As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
MIA - FLT 625 - AFTER TAEKOFF STRUT OVERHEAT LIGHT FLICKERED AT FL330. FLIGHT CREW PERFORMED EMERGENCY CHECKLIST AND LIGHT EXTINGUISHED. CLOSED NUMBER THREE BLEED VALVE AND DESCENDED TO FL250. OPENED NR 1 BLEED VALVE FOR REMAINDER OF FLIGHT WITH NO OVERHEAT INDICATION. MAINTENANCE FOUND STRUT OVERHEAT LOOP FAULTY. REPLACED STRUT OVERHEAT LOOP. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)