SDR UALA2009031000501Apu · defectiveGLYCOL SMELL IN CABIN. RTFL. REPLACED COALESCER BAGS, FOUND RT BAG CONTAMINATED WITH OIL. FOUND APU WITH NO OIL. A/C OUT FOR A PACK BURNOUT. APU INOP NEEDS A NEW APU NONE ON STATION. WILL MAKE READY TO FLY WITH APU INOP. REMOVED OLD APU AND REPLACED WITFeb 16, 2009 · N372UA · Boeing 737322 · APU Core EngineSDR UALA2009021700501Apu · defectiveGLYCOL SMELL IN CABIN. RTFL. REPLACED COALESCER BAGS, FOUND RT BAG CONTAMINATED WITH OIL. FOUND APU WITH NO OIL. A/C OUT FOR A PACK BURNOUT. APU INOP NEEDS A NEW APU NONE ON STATION. WILL MAKE READY TO FLY WITH APU INOP.Feb 16, 2009 · N372UA · Boeing 737322 · APU Core EngineSDR UALA2009020900423Power Strip · damagedAFT GALLEY FLOOR EEL LIGHT INOP AND DAMAGED. REPLACED DAMAGED POWER STRIP.Feb 8, 2009 · N348UA · Boeing 737322 · Light System WiringSDR UALA2009020200352Pin · brokenAFT END OF EEL STRIP IS BROKEN. REPLACED AFT MOST EEL STRIP BY AFT GALLEY CARTS. FOUND BROKEN PINS ON CONNECTOR. CHECKS GOOD.Jan 31, 2009 · N327UA · Boeing 737322 · Light System WiringSDR UALA2009020200342Fitting · crackedTHE 1 LT MED SURROUND STA 360 FRAME CLIP IS CRACKED. REPAIR WAS ACP PER UA-EVA-72282 AS A INTERIM REPAIR.Jan 30, 2009 · N339UA · Boeing 737322 · Passenger/Crew DoorsSDR UALA2009012900310Power Supply · inoperativeFWD ENTRY DOOR (1L) EMERGENCY EXIT LIGHTS IN THE INTERIOR DOOR SURROUND AREA INOP. REPLACED BATTERY POWER SUPPLY M1133.Jan 28, 2009 · N367UA · Boeing 737322 · Emergency LightingSDR UALA2009012200249Switch · defectiveMCP PANEL - F/O'S RED\FIRE WARN BELL CUTOUT\ LIGHT-SWITCH WILL NOT SILENCE A FIRE WARNNG. REPLACED NR 2 FIRE WARNING BELL CUTOUT SWITCH.Jan 22, 2009 · N330UA · Boeing 737322 · Fire DetectionSDR UALA2009012100232Skin · crackedFUSELAGE SKIN CRACKED AT RT AFT ENTRY DOOR LOWER HINGE CUTOUT, FWD LOWER CORNER. MAJOR REPAIR ACCOMPLISHED. STARTED INSTALLING DOUBLER REPAIR. REPAIRED CRACKED SKIN AT DOOR 2R.Jan 20, 2009 · N373UA · Boeing 737322 · Fuselage Main, Plate/SkinSDR UALA2009012100231Skin · dentedCREW REPORTS DENT ON FUSELAGE APPROX 5FT AFT OF DOOR 1L. CUT OUT CREASED DAMAGE. ROLLED UP NEW DOUBLER MATERIAL, STARTED MFG DOUBLER REPAIR. ACCOMPLISHED PERMANENT REPAIR REF SRM 53-00-01 REPAIR 31, ACCOMPLISHED ON BASE WU S5458I.Jan 20, 2009 · N334UA · Boeing 737322 · Fuselage Main, Plate/SkinSDR UALA2009012200240Skin · crackedDOOR 1R LWR AFT CORNER CRACK IN SKIN. MAJOR REPAIR ACCOMPLISHED. HFEC INSPECTION OF SUSPECTED SURFACE AREA, SHOWS INDICATION OF DEFECT OR CRACK. ACCOMPLISHED TEXAS PATCH REPAIR PER UA-EVA-72270 A. NR K6656G BY 306593 AND INSPECTED BY LC10. TO BE REINSPECTEJan 18, 2009 · N367UA · Boeing 737322 · Passenger/Crew DoorsSDR UALA2009011900195Battery Pack · dischargedFLOOR EEL LIGHTS INOP FOR SEAT 3 TO SEAT 9. REPLACED BATTERY