Boeing 727-2J4
Service difficulty reports · 741
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '7272J4' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '7272J4' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR 97ZZZX2507Pcu · leakingLEFT ELEVATOR PCU LEAKING. REMOVED AND REPLACED PCU IAW BAC 727 MM 27-30-81.SDR 97ZZZX2506Angle · corrodedCORROSION AT FS 351.2 RIGHT SIDE OF NOSE GEARBOX ON ANGLE BELOW FLOOR LEVEL. REPAIRED ANGLE IAW BAC SRM 727-51-40-03.SDR 97ZZZX2505Panel · corrosionBLOW OUT PANEL 3458 HAS CORROSION AT BONDING WIRE ATTACH. FABBED AND INSTALLED NEW PANEL 3458 IAW 727 SRM'S 51-40-3 AND 51-30-2.SDR 97ZZZX2504Z Channel · corrodedCORROSION ON Z-CHANNEL AT FS 320 RT NOSE GEARBOX. REAPAIRED EXTRUSION IAW BAC 727 SRM 51-40-4 PG 5.SDR 97ZZZX2503Panel · corrodedPANEL 9501 CORRODED BEYOND LIMITS AT FASTENER HOLES. FABBED AND INSTALLED NEW REPAIR PARTS PER 727 SRM'S 55-30-7 AND 51-30-02.SDR 97ZZZX2502Seat Track · corrodedFWD GALLEY SEAT TRACK CORRODED. REPLACED SEAT TRACK IAW BAC 727 SRM'S 51-40-4, 51-30-2.SDR 97ZZZX2501Support · corrodedFWD LAVATORY SUPPORT CORRODED. REPLACED SUPPORT IAW BAC 727 SRM'S 51-30-5, 51-30-2.SDR 97ZZZX2500Seat Track · corrodedSEAT TRACK CORRODED BS 1090 - BS 1140 RBL 24. REPLACED SEAT TRACK IAW BAC 727 SRM 53-10-5.SDR 97ZZZX2499Stringer · crackedCRACK IN STRINGER AT BS 481 STR 8L. REPAIRED IAW BAC 727 SRM'S 53-30-3, 51-30-2.SDR 97ZZZX2498Panel · corrodedFWD PIT CORROSION UNDER TRANSITION PANEL AT FS 650 RBL 18. REPAIRED IAW BAC 727 SRM'S 51-10-6, 51-20-1, 51-10-2, AND 51-30-2.SDR 97ZZZX2497Panel · corrodedFORWARD PIT, CORROSION UNDER TRANSITION PANEL AT FS 620 RBL 18. REPAIRED IAW BAC 727 SRM'S 53-10-1, 53-10-2, 51-20-1, 51-30-2.SDR 97ZZZX2496Stringer · corrodedCORROSION ON STR 26L BETWEEN FS 700 - FS 720. REPAIRED IAW BAC727 SRM 53-10-3 DETAIL I.SDR 97ZZZX2495Angle · corrodedAFT GALLEY FLOOR 'L' ANGLE CORRODED. REPAIRED IAW BAC 727 SRM 51-10-6 AND SRM 51-10-1.SDR 97ZZZX2494Angle · corrodedFLOOR ANGLE CORRODED AT L-2 DOOR. REPAIRED ANGLE IAW BAE 727 SRM 51-20-1.SDR 97ZZZX2493Doubler · corrodedDOUBLER AT SERVICE DOOR PAN FOUND CORRODED OUT OF LIMITS IAW 727 SRM 53-30-01. REPAIRED IAW 727 SRM 51-20-1 AND SRM 51-30-2.SDR 97ZZZX2492Floor Beam · corrodedCORROSION ON FLOOR BEAM FS 1166 RBL 12. REPLACED FLOOR BEAM SECTION IAW SRM 51-30-2 AND SRM 53-10-5 FIG 6.SDR 97ZZZX2491Track · corrodedFWD GALLEY NR 1 INBD SEAT TRACK CORRODED. INSTALLED SEAT TRACK IAW 727 SRM 51-30-2.SDR 97ZZZX2490Floor Beam · corrodedCORROSION ON FLOOR BEAM FS 1166 AND LBL 6. REMOVED AND REPLACED DAMAGED SECTION FS 1166 - IAW 727 SRM 