Boeing 737-290C
Service difficulty reports · 1,409
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '737290C' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '737290C' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR ASAA0110027Shear Tie · corrodedPHX - DURING SCHEDULED D-CHECK, FOUND SHEAR TIE AT BS 967, STRINGER 24L-26L, CORRODED. REPAIRED PER SRM. (M)SDR ASAA0110022Tie Clip · corrodedPHX - DURING SCHEDULED D-CHECK, FOUND TIE CLIP AT BS 867, STRINGER 20L CORRODED. REPAIRED PER SRM. (M)SDR ASAA0110021Floor Support · damagedPHX - DURING SCHEDULED D-CHECK, FLOOR SUPPORT HAS DOUBLER DRILLED HOLES AT BS 1006-1016, LBL 18. REPAIRED PER SRM. (M)SDR ASAA0110020Skin · chafedPHX - DURING SCHEDULED D-CHECK, FOUND RIGHT HORIZONTAL STABILIZER CHAFED ON TRAILING EDGE OF STATION 121.5. REPAIRED PER SRM. (M)SDR ASAA0110019Light · inoperativeSEA - DURING MAINTENANCE CHECK, FOUND EMERGENCY EXIT LIGHT AT THE R1 DOOR INOPERATIVE. REMOVED AND REPLACED LIGHT ASSEMBLY AND LIGHT FUNCTIONED PROPERLY. (M)SDR ASAA0110018Battery · dischargedSEA - DURING MAINTENANCE CHECK, FOUND SMOKE BARRIER EMERGENCY EXIT LIGHT BATTERY WOULD NOT TEST. REMOVED AND REPLACED REMOTE ASSEMBLY BATTERY AND LIGHT OPERATED NORMALLY. (M)SDR ASAA0110017Skin · damagedPHX - DURING SCHEDULED D-CHECK, FOUND FUSELAGE SKIN DING OUT OF LIMITS AT BS 954, STRINGER 20R-21R. REMOVED DAMAGED SECTION OF SKIN AND REPAIRED PER SRM. (M)SDR ASAA0110011Web · corrodedPHX - DURING SCHEDULED D-CHECK, FOUND WEB CORRODED. REMOVED AND REPLACED WEB PER SRM. (M)SDR ASAA0110012Web · crackedPHX - DURING SCHEDULED D-CHECK, FOUND FLOOR WEB CRACKED. REMOVED, FABRICATED AND REPLACED FLOOR WEB PER SRM. (M)SDR ASAA0110006Stiffener · corrodedPHX - DURING SCHEDULED D-CHECK, FOUND CORROSION AT NUT CLIP HOLES ON UPPER AND LOWER SIDE OF FLOORBEAM STIFFENER. REMOVED AND REPLACED FLOORBEAM STIFFENER PER SRM. (M)SDR 20010212SG002Battery · dischargedSEA - DURING MAINTENANCE CHECK, FOUND EMERGENCY EXIT LIGHTS AT ROW 18 INOPERATIVE. REMOVED AND REPLACED REMOTE ASSEMBLY RECEIVER AND BATTERY. LIGHTS OPERATED NORMALLY. REF ASAA0110003. (M)SDR ASAA0110003Receiver · inoperativeSEA - DURING MAINTENANCE CHECK, FOUND EMERGENCY EXIT LIGHTS AT ROW 18 INOPERATIVE. REMOVED AND REPLACED REMOTE ASSEMBLY RECEIVER AND BATTERY. LIGHTS OPERATED NORMALLY. (M)SDR ASAA0110001Battery · dischargedSEA - DURING MAINTENANCE CHECK, EMERGENCY LIGHT TRANSMITTER INOPERATIVE. REMOVED AND REPLACED EMERGENCY LIGHT TRANSMITTER BATTERY. LIGHTS OPERATED NORMALLY. (M)SDR