Boeing 737-522
Service difficulty reports · 1,682
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '737522' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '737522' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR 2008UALA02974Flap · delaminatedLEFT WING AFT INBOARD FLAP OUTBOARD EDGE APPEARS TO BE DELAMINATED. SUSPECT MOISTURE CONTAMINATION. REPAIRED BY SHOP MECHANIC PER GNMM 01-0-01-024. AC OK FOR SERVICE.SDR 2008UALA02975Stringer Splice · corrodedE&E COMPARTMENT STRINGER SPLICE CORRODED BS 380 & STRINGER S-27L. MAJOR REPAIR ACCOMPLISHED: REMOVED DAMAGED STRINGER SPLICE. REPLACED WITH NEW SPLICE P/N 65-59664-501.SDR 2008UALA02958Oxygen System · low pressureCREW OXYGEN SYSTEM LOW. RECORD PRESSURE PRIOR TO SERVICING. SUSPECT PRE FLIGHT CHECKS. SERVICED OXYGEN SYSTEM TO FULL. AC OK FOR SERVICE.SDR 2008UALA02902Light · inoperativeEMERGENCY EXIT LIGHTS INOP ON FLOOR FROM ROW 15 TO AFT GALLEY. REPLACED RIBBON CABLE IN EEL TRACK & AFT GALLEY FLOOR LIGHT.SDR 2008UALA02887Connector · deterioratedF/O'S O2 MASK MIC INOP. CREW TO SWAP WITH 1ST OBSERVER O2 MASK & ADVISE. WHEN TROUBLE SHOOTING FOUND FAULTY CONNECTOR. REPLACED CONNECTOR OP CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA02874Battery · dischargedAFT EMERGENCY FLASHLIGHT INOPERATIVE. SUSPECT FAULTY BATTERY. REPLACED BATTERY, OP CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA02848Door Frame · damagedFWD CARGO PIT DOOR CUTOUT FWD FRAME HAS DAMAGE UNDER LOWER STOP FITTING. MAJOR REPAIR ACCOMPLISHED: REPLACED FRAME.SDR 2008UALA02839Crease Beam · unknownFUSELAGE STR 17R CREASE BEAM NEEDS CUT AT BS 400. MAJOR REPAIR ACCOMPLISHED, FABRICATED REPAIR ANGLES AND INSTALLED NESTED ANGLE DOUBLER/TRIPLER REPAIR.SDR 2008UALA02827Slide · out of positionFWD GALLEY DOOR 1R SLIDE PACK GIRT NEEDS REPACK - GIRT DRAGGING ON FLOOR AND DOOR FRAME WHEN DOOR IS OPERATED. SUSPECT SLIDE IMPROPERLY INSTALLED. REPOSITIONED GIRT PER MM 25-61-35 PG 208, AC OK FOR SERVICE.SDR 2008UALA02826Slide · crackedFWD ENTRY DOOR FWD SLIDE COVER CRACKED AT GIRT BAR HANGER. FOUND MAIN ENTRY DOOR SLIDE DAMAGED. REPLACED SLIDE ASSEMBLY IAW MM 25-61-35. AC OK FOR SERVICE.SDR 2008UALA02799Skin · delaminatedLT OTBD FLAP INBD EDGE DELAMINATED 4 INCH BY 7 INCH. MOISTURE IS PRESENT. REPLACED LT OUTBOARD AFT FLAP AND OPS CHECKED REF MM 27-51-39-401. ACFT OK FOR SERVICE.SDR 2008UALA02800Battery · dischargedMID CABIN EMERGENCY LIGHTING INOPERATIVE. REPLACED BATTERY AND OP CHK'D GOOD.SDR 2008UALA02781Wire · shortedBURNING ODOR NOTED THROUGHOUT THE ACFT. ODOR DISSIPATED WHEN RECIC FAN WAS TURNED OFF. AFTER EXTENSIVE TROUBLE SHOOTING AND PART REPLACEMENT REPAIRED WIRE W090-018-24 REF WD21-61-01 BETWEEN CABIN TEMP CONTROLLER AND CABIN TEMP SELECTOR. FOUND WIRE SHORTED TOSDR UALA2008111302764Clamp · leakingRTFL DUE TO A WING/BODY OVERHEAT INDICATION. NORMAL LANDING. FOUND PNEUMATIC LEAK JUST INBOARD OF NR 1 ENG PYLON AT CLAMP. REPLACED CLAMP, NO LEAK NOTED. RUNUP CREW RAN BOTH ENGS AT HIGH THRUST SETTINGS FOR SEVERAL MINUTES WITH NO OVERHEAT WARNING. A/C OKSDR 2008UALA02777Girt Bar · looseDOOR 1L GIRT BAR LOOSE. *S/D* FOUND GIRT BAR LOOSE IN STOWED POS ON DOOR WHEN SLIDE UNARMED. ADJUSTED HOLDER FOR GIRT BAR ON DOOR. AC OK FOR SERVICE.SDR 2008UALA02764Warning System · activatedRTFL DUE TO A WING/BODY OVERHEAT INDICATION. NORMAL LANDING.
