727223 · Emergency LightingSDR GAIA9962Overheat Light · illuminatedAFTER DEPARATING PHTD EN ROUTE TO PHNL - FLT 7723 - JUST AFTER LEVEL OFF, LOWER AFT BODY OVERHEAT LIGHT ILLUMINATED. LIGHT GOES OUT AFTER ONE MINUTE, WHEN NR 3 THRUST LEVER IS RETARDED. LIGHT ALSO GOES OUT IF NR 3 BLEED IS CLOSED AND NR 2 BLEED IS OPEN. THRMay 30, 1999 · N854AA · Boeing 727223 · Overheat DetectionSDR EISA99124Compressor · stalledNR 2 ENGINE COMPRESSOR STALLS. REMOVED AND REPLACED NR 2 ENGINE. OPS CHECK GOOD. REPLACED 13TH STAGE SURGE BLEED VALVE. (M)May 30, 1999 · N6813 · Boeing 727223 · Turbine Engine Compressor SectionSDR GAIA9961Valve · failedYSSY/NZAA - FLT 6148 - DURING FLIGHT, NR 3 ENGINE STRUT OVERHEAT LIGHT CAME ON DURING CRUISE. CREW PEFORMED PROCEDURES PER OAM. LIGHT WENT OUT AFTER POWER REDUCTION. THE CREW MADE A ROUTINE LANDING AT NZAA WITHOUT ANY FURTHER INCIDENTS. AIR LEAK SOURCE FROMay 28, 1999 · N6809 · Boeing 727223 · Pneumatic Distribution SystemSDR AALA990815Frame · crackedTUL - CRACK IN FORWARD FRAME WEB NR 2 CARGO DOOR FRAME FROM LOWER DOOR STOP TO TOOLING HOLE. NO STOP DRILL REQUIRED. INSTALLED DOUBLER REPAIR PER S/B 727-53-A0199 DATED AUG 5, 1993 PER CARD 5295 PG A4. (M)May 28, 1999 · N703AA · Boeing 727223 · Cargo/Baggage DoorsSDR AALA990814Keel Beam · crackedTUL - FOUND LEFT KEEL BEAM CHORD CRACKED AT FORWARD FASTENER HOLE AT STATION 871 INSIDE KEEL BEAM, CRACK ENDED AT HOLE. INSTALLED DOUBLER REPAIR PER REV 1, S/B 727-53-0208, DATED FEB 29/96. (M)May 28, 1999 · N703AA · Boeing 727223 · Fuselage Main, KeelSDR AALA990778Wire · brokenDFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT FLOOR PATH LIGHT STRIP IN FIRST CLASS BROKEN. REPAIRED FLAT WIRE ON EMERGENCY EXIT FLOOR PATH LIGHT STRIP IN FIRST CLASS. SYSTEM GROUND CHECKED, NORMAL OPERATION. (X)May 28, 1999 · N880AA · Boeing 727223 · Light System WiringSDR AALA990810Skin · corrodedTUL - FOUND CORROSION ON CENTER TANK SKIN ABOVE LEFT AFT PLENUM. REMOVED CORROSION AND INSTALLED DOUBLER/TRIPLER REPAIR PER SRM 57-30-3. (M)May 27, 1999 · N703AA · Boeing 727223 · Wing, Plate/SkinSDR AALA99081Skin · gougedTUL - FUSELAGE SKIN GOUGED STRINGER 8R STATION 610, RED 'M' AREA. CUTOUT DAMAGED AREA OF SKIN. INSALLED DOUBLER PER SRM 53-30-3. (M)May 27, 1999 · N703AA · Boeing 727223 · Fuselage Main, Plate/SkinSDR AALA990775Wire · brokenMIA - DURING OVERNIGHT MAINTENANCE, MID-CABIN EMERGENCY EXIT FLOOR PATH LIGHTING INOPERATIVE. REPAIRED WIRE FOR MID-CABIN EMERGENCY EXIT FLOOR PATH LIGHTING. SYSTEM GROUND CHECKED, NORMAL OPERATION. (X)May 27, 1999 · N881AA · Boeing 727223 · Light System WiringSDR AALA990765Rib · crackedTUL - HFEC INDICATES CRACK .50 INCH APPROXIMATELY IN LEFT 70.5 WING T-CHORD RADIUS