Boeing 737-3G7
Service difficulty reports · 5,850
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '7373G7' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '7373G7' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AWXA9700032Floorbeam · corrodedDURING ROUTINE MAINTENANCE CHECK, FOUND CORROSION ON FLOORBEAM UPPER CHORD AT BS 312 RBL 8 WL 208. REMOVED DAMAGED AREA, FABRICATED NEW PART AND INSTALLED PER SRM 53-10-51.SDR AWXA9700031Floorbeam · corrosionDURING ROUTINE MAINTENANCE CHECK, FOUND CORROSION ON UPPER FLANGE OF FLOORBEAM AT BS 194.5 RBL 14 WL 208. REMOVED DAMAGED AREA, FABRICATED NEW UPPER CHORD AND INSTALLED PER SRM 53-10-51.SDR AWXA9700007Wire · brokenDURING ROUTINE MAINTENANCE CHECK, FOUND EMERGENCY FLOOR PROX LIGHT INOP AT SEAT 3C. REPAIRED WIRING, OPS CHECK GOOD BOEING STANDARD.SDR AWXA9700001Slide · malfunctionedAFTER ARRIVING AT GATE, 3RD FLIGHT ATTENDANT DID NOT DISARM DOOR AND AFT ENTRY SLIDE BLEW OUT. REMOVED DEPLOYED SLIDE FROM AIRCRAFT PER 25-61-35. INSPECTED DOOR AREA FOR DAMAGE, NONE FOUND. AIRCRAFT SAFE FOR FERRY FLIGHT. REMOVED AND REPLACED L-2 DOOR SLIDSDR AWXA9600787Skin · dentedDURING ROUTINE MAINTENANCE CHECK, FOUND C-2 DOOR AFT CARGO OUTER SKIN DENTED AND CREASED IN SEVERAL PLACES. REMOVED AND REPLACED C-2 DOOR OUTER SKIN IAW B737, SRM 52-30-01 AND 51-40-02. MAT ID 2024-T3 .071. FABRICATED NEW DOOR SKIN IAW B737 SRM 52-30-01.SDR SWAA961443Coalescer Bag · dirtyINFLIGHT, RIGHT PACK TRIPPED OFF. RESET AND IT TRIPPED AGAIN, REPORTED LIGHT SMOKE. RETURNED TO LAS AND MADE AN UNEVENTFUL LANDING. CHECKED SYSTEM AND AIR CYCLE MACHINE FOR LEAKS, NONE FOUND. REPLACED COALESCER BAGS AND OP CHECKED PER BOEING M/M.SDR AWXA9600781Slide · malfunctionedL-1 DOOR SLIDE BLEW ON OPENING OF DOOR. REMOVED AND REPLACED L-1 DOOR SLIDE PER MM 25-00.SDR SWAA961445Stringer Web · crackedDURING SCHEDULED SERVICE CHECK, FOUND LT STRINGER 18A SHEAR BEAM WEB CRACKED, ORIGINATING FROM AFT END OF WEB TO THE MOST I/B AFT FASTENER HOLE. REPAIRED PER SWA ACO 6580-53.SDR AWXA9600779Wire · disconnectedDURING ROUTINE MAINTENANCE CHECK, FOUND SEAT EMERGENCY LIGHT INOP. REPAIRED BROKEN WIRE, CHECKS GOOD, STC - SA3432NM.SDR AWXA9600776Rudder Pcu · malfunctionedYAW DAMPER IS INTERMITTANT. AIRCRAFT EXPERIENCES NEARLY CONSTANT SLIGHT DUTCH ROLL WITH EXCURIOUS TO MODERATE DUTCH ROLL. REMOVED AND REPLACED RUDDER PCU.SDR AWXA9600775Wire · brokenDURING ROUTINE MAINTENANCE CHECK, FOUND EMERGENCY LIGHT PROBLEM. REPAIRED BROKEN WIRE. OPS CHECK GOOD.SDR SWAA961421Pack · failedINFLIGHT, RT PACK TRIPPED OFF ALONG WITH A SMOKE SMELL. ISOLATED TO RIGHT PACK, LEFT PACK CLEARED SMELL. AIRCRAFT RETURNED TO BNA AND MADE AN UNEVENTFUL LANDING. REPLACED COMPRESSOR