SDR 2008UALA02706Clamp · looseRTFL DUE TO WING BODY OVERHEAT WARNING. FOUND PNEUMATIC LEAK JUST INBOARD OF NR 1 ENGINE PYLON AT CLAMP. REPLACED CLAMP.SDR 2008UALA02692Bottle · low pressureCREW OXYGEN SYSTEM LOW. CREW COMMENTS: CREW O2 READS 1250. SUSPECT PRE FLIGHT CHECKS. SERVICED OXYGEN SYSTEM. AC OK FOR SERVICE.SDR UALA2008111302631Wedge · damagedNR 3 SLAT T/E WEDGE ASSEMBLY HAS DAMAGE. *S/D* METAL OVERLAY PIECE IS LOCATED IN THE FLIGHT DECK. PERFORMED REPAIR OF SLAT 3 TRAILING EDGE WEDGE BOND ASSEMBLY. PRIMED AND PAINTED AREA.SDR 2008UALA02631Wedge · damagedNR 3 SLAT T/E WEDGE ASSEMBLY HAS DAMAGE.SDR 2008UALA02643Oxygen Mask · faultyFO O2 MASK HISSES, LEAKS WHEN DONNED. REPLACED FIRST OFFICERS O2 MASK PER MM 35-12-86. OP CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA02615Warning Light · false activationAFT SERVICE DOOR SHOWED OPEN AFTER DEPARTURE. NO DEFECTS NOTED. UNABLE TO DUPLICATED ON GROUND.SDR 2008UALA02543Lamp · inoperativeDOOR 1R EXTERIOR EMERGENCY LIGHT IS INOP. SUSPECT FAULTY LAMP. REPLACED LAMP OP CHECKED GOOD. AC OK FOR SERVICE.SDR UALA2008111302447Unknown · odorCREW REPORTS FAINT ELECTRICAL BURNING SMELL FROM FORWARD CABIN NEAR DOOR 1 POSSIBLY FROM FWD CABIN SPEAKER, CAPT ADVISED TO OPEN THE PA AMP CB P6-1 D5 IF NECESSARY TO REMOVE POWER FROM THE CABIN SPEAKERS AND WILL LOSE THE CHIME SYS IF IT'S PULLED. F/A REPORTSSDR 2008UALA02464Light · inoperativeFLOOR EEL LIGHTS INOP FROM ROW 16 ON BACK. SUSPECT FAULTY LIGHT ASSEMBLY. REPLACED BAD LIGHT STRIP. OPS CK GOOD.AC OK FOR SERVICE.SDR 2008UALA02463Light · inoperativeL EXTERIOR OVERWING EMERGENCY EXIT LIGHT INOP. RELAMPED.SDR 2008UALA02447Speaker · odorCREW REPORTS FAINT ELECTRICAL BURNING SMELL FROM FORWARD CABIN NEAR DOOR 1 POSSIBLY FROM FWD CABIN SPEAKER, CAPT ADVISED TO OPEN THE PA AMP CB P6-1 D5 IF NECESSARY TO REMOVE POWER FROM THE CABIN SPEAKERS AND WILL LOSE THE CHIME SYS IF IT'S PULLED.
SDR 2008UALA02485Flap · delaminatedRT INBOARD TRAILING EDGE FLAP HAS APPROX 10 IN DELAMINATION ON INBOARD TRAILING EDGE. REPAIRED TRAILING EDGE REF SRM 51-70-10 P201 REPAIR 1. ACFT OK FOR SERVICE.SDR 2008UALA02426Oxygen Mask · faultyCAPT O2 MASK MIC INOP SAMC TEXT: REPLACE CAPTAINS O2 MASK STOWAGE BOX. REPLACED OXYGEN MASK STOWAGE BOX.SDR 2008UALA02403Acm · failedSIGNIFICANT OIL SMELL IN CABIN ON START UP AND DESCENT. FOUND RT AIR CYCLE MACHINE FAILED. REPLACED AIR CYCLE MACHINE.SDR 2008UALA02304Structure · damagedRT INBD FWD FLAP LWR SURFACE HAS 1-2 INCH HOLE FROM EMBEDDED ROCK 1 FOOT FROM INBD EDGE AND 6 INCH FROM TRAILING EDGE. FOUND FOD DAMAGE. REPLACED INBOARD FORE FLAP PER MM 27-51-07. ACFT OK FOR SERVICE.SDR 2008UALA02278Radar · malfunctionedFLIGHT DIVERTED DUE TO WEATHER RADAR PROBLEM. RESET WEATHER RADAR R/T.SDR 2008UALA02263Fire Loop · inoperativeNR 2 ENG FIRE LOOP 'A' INOPERATIVE. AFTER EXSTENSIVE TROUBLE SHOOTING FOUND FIRE LOOP FAULTY. REPLACED ENGINE NR 2 LOWER FAN FIRE LOOP DETECTION. SYSTEM TESTED NORMAL IAW MM 26-11-11-401. AC OK FOR SERVICE.SDR 2008UALA02262Unknown · odorVERY STRONG BURNING RUBBER TYPE ODOR IN FWD CABIN AREA OCCURRED SHORTLY AFTER LANDING GEAR LOWERED, STILL NOTICEABLE AT GATE.SDR 2008UALA02175Control Panel · failedFOUND NR 1 CARGO FIRE BOTTLE DISCHARGED TO DIVERTER VALVE. LOOSENED LINE AT BOTTOM OF BOTTLE TO RELIEVE HALON TRAPPED IN LINE. CONNECTOR FOR PRESSURE SWITCH ON BOTTLE DISCONNECTED. PER FLT CREW, DISCHARGE BUTTON WAS NOT PUSHED. REPLACED THE CARGO FIRE DETESDR 2008UALA02010Fire Detector · inoperativeAPU FIRE SUPPRESSION SYS INOP. REPLACED APU FIRE EXTINGUISHER BOTTLE ASSY. ENGINE & APU FIREX BOTTLE RUPTURE DISC ASSY & ENG/APU FIRE CONTROL P8-1 MODULE PRINTED CIRCUIT.TROUBLESHOOT AND REPAIRED "APU FIRE DET LIGHT".
