Boeing 737-401
Service difficulty reports · 2,961
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '737401' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '737401' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR USAA070120Strap · corrodedSTA 839-853 2 S26R BENEATH UPPER FLANGE OF WEB HAS CORROSION. FABRICATED NEW PART PER DWG 69-43456; CORR TASK C53-208-01; LEVEL 2, DEFECT SIZE: 1 INCH.SDR USAA070121Angle · corrodedSTA 867-947 AT S26R, UPPER & LOWER SURFACE OF TRANSITION ANGLE HAS CORROSION. FOUND CRACK & REPAIRED PER T/P, TREATED, PRIMED & REINSTALLED TRANSITION ANGLE PER SRM 51-60-53, DEFECT SIZE: 1 INCH.SDR USAA070122Skin · crackedRT PYLON TOP OUTBOARD SIDE, PANEL 5828 OPENING, PYLON STA 220.84 FLANGE CRACKED. STOP DRILL CRACK, FAB'D DOUBLER & INSTALLED PER TYP REP 54-30-07, DEFECT SIZE: .75 INCH.SDR USAA070123Stiffener · crackedBS 328 RBL 33 ON VERT STIFFENER CRACKED. DEFETIVE PART REPLACED WITH IDENT PART, DEFECT SIZE: 1 INCH.SDR USAA070124Stiffener · crackedSTA 277 S2L AND S3L CRACKED. REMOVED OLD PART & FAB'D NEW, DRILLED, TREATED & PRIMED PER SRM 51-10-02, BOEING DWG 65-49806, DEFECT SIZE: 1 INCH.SDR USAA070125Intercostal · crackedBS 294.5 STR 7L CRACKED. FAB'D NEW PART & INSTALLED PER DRAWING 65-17684, DEFECT SIZE: 2 INCHES.SDR USAA070126Stringer Splice · crackedBS 360 FRAME & STR 15L, STRINGER SPLICE CHANNEL CRACKED. INSTALLED NEW STRINGER PER SRM 51-10-02, DEFECT SIZE: .5 INCH.SDR SB07015Fuse · blownORD - MAINTENANCE FOUND THE LAST TWO ROWS OF FLOOR PROXIMITY EMERGENCY LIGHTING INOPERATIVE. MAINTENANCE SUSPECTS A BROKEN WIRE BUT WAS UNABLE TO LOCATE IT. AIRCRAFT WAS MAINTENANCE FERRIED TO PIT FOR REPAIRS. MAINTENANCE FOUND THE FUSE IN THE AFT EMERGENCYSDR USAA070065Angle · crackedLEFT WING STA 135.50 AFT INBOARD TOP CHORD ANGLE HAS CRACK. INSTALLED REPAIR PLATES, DOUBLERS & FILLER PER EA 98385, DEFECT SIZE: 1 INCH.SDR USAA070066Stringer · crackedRADIUS LT STRINGER 5A STA 1138 AT FUSELAGE CUTOUT FOR HORIZ STAB AFT LUG HAS CRACK. INSTALLED DOUBLER, REPAIR ANGLES PER SRM 53-00-01 FIG 201, REP 21, DEFECT SIZE: 3 INCHES.SDR USAA070067Attach Angle · crackedATTACH ANGLE AT LT WING STA 114 INBOARD SIDE UPPER AFT END IN FUEL TANK HAS CRACK. REMOVED DAMAGE, FABRICATED ANGLE DOUBLERS & INSTALLED PER EA 98389, DEFECT SIZE: 0.1 INCH.SDR USAA070068Skin · wornLOWER I/B CORNER T/E WEDGE NR 4 SLAT, WORN AREA/CHAFED. INSTALLED DOUBLER PER SRM 57-41-01-1A, DEFECT SIZE: .5 INCH.SDR USAA070069Pressure Panel · crackedBS 665, LBL 30, MLG WHEEL WELL PRESSURE FLOOR HAS CRACK. CUT OUT DAMAGED AREA, FAB'D & INSTALLED REPAIR DOUBLER, FILLERS, SHIMS, ANGLE PER TR 53-60-04, DEFECT SIZE: 1 INCH.SDR USAA070044Intercostal · corrodedAT SCREW HOLES, STA 328-344, RBL 11.5 HAS CORROSION. FAB'D NEW PART & INSTALLED; CORR TASK