SDR ASAA0140069Floorbeam · corrodedPAE - DURING SI CHECK, FOUND CORROSION ON UPPER CHOD OF 947 FLOORBEAM AT BS 947, WL 208, AND LBL 15 TO RBL 15. (M)May 4, 2001 · N780AS · Boeing 7374Q8 · Fuselage Main, Floor BeamSDR ASAA0140062Wire · disconnectedGEG - BEFORE FLIGHT, FOUND EMERGENCY FLOOR TRACK LIGHTING INOPERATIVE AT ROW 21. RECONNECTED LOOSE WIRE, OPS CHECK GOOD. (M)May 2, 2001 · N765AS · Boeing 7374Q8 · Light System WiringSDR ASAA0140061Light · inoperativePDX - DURING LINE CHECK,FOUND EMERGENCY EGRESS LIGHT AT L2 DOOR INOPERATIVE. RESTORED TENSIONING TO POSITIVE CONTACT AND RELAMPED. OPS CHECK GOOD. (M)May 2, 2001 · N763AS · Boeing 7374Q8 · Emergency LightingSDR ASAA0240012Threshold · corrodedPAE - DURING SI CHECK, FOUND CORROSION OF SUB THRESHOLD WEB AT STATION 787-794 AND RBL 20 AND WL 157. REMOVED AND REPLACED SUB THRESHOLD IAW SRM. (M)Apr 26, 2001 · N780AS · Boeing 7374Q8 · Fuselage Miscellaneous StructureSDR ASAA0240011Threshold · corrodedPAE - DURING SI CHECK, FOUND CORROSION OF SUB THRESHOLD WEB AT STATION 795-847 AND RBL 20-28 AND WL 160. REMOVED AND REPLACED SUB THRESHOLD IAW SRM. (M)Apr 26, 2001 · N780AS · Boeing 7374Q8 · Fuselage Miscellaneous StructureSDR ASAA0140060Wire · damagedSEA - DURING LINE CHECK, FOUND EMERGENCY FLOOR TRACK LIGHTS INOPERATIVE AT ROW 16. REPAIR WIRES, OPS CHECK GOOD. (M)Apr 24, 2001 · N756AS · Boeing 7374Q8 · Light System WiringSDR ASAA0140059Wire · disconnectedSEA - BEFORE FLIGHT, FOUND EMERGENCY TRACK LIGHTS AT ROW 17-19 INOPERATIVE, WIRE DISCONNECTED. RECONNECTED WIRES. OPS CHECKED NORMAL. (M)Apr 20, 2001 · N773AS · Boeing 7374Q8 · Emergency LightingSDR ASAA0140058Skin · puncturedPAE - DURING SI CHECK, FOUND RIGHT INBOARD FORE FLAP LOWER SKIN IS PUNCTURED 19 INCHES FROM INBOARD END AND 9 INCHES FROM TRAILING EDGE. REPAIRED IAW SRM 51-70-10. (M)Apr 12, 2001 · N779AS · Boeing 7374Q8 · Leading Edge DevicesSDR 2001F00137Cargo Track · damagedPAE - DURING SI CHECK, FOUND AFT CARGO BAY FLOOR TRACK AT BS 750 TO BS 756, WL 150 AND BL 3 LEFT AND RIGHT DAMAGED. REPAIRED IAW ASA EA 5320-01378. REF ASAA010057. (M)Apr 12, 2001 · N779AS · Boeing 7374Q8 · Fuselage, Seat/Cargo Attach FittingsSDR ASAA0140057Cargo Track · damagedPAE - DURING SI CHECK, FOUND AFT CARGO BAY FLOOR TRACK AT BS 750 TO BS 756, WL 150 AND BL 3 LEFT AND RIGHT DAMAGED. REPAIRED IAW ASA EA 5320-01378. (M)Apr 12, 2001 · N779AS · Boeing 7374Q8 · Fuselage, Seat/Cargo Attach FittingsSDR ASAA0140056Stringer Clip · bentPAE - DURING SI CHECK, FOUND AFT CARGO BAY STRINGER CLIP AT STRINGER RT, WL 158, BL 27 LEFT AND BS 727F IS BENT. REPLACED IAW SRM. (M)Apr 11, 2001 · N779AS · Boeing 7374Q8 · Fuselage Miscellaneous StructureSDR ASAA01040053Sill · corrodedPAE - DURING SI CHECK, FOUND CORROSION ON MOPSILL AT BS 344-350, LBL 56 AND WL 208. REMOVED AND REPLACE PER SRM 51-40-05. (M)Apr 10, 2001 · N779AS · Boeing 7374Q8 · Fuselage Miscellaneous StructureSDR