Boeing 737-290C
Service difficulty reports · 1,409
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '737290C' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '737290C' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR ASAA9510109Battery Pack · dischargedANC - DURING MAINTENANCE CHECK, THE SMOKE BARRIER EMERGENCY EXIT LIGHT WAS FOUND INOPERATIVE. REPLACED THE BATTERY PACK AND LIGHTS OPERATED NORMALLY. (M)SDR ASAA9510108Battery Pack · dischargedSEA - DURING MAINTENANCE CHECK, THE INTERIOR OVERWING EMERGENCY EXIT LIGHTS WERE FOUND INOPERATIVE. REPLACED THE BATTERY PACK AND LIGHTS OPERATED NORMALLY. (M)SDR ASAA9510097Battery Pack · dischargedSEA - DURING MAINTENANCE CHECK, THE EMERGENCY EXIT FLOOR TRACK LIGHTS AT ROWS 14 AND 15 REMAINED ILLUMINATED. REPLACED BATTERY PACK AND LIGHTS OPERATED NORMALLY. (X)SDR ASAA9510090Eel Battery Pack · dischargedSEA - FLT NR 340 - CREW REPORTED THE WHITE EMERGENCY EXIT FLOOR TRACK LIGHTS AT ROW 8 REMAINED ILLUMINATED. REPLACED BATTERY PACK AND LIGHTS OPERATED NORMALLY. (M)SDR ASAA9510089Eel Switch · failedANC - DURING MAINTENANCE CHECK, THE AFT FLIGHT ATTENDANT EMERGENCY EXIT LIGHT SWITCH FAILED. REPLACED SWITCH AND LIGHTS OPERATED NORMALLY. (M)SDR ASAA9510087Eel Batt Pack · dischargedANC - DURING MAINTENANCE CHECK, THE INTERIOR OVERWING EMERGENCY EXIT LIGHTS FLASHED ON AND OFF WHEN ACTIVATED. REPLACED BATTERY PACK AND LIGHTS OPERATED NORMALLY. (M)SDR ASAA9510086Oven · defectiveANC - ON ARRIVAL OF FLIGHT 58, CREW REPORTED A STRONG ELECTRICAL ODOR EMINATED FROM OVEN IN FORWARD GALLEY WHILE IN USE. ODOR DISSIPATED WHEN GALLEY POWER TURNED OFF. REMOVED AND REPLACED DOUBLE OVEN IN NR 1 GALLEY AND OPERATED NORMALLY WITH NO ODORS NOTED. SDR ASAA9510083Eel Battery · dischargedJNU - DURING MAINTENANCE CHECK, THE EMERGENCY EXIT FLOOR TRACK LIGHTS AT ROWS 17 AND 18 WERE FOUND INOPERATIVE. REPLACED BATTERY AND LIGHTS OPERATED NORMALLY. (M)SDR ASAA9510076Eel Battery Pack · dischargedSEA - DURING MAINTENANCE CHECK, THE EMERGENCY EXIT FLOOR TRACK LIGHTS WERE FOUND INOPERATIVE AT ROW 17. REPLACED BATTERY PACK AND LIGHTS NORMALLY. (M)SDR ASAA9510072Eel Assy · defectiveANC - DURING MAINTENANCE CHECK, THE SMOKE BARRIER 'EXIT TO REAR' LIGHT WAS FOUND INOPERATIVE. REPLACED LIGHT ASSY AND LIGHT OPERATED NORMALLY. (M)SDR ASAA9510071Eel Battery · dischargedSEA - DURING MAINTENANCE CHECK, THE BULKHEAD EMERGENCY EXIT LIGHT WAS FOUND INOPERATIVE. REPLACED BATTERY AND LIGHT OPERATED NORMALLY. (M)SDR ASAA9510070Floor Beam · corrodedSEA- DURING C-CHECK, CORROSION WAS FOUND ON THE UPPER FORWARD FLANGE OF THE FLOOR BEAM AT BS 520, RBL 9.50, 15.375 AND 20. PERFORMED INTERIM REPAIR PER EA 5310-01371 AND BOEING TELEX ASA-SEA-95-0440RR. (M)SDR ASAA9510069Floorbeam · corrodedSEA - DURING C-CHECK, CORROSION WAS FOUND ON THE UPPER