AT FS 751 (MARKED). REMOVED DAMAGED AREA AND INSTALLED REPAIR DOUBLERS AND OTHER REPAIR PARTS IAW SB 727-57-112 FIG 4 AND ESO 11697 DATED 5-24-99. TST: 47,052 HOURS. CYCLES:May 26, 1999 · N713AA · Boeing 727223 · Wing, Rib/BulkheadSDR EISA99123Bulkhead Web · gougedDURING ACCOMPLISHMENT OF ROUTINE C-CHECK WORK CARD, FOUND DRILL DAMAGE OF FS 1183 PRESSURE BULKHEAD AT WL 285 FROM LBL 18.2 TO RBL 18.2 (31 PLACES). REMOVED DAMAGED AREAS AND INSTALLED PERMANENT REPAIR PER ENGINEERING AUTHORIZATION (EA) NR 7-5310-77-C1529 ANDMay 24, 1999 · N312NE · Boeing 727223 · Fuselage Main, BulkheadSDR 99ZZZM396Bulkhead Web · gougedDURING ACCOMPLISHMENT OF ROUTINE C-CHECK WORK CARD, FOUND DRILL DAMAGE OF FS 1183 PRESSURE BULKHEAD AT WL 285 FROM LBL 18.2 TO RBL 18.2 (31 PLACES). REMOVED DAMAGED AREAS AND INSTALLED PERMANENT REPAIR PER ENGINEERING AUTHORIZATION (EA) NR 7-5310-77-C1529 ANDMay 24, 1999 · N312NE · Boeing 727223 · Fuselage Main, BulkheadSDR EISA99129Transmitter · serviceableDURING CLIMB, WHILE RETRACTING FLAPS FROM 5 DEGREES TO 2 DEGREES THE OUTBOARD FLAPS LOCKED OUT AT 4 DEGREES, THE INBOARD FLAPS WENT TO 0 DEGREES. CHECKED AND CLEANED CANNON PLUGS ON FLAP POSITION TRANSMITTERS, CLEANED AND LUBED JACKSCREWS, OPS CHECK OK MM 27-May 23, 1999 · N311NE · Boeing 727223 · Trailing Flap Position Indicating SystemSDR EISA99122Connector · dirtyDURING CLIMB WHILE RETRACTING FLAPS FROM 5 DEGREES TO 2 DEGREES THE OUTBOARD FLAPS LOCKED OUT AT 4 DEGREES. THE INBOARD FLAPS WENT TO ZERO. CHECKED AND CLEANED CANNON PLUS ON FLAP POSITION TRANSMITTER, CLEANED AND LUBED JACK SCREWS, OPS CHECKED OK. (M)May 23, 1999 · N311NE · Boeing 727223 · Trailing Flap Position Indicating SystemSDR AALA990763Chord · corrodedTUL - AFT VAULT DOOR ENTRY WAY, FS 1176 CHORD IS SEVERELY CORRODED BETWEEN CHORD AND WEB AT BL ZERO TO BL 8 RT. REMOVED CORROSION AREA OF CHORD STA 1176 BL ZERO TO BL 8 RT, INSTALLED DOUBLER PER ESO 11697 DATED 5-17-99. TST: 47,052 HOURS. CYCLES: 25,402. May 21, 1999 · N713AA · Boeing 727223 · Fuselage Miscellaneous StructureSDR AALA990764Skin · damagedTUL - SKIN DENTED AND SCRATCHED STA 410 STR 24R. CUT OUT DAMAGED SECTION AND INSTALLED DOUBLER PER SRM 53-30-3 PAGES 12-14A. TST: 47,052 HOURS. CYCLES: 25,402. (X)May 20, 1999 · N713AA · Boeing 727223 · Fuselage Main, Plate/SkinSDR GAIA9959Mechanism · out of adjustREF LOG SHEET 1591-30, DURING CLIMB-OUT OF FLIGHT KHA 717 FROM OKC TO MCI, THE RED GEAR LIGHT ON THE FORWARD INSTRUMENT PANEL, AND THE AMBER NOSE GEAR LIGHT ON THE FLIGHT ENGINEER'S PANEL BOTH ILLUMINATED WHEN THE AIRCRAFT REACHED AND EXCEEDED 250 KNOTS IAS WIMay 19, 1999 · N6812 · Boeing 727223 · Landing Gear Door Retract Section
Back to Boeing 727-223