ASAA0140051Floorbeam · corrodedPAE - DURING SI CHECK, FOUND FLOORBEAM CORRODED SEVERAL PLACED NEAR NUT PLATE HOLES AT BS 986.5, RBL 5-43, AND WL208, LEVEL 1. REPAIRED IAW SRM AND ASA EA5310-01928. (M)Apr 10, 2001 · N779AS · Boeing 7374Q8 · Fuselage Main, Floor BeamSDR ASAA0140050Floorbeam · corrodedPAE - DURING SI CHECK, FOUND FLOORBEAM CORRODED AT BS 1016, LBL 29 AND WL 208. REPAIRED IAW SRM AND ASA EA 5310-01925. (M)Apr 10, 2001 · N779AS · Boeing 7374Q8 · Fuselage Main, Floor BeamSDR ASAA0140052Sill · corrodedPAE - DURING SI CHECK, FOUND CORROSION ON MOPSILL AT BS 325, LBL 56 AND WL 208, LEVEL 2. REMOVED AND REPLACED PER SRM 51-40-05. (M)Apr 10, 2001 · N779AS · Boeing 7374Q8 · Fuselage Miscellaneous StructureSDR ASAA0140049Wire · brokenSEA - DURING LINE CHECK, FOUND EMERGENCY FLOOR TRACK LIGHTING AT MID CABIN INOPERATIVE, WIRE BROKEN. REPAIRED BROKEN WIRE. OPS CHECK NORMAL. (M)Apr 9, 2001 · N782AS · Boeing 7374Q8 · Light System WiringSDR ASAA0140048Wire · brokenSEA - DURING LINE CHECK, FOUND EMERGENCY FLOOR TRACK LIGHTING AT ROWS 16ABC TO 19ABC INOPERATIVE, WIRE BROKEN. REPAIRED BROKEN WIRE. OPS CHECK NORMAL. (M)Apr 9, 2001 · N771AS · Boeing 7374Q8 · Light System WiringSDR ASAA0140047Support Fitting · corrodedPAE - DURING SI CHECK, FOUND GIRT BAR SUPPORT FITTING CORRODED AT BS 344, WL 208 AND LBL 56 (LEVEL II). REPLACED IAW SRM. (M)Mar 30, 2001 · N779AS · Boeing 7374Q8 · Fuselage Miscellaneous StructureSDR ASAA0140046Support Fitting · corrodedPAE - DURING SI CHECK, FOUND CORROSION ON GIRT BAR SUPPORT FITTING AT BS 312, WL 208, LBL 55. REPLACED IAW WITH SRM. (M)Mar 30, 2001 · N779AS · Boeing 7374Q8 · Fuselage Miscellaneous StructureSDR ASAA0140045Sill · corrodedPAE - DURING SI CHECK, FOUND CORROSION ON MOPSILL AT BS 943-998, LBL 52 AND WL 208 (LEVEL II) REPLACED IAW SRM. (M)Mar 29, 2001 · N779AS · Boeing 7374Q8 · Fuselage Miscellaneous StructureSDR ASAA0140044Sill · corrodedPAE - DURING SI CHECK, FOUND CORROSION ON MOPSILL AT BS 334, WL 208 AND RBL 57 , LEVEL II. REPLACED IAW SRM. (M)Mar 28, 2001 · N779AS · Boeing 7374Q8 · Fuselage Miscellaneous StructureSDR ASAA0140043Doubler · crackedPAE - DURING SI CHECK, FOUND EXTERNAL POWER CUT OUT INTERNAL SKIN DOUBLER IS CRACKED AT TWO LOCATIONS FORWARD LOWER CORNER AT STATION 228 AND RBL 30 AND WL 175 TO 185. REPAIRED IAW EA 5330-01514. (M)Mar 28, 2001 · N779AS · Boeing 7374Q8 · Fuselage Main, Plate/SkinSDR ASAA0140042Floorbeam · corrodedPAE - DURING SI CHECK, FOUND CORROSION ON FLOORBEAM NUT PLATE HOLES AT BS 986.5 LBL 2 TO 43 AND WL 208, LEVEL 2. REPAIR PENDING. (M)Mar 25, 2001 · N779AS · Boeing 7374Q8 · Fuselage Main, Floor BeamSDR ASAA0140040Frame · crackedPAE - DURING SI CHECK, FOUND SIDE CHORD ON LEFT AND RIGHT SIDE AT BS 178 AND WL 207 CRACKED. REPAIR PENDING. (M)Mar 25, 2001 · N779AS · Boeing 7374Q8 · Fuselage Main, FrameSDR ASAA0140041Floorbeam · corrodedPAE - DURING SI CHECK, FOUND