C53-107-02; LEVEL 2, DEFECT SIZE: 1 INCH.SDR USAA070042Floorbeam · corrodedBS 328 RBL 28.5 FLOORBEAM UPPER TEE HAS CORROSION. CORROSION REMOVED, BLENDED; FAB'D STRAP & INSTALLED PER SRM 53-00-51; CORROSION LEVEL 2; TASK C53-107-02, DEFECT SIZE: 1 X 1 X .020 INCH.SDR USAA070043Frame · crackedBS 492 S-21R, FWD CARGO DOOR CUTOUT, AFT FRAME AT INNER STOP HOLE. DEFECTIVE PART REPLACED WITH IDENT PART PER SRM 51-00-02, EO 5305V113, DEFECT SIZE: .250 INCH.SDR USAA070025Floor Support · corrodedSTATION 335 RBL 52 HAS CORROSION. REPLACED SUPPORT IAW SRM 51-40-00, 51-40-02, DEFECT SIZE: 1 INCH.SDR USAA070026Support Angle · corrodedSTATION 294.5-328 RBL 58 HAS CORROSION. REPLACED SUPPORT IAW SRM 51-10-02, DEFECT SIZE: .5 INCH.SDR USAA070027Angle · corrodedSTATION 312-360 RBL 56 HAS CORROSION. REPLACED ANGLE IAW 51-10-02, DEFECT SIZE: 1 INCH.SDR USAA070028Intercostal · corrodedSTATION 294.5 - 312 RBL 11.5 HAS CORROSION. REPLACED INTERCOSTAL IAW SRM 51-10-02, DEFECT SIZE: 18 INCHES.SDR USAA070030Floorbeam · corrodedSTATION 312 LBL 7 TO LBL 8 HAS CORROSION. ACCOMPLISHED T-CAP REPAIR IAW SRM 53-10-51, DEFECT SIZE: 1 INCH.SDR USAA070031Intercostal · corrodedSTATION 312-328 RBL 11.5 HAS CORROSION. REPLACED INTERCOSTAL IAW SRM 51-10-02, DEFECT SIZE: .75 INCH.SDR USAA070032Frame · crackedSTATION 350 ABOVE STRINGER 9R CRACKED. INSTALLED REPAIR DOUBLER IAW TR 53-10-20D, DEFECT SIZE: .5 INCH.SDR USAASB07006Battery Pack · dischargedMCO - MAINTENANCE REPORTED THE EMERGENCY LIGHTS AT ROW 11 INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE BATTERY PACK. OPERATIONAL CHECK GOOD.SDR USAA070024Floorbeam · corrodedFLOORBEAM AT STATION 727 + 7 RBL8. ACCOMPLISHED DOUBLER REPAIR IAW SRM 51-10-02, 53-60-53, TR 53-10-06B DEFECT SIZE: .5"SDR USAA070023Floorbeam · corrodedFLOORBEAM AT STATION 727 + 7 RBL 3. ACCOMPLISHED DOUBLER REPAIR IAW SRM 51-10-02, 53-60-53, TR 53-10-06B DEFECT SIZE: .5"SDR USAA070019Frame · crackedBS 360 BETWEEN S14L AND 15L CRACKED. FABRICATED AND INSTALLED REPAIR PARTS IAW SRM 51-10-02 AND DRAWING 69-48204, DEFECT SIZE: 3 INCHES.SDR USAA070020Mount · corrodedSTATION 312 & 344 LBL 58 HAS CORROSION. REPLACED MOUNTS IAW SRM 51-20-02, DEFECT SIZE: 1 X 1 INCH.SDR USAA070021Frame · crackedFWD CARGO AFT FRAME AT STRINGER 24R CRACKED. REMOVED DAMAGE AND INSTALLED FABRICATED REPAIR PARTS IAW EA 98384, DEFECT SIZE: 1 INCH.SDR USAA070022Stiffener · crackedSTATION 175.5 RT HORIZONTAL STAB CRACKED. REPLACED STIFFENER IAW DRAWING NUMBER 65-47513, DEFECT SIZE: 1 INCH.SDR USAA070015Frame · severedBS 277 INBOARD OF S3R ABOVE COCKPIT BULKHEAD SEVERED FRAME. REMOVED DAMAGE AND INSTALLED REPAIR PARTS IAW SRM 53-10-08, DEFECT SIZE: 4 INCHES.SDR USAA070016Floorbeam · corrodedAFT CARGO FLOORBEAM AT STATION 847 + 12 RBL 13 HAS CORROSION. REPAIRED