Boeing 727-22C
Service difficulty reports · 2,328
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '72722C' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '72722C' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR RAAAB196003Spar Cap · corrodedDURING SCHEDULED C-CHECK, INSPECTION OF RIGHT WING FOUND FORWARD LOWER SPAR CAP CORRODED AT WS 410. REPAIRED PER BOEING MSG 7271-96-0571. (M)SDR 96ZZZX1639Retract Mech · malfunctionedON APPROACH INTO IND, LANDING GEAR HAD TO BE CYCLED THREE TIMES TO GET A DOWN AND LOCKED INDICATION ON THE RT MAIN GEAR. THE RED LIGHT REMAINED ON AND A GO-AROUND WAS INITIATED. AS THE AIRCRAFT PITCHED UP, THE LIGHT EXTINGUISHED AND THE GREEN LIGHT ILLUMINATSDR RAAAB196002Battery Pack · dischargedROW 22 FLOOR PROXIMITY EGRESS LIGHT FAILED SERVICE CHECK. REPLACED BATTERY PACK DUE TO LOW CHARGE. (X)SDR CKSA95165Bulb · failedBYH-EWR - NOSE GEAR LIGHT WENT OUT, CYCLED GEAR, LIGHT CAME ON NORMALLY. THEN WENT OUT AGAIN TURNING SWITCH TO BRIGHT LIGHT CAME ON AGAIN. CHECKED NOSE GEAR DOWNLOCK SWITCH FOR CONDITION/SECURITY, FOUND OK. RELAMPED NOSE GEAR INDICATION LIGHT CAPSULE. OPS SDR UPS205152Retract Mech · lack of lubeCREW REPORTED, NOSE GEAR DID NOT EXTEND ON FIRST ATTEMPT AND RED DOOR LIGHT ON FWD PANEL. MAIN GEAR EXTENDED NORMALLY AND ALL GEAR EXTENDED NORMALLY ON SECOND ATTEMPT. JACKED NOSE GEAR AND LUBED NOSE GEAR, RETRACTED AND EXTENDED GEAR SEVERAL TIMES AND OPS CHSDR 95FDEA01807Fitting · crackedBS 870 LT TERMINAL FITTING LOWER HOLE NR 4 SHOWS CRACK WITH A HFEC AT STR 9 TO 10. STOP DRILLED CRACK, FABRICATED REPAIR PARTS AND DOUBLER IAW 727-53-0194 BOEING SB AND INSTALLED ON A/C PER BOEING SB 727-53-0194.SDR 95FDEA01806Floorbeam · corrodedHEAVY CORROSION ON FLOORBEAM STA 560 LBL 0 TO 22. REMOVED CORROSION, FABRICATED REPAIR PIECES IAW 53-10-8, INSTALLED REPAIR PIECES, DOUBLER AND FASTENERS PER 53-10-8.SDR 95FDEA01805Floorbeam · corrodedSTA 600 RBL 60 TO 41 WL 208.1 FLOORBEAM HAS CORROSION ON UPPER AND LWR LANDING. REMOVED TOP FLANGE OF FLOORBEAM RBL 44 TO 56 PER SRM 53-10-8 FIG 5 AND FABRICATED REPAIR AND INSTALLED PER SRM 53-10-8 FIG 5, 51-10-6 AND 51-10-1.SDR 95FDEA01804Clip · corrodedWING TEE CLIP STA 760 RBL 665 HAS CORROSION. REMOVED CORRODED TEE CLIP, COLD WORKED HOLES PER EO 7-5710-7-2308 AND INSTALLED TEE CLIP.SDR 95FDEA01803Floorbeam · corrodedFLOORBEAM HAS CORROSION STA 680 LBL 50 TO 55. CUT AWAY CORRODED AREA FABRICATED REPAIR PARTS AND INSTALLED PER SRM 53-10-8.SDR 95FDEA01809Fitting · crackedSEVERAL STR END FITTINGS AT STA 870 AND 740 CRACKED ON INNER LANDING STR 8R AND L MPN'S 69-16380-3 AND 69-34593-1. REMOVED AND REPLACED END FITTINGS PER STANDARD PRACTICE.SDR 95FDEA01808Frame · crackedBS 804.5 LT SIDE 23 ABOVE WL 208.1 STR 14 FRAME CRACKED. STOP DRILLED CRACK AND INSTALLED DOUBLER PER 51-40-3.SDR RAAAB195020Battery Pack · dischargedROW 17 FLOOR PROXIMITY EGRESS LIGHT FAILED SERVICE CHECK. REPLACED BATTERY PACK DUE TO LOW CHARGE. (X)SDR RAAAB195019Battery Pack · dischargedLEFT AFT OVERWING EMERGENCY EXIT EGRESS IDENTIFIER LIGHT FAILED SERVICE CHECK. CHANGED