FORWARD FLANGE OF THE FLOORBEAM AT BS 727B AT LBL 4.00. PERFORMED INTERIM REPAIR PER EA 5310-01365 AND BOEING TELEX ASA-SEA 950429RR. (W)SDR ASAA9510068Floorbeam · corrodedSEA - DURING C-CHECK, CORROSION WAS FOUND ON THE UPPER CHORD FLANGE OF THE FLOORBEAM AT BS 328 BETWEEN RBL 14.5 TO 60. PERFORMED INTERIM REPAIR PER EA 5310-1367 AND BOEING TELEX ASA-SEA 95-0438RR. (W)SDR ASAA9510067Governor · defectiveSEA - DURING C-CHECK, THE AFT AIRSTAIR FAILED THE EMERGENCY EXTENSION TIME CHECK. REPLACED CENTRIFUGAL GOVERNOR AND OPERATED WITHIN EMERGENCY EXTENSION TIME LIMITS. (W)SDR ASAA9510065Eel Battery · dischargedSEA - DURING MAINTENANCE CHECK, THE SMOKE BARRIER EMERGENCY EXIT LIGHT WAS FOUND INOPERATIVE. REPLACED BATTERY AND LIGHT OPERATED NORMALLY. (W)SDR ASAA9510063Eel Batt Pack · dischargedSEA - DURING MAINTENANCE CHECK, THE MID CABIN EMERGENCY EXIT FLOOR TRACK LIGHTS WERE FOUND INOPERATIVE. REPLACED BATTERY PACK AND LIGHTS OPERATED NORMALLY. (M)SDR ASAA9510062Eel Battery · dischargedSEA - DURING MAINTENANCE CHECK, THE FORWARD BULKHEAD EMERGENCY EXIT LIGHT WAS FOUND INOPERATIVE. REPLACED BATTERY AND LIGHT OPERATED NORMALLY. (M)SDR ASAA9510060Door Seal · missingANC - FLT NR 126 - CREW REPORTED LOSS OF PRESSURIZATION DURING CRUISE, PASSENGER OXYGEN MASKS AUTOMATICALLY DEPLOYED. CREW DESCENDED AIRCRAFT TO 10,000 FEET AND SUBSEQUENTLY LANDED WITHOUT INCIDENT. FOUND A LARGE SECTION OF THE AFT LOWER CARGO DOOR SEAL MISSSDR ASAA9510058Eel Battery Pack · dischargedSEA - DURING MAINTENANCE CHECK, THE BULKHEAD EMERGENCY EXIT LIGHT WAS FOUND INOPERATIVE. REPLACED BATTERY PACK AND LIGHT OPERATED NORMALLY. (M)SDR ASAA9510057Eel Battery Pack · dischargedSEA - DURING MAINTENANCE CHECK, THE EMERGENCY EXIT FLOOR TRACK LIGHT TRANSMITTER ON THE PALLET MOD WAS FOUND INOPERATIVE. REPLACED BATTERY PACK AND LIGHT OPERATED NORMALLY. (M)SDR ASAA9510056Eel Battery Pack · dischargedSEA - DURING MAINTENANCE CHECK, THE EMERGENCY EXIT LIGHTS AT ROW 14 WERE FOUND ON AND REMAINED ON AFTER RESETTING. REPLACED BATTERY PACK AND LIGHTS OPERATED NORMALLY. (M)SDR ASAA9510049Eel Battery Pack · dischargedANC - DURING MAINTENANCE CHECK, THE SEAT PALLET EMERGENCY EXIT FLOOR TRACK LIGHTS WERE FOUND INOPERATIVE. REPLACED BATTERY PACK AND LIGHTS OPERATED NORMALLY. (M)SDR ASAA9510048Eel Transmitter · inoperativeANC - DURING MAINTENANCE CHECK, THE EMERGENCY EXIT FLOOR TRACK LIGHTS CYCLED ON AND OFF. REPLACED FORWARD EMERGENCY EXIT FLOOR TRACK LIGHT TRANSMITTER AND LIGHTS OPERATED NORMALLY. (M)SDR ASAA9510047Eel Battery Pack · dischargedSEA - DURING D-CHECK, THE AFT EMERGENCY EXIT EVACUATION SLIDE LIGHTS WERE FOUND INOPERATIVE. REPAIRED CHAFED WIRING AND REPLACED BATTERY PACK, SLIDE LIGHTS ILLUMINATED NORMALLY. (M)SDR ASAA9510046Guide Bracket · misalignedSEA - DURING D-CHECK TEST HOP, CREW