What was found
DURING ROUTINE MAINTENANCE CHECK, FOUND CORROSION ON UPPER FLANGE OF FLOORBEAM AT BS 194.5 RBL 14 WL 208. REMOVED DAMAGED AREA, FABRICATED NEW UPPER CHORD AND INSTALLED PER SRM 53-10-51.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING ROUTINE MAINTENANCE CHECK, FOUND CORROSION ON UPPER FLANGE OF FLOORBEAM AT BS 194.5 RBL 14 WL 208. REMOVED DAMAGED AREA, FABRICATED NEW UPPER CHORD AND INSTALLED PER SRM 53-10-51.