Boeing 737-401
Service difficulty reports · 2,961
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '737401' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '737401' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR USAA070184Stringer Clip · crackedBS 727C S-7R CRACKED. REMOVED CRACKED TIE AND INSTALLED NEW ONE PER SRM 51-10-02, DEFECT SIZE: .25 INCH.SDR USAA070185Stringer Clip · crackedBS 727F S-8R CRACKED. REMOVED CRACKED TIE & INSTALLED NEW ONE PER SRM 51-10-02, DEFECT SIZE: .25 INCH.SDR USAA070186Stringer Clip · crackedBS 727F, S-7R CRACKED. REMOVED CRACKED TIE & INSTALLED NEW ONE PER SRM 51-10-02, DEFECT SIZE: .25 INCH.SDR USAA070187Intercostal · crackedTWO CRACKS, MAIN ENTRY DOOR INTERCOSTAL, BS 348, S-16L. FAB'D & INSTALLED TEE, FILLER & STRAP PER EO E5305V203, DEFECT SIZE: 2 INCHES (2 EA).SDR USAA070188Angle · crackedBS 500G, S-28R CRACKED. REMOVED CRACKED ANGLE & FAB'D & INSTALLED NEW PER SRM 51-10-02, BOEING DWG 6973527, DEFECT SIZE: .5 INCH.SDR USAA070189Stringer Clip · crackedBS 727C, S-4R CRACKED. REMOVED TIE AND INSTALLED NEW ONE PER SRM 51-10-02, DEFECT SIZE: .5 INCH.SDR USAA070190Stringer Clip · crackedBS 727A S-11L STRINGER TO FRAME TIE CLIP CRACKED. FABBED & INSTALLED NEW CLIP PER SRM 51-01-02, BOEING DWG 6977519 , DEFECT SIZE: .25 INCH.SDR USAA070191Frame · crackedSTA 500A, S9L CRACKED. FAB'D & INSTALLED DOUBLER REPAIR PARTS PER TR 53-10-20D, DEFECT SIZE: .50 INCH.SDR SB07021Bottle · low pressurePHL - CREW REPORTED THE RIGHT AFT SERVICE DOOR EMERGENCY ESCAPE SLIDE BOTTLE PRESSURE APPEARS TO BE IN THE RED. MAINTENANCE REMOVED AND REPLACED THE RIGHT AFT SERVICE DOOR EMERGENCY ESCAPE SLIDE PER MM 25-61-35-422-004.SDR SB07020Wire · brokenDCA - MAINTENANCE FOUND THE FLOOR PROXIMITY EMERGENCY LIGHTS AT THE LAST TWO ROWS OF SEATS, LEFT-HAND SIDE, INOPERATIVE. MAINTENANCE REPAIRED WIRING. OPERATIONAL CHECK OF EMERGENCY LIGHTS GOOD.SDR USAA070153Support Angle · corrodedSTA 727D-727E ABOVE S25L, AROUND SCREW HOLES ON SUPPORT ZEE HAVE CORROSION. FOUND CORROSION OUT OF LIMITS, CHANGED ZEE PER SRM 53-60-53, 53-20-01; CORR LEVEL 2; TASK C53-202-01, DEFECT SIZE: .5 INCH.SDR USAA070165Support Angle · corrodedSTA 787 S-27-S26R ON FRAME TO SKIN ATTACH POINT SUPPORT ANGLES HAVE CORROSION. REPLACED SUPPORT ANGLE, TREATED, PRIMED, INSTALLED PER SRM 53-00-01, 53-00-07; CORR TASK C53-202-01, DEFECT SIZE: 1 INCH.SDR USAA070164Intercostal · corrodedSTA 847-867 S26R ON TRANSITION ANGLE HAS CORROSION. REMOVED & INSTALLED NEW INTERCOSTAL PER SRM 53-60-53, 51-10-01, 51-20-01; CORR TASK C53-208-01, DEFECT SIZE: .5 INCH.SDR USAA070163Strap · corrodedSTRAP BETWEEN BS 748-787 HAS CORROSION. FAB'D STRAP PER BOEING DWG 65-47957 & SRM 51-20-01; CORR TASK C53-202-01; LEVEL 2, DEFECT SIZE: 3 X 4 INCHES.SDR USAA070162Cargo Track · corrodedSTA 400-500G AT S26R CARGO TIE DOWN TRACKS. MADE NEW TIE DOWN TRACK, TREATED & PRIMED PER SRM 53-00-53, 53-10-02; CORR TASK C53-202-01, DEFECT SIZE: .5 INCH.SDR USAA070161Attach Angle · corrodedSTA 500G S28I HAS CORROSION. REMOVED ANGLE, FAB'D NEW, TREATED & PRIMED PER SRM 51-10-02; CORR TASK