REPORTED THE NOSE LANDING GEAR FELL TO THE DOWN POSITION WHEN GEAR HANDLE WAS PLACED TO THE 'OFF' POSITION. RECYCLED GEAR SEVERAL TIMES AND OPERATED NORMALLY. REPOSITIONED NOSE LANDING GEAR LOCK ACTUATOR HYDRAULIC LINE GUISDR ASAA9510045Floorbeam · corrodedSEA - DURING D-CHECK, CORROSION WAS FOUND ON THE FWD LOWER FLANGE OF THE FLOORBEAM AT BS 420 LBL 6 TO LBL 39. REPAIRED PER EA 5310-01338 AND BOEING TELEX ASA-SEA-95-0274RR. (Z)SDR ASAA9510044Floorbeam · corrodedSEA - DURING D-CHECK, CORROSION WAS FOUND ON THE FLOORBEAM TOP FLANGE AT BS 947, LBL 24 TO LBL 56. REPAIRED PER EA 5310-0146 AND BOEING TELEX ASA-SEA-95-0230RR. (Z)SDR ASAA9510042Floorbeam · corrodedSEA - DURING D-CHECK, CORROSION WAS FOUND ON THE LOWER FWD FLANGE AT BS 787, RBL 3 TO RBL 58.5. REPAIRED PER EA 5310-01335 AND BOEING TELEX ASA-SEA-95-0187RR. (Z)SDR ASAA9510039Attach Lugs · corrodedSEA - DURING D-CHECK, CORROSION WAS FOUND ON THE FACES AND IN THE INTERNAL DIAMETER OF THE HORIZONTAL STABILIZER ATTACHMENT LUGS. REPAIRED PER EA 5510-01029 AND BOEING SB 737-55-1055. (Z)SDR ASAA9510041Floorbeam · corrodedSEA - DURING D-CHECK, CORROSION WAS FOUND ON THE LOWER FWD AND AFT FLANGE, CONCENTRATED IN THE FASTENER HOLES AT BS 500, BL 0.0 TO LBL 50. REPAIRED PER EA 5310-01342 AND BOEING TELEX ASA-SEA-95-0223RR. (Z)SDR ASAA9510040Floorbeam · corrodedSEA - DURING D-CHECK, CORROSION WAS FOUND ON THE LOWER FWD FLANGE AT BS 787, LBL 3 TO LBL 50. REPAIRED PER EA 5310-01351 AND BOEING TELEX ASA-SEA-95-0210RR. (Z)SDR ASAA9510035Floorbeam · corrodedSEA - DURING D-CHECK, CORROSION WAS FOUND ON THE UPPER CHORD FWD FLANGE AT RBL 31.75 ON THE FLOORBEAM AT BS 747. REPAIRED PER EA 5310-01356 AND BOEING TELEX ASA-SEA-95-0249RR. (Z)SDR ASAA9510034Sill Web · corrodedSEA - DURING D-CHECK, THE LOWER SILL WEB WAS REMOVED AND FOUR RIVETS COMMON TO THE FITTING AND WEB COULD NOT BE RE-INSTALLED WITHOUT TAKING THE LATCH SUPPORT FITTING OUT. REPAIRED AND REPLACED MAIN CARGO DOOR SILL WEB PER EA 5310-01350 AND BOEING TELEX ASA-SESDR ASAA9510033Floorbeam · corrodedSEA - DURING D-CHECK, CORROSION WAS FOUND ON THE LOWER CHORD FWD FLANGE OF THE FLOORBEAM AT BS 460 BETWEEN LBL 10 AND LBL 31. REPAIRED PER EA 5310-01344 AND BOEING TELEX ASA-SEA-95-0179RR. (Z)SDR ASAA9510032Eel Battery Pack · dischargedSEA - DURING MAINTENANCE CHECK, THE EMERGENCY EXIT FLOOR TRACK LIGHTS WERE FOUND INOPERATIVE AT ROWS 6 AND 7. REPLACED BATTERY BACK AND LIGHTS OPERATED NORMALLY. (W)SDR ASAA9510031Floorbeam · corrodedSEA - DURING D-CHECK, CORROSION WAS FOUND ON THE BOTTOM SURFACE OF THE LOWER FWD FLANGE OF THE FLOORBEAM AT BS 767 BETWEEN RBL 26 AND RBL 44. REPAIRED PER EA 5310-01336 AND BOEING TELEX ASA-SEA-95-018RR. (Z)SDR ASAA9510030Floorbeam · corrodedSEA - DURING D-CHECK, CORROSION WAS FOUND ON THE UPPER FWD AND AFT FLANGE OF FLOORBEAM 