SDR UALA2008111301969Wire · faultyFLIGHT ATTENDANT NOTICED HOT ODOR AT FWD GALLEY. SMELL WAS ELECTRIC. THEN SPARK OCCURRED FROM COFFEEMARKER GRILL (HOT PLATE) THEN ARC AND PUFF OF SMOKE. FOUND BURNED WIRE ON FORWARD GALLEY COFFEEMAKER. REPLACED COFFEEMAKER. AWAITING SHOP FINDINGS.SDR 2008UALA01969Coffeemaker · faultyFLIGHT ATTENDANT NOTICED HOT SMELL AT FWD GALLEY. SMELL WAS ELECTRIC. THEN SPARK OCCURRED FROM COFFEE MARKER GRILL (HOT PLATE) THEN ARC AND PUFF OF SMOKE.SDR 2008UALA01934Warning Light · false indicationRTFL DUE TO APU FIRE WARNING. NO SIGNS OF FIRE FOUND.SDR 2008UALA01933Striker · looseRTFL FOR A REPORTED AFT CARGO DOOR WARNING. FOUND LOOSE STRIKER ON CARGO DOOR. TIGHTENED.SDR 2008UALA01796Charger · inoperativeFWD ENTRY AND RT EMERGENCY LIGHTS INOP, REPLACED CHARGER M1132 AND CHKD OK, REF WD 33-51-12.
SDR 2008UALA01717Power Supply · inoperativeFLOOR EEL LIGHTS INOP FROM ROW 15 TO AFT GALLEY. REPLACED WET POWER FEEDER.SDR 2008UALA01629Skin · delaminatedNR 5 LE SLAT, OUTBD T/E REPAIR IS DELAMINATING FROM UPPER SKIN SURFACE. MAJOR REPAIR: REPAIRED DELAMINATION.SDR 2008UALA01539Strip · looseRTFL DUE TO A SMALL STRIP OF METAL HANGING FROM RIGHT WING. RE-BONDED METAL STRIP TO WING.SDR 2008UALA01543Module · faultyCREW REPORTS 1 ENG B FIRE LOOP WILL NOT TEST, A FIRE LOOP TESTS GOOD. SUSPECT FIRE TEST MODULE. REPLACED ENGINE AND APU FIRE CONTROL MODULE REFERENCE AMM 26-21-51. AC OK FOR SERVICE.SDR 2008UALA01478Bottle · faultyAPU BOTTLE DISCHARGE LIGHT ILLUMINATED. AFTER TROUBLE SHOOTING SYSTEM FOUND FIRE EXTINGUISHING BOTTLE FAULTY. REPLACED APU FIRE EXTINGUISHING BOTTLE IAW MM 26-22-11. AC OK FOR SERVICE.SDR 2008UALA01468Wire · frayedF/O O2 MASK MIC INOP. WIRE IS VISIBLY FRAYED. REPLACED MASK OPS CK GOOD. AC OK FOR SERVICE.SDR UALA2008111301384Window · crackedCREW REPORT: L2 WINDOW CRACKED AND ARCED ON APPROACH INTO YYZ AT 2000 MSL. TURNED OFF WINDOW HEAT. *S/D* REPLACED THE 2L WINDOW.SDR 2008UALA01384Window · crackedCREW REPORT: L2 WINDOW CRACKED AND ARCED ON APPROACH INTO YYZ AT 2000 MSL. TURNED OFF WINDOW HEAT.SDR 2008UALA01269Skin · crackedDOOR 2R HAS TWO INCH CRACK IN FUSELAGE SKIN AT LOWER FWD CORNER. MAJOR REPAIR ACCOMPLISHED: MANUFACTURED & INSTALLED FILLER, DOUBLER NR 1, DOUBLER NR 2 AND TRIPLER REPAIR.