Boeing 737-2Q8C
Service difficulty reports · 295
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '7372Q8C' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '7372Q8C' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR ASAA0140618Door Frame · corrodedPAE - DURING C-CHECK, FOUND CORROSION AT FORWARD CARGO DOOR END FRAME 15 INCHES TO 34 INCHES FROM FORWARD EDGE. REPLACED IAW SRM. (M)SDR ASAA0140619Angle · crackedPAE - DURING C-CHECK, FOUND FORWARD CARGO DOOR LOWER FRAME WEB OUTER SKIN ANGLE AT LOWER FORWARD DOOR STAY FITTING CRACKED. REPLACES WEB IAW EA. (M)SDR ASAA0140620Stringer Clip · corrodedPAE - DURING C-CHECK, FOUND CORROSION ON STRINGER CLIP AT BS 986.5 AND STRINGER 27R. REPLACED CLIP AND STRINGER IAW SRM. (M)SDR ASAA0140600Frame · dentedPAE - DURING C-CHECK, FOUND FRAME DENT AT STATION 500 BETWEEN STRINGER 24R AND STRINGER 25R. REPAIRED IAW SRM. (M)SDR ASAA0140601Frame · dentedPAE - DURING C-CHECK, FOUND FRAME DENT AT BS 500A BETWEEN STRINGER 24R AND 25R. REPAIRED IAW ENGINEERING REPAIR. (M)SDR ASAA0140602Frame · dentedPAE - DURING C-CHECK, FOUND FRAME DENT AT BS 500A BETWEEN STRINGER 24L AND 25L. REPAIRED IAW ENGINEERING REPAIR. (M)SDR ASAA0140603Stringer · corrodedPAE - DURING C-CHECK, FOUND CORROSION ON STRINGER 26R AND STATION 419. REPAIRED PER SRM. (M)SDR ASAA0140604Shear Tie · corrodedPAE -DURING C-CHECK FOUND CORROSION ON SHEAR TIE STATION 520 BETWEEN STRINGER 26L AND 27L. REPAIRED IAW SRM. (M)SDR ASAA0140605Stringer · corrodedPAE - DURING C-CHECK, FOUND CORROSION ON STRINGER 27R AT STATION 531. REPAIRED IAW SRM. (M)SDR ASAA0140621Threshold · corrodedPAE - DURING C-CHECK, FOUND CORROSION ON MAIN CARGO DOOR THRESHOLD WEB AT STATION 400-497. REMOVED AND REPLACED DAMAGED SECTION OF WEB PER SRM AND ENGINEERING REPAIR. (M)SDR ASAA0110595Tie · corrodedPAE - DURING SCHEDULED C-CHECK, FOUND STRINGER TIE AT BODY STATION 727A, STRINGER 27L CORRODED. REPAIRED PER SRM. (M)SDR ASAA0110594Stringer · corrodedPAE - DURING SCHEDULED C-CHECK, FOUND STRINGER 27R AT BODY STATION 531-533, CORRODED. REPAIRED PER SRM. (M)SDR ASAA0110576Receiver · inoperativeANC - DURING SCHEDULED MAINTENANCE CHECK, FOUND FLOOR TRACK LIGHTING AT SEAT PALLET 9 INOPERATIVE. REMOVED AND REPLACED REMOTE ASSEMBLY RECEIVER THEN LIGHTS TESTED NORMAL. (M)SDR ASAA0110572Guide · out of adjANC - DURING MAINTENANCE CHECK, FOUND L1 DOOR DIFFICULT TO CLOSE. ADJUSTED GUIDE ARM AND DOOR OPERATED NORMALLY. (M)SDR 2001F00668Receiver · defectiveANC - DURING MAINTENANCE CHECK, FOUND EMERGENCY EXIT LIGHTS AT ROW 11 WERE SLOW TO RESPOND AND WOULD