BATTERY PACK DUE TO LOW CHARGE. (X)SDR RAAAE196001Battery Pack · dischargedROW 17 FLOOR PROXIMITY EGRESS LIGHT FAILED SERVICE CHECK. REPLACED BATTERY PACK DUE TO LOW CHARGE. (X)SDR UPS205015Battery · missingWHILE ON GROUND, MAINTENANCE FOUND EMERGENCY EXIT LIGHT IN FLIGHT DECK INOP. BATTERIES ROBBED FOR A/C 212 FROM 929. REMOVED AND REPLACED 2 BATTERIES, OPS GOOD.SDR 95FDEA01699Fittings · crackedSEVERAL STRINGER END FITTINGS AT STA 870 TO 740 CRACKED ON INNER LANDING STR 8 RT AND LT MPN'S 69-16380-3 AND 69-34593-1.SDR 95FDEA01693Floorbeam · corrodedFLOORBEAM STA 640 LBL 53 HAS CORROSION.SDR 95FDEA01692Floorbeam · corrodedCORROSION ON FLOORBEAM STA 640 RBL 21 TO 58.SDR 95FDEA01691Floorbeam · corrodedFLOORBEAM HAS CORROSION STA 680 LBL 50 TO 55.SDR 95FDEA01690Clip · corrodedWING TOE CLIP STA 760 LBL 65 HAS CORROSION.SDR RAAAB195018Battery Pack · dischargedROW 17 FLOOR PROXIMITY EGRESS LIGHT FAILED SERVICE CHECK. REPLACED BATTERY PACK DUE TO LOW CHARGE. (X)SDR RAAAB195017Battery Pack · dischargedROW 14 FLOOR PROXIMITY EGRESS LIGHT FAILED SERVICE CHECK. REPLACED BATTERY PACK DUE TO LOW CHARGE. (X)SDR RAAAB195016Battery Pack · dischargedRIGHT AFT OVERWING EMERGENCY EXIT EGRESS IDENTIFIER LIGHT FAILED SERVICE CHECK. CHANGED BATTERY PACK DUE TO LOW CHARGE. (X)SDR RAAAB195015Battery Pack · dischargedLEFT FORWARD ENTRANCE DOOR EGRESS LIGHT INOPERATIVE. REPLACED BATTERY PACK DUE TO LOW CHARGE. (X)SDR UPS204928Battery · dischargedWHILE ON THE GROUND IN CGN, MAINTENANCE FOUND EMERGENCY LIGHT DOES NOT COME ON WHEN SWITCHED TO ON. MAINTENANCE REPLACED THE BATTERIES, FUNCTIONAL CHECKS GOOD.SDR UPS204917Accumulator · leakingON DESCENT OUT OF 24,000 FEET 85 MILES NORTHWEST OF JAX, THE A-HYDRAULIC QTY GAUGE WENT TO ZERO. THE LEFT A-HYD LOW PRESSURE LIGHT CAME ON FOLLOWED BY THE RIGHT ONE. PILOT CALLED FOR THE A-HYDRAULIC LEAK OR LOSS CHECK LIST. MANUAL GEAR EXTENSION WAS INITIATSDR RAAAB295025Transmitter · inoperativeAFT PASSENGER CABIN EGRESS TRANSMITTER FAILED SERVICE CHECK. CHANGED UNIT. (X)SDR UPS804865Battery · dischargedWHILE ON GROUND, MAINTENANCE FOUND EMERGENCY EXIT LIGHTS OVER THE FORWARD ENTRY DOOR INOP. MAINTENANCE REMOVED AND REPLACED FWD ENTRY DOOR EMERGENCY LIGHTING BATTERIES, OPS CK GOOD.SDR RAAAB295024Light · inoperativeROW 22 FLOOR PROXIMITY LIGHT FAILED SERVICE CHECK. REPLACED LIGHT ASSEMBLY. (M)SDR 95ZZZM660Return Line · crackedEN ROUTE FROM IND TO DEN, THE AIRCRAFT STARTED LOOSING 'A' SYSTEM HYDRAULIC QUANTITY. AIRCRAFT LANDED WITHOUT INCIDENT. FOUND NR 2 SPOILER ACTUATOR RETURN LINE CRACKED AT T-FITTING B-NUT. REPLACED LINE, BOTH 'A' SYSTEM HYDRAULIC PUMPS AND 'A' SYSTEM RETURN SDR RAAAB295023Light · inoperativeRIGHT FORWARD OVERWING EXIT EGRESS LIGHT FAILED SERVICE CHECK. REPLACED LIGHT ASSEMBLY. (M)SDR RAAAB295022Light · inoperativeROW 22 FLOOR PROXIMITY LIGHT FAILED SERVICE CHECK. REPLACED LIGHT ASSEMBLY. (M)SDR 95ZZZX6212Rivet · missingNO DOWN AND LOCKED INDICATION OF NOSE GEAR UPON DESCENT INTO SEA. CYCLED GEAR ONCE AND GREEN LIGHT ILLUMINATED AFTER APPROXIMATELY 4 MINUTES. FOUND 2 OF 3 RIVETS RETAINING