CORROSION ON FLOORBEAM AT BS 947, RT BL 4 AND WL 208, LEVEL II. REPAIRED PER SRM 53-00-51. (M)Mar 25, 2001 · N779AS · Boeing 7374Q8 · Fuselage Main, Floor BeamSDR ASAA0140039Light · disconnectedFAI - BEFORE FLIGHT, FOUND EMERGENCY FLOOR TRACK LIGHTS AT AFT MID CABIN INOPERATIVE. RECONNECTED WIRES, OPS CHECKS GOOD. (M)Mar 24, 2001 · N763AS · Boeing 7374Q8 · Emergency LightingSDR ASAA0140038Connector · disconnectedSEA - DURING LINE CHECK, FOUND EMERGENCY TRACK LIGHTING INOPERATIVE AT ROW 15/16 ABC. RECONNECTED EMERGENCY TRACK LIGHT WIRES. OPS CHECK NORMAL. (M)Mar 23, 2001 · N776AS · Boeing 7374Q8 · Emergency LightingSDR ASAA0140033Shear Tie · corrodedPAE - DURING SI CHECK, FOUND CORROSION ON SHEAR TIE AT STATION 767 TO WATERLINE 150 AND BUTT LINE 19. REMOVED AND REPLACED SHEAR TIE IAW SRM. (M)Feb 27, 2001 · N778AS · Boeing 7374Q8 · Fuselage Main, StructureSDR ASAA0140032Floorbeam · corrodedPAE - DURING SI CHECK, FOUND CORROSION ON UPPER CHORD OF FLOORBEAM. REMOVED AND REPLACED IAW SRM. (M)Feb 27, 2001 · N778AS · Boeing 7374Q8 · Fuselage Main, Floor BeamSDR ASAA0140031Sill · corrodedPAE - DURING SI CHECK, FOUND CORROSION ON MOPSILL. REMOVED AND REPLACED IAW SRM. (M)Feb 27, 2001 · N778AS · Boeing 7374Q8 · Fuselage Miscellaneous StructureSDR ASAA0140030Floorbeam · corrodedPAE - DURING SI CHECK, FOUND CORROSION ON FLOORBEAM. REPAIRED IAW SRM. (M)Feb 27, 2001 · N778AS · Boeing 7374Q8 · Fuselage Main, Floor BeamSDR ASAA0140026Strap · corrodedPAE - DURING SI CHECK, FOUND CORROSION ON MOPSILL STRAP. REPLACED MOPSILL STRAP IAW SRM. (M)Feb 16, 2001 · N778AS · Boeing 7374Q8 · Fuselage Miscellaneous StructureSDR ASAA0140025Sill · corrodedPAE - DURING SI CHECK, FOUND CORROSION ON MOPSILL. REPLACED MOPSILL IAW SRM. (M)Feb 16, 2001 · N778AS · Boeing 7374Q8 · Fuselage Miscellaneous StructureSDR ASAA0140024Frame · crackedPAE - DURING MAINTENANCE INSPECTION, FOUND CRACK IN FRAME AT FASTENER AT STATION 360, WATERLINE 270, AND BUTTLINE 63 LEFT. REPAIRED IAW SRM. (M)Feb 10, 2001 · N778AS · Boeing 7374Q8 · Fuselage Main, FrameSDR ASAA0140023Shear Tie · corrodedPAE - DURING MAINTENANCE INSPECTION FOUND CORROSION ON SHEAR TIE AT STATION 767 WATERLINE 149 AND BUTTLINE 10 RIGHT AND LEFT SIDES. REPAIRED IAW SRM. (M)Feb 10, 2001 · N778AS · Boeing 7374Q8 · Fuselage Main, StructureSDR ASAA0140022Wire · brokenSEA - WHILE PERFORMING A LINE CHECK, FOUND EMERGENCY FLOOR TRACK LIGHTS AT ROW 1 INOPERATIVE, WIRE BROKEN. REMOVED AND REPLACED EMERGENCY FLOOR ASSEMBLY. OPS CHECKED GOOD. (M)Feb 9, 2001 · N785AS · Boeing 7374Q8 · Light System WiringSDR ASAA0140021Seat Track · corrodedPAE - DURING SI CHECK, FOUND CORROSION OUT OF LIMITS ON SEAT TRACK FROM BS 360-480 AND RBL 24.75 AND WBL 208. REPAIRED IAW SRM. (M)Feb 8, 2001 · N778AS · Boeing 7374Q8 · Fuselage, Seat/Cargo Attach FittingsSDR ASAA0140019Connector · disconnectedTUS - BEFORE FLIGHT, FOUND EMERGENCY FLOOR ESCAPE