NOT EXTINGUISH. REMOVED AND REPLACED BATTERY PACK P/N 8821004, AND REMOTE ASSEMBLY RECEIVER P/N 883200312, THEN LIGHTS TESTED NORMAL. REF ASAA0110571 (M)SDR ASAA0110571Battery Pack · dischargedANC - DURING MAINTENANCE CHECK, FOUND EMERGENCY EXIT LIGHTS AT ROW 11 WERE SLOW TO RESPOND AND WOULD NOT EXTINGUISH. REMOVED AND REPLACED BATTERY PACK P/N 8821004, AND REMOTE ASSEMBLY RECEIVER P/N 883200312, THEN LIGHTS TESTED NORMAL. (M)SDR 2001F00250Battery · dischargedSEA - DURING MAINTENANCE CHECK, FOUND EMERGENCY EXIT LIGHTS ON SEAT PALLET 10-3 AND SMOKE BARRIER WOULD NOT TEST. REMOVED AND REPLACED BATTERY PACK AND REMOTE ASSEMBLY BATTERY, THEN LIGHTS TESTED NORMAL. (M)SDR ASAA0110365Battery Pack · dischargedSEA - DURING MAINTENANCE CHECK, FOUND EMERGENCY EXIT LIGHTS ON SEAT PALLET 10-3 AND SMOKE BARRIER WOULD NOT TEST. REMOVED AND REPLACED BATTERY PACK AND REMOTE ASSEMBLY BATTERY, THEN LIGHTS TESTED NORMAL. (M)SDR ASAA0110219Battery · dischargedSEA - DURING MAINTENANCE CHECK, FOUND EMERGENCY TRACK LIGHTS AND EXIT LIGHTS ON THE SMOKE BARRIER WOULD NOT TEST AFTER AIRCRAFT RECONFIGURATION. REMOVED AND REPLACED REMOTE ASSEMBLY BATTERIES ON THE SMOKE BARRIER AND THE AFT MOST SEAT PALLET, THEN LIGHTS OPERSDR ASA2001F00000Battery · dischargedSEA - DURING MAINTENANCE CHECK, FOUND EMERGENCY TRACK LIGHTS INOPERATIVE ON SEAT PALLET 9-4, ROW 16. REMOVED AND REPLACED REMOTE ASSEMBLY BATTERY AND RECEIVER, THEN LIGHTS TESTED NORMAL. REF ASAA0110208. (M)SDR ASAA0110208Receiver · inoperativeSEA - DURING MAINTENANCE CHECK, FOUND EMERGENCY TRACK LIGHTS INOPERATIVE ON SEAT PALLET 9-4, ROW 16. REMOVED AND REPLACED REMOTE ASSEMBLY BATTERY AND RECEIVER, THEN LIGHTS TESTED NORMAL. (M)SDR ASAA0110120Control Handle · dirtyANC - AFTER DEPARTURE FROM ANC ON FLIGHT 45, THE LEFT MAIN GEAR FELL BACK DOWN BUT RETRACTED WHEN GEAR LEVER CYCLED BACK UP. FOUND GEAR HANDLE SHAFT DIRTY AND GUMMED UP. WHEN PULLED OUT IT WOULD NOT DROP INTO DETENTS. CLEANED HANDLE SHAFT AND LUBED, HANDLE SDR ASAA0110095Battery · dischargedSEA - DURING MAINTENANCE CHECK, FOUND AFT EMERGENCY EXIT IDENTIFIER INOPERATIVE. REMOVED AND REPLACED REMOTE ASSEMBLY BATTERY AND SIGN WORKED NORMALLY. (M)SDR 20010329SG003Battery · dischargedSEA - DURING MAINTENANCE CHECK, FOUND EMERGENCY EXIT LIGHT ON SMOKE BARRIER WILL NOT TEST. REPLACED BATTERY AND RECEIVER, LIGHT OPERATED NORMAL. (M)SDR ASAA0110048Receiver · inoperativeSEA - DURING MAINTENANCE CHECK, FOUND EMERGENCY EXIT LIGHT ON SMOKE BARRIER WILL NOT TEST. REPLACED BATTERY AND RECEIVER, LIGHT OPERATED NORMAL. (M)SDR