53-10-5 FIG 6 AND SRM 51-30-2.SDR 97ZZZX2489Floor Beam · corrodedCORROSION ON FLOOR BEAM FS 1166 AND LBL 3. REMOVED AND REPLACED DAMAGED SECTION IAW 727 SRM 53-10-5 FIG 6 AND SRM 51-30-2.SDR 97ZZZX2488Panel · corrodedCORROSION ON TRANSITION PANEL FS 1070 - FS 1130. FABBED NEW PANEL IAW 727 SRM 51-20-1 AND SRM 51-30-2.SDR 97ZZZX2487Skin · gougedGOUGE IN SKIN STA 277L STR 17L. GOUGE IS BEYOND LIMITS. REPAIR IAW SRM 53-30-3 FIG 1.SDR SCNA97138Battery Pack · dischargedTHE RIGHT OVERWING EMERGENCY LIGHTS BLINK ON AND OFF. REPLACED BATTERY PACK AND POWER SUPPLY AND LIGHT CHECKED GOOD.SDR SCNA97137Power Supply · inoperativeTHE FORWARD AISLE EMERGENCY LIGHT AT SEAT 11 INOPERATIVE. REPLACED POWER SUPPLY AND LIGHT, OPS CHECKED GOOD.SDR SCNA97124Batteries · dischargedTHE FORWARD AISLE EMERGENCY SELF-CONTAINED EXIT LIGHT WAS FOUND INOPERATIVE. REMOVED AND REPLACED BATTERIES IN FORWARD AISLE EMERGENCY EXIT LIGHTS.SDR SCNA97112Lamp · failedTHE AFT AIRSTAIRS EMERGENCY LIGHTS WERE FOUND TO BE INOPERATIVE. RELAMPED EMERGENCY LIGHTS, LIGHTS CHECKED NORMAL.SDR SCNA97088Batteries · dischargedCOCKPIT EMERGENCY EXIT LIGHT WAS FOUND INOP. REPLACED BATTERIES AND FUNCTIONALLY TESTED. NO DISCREPANCIES NOTED.SDR SCNA97082Bulb · failedTOP LAMP IN EMERGENCY EXIT SIGN WAS FOUND INOP AT R2 DOOR. RELAMPED AND OPS CHECKED GOOD IN ACCORDANCE WITH MM 33-50-00.SDR 97ZZZX1736Frame · corrodedDURING C-CHECK INSPECTION, LEVEL 2 CORROSION WAS FOUND ON FUSELAGE FRAME 950A BETWEEN S19L AND S20L.SDR SCNA97078Battery · dischargedFORWARD LAV SMOKE DETECTOR BEEPED. REMOVED AND REPLACED BATTERY AND TESTED NORMAL.SDR SCNA97075Bulb · failedL-2 DOOR EMERGENCY SLIDE LIGHT WAS FOUND INOP. REMOVED AND REPLACED BULB AND SYSTEM, FUNCTIONALLY CHECKED NORMAL.SDR SCNA97074Battery Charger · inoperativeFOUND BATTERY CHARGER BAD FROM STOCK. REMOVED AND REPLACED BATTERY CHARGER.SDR SCNA97073Battery Charger · inoperativeFOUND AFT RIGHT OVERWING EMERGENCY EXIT LIGHT INOP. REMOVED AND REPLACED BATTERY CHARGER AND FUNCTIONALLY CHECKED GOOD.SDR SCNA97067C1 Blades · damagedAT APPROXIMATELY 50 FEET, FOD WAS INGESTED INTO THE NUMBER 1 ENGINE, THE ENGINE FAIL LIGHT ILLUMINATED WITH AURAL WARNING, AND THE NUMBER 1 ENGINE N1 FLUCTUATED. REDUCED NUMBER 1 ENGINE POWER TO IDLE AND ALL GAUGES INDICATED NORMAL. FOUND DAMAGE LIMITED TO TSDR SCNA97066Batteries · dischargedAFT AIRSTAIR OVERHEAD EMERGENCY LIGHTS FOUND DIM. REMOVED AND REPLACED BATTERIES AND OPS CHECKED GOOD.SDR SCNA97059Battery Pack · dischargedR1 AND L1 DOOR EXIT SLIDE LIGHTS ARE INOP. REMOVED AND REPLACED ASSOCIATED BATTERY PACK. ALL EMERGENCY LIGHTS CHECK