C53-208-01, DEFECT SIZE: 1 INCH.SDR USAA070160Stringer Clip · corrodedSTRINGER CLIP, STA 847 S24R HAS CORROSION. REMOVED & REINSTALLED CLIP PER DWG 65-47960; CORR TASK C53-208-01; LEVEL 2, DEFECT SIZE: 1 INCH.SDR USAA070159Floor Support · corrodedAFT CARGO COMPARTMENT STR 28R HAS CORROSION. REMOVED DAMAGE, INSTALLED REPAIR PARTS PER TR 53-10-06B; CORR TASK C53-208-01, DEFECT SIZE: 3 INCHES.SDR USAA070158Floor Support · corrodedFLOOR SUPPORT, STA 770, LBL 12 HAS CORROSION. TREATED, PRIMED & REINSTALLED NUT PLATES PER TR 53-10-06B, SRM 51-40-02; CORR TASK C53-208-01, DEFECT SIZE: .5 INCH.SDR USAA070157Floor Support · corrodedSTA 770, LBL 16 ON FLOOR SUPPORT HAS CORROSION. INSTALLED NUT PLATES PER TR 53-10-06B, SRM 51-40-02; CORR TASK C53-208-01, DEFECT SIZE: .5 INCH.SDR USAA070156Floor Support · corrodedUNDER SIDE OF FLOOR SUPPORT, STA 770, LBL 23 HAS CORROSION. REINSTALLED REPAIR & NUT PLATES PER TR 53-10-06B, DRM 51-40-02; CORR TASK C53-208-01, DEFECT SIZE: .5 INCH.SDR USAA070154Floorbeam · corrodedSTA 312 LBL 8-0, AROUND NUT PLATES ON FLOORBEAM HAS CORROSION. REMOVED T-CUP, PICKED UP HOLES, TREATED, PRIMED, INSTALLED NUT PLATES PER SRM 53-10-51; CORR TASK C53, DEFECT SIZE: .5 INCHSDR USAA070142Skin · gougedSTA 850-890 STR 2R - 2L, SKIN DEEPLY GOUGED/CHAFED AT FRONT OF DORSAL MOUNT. INSTALLED DOUBLER & TRIPLER PER EA 98446, DEFECT SIZE: 16"L X 1"W X .010"D.SDR USAA070152Angle · corrodedSTA 947-996 HAS CORROSION. REMOVED DAMAGED Z AND INSTALLED NEW PER SRM 51-40-02; CORR LEVEL 2; TASK C53-107-01, DEFECT SIZE: 50 INCHES.SDR USAA070151Floorbeam · corrodedT-CAP SECTION FROM LBL 9-RBL 52, REUSING SPLICES LBL 13-RBL 6, 6 SPOTS CORROSION. REMOVED DAMAGE, INSTALLED CAP PER TR 53-60-01 REV A; CORR LEVEL 2; TASK C53-107-02, DEFECT SIZE: 2 INCHES DIA AT 6 SPOTS.SDR USAA070150Attach Fitting · corrodedSTA 328 LBL 45 HAS CORROSION. REMOVED DAMAGE & INSTALLED FAB'D PARTS PER BOEING DWG 65-45834; CORR LEVEL 1; TASK C53-202-01, DEFECT SIZE: 2 INCHES.SDR USAA070149Support · corrodedSTA 947-967 LBL 25 HAS CORROSION. REMOVED DAMAGE & INSTALLED FAB'D REPAIR PARTS PER SRM 53-60-51; CORR LEVEL 2; TASK C53-107-02, DEFECT SIZE: 20 INCHES.SDR USAA070148Angle · corrodedSTA 727G-767 JUST ABOVE STR 25R HAS CORROSION. REMOVED DAMAGE & INSTALLED REPAIR PARTS PER SRM BAC SPEC 1496-377; CORR LEVEL 2; TASK C53-202-01, DEFECT SIZE: 40 INCHES.SDR USAA070147Angle · corrodedSTA 727D & 727G STR 25R HAS CORROSION. REMOVED DAMAGE & INSTALLED FAB'D PARTS PER SRM BAC SPEC 1496-377; CORR LEVEL 2; TASK C53-202-01, DEFECT SIZE: 10 INCHES.SDR USAA070146Intercostal · corrodedSTA 294.5 - 312, RBL 16 HAS CORROSION. REMOVED DAMAGED PART & INSTALLED NEW PER SRM 53-00-04; CORR LEVEL 1; TASK C53-107-02, DEFECT SIZE: 18 INCHES.SDR USAA070145Doubler · corrodedSTA 500 B-C AT NR 2 ANTENNA DOUBLER HAS CORROSION. REMOVED DOUBLER & INSTALLED FAB'D DOUBLER PER SRM 51-10-02; CORR LEVEL 2; TASK C53-208-01, DEFECT SIZE: 6 INCHES.SDR USAA070144Door Frame · crackedAFT CARGO DOOR FWD SIDE FR STA 795.23 S 22R HAS CRACK. REPLACED DOOR PER IMM 52-31-00-4, DEFECT SIZE: .5 INCH.SDR USAA070143Frame · crackedBS 440 S-24R WL 160 HAS CRACK. REMOVED DAMAGE & INSTALLED FAB'D REPAIR PARTS PER EA 98455, DEFECT SIZE: .250 INCH.SDR USAA070155Floor Support · corrodedFLOOR SUPPORT, STA 770 LBL 6 HAS CORROSION. DRILLED HOLES, TREATED, PRIMED, INSTALLED PLATES PER TR 53-10-06B, SRM 51-40-02, COR TASK C53-208-01, DEFECT SIZE: 1 INCH.SDR USAA070129Skin · crackedSTA 747 AND S23L HAS CRACK. INSTALLED DOUBLER PER SRM 53-00-01, DEFECT SIZE: 4 INCHES.SDR USAA070130Stringer · crackedSTRINGER SPLICE CHANNEL, BS 360 FRAME AND STRINGER 15L HAS CRACK. INSTALLED NEW STRINGER PER SRM 51-10-02, DEFECT SIZE: .5 INCH.SDR USAA070131Intercostal · crackedFWD END OF INTERCOSTAL WEB AT STR 12L AND BS 294.5 HAS CRACK. REMOVED CRACKED INTERCOSTAL & REPLACED WITH FAB'D PART PER BOEING DWG 55-17684, DEFECT SIZE: .125 INCH.SDR USAA070132Skin · crackedSKIN AT STA 727D + 12 INCHES STR 23R HAS CRACK. REMOVED DAMAGE & INSTALLED REPAIR DOUBLER & TRIPLER PER EA 98457, DEFECT SIZE: 1 INCH.SDR USAA070133Tie Clip · crackedSTA 360 STR 11L HAS CRACK. REMOVED DAMAGE & INSTALLED FAB'D REPAIR PARTS PER SRM 51-10-02, DEFECT SIZE: 2 INCHES.SDR USAA070134Skin · crackedAT PANEL (5827) OPENING FLANGE ON TOP OF RT PYLON INBOARD SIDE, STA 212.84 HAS CRACK. STOP DRILL CRACK, FAB'D SKIN DOUBLER & INSTALLED PER TYP REPAIR 54-30-07, DEFECT SIZE: .025 INCH.SDR USAA070135Frame · crackedTHE U-SHAPE FRAME IN NR 1 PYLON BELOW AFT SPAR CRACKED. REPLACED U-SHAPE FRAME PER EA 98483, DEFECT SIZE: 1 INCH.SDR USAA070136Tie Clip · crackedBS 360 S-9L HAS CRACK. FABRICATED & INSTALLED REPLACEMENT TIE CLIP PER BOEING DWG 69-46882 & SRM 51-10-02, DEFECT SIZE: .5 INCH.SDR USAA070137Frame · crackedAT 492.4 STR 24R FWD CARGO AFT FRAME HAS CRACK. REMOVED DAMAGE & INSTALLED FABRICATED REPAIR PARTS PER SRM 51-40-02 & 51-10-02, DEFECT SIZE: 3 INCHES.SDR USAA070138Skin · damagedSTA 1016 STR 5L AT LAV ATTACH MOUNT ELONGATED. INSTALLED DOUBLER & TRIPLER PER EA 98446, DEFECT SIZE: .5 INCH AREA.SDR USAA070139Floor Support · corrodedSTA 860 RBL 23 - LBL 33 HAS CORROSION. REMOVED DAMAGE & INSTALLED REPAIR ANGLE PER TR 53-10-06B; CORR LEVEL 2; TASK C53-208-01, DEFECT SIZE: 12 INCHES.SDR USAA070140Web · corrodedSTA 847 & 867 BETWEEN STR 26R & 25R HAS CORROSION. REMOVED DAMAGE & INSTALLED FAB'D REPAIR PARTS PER SRM 53-60-53, 51-10-02, CORR LEVEL 2; TASK C53-202, DEFECT SIZE: .5 INCH.SDR USAA070141Stringer · corrodedAREA ON STRINGER STA 847, STR 24R HAS CORROSION. U-CHANNEL INSTALLED INSIDE OF STRINGER PER SRM 53-00-03; CORR LEVEL 2; TSK C53-208-01, DEFECT SIZE: 3 X 4 INCHES.SDR USAA070117Stringer · crackedSTR 4I AT STA 907, CRACK EXTENDING FROM FASTENER HOLE. INSTALLED STRINGER SPLICE, REPAIR PARTS PER SRM 51-10-02, DEFECT SIZE: 1 INCH.SDR USAA070118Wedge · debondedNR 5 SLAT ON O/B END OF WEDGE DISBONDED. REPAIRED DISBOND AREA & INSTALLED EXTERNAL DOUBLER PER SRM 51-70-10, DEFECT SIZE: .5 X .75 INCH.SDR USAA070119Pan · corrodedAFT WET AREA FLOOR PAN A BASE OF PRESS BULKHEAD HAS CORROSION. REMOVED DAMAGED AREA & FABRICATED DOUBLER & INSTALLED PER SRM 51-70-13, DEFECT SIZE: 10 INCHES.
Back to Boeing 737-401