IAW TR 53-10-06B, DEFECT SIZE: 4 INCHES.SDR USAA070017Floorbeam · corrodedAFT CARGO FLOOR TRACK/BEAM AT STATION 847 + 12 LBL 8 HAS CORROSION. REPAIRED IAW TR 53-10-06B, DEFECT SIZE: .5 INCH.SDR USAA070018Angle · corrodedSTATION 321 TO 344 LBL 60-62 HAS CORROSION. REPLACED ANGLE IAW SRM 51-10-02, DEFECT SIZE: 1 INCH.SDR USAASB07005Windshield · crackedORD FLT 1919 EN ROUTE FROM CLT TO ORD, CREW REPORTED THE CAPTAIN'S L1 WINDSHIELD BEGAN TO ARC AND THEN CRACK. FLIGHT LANDED WITHOUT FURTHER INCIDENT. MAINTENANCE REMOVED AND REPLACED THE CAPTAIN'S L1 WINDSHIELD PER JOB CARD J356-11-01. OPERATIONAL CHECK GOSDR USAA07002Fitting · corrodedSTA 303.5 LBL 11 LBL 44 HAS CORROSION. REMOVED AND REPLACED FITTING IAW SRM 51-10-02 LEVEL 1 C53-107-02, DEFECT SIZE: .5 X 1 INCH.SDR USAA061447Seat Track · crackedSTA 727B RBL 24.50 CRACKED. REMOVED DAMAGE, INSTALLED REPAIR PARTS IAW EA 98301, DEFECT SIZE: .375 INCH.SDR USAA061448Bracket · chafedSTA 277 S2L BRACKET CHAFING. INSTALLED NEW BRACKET AND REPAIR PARTS IAW EA 98279, DEFECT SIZE: 1.0 INCH.SDR USAA061449Seat Track · crackedSTA 727B RBL 45.50 CRACKED. REMOVED DAMAGE, INSTALLED REPAIR PARTS IAW SRM 535-00-52, DEFECT SIZE: .250 INCH.SDR USAA061439Floorbeam · crackedSTATION 520 RBL 45.5 CRACKED. REPAIRED DOUBLER FOR FLOORBEAM IAW EA 98297, DEFECT SIZE: 3.125 INCH.SDR USAA061440Frame · crackedBS 597 RBL 64 CRACKED. INSTALLED DOUBLER IAW EA 98276, DEFECT SIZE: .5 INCH.SDR USAA061443Floorbeam · crackedSTA 520 LBL 24.75 CRACKED. INSTALLED FLOORBEAM REPAIR PARTS AND INTERCOSTAL LINK KIT IAW EA 98297, DEFECT SIZE: .300 INCH.SDR USAA061444Crease Beam · corrodedRIGHT CREASE BEAM AT BS 235.8 CORRODED. CUT OUT AND REMOVED CORROSION IAW EA 98283 LEVEL 2 C53-101-01, DEFECT SIZE: .50 X 4 INCHES.SDR USAA061445Stiffener · crackedSTA 663 RBL 6.15 CRACKED. INSTALLED REPAIR DOUBLERS/ANGLES IAW TR 57-10-03B, DEFECT SIZE: .500 INCH.SDR USAA061446Floorbeam · crackedBS 706 FLOORBEAM LBL 24.5 CRACKED. CUT OUT DAMAGED AREA IAW EA 98304, DEFECT SIZE: .50 INCH.SDR USAA061421Angle · crackedSTA 540 STR 22R AT RAM AIR INLET CRACKED. REMOVED DAMAGE AND INSTALLED REPAIR PARTS IAW TR 53-50-03, DEFECT SIZE: 1 INCH.SDR USAA061423Stiffener · crackedRBL 6.15 WHEEL WELL AREA CRACKED. REMOVED DAMAGE AND INSTALLED FABRICATED REPAIR PARTS IAW TR 57-10-03B, DEFECT SIZE: 1 INCH.SDR USAA061407Frame · crackedSTA 727 S14L CRACKED. FRAME REPAIRED WITH FILLER AND DOUBLER IAW EA 98266, DEFECT SIZE: .750 INCH.SDR USAA061414Angle · crackedSTA 289 S10R-S11R CRACKED. REMOVED AND REPLACED ANGLE IAW SRM 51-10-00, DEFECT SIZE: 1.0 INCH.SDR USAA061413Frame · crackedSTA 380 FRAME AT UPPER FLANGE BETWEEN STR S20L AND S21L CRACKED. REMOVED DAMAGE AND INSTALLED REPAIR PARTS IAW SRM 51-70-11, DEFECT SIZE: 1 INCH.
Back to Boeing 737-401