NOSE GEAR LOCK SWITCH MOUNT BRACKETS TO NOSE GEAR BRACES MISSING ALLOWING SWITCH TO ROSDR RAAAB195014Battery Pack · dischargedLEFT FORWARD OVERWING EMERGENCY EXIT EGRESS IDENTIFIER LIGHT FAILED SERVICE CHECK. CHANGED BATTERY PACK DUE TO LOW CHARGE. (X)SDR UPS204523Eel Cb · trippedWHILE ON GROUND, MAINTENANCE PREFLIGHT CREW FOUND EMERGENCY LIGHTS CHARGER C/B POPPED. A/C 214 COVERED FLT W/E PHL.SDR UPS204514Eel Battery Pack · dischargedWHILE ON GROUND, MAINTENANCE FOUND EMERGENCY EXIT LIGHT ABOVE CONTROL CABIN DOOR WILL NOT ILLUMINATED WITH EMERGENCY EXIT LIGHT SWITCH ON. EMERGENCY EXIT LIGHT ASSY BATTERIES REPLACED AND LIGHTS CHECKED SERVICEABLE.SDR UPS204513Eel · inoperativePILOT REPORTED, ON TAKEOFF ROLL EMERGENCY EXIT LIGHT OVER CABIN ENTRY DOOR AND FWD ENTRY DOOR ILLUMINATED. CYCLED SWITCHES ON OVERHEAD PANEL, UNDER COVER, NO CHANGE AND HAD TO TURN OFF FOR LIGHTS TO EXTINGUISH. FOUND EMERGENCY LIGHT C/B POPPED, RESET D/B. SDR 95ZZZM547Bleed Duct · leakingNR 3 ENGINE FIRE WARNING SOUNDED IN FLIGHT. DISCHARGED LEFT FIRE BOTTLE. INSPECTED NR 3 ENGINE FOR FIRE DAMAGE, NONE FOUND. REPLACED NR 3 ANTI-ICE VALVE, 13TH STAGE BLEED DUCT AND ASSOCIATED CLAMPS AND SEALS. REPLACED LEFT FIRE BOTTLE. (M)SDR RAAAB195013Pbe · inflatedDURING SERVICE CHECK, FOUND BULKHEAD P.B.E. GREEN SEAL MISSING AND LOSS OF VACUUM. CHANGED P.B.E. (X)SDR UPS204430Eel Cb · openWHILE ON THE GROUND, CREW FOUND EMERGENCY EXIT LIGHT IN COCKPIT IS ON IN ARMED POSITION. FOUND EMERGENCY EXIT LIGHT BATTERY CHARGER CB OPEN. RESET AND NO FURTHER PROBLEMS NOTED. OPERATIONAL TEST GOOD PER MM 33-50-01.SDR UPS204397Eel · malfunctionPILOT REPORTED EMERGENCY, CIRCUIT BREAKER TRIPPED AFTER TAKEOFF. CYCLED EMERGENCY LIGHT SWITCH NUMEROUS TIMES. COULD NOT DUPLICATE. REPLACED EMERGENCY LIGHT OVER ENTRANCE DOOR, PRECAUTIONARY.SDR 95FDEA01283Frame · bentCORROSION LOWER SIDE OF FWD FLANGE STA 480 FLOOR FRAME RBL 3 TO 6. REMOVED CORROSION INSTALLED REPAIR PER 53-10-8 FIG 5 PG 31.SDR 95FDEA01275Floorbeam · corrodedCORROSION ON TOP OF FLOOR BEAM C/L TO LBL 24 STA 560, MAIN CARGO LOBE. REMOVED CORROSION AND REPAIRED FLOORBEAM PER SRM 53-10-5 PG 31 TO 48.SDR UPS204360Eel · malfunctionWHILE ON GROUND AT CGN, MAINTENANCE FOUND DURING TESTING, LIGHTS GOING DIM RAPIDLY. MAINTENANCE REPLACED ASSY, F/C GOOD.SDR 95FDEA01282Frame · bentNR 0413 UPPER LOBE FRAME BENT 3 INCHES ABOVE RT FLOOR LINE STA 500. REMOVED DAMAGED AREA, INSTALLED DOUBLER PER 51-40-3 PG 3.SDR 95FDEA01253Stringer · crackedMAIN CARGO, NR 7L STR AT STA 460 CRACKED. CUTOUT CRACKED STR SECTION. REPAIRED PER SRM 53-10-3 PAGE 7, FUSELAGE STR REPAIR.SDR 95FDEA01249Frame · bentUPPER LOBE FRAME BENT 3 INCHES ABOVE RT FLOOR LINE STA 500. REMOVED DAMAGED AREA INSTALLED DOUBLER PER 51-40-3 PG 3.SDR 95FDEA01248Frame · bentUPPER LOBE FRAME BENT 3 INCHES ABOVE RT FLOOR LINE STA 520. REMOVED DAMAGED AREA OF FRAME AND INSTALLED REPAIR PER SRM 51-40-3 PG 1 TO 4.SDR 95FDEA01247Frame · crackedFRAME BENT AND CRACKED STA 540 AT STR 7 TO 6R. REMOVED DAMAGED AREA, INSTALLED DOUBLER PER SRM 51-10-4 PG 3 AND 4.
Back to Boeing 727-22C