PACK. TESTS OKAY.Jan 17, 2009 · N350UA · Boeing 737322 · Emergency LightingSDR UALA2009011500166Warning System · inoperativeCREW REPORTS ON FIRE TEST GET NO FIRE BELL. HANDLE LIGHTS AND REMAINDER OF FIRE TEST NORMAL. REPLACED AURAL WARNING MODULE.Jan 14, 2009 · N371UA · Boeing 737322 · Fire DetectionSDR UALA2009031000081Lamp · inoperativeLT OVERWING EXIT LIGHT INOP RELAMPED, OPS CHECK OK.Jan 8, 2009 · N351UA · Boeing 737322 · Emergency LightingSDR UALA2009010800081Light · inoperativeLT OVERWING EXIT LIGHT INOP. RELAMPED, OPS CHECK OKAY.Jan 8, 2009 · N351UA · Boeing 737322 · Emergency LightingSDR UALA2009031000063Bulb · inoperativeRT AFT DOOR EXTERIOR EMERGENCY LIGHT INOP. FOUND BULB NOT COMPLETELY INSTALLED IN SOCKET. INSTALLED BULB, OPS CK GOOD.Jan 5, 2009 · N385UA · Boeing 737322 · Emergency LightingSDR UALA2009010600063Bulb · inoperativeRH AFT DOOR EXTERIOR EMERGENCY LIGHT INOP. SUPPLEMENTAL DATA UPDATE FOUND BULB NOT COMPLETELY INSTALLED IN SOCKET. INSTALLED BULB, OPS CK GOOD.Jan 5, 2009 · N385UA · Boeing 737322 · Emergency LightingSDR UALA2009010500057Rod · bentRT WING OTBD FLAP TRACK TO AFT FLAP ROD DISCONNECTED AND BENT. REPLACED ROD.Jan 5, 2009 · N350UA · Boeing 737322 · Trailing Edge FlapsSDR UALA2009010500058Fseu · failedTE FLAP DISAGREE EICAS MSG AND FLAPS HUNG UP AT POS 1 WITH FLAP HANDLE UP AFTER LANDING. R&R FLAP-SLAT ELECTRONIC UNIT. OPS CHECKED OKAY.Jan 4, 2009 · N668UA · Boeing 737322 · Trailing Edge Flap Control SystemSDR UALA2009010200001Feeder Cable · dirtyROW 15 TO BACK OF ACFT EEL LIGHTS ARE VERY DIM. CLEANED AND SECURED WALL FEEDER CABLE. OPS CHECK OK.Dec 31, 2008 · N339UA · Boeing 737322 · Light System WiringSDR UALA2008121106856Flap · delaminatedLT WING OUTBOARD AFT FLAP TRAILING EDGE HAS 6 INCH AREA OF DELAMINATION AND DISBONDING ON INBOARD SIDE. OUTSIDE OF SRM LIMITS. FLAP IS REPAIRED.Dec 11, 2008 · N329UA · Boeing 737322 · Trailing Edge FlapsSDR UALA2008121106843Radio · malfunctionedRADIO PROBLEM. RTFL.Dec 11, 2008 · N386UA · Boeing 737322 · Communications SystemSDR UALA2008120906823Skin · damagedDAMAGE TO ACFT BELOW & AFT OF DOOR 1L. DIMENSIONS 2.6 FT BY 4 INCHES WIDE RUNNING ALONG STRINGER, 15 INCHES BELOW LAP JOINT. MAJOR REPAIR ACCOMPLISHED. NO STRINGER DAMAGE. CUT OUT DAMAGED SKIN. DOUBLERS DRILLED, TRIMMING COUNTER SINK HOLES & PRIME. ALL PDec 9, 2008 · N381UA · Boeing 737322 · Fuselage Main, Plate/SkinSDR UALA2008112606680Control Panel · faultyNO GREEN LIGHT NR 2 ENG LIGHT BOTTLE. REPLACED FIRE CONTROL PANEL.Nov 25, 2008 · N348UA · Boeing 737322 · Extinguishing SystemSDR UALA2008112106612Skin · dentedFUSELAGE DENTED FROM STA 850-930 UP TO 0.125 DEEP. MAJOR REPAIR ACCOMPLISHED. INSTALLED DOUBLER REPAIR.Nov 21, 2008 · N329UA · Boeing 737322 · Fuselage Main, Plate/SkinSDR