ASAA0010192Stringer · corrodedPHX - DURING SCHEDULED D-CHECK, FOUND STRINGER CORRODED BEYOND LIMITS. REMOVED, FABRICATED AND REPLACED STRINGER FRAME PER SRM. (M)SDR ASAA0010191Frame · corrodedPHX - DURING SCHEDULED D-CHECK, FOUND STUB FRAME CORRODED BEYOND LIMITS. REMOVED, FABRICATED AND REPLACED STUB FRAME PER SRM. (M)SDR ASAA0010188Strap · crackedPHX - DURING SCHEDULED D-CHECK, FOUND STRAP AT BS 310-352, BUTTOCK LINE 24R CRACKED. INSTALLED NEW STRAP PER SRM. (M)SDR ASAA0010187Skin · dentedPHX - DURING SCHEDULED D-CHECK, FOUND FUSELAGE SKIN PANEL AT BS 197 TO 203, STRINGER 26-27R DENTED. REPAIRED PER SRM. (M)SDR ASAA0010189Frame · crackedPHX - DURING SCHEDULED D-CHECK, FOUND FRAME AT BS 480, STRINGER 21-22R CRACKED. REPAIRED FRAME PER SRM. (M)SDR ASAA0010185Battery Pack · dischargedSEA - DURING MAINTENANCE CHECK, FOUND EMERGENCY TRACK LIGHT RECEIVER WILL NOT TEST AT ROW 18. REPLACED BATTERY PACK, LIGHTS TESTED NORMALLY. (M)SDR ASAA0010184Skin · dentedPHX - DURING SCHEDULED D-CHECK, MAINTENANCE FOUND DENT IN EXTERIOR SKIN. REPAIRED DENT PER SRM. (M)SDR 20010112SG059Battery Pack · dischargedANC - DURING MAINTENANCE CHECK, FOUND AFT PALLET EMERGENCY EXIT LIGHTING INOPERATIVE. REPLACED REMOTE ASSEMBLY RECEIVER AND BATTERY PACK. LIGHTS TESTED NORMALLY. REF ASAA0010182. (M)SDR ASAA0010182Receiver · inoperativeANC - DURING MAINTENANCE CHECK, FOUND AFT PALLET EMERGENCY EXIT LIGHTING INOPERATIVE. REPLACED REMOTE ASSEMBLY RECEIVER AND BATTERY PACK. LIGHTS TESTED NORMALLY. (M)SDR ASAA0010179Receiver · inoperativeANC - DURING MAINTENANCE CHECK, FOUND SECTION OF EMERGENCY EXIT TRACK LIGHTING WILL NOT SHUT OFF. REPLACED TRACK LIGHT REMOTE ASSEMBLY RECEIVER FOR INOPERATIVE SECTION. SECTION OPERATED NORMALLY. (M)SDR 20010112SG053Battery Pack · dischargedSEA - DURING MAINTENANCE CHECK, FOUND ROW 12 RECEIVER WILL NOT PASS EMERGENCY EXIT LIGHT TEST. REMOVED AND REPLACED ASSY RECEIVER AND BATTERY PACK, OPS NORMAL. (M)REF ASAA0010178.SDR ASAA0010178Receiver · inoperativeSEA - DURING MAINTENANCE CHECK, FOUND ROW 12 RECEIVER WILL NOT PASS EMERGENCY EXIT LIGHT TEST. REPLACED REMOVE ASSY RECEIVER AND BATTERY PACK, OPS NORMAL. (M)SDR ASAA0010177Battery Pack · dischargedSEA - DURING MAINTENANCE CHECK, FOUND AFT ENTRY EMERGENCY ESCAPE LIGHTS INOPERATIVE. REPLACED BATTERY PACK, OPS NORMAL. (M)SDR ASAA0010176Receiver · inoperativeANC - DURING MAINTENANCE CHECK, FOUND FLOOR EMERGENCY EXIT LIGHTS ON SEAT PALLET 5-8 WILL NOT EXTINGUISH. REPLACED REMOTE ASSY RECEIVER, OPS