DISCHARGE, TURBINE INLET AND DUCT OVERHEAT SENSORS PER BOEING M/M.SDR SWAA961420Pack · failedINFLIGHT, RT PACK TRIPPED OFF, ATTEMPTED TO RESET, NO HELP. TRIPPED AGAIN AND NOTED LIGHT SMOKE. AIRCRAFT RETURNED TO LAS AND MADE AN UNEVENTFUL LANDING. CHECKED SYSTEM FOR LEAKS, RT AIR CYCLE MACHINE, TURBO FAN AND ALL RELATED PACK COMPONENTS AND OPERATED SDR AWXA9600766Light · inoperativeDURING ROUTINE MAINTENANCE CHECK, FOUND SEAT 2B EMERGENCY EXIT LIGHT INOP. REMOVED AND REPLACED SEAT 2B EMERGENCY LIGHT ASSEMBLY, OPS GOOD STC - SA3432NM.SDR AWXA9600735Web · crackedDURING ROUTINE MAINTENANCE CHECK, FOUND CRACK AT THE AFT SIDE OF THE VERTICAL WEB IN THE UPPER CHORD RADIUS ON BS 520, RBL 24.75, WL 207.5. REPAIRED PER RHD 4040, ER 3-53-14-06 AND 81103.SDR AWXA9600732Sill · corrodedDURING ROUTINE MAINTENANCE CHECK, FOUND CORROSION ON MOPSILL BS 913 TO 1006, RBL 55, WL 208. REMOVED DISCREPENT MOPSILL AND INSTALLED REPLACEMENT MOPSILL (P/N 69-68660-2), TSW, SRM 51-30-01 AND 51-40-02.SDR AWXA9600717Wire · looseDURING ROUTINE MAINTENANCE CHECK, FOUND EMERGENCY EXIT LIGHT AT SEAT 19 INOPERATIVE. FOUND WIRE PULLED OUT OF SPLICE. REPAIRED AS NEEDED, OPS CHECK GOOD STC - SA3432NM.SDR AWXA9600716Light · inoperativeDURING ROUTINE MAINTENANCE CHECK, FOUND ROW 17 FLOOR PROXIMITY EMERGENCY LIGHT INOP. REPLACED ROW 17 FLOOR PROXIMITY LIGHT ASSEMBLY, FUNCTION CHECK NORMAL.SDR AWXA9600734Floorbeam · corrodedDURING ROUTINE MAINTENANCE CHECK, FOUND CORROSION ON FLOORBEAM RBL 55 TO LBL 55, WL 208, BS 986.5. REMOVED, FABRICATED UPPER CHORD AND INSTALLED PER SRM 51-41-02 AND ER 3-53-16-15.SDR AWXA9600733Floorbeam · corrodedDURING ROUTINE MAINTENANCE CHECK, FOUND FLOORBEAM BS 967, WL 208, LBL 44 TO 55 CORRODED. INSTALLED REPLACEMENT T-CAP ON FLOORBEAM AND FASTENERS FROM BS 967, WL 208, LBL 44 TO 55 PER SRM 51-40-02.SDR AWXA9600731Web · corrodedDURING ROUTINE MAINTENANCE CHECK, FOUND PRESSURE WEB BS 1016 TO 1032, RBL O TO 38, WL 208 CORRODED OUT OF LIMITS. REMOVED, FABRICATED AND INSTALLED WEB PER SRM 51-40-02, 51-70-13 AND PSR 009.SDR AWXA9600713Wire · shortedDURING ROUTINE MAINTENANCE CHECK, FOUND ROWS 19 TO 22 EMERGENCY TRACK LIGHTS OUT. WIRE HARNESS SHORTED OUT AT SEAT ROW 20. REPAIRED HARNESS, OPERATIONS CHECK GOOD.SDR AWXA9600706Wire · brokenDURING ROUTINE MAINTENANCE CHECK, FOUND ROW 2 TO 5 FLOOR PROXIMITY EMERGENCY LIGHTING INOPERATIVE. REPAIRED BROKEN WIRE, OPERATIONS CHECK GOOD.SDR AWXA9600722Floorbeam · crackedDURING ROUTINE MAINTENANCE CHECK, FOUND BS 520 FLOORBEAM IS CRACKED IN RADIUS AT RBL 24.75. REPAIRED EXPANSION LINK AT STA 520, RBL 15 PER ER 3-53-13-11, TCO-PAN-96-1661RR AND 8110-3.SDR AWXA9600721Mopsill · corrodedDURING ROUTINE MAINTENANCE CHECK, FOUND FWD