EXIT MARKERS INOPERATIVE. FOUND LOOSE CONNECTION, RESECURED CONNECTION. OPERATIONAL CHECK GOOD. (M)Feb 3, 2001 · N774AS · Boeing 7374Q8 · Emergency LightingSDR ASAA0140020Connector · disconnectedPDX - BEFORE FLIGHT FOUND EMERGENCY FLOOR TRACK LIGHTS INOPERATIVE AT ROW 14/15, DISCONNECTED. RECONNECTED FLOOR TRACK LIGHTS. OPERATIONAL CHECKS GOOD. (M)Feb 3, 2001 · N765AS · Boeing 7374Q8 · Emergency LightingSDR ASAA0140017Frame · crackedPAE - DURING SI CHECK, FOUND CRACK 1 INCH LONG AT BS 178 SIDE CHORD AT WL 207, RBL 28 AND LBL 28. (M)Feb 2, 2001 · N778AS · Boeing 7374Q8 · Fuselage Main, FrameSDR AU010154Skin · delaminated(AUS) RT AFT OUTER FLAP TRAILING EDGE DELAMINATING AT INBOARD AFT CORNER.Feb 2, 2001 · Boeing 7374Q8 · Trailing Edge FlapsSDR ASAA0140016Power Supply · inoperativeSEA - DURING LINE CHECK, FOUND OVERHEAD BIN EMERGENCY LIGHT AT ROW 16 RIGHT INOPERATIVE. REMOVED AND REPLACED POWER SUPPLY, OPERATIONAL CHECKS NORMAL. (M)Jan 28, 2001 · N775AS · Boeing 7374Q8 · Emergency LightingSDR ASAA0140014Light · disconnectedPDX - DURING LINE CHECK, FOUND EMERGENCY TRACK LIGHT INOPERATIVE AT ROWS 13-15. RECONNECTED EMERGENCY FLOOR LIGHTS AT ROWS 13-15. OPERATIONAL CHECKS NORMAL. (M)Jan 27, 2001 · N776AS · Boeing 7374Q8 · Emergency LightingSDR ASAA0140015Light · disconnectedPDX - DURING LINE CHECK, FOUND EMERGENCY TRACK LIGHT INOPERATIVE IN AFT CABIN AFT 3 LIGHTS. RECONNECTED EMERGENCY FLOOR LIGHTS IN AFT CABIN. OPERATIONAL CHECKS NORMAL. (M)Jan 27, 2001 · N778AS · Boeing 7374Q8 · Emergency LightingSDR ASAA0140013Light · inoperativePDX - DURING LINE CHECK, FOUND 2 FORWARD RED EMERGENCY TRACK LIGHTS INOPERATIVE. REPLACED EMERGENCY FLOOR TRACK LIGHT ASSEMBLY. OPERATIONAL CHECKS GOOD. (M)Jan 23, 2001 · N765AS · Boeing 7374Q8 · Emergency LightingSDR ASAA0140009Light · disconnectedPDX - WHEN PERFORMING LINE CHECK, FOUND EMERGENCY FLOOR TRACK LIGHTS INOPERATIVE IN AFT CABIN. RECONNECTED LIGHTS, OPS NORMAL. (M)Jan 21, 2001 · N778AS · Boeing 7374Q8 · Emergency LightingSDR ASAA0140010Light · disconnectedPDX - WHEN PERFORMING LINE CHECK, FOUND EMERGENCY FLOOR TRACK LIGHTS INOPERATIVE AT ROW 17-19. RECONNECTED LIGHTS OPS NORMAL. (M)Jan 21, 2001 · N778AS · Boeing 7374Q8 · Emergency LightingSDR ASAA0140012Light · disconnectedSAN - BEFORE FLIGHT, FOUND EMERGENCY FLOOR TRACK LIGHTS INOPERATIVE AT ROW 12-15. RECONNECTED LIGHTS OPS NORMAL. (M)Jan 21, 2001 · N765AS · Boeing 7374Q8 · Emergency LightingSDR ASAA0140008Wire · disconnectedPDX - WHEN PERFORMING LINE CHECK, FOUND EMERGENCY FLOOR TRACK LIGHTS INOPERATIVE AT ROW 13-16. RECONNECTED LIGHTS, OPS NORMAL. (M)Jan 20, 2001 · N774AS · Boeing 7374Q8 · Light System WiringSDR ASAA0140011Light · disconnectedSEA - WHEN PERFORMING LINE CHECK, FOUND EMERGENCY FLOOR TRACK LIGHTS INOPERATIVE AT ROW 15-18. RECONNECTED LIGHTS OPS NORMAL. (M)Jan 20, 2001 · N784AS · Boeing 7374Q8 · Emergency Lighting
Back to Boeing 737-4Q8