Boeing 737-322
Service difficulty reports · 4,751
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '737322' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '737322' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR 2008UALA06002Door Frame · crackedDOOR 1R CUTOUT HAS A 2 INCH CRACK THRU FASTENER AT LOWER AFT CORNER. INSTALLED DOUBLER REPAIR.
SDR 2008UALA06218Blower · malfunctionedSTRONG ELECTRICAL ODOR IN FWD PART OF AIRCRAFT. REPLACED NORM EXHAUST BLOWER. OPS CHECKS NORMAL.SDR 2008UALA05985Blower · vibrationRAMP REPORTS, STRONG VIBRATION FWD CABIN AND LOUDER IN THE FWD CARGO COMP. NOISE AND VIBRATION STOPPED WHEN NORMAL EXHAUST FAN C/B POPPED. NOW HAVE STRONG ELECTRICAL ODOR IN FWD PART OF AIRCRAFT. REPLACED NORM EXHAUST BLOWER. OPS CHECKS NORMAL.SDR UALA2008111305931Indicator · unknownABORTED T/O AT 100 KNOTS. ACCOUNT OF FLAG IN VIEW ON F/O'S AIRSPEED INDICATOR. CHECKED PER AMM05-51-07. BRAKE TEMP COOLED 54 MINUTES PER FIG 201. BRAKE TEMP RETURNED TO NORMAL, NO DAMAGE TO BRAKES.SDR 2008UALA05931Indicator · malfunctionedABORTED T/O AT AROUND 100 KTS AT 110K LBS, ACCOUNT OF FLAG IN VIEW ON F/O'S AIRSPEED INDICATOR.SDR 2008UALA05905Slide · out of positionDOOR 1R SLIDE GAUGE NOT VISIBLE. FOUND SLIDE IN PACK MISALIGNED. REMOVED SLIDE, REALIGNED SLIDE IN PACK SO GAUGE VISIBLE. REINSTALLED SLIDE. OK FOR SERVICE.
SDR 2008UALA05899Fuse · inoperativeEXTERIOR EMERGENCY EXIT LIGHT INOP AT DOOR 2R. FOUND BLOWN FUSE ON POWER SUPPLY. REPLACED AT DOOR 2R. OP CHECKS NORMAL.SDR 2008UALA05898Lamp · inoperativeAFT 15 FT OF CABIN FLOOR MOUNTED EMERGENCY ESCAPE PATH LIGHTING IS INOP. REMOVED, DRIED & REINSTALLED AFT THREE LAMPS. OP CHKS NORMAL.
SDR 2008UALA05893Light · inoperativeFWD 1 FT SECTION OF CABIN FLOOR MOUNTED EMERGENCY ESCAPE PATH LIGHTING IS INOP. REPLACED SECTION OF EMERGENCY LIGHT. OP CHECKS GOOD.SDR 2008UALA05889Fire Loop · faultyAPU FIRE BELL & HANDLE ILLUMINATE DURING TEST. APU FIRE DETECTOR FOUND FAULTY. REPLACED APU TAILPIPE OVERHEAT FIRE LOOP. APU FIRE DETECTION SYSTEM OPS CHECKS GOOD.SDR 2008UALA05819Light · disconnectedEMERGENCY LIGHT INOPERATIVE AT SEAT ROW 20A. FOUND SINGLE ELEMENT AT SEAT ROW 20A DISCONNECTED. RECONNECTED. OP CHECK GOOD.SDR 2008UALA05844Light · looseEMERGENCY ESCAPE PATH LIGHTING IS LOOSE IN THE AFT SECTION OF ECONOMY CLASS. REMOVED AND REPLACED UPPER & LOWER EEL TRACK AND COVER. EEL LIGHTS OP CHECK OKAY.SDR 2008UALA05785Wedge · debondedFOUND LEFT INBD MID FLAP TRAILING EDGE WEDGE DISBONDED BETWEEN THE WEDGE AND ATTACH CHANNEL. GAP BETWEEN TRAILING EDGE WEDGE OF MID FLAP AND LEADING EDGE OF AFT FLAP IS OUT OF LIMITS. REMOVED T/E WEDGE & ADJUSTED GAP. REPLACED MID FLAP WEDGE. REPLACED INBD TESDR 2008UALA05720Control Panel · faultyAFTER REPLACEMENT OF NR 2 CARGO FIRE BOTTLE, SQUIB ACTIVATED WHEN CIRCUIT BREAKER PUSHED BACK IN. FIRE BOTTLE AND SQUIB WILL REQUIRE REPLACEMENT. CONSTANT .5 VOLTS AT SQUIB CONNECTOR D9497 BETWEEN PIN 1 AND PIN 2. REPLACED CARGO FIRE CONTROL PANEL, NR 2 FIRSDR 2008UALA05719Connector · underservicedF/O SIDE OXYGEN MASK COMM CONNECTOR DISCONNECTED. REPAIRED O2 BOX CONNECTOR.SDR 2008UALA05699Switch · defectiveFOUND