NORMAL. (M)SDR 20010112SG054Power Supply · inoperativeANC - DURING MAINTENANCE CHECK, FOUND EMERGENCY EXIT LIGHTS ON SEAT PALLET 8-2 WOULD NOT EXTINGUISH AND L2 AND R2 EXTERIOR ESCAPE LIGHTS WERE INOPERATIVE. REMOVED AND REPLACED BATERY PACK ON SEAT PALLET 8-2, OPS NORMAL, AND REPLACED POWER SUPPLY TO L2 AND R2 SDR ASAA0010175Battery Pack · dischargedANC - DURING MAINTENANCE CHECK, FOUND EMERGENCY EXIT LIGHTS ON SEAT PALLET 8-2 WOULD NOT EXTINGUISH AND L2 AND R2 EXTERIOR ESCAPE LIGHTS WERE INOPERATIVE. REMOVED AND REPLACED BATERY PACK ON SEAT PALLET 8-2, OPS NORMAL, AND REPLACED POWER SUPPLY TO L2 AND R2 SDR ASAA0010172Receiver · failedSEA-DURING MAINTENANCE CHECK FOUND EMERGENCY EXIT LIGHTS AT ROWS 2 AND 6 WOULD NOT TEST. REPLACED REMOTE ASSEMBLY RECEIVER AT ROW 2 AND REMOTE ASSEMBLY BATTERY AT ROW 6. LIGHTS TESTED NORMALLY.SDR ASAA0010171Battery Pack · dischargedSEA-DURING MAINTENANCE CHECK FOUND EMERGENCY EXIT LIGHTS AT ROW 8 WILL NOT EXTINGUISH. REPLACED BATTERY PACK. LIGHTS WORKED PROPERLY.SDR ASAA0010169Battery Pack · dischargedSEA - DURING MAINTENANCE CHECK, FOUND EMERGENCY TRACK LIGHTS AT ROWS 2 AND 3 INOPERATIVE. REPLACED BATTERY PACK, LIGHTS OPERATED NORMALLY. (M)SDR ASAA0010168Battery Pack · dischargedSEA - DURING MAINTENANCE CHECK, EMERGENCY EXIT LIGHTS AT ROW 16 WOULD NOT TEST. REPLACED BATTERY PACK, LIGHTS OPERATED NORMALLY. (M)SDR ASAA0010164Guide · bentDURING MAINTENANCE CHECK FOUND L1 DOOR GUST LOCK VERY STIFF.REPLACED GUIDE ARM AND ADJUSTED PER MM 52-11-00, DOOR OPERATED NORMALLY.SDR ASAA0010165Battery · dischargedSEA-DURING MAINTENANCE CHECK FOUND SMOKE BARRIER AND AFT SEAT PALLET EMERGENCY EXIT LIGHTS INOPERATIVE.REPLACED AFT SEAT PALLET AND SMOKE BARRIER REMOTE ASSEMBLY BATTERY. LIGHTS TESTED NORMAL.SDR ASAA0010156Heater · overheatedANC - DURING MAINTENANCE CHECK, NOTICED SMOKE AND ELECTRICAL BURNING SMELL IN AFT CABIN. FOUND WIRING FOR POTABLE WATER HEATER JUST ABOVE TANK OVERHEATED. REINSTALLED HEAT TAPES PER EO 1-38-10-01E AND CONNECTED HEAT TAPE WIRING TO AIRCRAFT PER EO 1-38-10-01 SDR ASAA0010153Battery · inoperativeSEA-DURING MAINTENANCE CHECK FOUND SMOKE BARRIER EMERGENCY EXIT LIGHT INOPERATIVE. REPLACED SMOKE BARRIER EMERGENCY EXIT LIGHT BATTERY AND LIGHTS OPERATED NORMALLY.SDR ASAA0010150Battery Pack · inoperativeSEA-DURING MAINTENANCE CHECK FOUNT AFT SERVICE DOORS EXTERIOR EMERGENCY EXIT LIGHTS INOPERATIVE. REPLACED EMERGENCY EXIT LIGHTS BATTERY PACK FOR AFT SERVICE DOORS AND THE LIGHTS OPERATED NORMAL.SDR