GOOD.SDR 97ZZZX1738Stringer · corrodedDURING C-CHECK INSPECTION, LEVEL 2 CORROSION WAS NOTED ON S23L FROM STA 277 TO STA 294.5.SDR 97ZZZX1737Spar Cap · corrodedDURING C-CHECK INSPECTION, LEVEL 2 CORROSION WAS NOTED ON LOWER FWD SPAR CAP AT RT WING STA 560 AT ATTACH POINT FOR LOWER LEADING EDGE ACCESS PANEL. APPARENTLY CAUSED BY INADEQUATE PREVENTIVE TREATMENT.SDR 97ZZZX1735Stiffener · corrodedDURING C-CHECK INSPECTION, LEVEL 2 CORROSION WAS NOTED ON TOP NOSE GEARBOX HORIZONTAL SITFFENER, FROM END TO END, AT STA 294.5 (AS VIEW FROMT HE E/E BAY).SDR 97ZZZX1734Stiffener · corrodedDURING C-CHECK INSPECTION, LEVEL 2 CORROSION WAS NOTED ON TOP NOSE GEARBOX HORIZONTAL STIFFENER AT STA 312 (AS VIEWED FROM THE E/E BAY).SDR AU971262Wheel · fractured(AUS) NO4 MAIN WHEEL HALF FAILED IN THE CENTRE HUB AREA. DAMAGE CAUSEDTO THE BRAKE AND WHEEL BEARING. FUSE PLUG MELTED AND TYRE DEFLATED.SDR AU970147Wheel · fractured(AUS) NO4 MAIN WHEEL CENTRE HUB FAILED. DAMAGE TO BRAKE AND WHEEL BEARING. FUSE PLUG MELTED AND TYRE DEFLATED.SDR SCNA97030Batteries · dischargedOVER AISLE EMERGENCY LIGHT INOP AT SEAT 11. REMOVED AND REPLACED BOTH BATTERIES AND OPS CHECKED GOOD.SDR SCNA97015Battery Pack · dischargedFOUND EMERGENCY FLOOR TRACK LIGHTING INOP IN ROWS 19 THROUGH 26. REMOVED AND REPLACED BATTERY POWER SUPPLY AND OPS CHECKED NORMAL.SDR SCNA97010Coalescer Bags · contaminatedCREW REPORTED SMOKE IN CABIN. AIRCRAFT RETURNED TO GATE. REPLACED COALESCER BAGS, INSPECTED PNEUMATIC SYSTEM, PERFORMED ENGINE RUNS, AND NO DEFECTS NOTED. FOUND LEFT ACM WITH EVIDENCE OF SEAL LEAKAGE BETWEEN CASE HALVES, REMOVED AND REPLACED ACM. ALSO REMOSDR SCNA97009Battery Pack · dischargedFORWARD CEILING MOUNTED AREA LIGHT WAS FOUND INOP. REMOVED AND REPLACED BATTERIES AND OPS CHECKED GOOD IN ACCORDANCE WITH MM 33-50-81.SDR SCNA97006Light · inoperativeAFT EMERGENCY TRACK LIGHT WAS FOUND INOP. REPLACED PIGTAIL ASSEMBLY, LENS, AND LAMP AND OPS CHECKED GOOD IN ACCORDANCE WITH MM 33-50-00.SDR SCNA97001Door · not latchedCABIN WOULD NOT PRESSURIZE, L-2 DOOR WAS NOT SEALED PROPERLY. DUMPED FUEL AND RETURNED TO CUN. VISUALLY INSPECTED DOOR L-2 AND FRAME AND NO DAMAGE WAS FOUND. SECURED DOOR AND DISPATCHED AIRCRAFT.SDR SCNA97003Bulb · failedFOUND AFT AIRSTAIR EMERGENCY LIGHTS INOP. RELAMPED 3 EMERGENCY LIGHTS AND OPS CHECKED GOOD.SDR SCNA96462Lamp · inoperativeCOCKPIT EMERGENCY LIGHT UNARMED LIGHT WAS FOUND INOP. RELAMPED FIXTURE AND OPS CHECKED GOOD.SDR SCNA96461Battery Pack · dischargedFOUND COCKPIT EMERGENCY EXIT LIGHT INOP. REMOVED AND REPLACED BATTERIES AND OPS CHECKED GOOD.
Back to Boeing 727-2J4