UALA2008111706525Light · looseEMERGENCY FLOOR LIGHTS LOOSE NEAR ROW 6 ABC. SECURED EMERGENCY LIGHTS.Nov 14, 2008 · N327UA · Boeing 737322 · Emergency LightingSDR COOSDR080231Intercostal · crackedUPPER FUSELAGE PAX CABIN BETWEEN STA 294.5 AND STA 303.9 AT S-16L INTERCOSTAL CRACKED. (K)Nov 13, 2008 · N672RY · Boeing 737322 · Fuselage Miscellaneous StructureSDR COOSDR080232Intercostal · crackedUPPER FUSELAGE PAX CABIN BETWEEN STA 294.5 AND STA 030.9 AT S-12L INTERCOSTAL CRACKED. (K)Nov 13, 2008 · N672RY · Boeing 737322 · Fuselage Miscellaneous StructureSDR COOSDR080233Intercostal · crackedUPPER FUSELAGE PAX CABIN AT STA 300 AND ABOVE S10L INTERCOSTAL CRACKED. (K)Nov 13, 2008 · N672RY · Boeing 737322 · Fuselage Miscellaneous StructureSDR COOSDR080234Stringer · crackedUPPER FUSELAGE PAX CABIN AT STA 296.5, S10L CRACKED. (K)Nov 13, 2008 · N672RY · Boeing 737322 · Fuselage Main, Longeron/StringerSDR 2008UALA06486Oxygen System · leakingCREW O2 LEAK.Nov 10, 2008 · N365UA · Boeing 737322 · Crew Oxygen SystemSDR 2008UALA06478Flashlight · inoperativeFWD F/A FLASHLIGHT NOT BLINKING. REPLACED FLASHLIGHT.Nov 10, 2008 · N370UA · Boeing 737322 · Emergency EquipmentSDR 2008UALA06363Bottle · low pressureLOW BOTTLE. RUPTURE DISK HAS SLOW LEAK. REMOVED & REPLACED RUPTURE DISK.Nov 4, 2008 · N381UA · Boeing 737322 · Escape SlideSDR UALA2008111306367Lamp · burned outENG 2 FIRE LIGHT DID NOT LIGHT UP. RELAMPED. ALSO REPLACED PIT DETECTOR PANEL. CK'D OK.Nov 3, 2008 · N366UA · Boeing 737322 · Fire DetectionSDR 2008UALA06367Light · inoperativeENG 2 FIRE LIGHT DID NOT LIGHT UP. RELAMPED FIRE LIGHT, ALSO REPLACED PIT DETECTOR PANEL. CHECKED OKAY.Nov 3, 2008 · N366UA · Boeing 737322 · Fire DetectionSDR 2008UALA06366Control Panel · defectiveCARGO FIRE LIGHT DID NOT LIGHT UP. SUSPECT FAULTY FIRE CONTROL PANEL. REPLACED CARGO FIRE CONTROL PANEL CHECKD OKAY. AC OK FOR SERVICE.Nov 3, 2008 · N366UA · Boeing 737322 · Fire DetectionSDR 2008UALA06311Fire Bottle · faultyCARGO FIRE DETECT BOTH BOTTLES ARMED LIGHTS INOP, NO TEST. REPLACE 2 EA FIRE BOTTLES. REPLACE METERING VLV. REPLACE DIVERTER VALVE. REPLACE 2 EA LINE FILTERS. INSTALL 2 SQUIBS IN EXTINGUISHER BOTTLES. TEST OK. Oct 28, 2008 · N203UA · Boeing 737322 · Fire Bottle, FixedSDR 2008UALA06260Sliding Window · crackedCAPTAINS L2- SLIDING WINDOW CRACKED AT TOP OF DESCENT. REPLACED SLIDING WINDOW. TROUBLESHOT WINDOW HEAT. FOUND NO POWER TO THE WINDOW. FOUND AND CORRECTED MIS-WIRED CAPTAIN'S SLIDER WINDOW. CORRECTED PER WD.30-41-00. OPS NORMAL.Oct 24, 2008 · N328UA · Boeing 737322 · Flight Compartment WindowsSDR 2008UALA06252Battery Pack · inoperativeEEL LIGHTS OUT FROM ROW 15 BACK. SUSPECT FAULTY POWER STRIP AND POWER PACK. REPLACED POWER STRIP AND BATTERY PACK OP CHECKED GOOD. ACFT OK FOR SERVICE. Oct 22, 2008 · N311UA · Boeing 737322 · Emergency LightingSDR 2008UALA06237Light · inoperativeAFT SECTION OF EMERGENCY LIGHTS INOP. REPLACED LIGHT ASSEMBLY OP CHECKED GOOD. ACFT OK FOR SERVICE.Oct 22, 2008 · N340UA · Boeing 737322 · Emergency LightingSDR 2008UALA06213Skin · delaminatedRT OUTBOARD TRAILING EDGE FLAP OUTBOARD LOWER SURFACE DELAMINATED APPROX 72 SQ INCHES. REPLACED DAMAGED OUTBOARD AFT FLAP ON RT WING. OP CHECKED GOOD. ACFT OK FOR SERVICE. Oct 21, 2008 · N327UA · Boeing 737322 · Trailing Edge FlapsSDR 2008UALA06201Light · inoperativeLEFT OVERWING SLIDE EEL LIGHT INOP. RELAMPED, OPS CHECK OKAY.Oct 21, 2008 · N347UA · Boeing 737322 · Emergency LightingSDR 2008UALA06200Connector · looseEMERGENCY EXIT LIGHT STRIP HAS SEGMENT THAT DOES NOT ILLUMINATE BY 2B AND STRIP BY AFT GALLEY BROKEN. SECURED LOOSE CONNECTIONS AT LIGHT STRIPS. BOTH TEST NORMAL. ACFT OK FOR SERVICE.Oct 21, 2008 · N314UA · Boeing 737322 · Light System WiringSDR 2008UALA06241Connector · looseEMERGENCY EXIT FLOOR LIGHTING AT AFT TWO ROWS LOOSE. TROUBLESHOT AND RE-SECURED LOOSE CONNECTION ON EMERGENCY LIGHT STRIP. ALL OPS NORMAL. ACFT OK FOR SERVICE. Oct 20, 2008 · N348UA · Boeing 737322 · Light System WiringSDR UALA2008111306087Uplock Sensor · faultyLT MLG UNSAFE "RED" LIGHT ILLUMINATED. RTFL FOUND SENSOR S72 GROUND WIRE OPEN. REPLACED S72 UP AND LOCKED SAFETY SENSOR. RESISTANCE CK'D GOOD. INSPECTED SENSOR INSTALLATION. ACCMP GEAR EXT RETRACT TEST. TEST OK FOR SERVICE.Oct 13, 2008 · N346UA · Boeing 737322 · Landing Gear Position and WarningSDR 2008UALA06087Sensor · defectiveLEFT MLG UNSAFE "RED" LIGHT ILLUMINATED. RTFL. FOUND SENSOR S72 GROUND WIRE OPEN AND REPLACED SENSOR. RESISTANCE CK'D GOOD. INSPECTED SENSOR INSTALLATION. ACCMP GEAR EXT RETRACT TEST. Oct 13, 2008 · N346UA · Boeing 737322 · Landing Gear Position and WarningSDR 2008UALA06072Power Strip · defectiveAFT CABIN SECTION EEL FLOOR LIGHTS INOP. REPLACED POWER FEEDER CABLE TO EEL STRIP.Oct 12, 2008 · N340UA · Boeing 737322 · Light System WiringSDR 2008UALA06071Power Strip · damagedFIRST CLASS SECTION EEL FLOOR LIGHTS INOP. REPAIRED POWER FEEDER CABLE STRIP.Oct 12, 2008 · N340UA · Boeing 737322 · Light System WiringSDR 2008UALA06067Connector · dirtyEMERGENCY LIGHTS OUT FROM ROW 15 BACK. CLEANED LIGHT CONNECTORS. CHECKED GOOD.Oct 11, 2008 · N311UA · Boeing 737322 · Light System WiringSDR 2008UALA06017Fire Bottle · low pressureAPU FIRE BOTTLE PRESSURE BELOW LIMIT. REPLACED APU FIRE BOTTLE.Oct 6, 2008 · N346UA · Boeing 737322 · Fire Bottle, FixedSDR 2008UALA06009Door Frame · crackedFWD RIGHT GALLEY DOOR OPENING CRACKED AT AFT LOWER CORNER. INSTALLED DOUBLER REPAIR AT AFT LWR CORNER OF FWD RT GALLEY DOOR OPENING.Oct 5, 2008 · N338UA · Boeing 737322 · Fuselage Main, Structure
Back to Boeing 737-322