ENTRY MOPSILL CORRODED BEYOND LIMITS, FWD ENTRY DOOR CUTOUT, WL 108. REMOVED AND REPLACED MOPSILL PER SRM 53-10-15, 51-40-2.SDR AWXA9600723Floorbeam · corrodedDURING ROUTINE MAINTENANCE CHECK, FOUND FLOORBEAM STA 312 IS CORRODED LBL 10 TO LBL 45, WL 208. REMOVED UPPER CHORD OF BEAM FROM RBL 27 TO LBL 55, FABRICATED NEW CHORD AND INSTALLED REPAIR PARTS PER SRM 53-10-51, FIG 205.SDR SWAA961281Slide · low pressDURING SCHEDULED TERMINAL CHECK, FOUND AFT SERVICE DOOR ESCAPE SLIDE PRESSURE LOW. REPLACED PER BOEING M/M.SDR AWXA9600657Wire · disconnectedPHX - FLT 2498 - FOUND EMERGENCY LIGHTS AT SEATS 8, 9, 10 AND 11 INOP. RECONNECTED WIRE AT ROW 10 A, B, C. OPERATIONS CHECK GOOD. (M)SDR AWXA960641Doubler · crackedPAE - FLT 7820 - DURING ROUTINE MAINTENANCE CHECK, FOUND BONDED DOUBLER TO BE CRACKED AT BS 370, BL0, WL 148. REPAIRED PER ER 3-53-33-18. TCO-PAN-96-151 RR 8110-3. (M)SDR AWXA960640Skin · delaminatedPAE - FLT 7820 - DURING ROUTINE MAINTENANCE CHECK, FOUND RIGHT WING OUTBOARD FORE FLAP HAD DELAMINATED DENT ON UPPER SURFACE 36 INCHES OUTBOARD OF INBOARD END. REPAIRED DAMAGED AREA, IAW SRM 51-70-10. (M)SDR AWXA960636Keel Beam · corrodedPAE - FLT 7820 - DURING ROUTINE MAINTENANCE CHECK, FOUND CORROSION ON KEEL BEAM AT BS 5000 D PLUS 2, RBL 4, STRINGER 18, WL 148.5. REPAIRED PER ER 3-53-13-10. TCO-PAN-96-1502RR, FAA FORM 8110-3. (M)SDR AWXA960639Floor Beam · corrodedPAE - FLT 7820 - DURING ROUTINE MAINTENANCE CHECK, FOUND FLOOR BAM STATION 294.5 HAS CORROSION ON UPPER SURFACE AND AROUND FASTENER HOLES, LBL 15 TO RBL 50, WL 208. REMOVED, FABRICATED AND INSTALLED TOP CHORD OF FLOOR BEAM AT BS 294.5, LBL 10 - RBL 65, WL 208SDR AWXA960638Floor Beam · corrodedPAE - FLT 7820 - DURING ROUTINE MAINTENANCE CHECK, FOUND FLOOR BEAM STATION 312 HAS CORROSION ON UPPER SURFACE AND AROUND FASTENER HOLES, RBL 12 TO LBL 17, WL 208. CUT OUT CORRODED AREA OF FLOOR BEAM AND REPAIRED PER SRM 53-10-51. (M)SDR AWXA960637Mopsill · corrodedPAE - FLT 7820 - DURING ROUTINE MAINTENANCE CHECK, FOUND CORROSION ON UPPER SURFACE OF MOPSILL AT FORWARD DOR STATION 306 TO 344, LBL 55, WL 208. REMOVED CORRODED MOPSILL AND REPLACED WITH NEW IAW SRM 53-10-15. (M)SDR AWXA960634Floor Beam · corrodedPAE - FLT 7814 - DURING ROUTINE MAINTENANCE CEHCK, FOUND CORROSION ON FLOOR BEAM UPPER CHORD AT BS 98G5, LBL 21 THROUGH RBL 12, WL 208. REMOVED, FABRICATED AND INSTALLED NEW UPPER CHORD SECTION PER ER 3-53-1590. (M)SDR SWAA961106Light · brokenDURING SCHEDULED 3C1 CHECK, FOUND EMERGENCY LIGHTING AT FWD F/A STATION BROKEN. REPLACED LIGHT ASSEMBLY PER BOEING M/M.SDR AWXA960635Mopsill · corrodedPAE - FLT 7814 - DURING ROUTINE MAINTENANCE CHECK, FOUND CORROSION ON ASD MOPSILL FROM BS 967 TO 99, RBL 