EMERGENCY LIGHT TOGGLE SWITCH ON P5 PANEL TO BE DEFECTIVE, MISSING PLUNGER FOR MICRO SWITCH IN CIRCUIT FOR NOT ARMED LIGHT WITH SWITCH IN OFF POSITION. INSTALLED NEW SWITCH ON THE P5 PANEL.SDR 2008UALA06216Slide · malfunctionedDOOR 1L PARTIAL SLIDE DEPLOYMENT. REMOVED SLIDE AND CONTAINER FROM L1 DOOR. INSTALLED NEW SLIDE.SDR 2008UALA06222Fan · faultyCREW REPORT: ALT EQUIP COOLING FAN INTERMITTENT AT FL250 SAMC TEXT: PACKS AND CABIN PRESSURIZATION NORMAL, ALT EQUIP COOLING EXHAUST FAN 'OFF' LIGHT FLICKERING ON INTERMITTANTLY. FOUND EXHAUST DUCT FORWARD OF MUFFLER CLOGGED WITH DUST AND DIRT RESTRICTING ESDR 2008UALA05632Transceiver · faultyFIRST OBSERVERS OXYGEN MASK WILL NOT TRANSMIT WITH MASK ON. FOUND NR 3 TRANSCEIVER FOUND FAULTY. REPLACED TRANSCEIVER. OP CHECKS OKAY.SDR 2008UALA05638Audio Panel · failedUNABLE TO TRANSMIT ON ANY ACP SELECTIONS FROM CAPTAIN'S SIDE. RTFL. REPLACED THE CAPT'S ACP AND THE REMOTE ELECTRONICS UNIT.SDR 2008UALA05574Smoke Detector · failedFWD PIT FIRE DETECTOR LOOP -A SHOWS FAILED AND CANNOT BE RESET. FOUND FAULTY SMOKE DETECTOR. REPLACED FWD "A" LOOP FWD PIT SMOKE DETECTOR. OP CHECKS NORMAL. ACFT OK FOR SERVICE.SDR 2008UALA05566Oxygen Bottle · low pressureCREW O2 LOW. FOUND FAULTY O2 BOTTLE SUSPECT FAULTY O-RING. REPLACED O2 BOTTLE. AC OK FOR SERVICE.SDR 2008UALA05562Girt Bar · looseGIRT BAR LOCKS ARE LOOSE AT 2L. FOUND LOOSE GIRT BAR LOCKS. SECURED FLOOR LOCKS OP CHECK GOOD. ACFT OK FOR SERVICE.SDR 2008UALA05555Lamp · inoperativeAFT SECTION OF CABIN FLOOR EMERGENCY LIGHTS INOP. FOUND FAULTY LAMP, REPLACED LAMP. OP CHECK GOOD. ACFT OK FOR SERVICE.
SDR UALA2008111305512B-Nut · looseCREW O2 AT 1550 PSI AND DROPPING. FOUND LOOSE B-NUT. FOUND AND REPAIRED THREE LEAKS ON HIGH PRESS SIDE. REPLACED 90 DEGREE ELBOWS AT BOTH ENDS OF HARD LINE FROM CROSS FITTING TO FILL VALVE. SECURED LEAKING B-NUT AT CROSS FITTING TO STEP DOWN REG SVCED SYSTSDR 2008UALA05512Oxygen Bottle · lowCREW O2 AT 1550 PSI.SDR 2008UALA05525Light · inoperativeEEL LIGHT STRIP FOR SEAT ROWS 1 AND 2 IS INOP. FOUND FAULTY LAMP STRIP. REPLACED EEL STRIP BETWEEN ROW 1 AND 2. OP CKS GOOD. AC OK FOR SERVICE.SDR 2008UALA05514Lamp · inoperativeEMERGENCY LIGHT STRIP FOR SEAT ROWS 1 AND 2 IS INOPERATIVE. FOUND FAULTY LAMP STRIP. REPLACED LAMP STRIP OP CHECK GOOD. AC OK FOR SERVICE.
SDR 2008UALA05513Inverter · faultyEMERGENCY PATH LIGHTING DOES NOT ILLUMINATE THE ENTIRE AIRCRAFT WITH SWITCH IN THE ON POSITION. SUSPECT INVERTER FAULTY. REPLACED INVERTER M1389 REFERENCE AMM 33-51-93. AC OK FOR SERVICE.SDR 2008UALA05526Seat · looseTHE 6 DEF ROW OF SEATS IS LOOSE. SECURED LEG ATTACH POINTS. SEAT IS SECURED.SDR 2008UALA05504Cap · missingEMER LIGHT STRIP END CAP MISSING AT 1B.SDR 2008UALA05488Check Valve · faultyPRESSURIZATION PROBLEM. RTFL. FAULTY CHECK VALVE. REPLACED CHECK VALVE.SDR 2008UALA05476Light · unsecureEMERGENCY LIGHT INOPERATIVE ROW 16 AND AFT. SECURED EMERGENCY LIGHT AND OPS CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA05490Wedge · damagedLT NR 3 SLAT WEDGE HAS DAMAGE. REMOVED NR 3 SLAT, R&R R425 60 TO SHOP AND RE-INSTALLED. INSPECTED INSTALLATION, FOUND OKAY.
