What was found
SEA - DURING MAINTENANCE CHECK, FOUND EMERGENCY EXIT LIGHTS ON SEAT PALLET 10-3 AND SMOKE BARRIER WOULD NOT TEST. REMOVED AND REPLACED BATTERY PACK AND REMOTE ASSEMBLY BATTERY, THEN LIGHTS TESTED NORMAL. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
SEA - DURING MAINTENANCE CHECK, FOUND EMERGENCY EXIT LIGHTS ON SEAT PALLET 10-3 AND SMOKE BARRIER WOULD NOT TEST. REMOVED AND REPLACED BATTERY PACK AND REMOTE ASSEMBLY BATTERY, THEN LIGHTS TESTED NORMAL. (M)