47, WL 208. REMOVED AND REPLACED ASD MOPSILL, FROM BS 967 TO 991, RBL 47 IAW SRM 51-30-01 AND 51-40-02. (M)SDR AWXA960633Mopsill · corrodedDURING ROUTINE MAINTENANCE CHECK, FOUND CORROSION ON AED MOPSILL AT BS 957 AND 988 LBL 50, WL 208. INSTALLED AFT ENTRY DOOR MOPSILL IAW SRM 51-40-02. REINSTALLED DRAIN AS PER 51-40-00, 51-30-01. (M)SDR AWXA960581Wire · brokenPHX - FLT 2653 - DURING ROUTINE MAINTENANCE CHECK, FOUND EMERGENCY LIGHTS AT ROW 8 INOP. REPAIRED WIRING. OPS GOOD. (M)SDR AWXA960590Light · loosePHX - FLT 2249 - DURING ROUTINE MAINTENANCE CHECK, FOUND EMERGENCY LIGHT ROW 23 LOOSE FROM SEAT. RESECURED LIGHT. (M)SDR SWAA961073Indicator · inaccurateDIVERTED TO ABQ DUE TO TOTAL FUEL QUANTITY FLUCTUATING, +/- 2,000 LBS. INSPECTED FOR LEAKS AND CHECKED FUEL QUANITITY, DEFERRED NR 2 FUEL TANK INDICATION AND CONTINUED PER MEL 28-6.SDR AWXA960524Wire · brokenPHX - FLT 220 - DURING ROUTINE MAINTENANCE CHECK, FOUND ROW 5 EMERGENCY EXIT LIGHT INOP. SPLICED BROKEN EMERGENCY EXIT LIGHT WIRING AT ROW 5. OPERATIONS CHECK NORMAL. (M)SDR AWXA960523Wire · disconnectedPHX - FLT 2539 - DURING ROUTINE MAINTENANCE CHECK, FOUND EMERGENCY LIGHT BOTTLE CAP MISSING FROM ROW 3 (C). CONNECTED WIRING FOR EMERGENCY LIGHT AT SEAT 3C, F/C GOOD. (M)SDR AWXA960522Battery · dischargedPHX - FLT 1258 - DURING ROUTINE MAINTENANCE CHECK, FOUND INTERIOR EMERGENCY LIGHTS INOP NEAR LEFT EMERGENCY EXIT. REPLACED BATTERY ASSEMBLY FOR THAT AREA. LIGHTS OPS CHECK GOOD. (M)SDR AWXA960445Light · missingPHX - FLT 2205 - DURING ROUTINE MAINTENANCE CHECK, FOUND OVERHEAD BIN EMERGENCY EXIT LIGHT MISSING FROM HOLE ROW 21 LEFT. SECURED LIGHT ASSEMBLY IN BULLNOSE, OPS GOOD. (M)SDR AWXA960439Wire · brokenPHX - FLT 2202 - REFERENCE MEL 33-15, SEAT ROW 6 A, B, C EMERGENCY LIGHTS INOP. REPAIRED BROKEN WIRE AT ROW 6 A, B, C. EMERGENCY LIGHT FUNCTION CHECK, MEL REMOVED. (M)SDR AWXA960401Windshield · bird strikeLAS - FLT 2084 - AIR TURN BACK, BIRD STRIKE AROUND COCKPIT WINDSHIELD AREA ON CLIMB-OUT. EMERGENCY DECLARED. PERFORMED BIRD STRIKE INSPECTION PER CARD AWM 392. NO DAMAGE NOTED. (M)SDR AWXA960412Sill · corrodedPAE - FLT 7821 - DURING ROUTINE SCHEDULED C-8 MAINTENANCE CHECK, FOUND CORROSION ON FWD MOPSIL BS 284 TO BS 332, WL 208, RBL 55. REMOVED AND REPLACED MOPSIL PER SRM 53-10-51. (M)SDR AWXA960394Wires · brokenPHX - FLT 2667 - DURING ROUTINE MAINTENANCE CHECK, FOUND BROKEN WIRES ON FLOOR PROX SYSTEM. REPAIRED WIRING. (M)SDR AWXA960411Floor Beam · corrodedPAE - FLT 7821 - DURING ROUTINE SCHEDULED C-8 MAINTENANCE CHECK, FOUND CORROSION ON FLOOR BEAM AT BS 312, LBL 12, BL 0, RBL 7, WL 208. REMOVED DAMAGE, FABRICATED AND INSTALLED REPAIR PARTS PER SRM 53-10-51. (M)
Back to Boeing 737-3G7