What was found
PAE - DURING SI CHECK, FOUND CORROSION OF SUB THRESHOLD WEB AT STATION 787-794 AND RBL 20 AND WL 157. REMOVED AND REPLACED SUB THRESHOLD IAW SRM. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.