ASAA0010148Light · inoperativeANC-DURING MX CHECK EMERGENCY LIGHTS ON SEAT PALLET 7-7 WOULD NOT ILLUMINATE. REPLACED EMERGENCY LIGHT RECEIVER ASSY.SDR ASAA0010138Charger · inoperativeYXD-DURING SERVICE CHECK THE RT OVERWING INTERIOR LOWER EMERGENCY EXIT LIGHT WAS FOUND TO BE INOPERATIVE. RELEASED PER MEL 33-15A. SEA MAINTENANCE SUBSEQUENTLY REPLACED BATTERY CHARGER AND REPAIRED SHORTED WIRE. THE LIGHT OPERATED NORMALLY.SDR ASAA0010137Shear Tie · missingYXD-DURING SCHEDULED MAINTENANCE STA 500B FRAME SHEAR TIE MISSING BETWEEN STRINGER 4R AND 13R. REPAIRED PER BOEING DRAWING 65-64958 REV. D.SDR ASAA0010135Door Frame · crackedYXD-DURING SCHEDULED MAINTENANCE STA 480 FRAME WAS FOUND TO BE CRACKED THROUGH THE OUTBOARD FLANGE TERMINATING IN A FASTENER HOLE COMMON TO THE REINFORCEMENT STIFFNER VERTICAL LEG. REPAIRED PER EA 5310-01719.SDR ASAA0010136Shear Tie · missingYXD-DURING SCHEDULED MAINTENANCE STA 480 FRAME SHEAR TIE MISSING BETWEEN STRINGER 4R AND 10R. REPAIRED PER BOEING DRAWING 65-46532.SDR ASAA0010133Sign · inoperativeANC DURING MAINTENANCE CHECK THE EMERGENCY EXIT SIGN ON THE SMOKE BARRIER AND THE EMERGENCY EXIT FLOOR TRACK LIGHTS AT ROW 8 WERE FOUND TO BE INOPERATIVE. REPLACED BOTH BATTERY PACKS AND ALL LIGHTS OPERATED NORMALLY.SDR ASAA0010130Battery · dischargedANC - PRIOR TO FLT 20, THE EXIT TO REAR EXIT LIGHT ON THE SMOKE BARRIER WAS FLASHING. REPLACED BATTERY AND LIGHT OPERATED NORMALLY. (M)SDR 20010111SG007Receiver · inoperativeSEA - DURING MAINTENANCE CHECK, THE EMERGENCY EXIT LIGHT BATTERY PACK AND RECEIVER WERE FOUND TO BE INOPERATIVE. REPLACED THE RECEIVER AND BATTERY PACK, LIGHTS OPERATED NORMALLY. REF ASAA0010128. (M)SDR ASAA0010128Battery Pack · dischargedSEA - DURING MAINTENANCE CHECK, THE EMERGENCY EXIT LIGHT BATTERY PACK AND RECEIVER WERE FOUND TO BE INOPERATIVE. REPLACED THE RECEIVER AND BATTERY PACK, LIGHTS OPERATED NORMALLY. (M)SDR ASAA0010125Battery Pack · dischargedSEA - DURING MAINTENANCE CHECK, THE EMERGENCY TRACK LIGHTING AT ROWS 10/11 AND 16/17 WERE FOUND TO BE INOPERATIVE. REPLACED BATTERY PACKS AND THE LIGHTS OPERATED NORMALLY. (M)SDR ASAA0010118Wire · disconnectedANC - DURING MAINTENANCE CHECK, TWO EMERGENCY TRACK LIGHTS WERE FOUND TO BE INOPERATIVE AT ROW 16. REPLACED WIRING AND LIGHTS OPERATED NORMALLY. (M)SDR ASAA0010111Battery · dischargedANC - PRIOR TO FLT 42, THE EMERGENCY EXIT FLOOR TRACK LIGHTS ON PALLET 5-12 WERE FOUND TO BE INOPERATIVE. REPLACED BATTERY AND LIGHTS OPERATED NORMALLY. (M)
Back to Boeing 737-290C