767, RBL 24 TO RBL 45. REPAIRED PER EA 5310-01349 AND BOEING TELEX ASA-SEA-95-0197RR. (Z)SDR ASAA9510029Floorbeam · corrodedSEA - DURING D-CHECK, CORROSION WAS FOUND ON THE LOWER FWD FLANGE BETWEEN RBL 24.5 AND RBL 44.5 OF FLOORBEAM BS 747. REPAIRED PER EA 5310-01339 AND BOEING TELEX ASA-SEA-95-0186RR. (Z)SDR ASAA9510028Floorbeam · corrodedSEA - DURING D-CHECK, CORROSION WAS FOUND ON THE UPPER FWD AND AFT FLANGE OF FLOORBEAM BS 500A, RBL 9 TO RBL 42. REPAIRED PER EA 5310-01352 AND BOEING TELEX ASA-SEA-95-0196RR. (Z)SDR ASAA9510027Floorbeam · corrodedSEA - DURING D-CHECK, CORROSION WAS FOUND ON THE BOTTOM SURFACE OF THE LOWER FWD FLANGE OF THE FLOORBEAM AT BS 847, RBL 26 TO RBL 61. REPAIRED PER EA 5310-01337 AND BOEING TELEX ASA-SEA-95-019RR. (Z)SDR ASAA9510026Floorbeam · corrodedSEA - DURING D-CHECK, CORROSION WAS FOUND ON THE HORIZONTAL FLANGE AT LBL 6.2 AND RBL 6.2 OF THE UPPER ANGLE CHORD OF THE FLOORBEAM AT BS 259 BETWEEN RBL 10 AND LBL 10. REMOVED CORROSION PER EA 5310-01348 AND BOEING TELEX ASA-SEA-95-0224RR. (Z)SDR ASAA9510025Keel Beam · damagedSEA - DURING D-CHECK, FASTENERS WERE FOUND TO BE PULLING THROUGH A REPAIR STRAP ON THE LOWER SKIN OF THE KEEL BEAM BETWEEN BS 661 AND 726. REPAIRED PER EA 5330-01187 AND BOEING TELEX ASA-SEA-94--0146RR. (Z)SDR ASAA9510024Floorbeam · corrodedSEA - DURING D-CHECK, CORROSION WAS FOUND AT A FASTENER HOLE ON THE UPPER CHORD FWD FLANGE OF THE FLOORBEAM AT BS 420 LBL 50. REMOVED CORROSION PER EA 5310-01341 AND BOEING TELEX ASA-SEA-95-0204RR. (Z)SDR ASAA9510023Floorbeam · corrodedSEA - DURING D-CHECK, CORROSION WAS FOUND IN THE FASTENER HOLES OF THE UPPER FWD AND AFT FLANGE OF THE FLOORBEAM AT BS 807, LBL 22 AND 27. REMOVED CORROSION PER EA 5310-01343 AND BOEING TELEX ASA-SEA-95-0199RR. (Z)SDR ASAA9510018Eel Housing Rcvr · inoperativeSEA - DURING MAINTENANCE CHECK, TWO EMERGENCY EXIT FLOOR TRACK LIGHTS AT ROW 16 WERE FOUND INOPERATIVE. REPLACED FLOOR PROXIMITY LIGHT HOUSING RECEIVER ASSEMBLY AND LIGHTS OPERATED NORMALLY. (W)SDR ASAA9510017Eel Battery · dischargedSEA - DURING MAINTENANCE CHECK, THE EMERGENCY TRACK LIGHTS WERE FOUND INOPERATIVE ON THE FIRST PALLET. REPLACED BATTERY AND LIGHTS OPERATED NORMALLY. (W)SDR ASAA9510013Eel Assy · inoperativeANC - DURING MAINTENANCE CHECK, THE BULKHEAD EMERGENCY EXIT LIGHT WAS FOUND INOPERATIVE. REPLACED LIGHT ASSEMBLY AND OPERATED NORMALLY. (W)SDR ASAA9510009Rod · out of adjustSEA - FLT 61 - PRIOR TO DEPARTURE, THE CREW REPORTED L1 DOOR WAS DIFFICULT TO CLOSE. ADJUSTED UPPER DOOR HINGE ROD AND DOOR OPERATED NORMALLY. (W)SDR ASAA9510003Eel Batt Pack · dischargedSEA - DURING MAINTENANCE CHECK, THE AFT EXTERIOR EMERGENCY EXIT LIGHTS WERE FOUND INOPERATIVE AT THE L2 AND R2 DOORS. REPLACED BATTERY PACK AND LIGHTS OPERATED NORMALLY. (W)
Back to Boeing 737-290C