ASAA0110030Battery · dischargedSEA - DURING MAINTENANCE CHECK, FOUND SMOKE BARRIER EMERGENCY EXIT LIGHT FAILS TEST. REPLACED SMOKE BARRIER EMERGENCY EXIT BATTERY, LIGHTS THEN TESTED NORMAL. (M)SDR ASAA0010186Skin · mismarkedYXD - DURING SCHEDULED MAINTENANCE, FOUND SKIN PANEL INSTALLED AT TIME OF MANUFACTURE, AT BODY STATION 727-908, STRINGER 14R-20R WAS INCORRECT PART NUMBER. (M)SDR ASAA0010173Sill · crackedYXD - DURING HEAVY MAINTENANCE, FOUND LOWER CARGO DOOR SILL CRACKED AT STATION 368, WATERLINE 208. REPAIRED PER EA 5310-01888. (M)SDR ASAA0010167Hinge · lack of lubeANC - DURING MAINTENANCE CHECK, FOUND L2 DOOR HARD TO OPEN. LUBED HINGES, DOOR OPERATED NORMALLY. (M)SDR ASAA0010151Actuator · malfunctionedOTX-DURING FLIGHT 151 OME TO OTZ, CREW REPORTED NOSE GEAR FREE FALLS DOWN WHEN THE GEAR HANDLE PLACED IN OFF POSITION. CONTINUED FLIGHT TO OTZ, LANDED WITHOUT INCIDENT. A/C INSPECTED AND FERRIED TO ANC FOR REPAIRS, LANDED WITHOUT INCIDENT. SERVICED NOSE STRUT,SDR ASAA0010146Latch · lack of lubeANC-PRIOR TO FLIGHT 22 THE L1 DOOR WOULD NOT CLOSE. INSPECTED DOOR LATCHES FOR PROPER ALIGNMENT, CHECKS NORMAL. LUBRICATED LATCHES AND ROLLERS. THE L1 DOOR OPERATED NORMALLY.SDR 20001121SH007Transmitter · inoperativeSEA - AFTER RECONFIGURATION OF THE AIRCRAFT, THE EMERGENCY EXIT LIGHTS FAILED CHECK. REPLACED BATTERY PACKS AND MID-TRANSMITTER, LIGHTS OPERATED NORMALLY. REF: OPER CNTRL NR ASAA010132. (X)SDR ASAA0010132Battery Pack · dischargedSEA - AFTER RECONFIGURATION OF THE AIRCRAFT, THE EMERGENCY EXIT LIGHTS FAILED CHECK. REPLACED BATTERY PACKS AND MID-TRANSMITTER, LIGHTS OPERATED NORMALLY. REF: OPER CNTRL NR 20001121SH007. (X)SDR 20010111SG006Receiver · inoperativeSEA - DURING MAINTENANCE CHECK, THE EMERGENCY EXIT LIGHTS AT ROWS 12, 18 AND SMOKE BARRIER DID NOT TEST PROPERLY. REPLACED BATTERY FOR SMOKE BARRIER AND ROW 18. REPLACED RECEIVER FOR ROW 12. ALL LIGHTS OPERATED NORMALLY. (M)SDR ASAA0010129Battery · dischargedSEA - DURING MAINTENANCE CHECK, THE EMERGENCY EXIT LIGHTS AT ROWS 12, 18 AND SMOKE BARRIER DID NOT TEST PROPERLY. REPLACED BATTERY FOR SMOKE BARRIER AND ROW 18. REPLACED RECEIVER FOR ROW 12. ALL LIGHTS OPERATED NORMALLY. (M)SDR ASAA0010126Guide · frozenSEA - PRIOR TO FLIGHT 61, THE L1 DOOR WAS FOUND TO BE HARD TO CLOSE. REPLACED THE GUIDE ARM AND ADJUSTED, DOOR OPERATED NORMALLY. (M)SDR ASAA0010122Battery · dischargedANC - PRIOR TO FLIGHT 20, THE EMERGENCY FLOOR LIGHTING ILLUMINATED AT ROW 14. REPLACED BATTERY AND LIGHTS OPERATED NORMALLY. (M)SDR ASAA0010120Snubber · inoperativeANC - PRIOR TO FLIGHT 148, THE