SDR 2008UALA05460Feeder Cable · damagedEMERGENCY LIGHTS ARE INOP FROM ROW 16 TO AFT GALLEY. REPLACED WALL FEEDER CABLE. EMERGENCY LIGHT BATTERY NEEDS TO CHARGE TO FINISH OPS CHECK.SDR 2008UALA05428Feeder Cable · damagedAFT GALLEY EEL STRIP INOP. FOUND FEEDER CABLE DAMAGED. REPAIRED FEEDER CABLE. AC OK FOR SERVICE.
SDR 2008UALA05427Lamp · inoperativeEMERGENCY LIGHT LAMP INOP ROW 12. REPLACED LAMP.SDR 2008UALA05426Lamp · inoperativeEMERGENCY LIGHT LAMP INOP ROW 11. REPLACED EMERGENCY LIGHT LAMP.SDR 2008UALA04373Charger · inoperativeFWD OVERHEAD EMERGENCY EXIT SIGN AND 1L EMERGENCY EXIT SIGNS INOP. *S/D* REMOVED & REPLACED BATTERY CHARGER LT FWD.SDR 2008UALA04358Frame · damagedDAMAGE AT FRAME 277 AND STR 24R. *S/D* MAJOR REPAIR ACCOMPLISHED: MFG & INSTALLED REPAIR FILLERS, DOUBLER & TRIPLER.SDR 2008UALA04357Light · inoperativeEXTERIOR EMERGENCY LIGHT AFT OF DOOR 1L IS INOP. *S/D* REPLACED LIGHT ASSEMBLY. OP CHECKS GOOD.SDR 2008UALA04356Power Supply · faultyEMERGENCY EXIT LIGHT OVER DOOR 2L STAY ON WITH LIGHTS OFF. *S/D* REPLACED POWER SUPPLY & BATTERY. CHECKS NORMAL.SDR 2008UALA04345Control Panel · inoperativeCREW REPORT: CARGO FIRE DETECTION SYSTEM INOP. SUPPLEMENTAL DATA UPDATE FOUND FIRE CONTROL PANEL TO BE FAULTY. REPLACED CARGO FIRE CONTROL PANEL PER MM 26-00-02. OPS TEST NORMAL. AC OK FOR SERVICE.SDR 2008UALA04327Connector · contaminatedFLOOR EMERGENCY EXIT LIGHTING INOP ROW 15 AND AFT. FOUND MOISTURE AT FLOOR STRIP CONNECTORS. DRIED AND CLEANED ALL CONNECTORS FROM ROWS 15 AFT. OP CHECKS OKAY.
SDR 2008UALA04284Feeder Cable · damagedEMERGENCY FLOOR MOUNTED STRIP LIGHTING ROWS 15-21 INOP. FOUND POWER FEEDER CABLE TO BE FAUTLTY. REPLACED POWER DISTRIBUTION STRIP AND ALL OPS NORMAL. ACFT OK FOR SERVICE.SDR 2008UALA04270Light · faultyAFT GALLEY EEL LIGHT STRIP NOT WORKING.SDR 2008UALA04266Structure · dentedFUSELAGE ON LEFT SIDE FWD OF ENGINE IS DENTED.SDR 2008UALA04258Lamp · damagedAFT GALLEY EEL LIGHT DAMAGED.SDR 2008UALA04253Coupling · leakingCREW OXYGEN SYSTEM LOW. RECORD PRESSURE PRIOR TO SERVICING. CREW COMMENTS: 1275 PSI AND SLOWLY DECREASING. FOUND THE JUMP SEAT MASK CONNECTION POINT TO ACFT O-RING DAMAGED. REPLACED WITH NEW MASK, OP CHECKED MASK, NORMAL. SERVICED O2 LEVELS. ACFT OK FOR SDR 2008UALA04241Retainer · deformedPRESSURIZATION INDICATION. RTFL. FOUND FOUND ZEE RETAINER ON FO'S SLIDING WINDOW DEFORMED AT LOWER AFT CORNER. STRAIGHTENED RETAINER AND AREA OF DISBOND IS WITHIN LIMITS. INSTALLED SMALL AMOUNT OF SPEED TAPE AT AREA OF DISBOND. PRESSURIZED ACFT AND FOUND NO
Back to Boeing 737-322