L1 DOOR WAS DIFFICULT TO CLOSE. REPLACED SNUBBER AND DOOR OPERATED NORMALLY. (M)SDR ASAA0010114Frame · damagedPAE - DURING C-CHECK, THE UPPER FUSELAGE FRAME STATION 480, STRINGER 5R, RBL 28, HOLES WERE FOUND TO HAVE SHORT EDGE MARGIN. REPAIRED PER EM 5310-01719. (M)SDR ASAA0010115Frame · crackedPAE - DURING C-CHECK, THE AFT VERTICAL BULKHEAD BS 727 LEFT OUTBOARD CHORD CRACKED. REPAIRED PER EM 5310-01380. (M)SDR ASAA0010116Bracket · damagedPAE - DURING C-CHECK, THE MAIN CARGO DOOR LATCH ACTUATOR MOUNTING BRACKET FASTENERS WERE PULLED THROUGH THE SKIN AT BS 430, WL 228. REPAIRED PER BFG ENGINEERING REPAIR NR 00-0860P3. (M)SDR ASAA0010117Skin · dentedPAE - DURING C-CHECK, A DENT WAS FOUND IN THE FUSELAGE SKIN AT BS 338, STRINGER 17L, BELOW THE FORWARD ENTRY DOOR. REPAIRED PER BFG ENGINEERING REPAIR NR 00-0887PB, BAC SRM. (M)SDR ASAA0010121Doubler · crackedPAE - DURING SCHEDULED C-CHECK, A CRACK WAS FOUND IN THE BEARSTRAP AT THE FORWARD UPPER CORNER OF THE MAIN CARGO DOOR CUTOUT. REPAIRED PER BFG ENGINEERING REPAIR NR 00-0903P3 AND BOEING TELEX BFG-PAN-00-01150H. (M)SDR ASAA0010100Battery · dischargedSEA - DURING MAINTENANCE CHECK, THE EMERGENCY EXIT IDENTIFIER WAS FOUND TO BE INOPERATIVE. REPLACED BATTERY AND THE EMERGENCY EXIT IDENTIFIER OPERATED NORMALLY. (M)SDR 20001103AP001Receiver · inoperativeSEA - DURING MAINTENANCE CHECK, THE EMERGENCY EXIT TRACK LIGHTS AT ROWS 2, 3 AND 14 WOULD NOT TEST. REPLACED BATTERIES AT ROWS 2 AND 14. REPLACED RECEIVER AT ROW 3, ALL LIGHTS OPERATED NORMALLY. REF ASAA0010078.(M)SDR ASAA0010078Battery · dischargedSEA - DURING MAINTENANCE CHECK, THE EMERGENCY EXIT TRACK LIGHTS AT ROWS 2, 3, AND 14 WOULD NOT TEST. REPLACED BATTERIES AT ROWS 2 AND 14. REPLACED RECEIVER AT ROW 3, ALL LIGHTS OPERATED NORMALLY. (M)SDR ASAA0010075Battery Pack · dischargedSEA - DURING MAINTENANCE CHECK, THE EMERGENCY EXIT TRACK LIGHTS AT ROWS 12 WILL NOT TEST PROPERLY. REPLACED BATTERY PACK AND LIGHTS OPERATED NORMALLY. (M)SDR ASAA0010055Light · inoperativeSEA - DURING MAINTENANCE CHECK, THE R2 DOOR OVERHEAD EMERGENCY EXIT LIGHT WAS FOUND TO BE INOPERATIVE. REPLACED LIGHT ASSEMBLY AND LIGHT OPERATED NORMALLY. (M)SDR ASAA0010045Light · malfunctionedSEA - DURING MAINTENANCE CHECK, THE R2 DOOR EMERGENCY EXIT IDENTIFIER WAS FOUND TO BE DIM. REPLACED LIGHTS ASSEMBLY AND LIGHT OPERATED NORMALLY. (M)SDR ASAA0010028Battery Pack · dischargedSEA - DURING MAINTENANCE CHECK, THE EMERGENCY EXIT TRACK LIGHTS AT ROW 27 REMAINED ILLUMINATED. REPLACED BATTERY PACK AND LIGHTS OPERATED NORMALLY. (M)
Back to Boeing 737-2Q8C