Boeing 737-724
Service difficulty reports · 3,422
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '737724' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '737724' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2026070817615Probe · faultedEGT ON NR 1 ENG SHOWED 954 AND IN YELLOW AT CLIMB THRUST CLIMB THRUST PERFORMED FIM 71-06 TASK 804, NO RED BOX AROUND DIGITAL EGT INDICATION. PERFORMED EEC BITE PROCEDURE 73-00 TASK 801 AND FOUND FAULT MSSG 77-20861 (BOTTOM LEFT EGT OUT OF RANGE). INPUT MONITOSDR CALA2026070517536Filter · odorODOR IN AFT CABIN AT CRUISE SDR ADDED. UPDATED WITH FORM REF LP 9479753 FOR CORRECTIVE ACTION PERFORM SMOKE/ODOR IN THE FLIGHT DECK/CABIN - CONDITIONAL INSPECTION PER AMM 05-51-26-800-801-C1 PERFORMED SMOKE AND ODOR INSPECTION, RAN BOTH ENGINES, PACKS AND APUSDR CALA2026063017487Fitting · corrodedRIGHT WING AT RIB 27. THE LOWER FWD TENSION FITTING AT THE AFT ATTACH HOLE HAS PITTING CORROSION AT 11:00 O'CLOCK FACING INBD. REPAIRED R/W AT RIB 27 LOWER FWD TENSION FITTING AT AFT ATTACH HOLE IAW UAL AVO17710 REV ORIGINAL AND UAL ECRA 5720- 03661 REV ORIGINSDR CALA2026062917382Housing · damagedEMERGENCY LIGHTS - OPERATIONAL CHECK EMERGENCY LIGHTS OPERATIONAL CHECK - ROW 29 ABC EPL SHROUD IS DAMAGED AND NOT SECURED TO SEAT REMOVED AND REPLACED THE BROKEN SHROUD. REF CMM 25-21-56.SDR CALA2026063017475Latch · damagedOPEN ENG LATCHES ON NR 2 ENGINE. CONTACTED ENGINEERING AND APPLYING ECRA 5452-01160. TERMINATING ACTION TO BE COMPLETED IN 5 DAYS.111 LATCH OF CONCERN IS INBD AFT LATCH, SECURED REF ECRA5452-01160. INTERIM REPAIR MADE TO #2 ENGINE PYLON THUMBNAIL FAIRING LATCHSDR CALA2026071417745Skin · crackedCRACK FOUND ON RIGHT HORIZONTAL STABILIZER LOWER SKIN AT STAB STA 157.10 , 16" FROM FRONT SPAR , I/B ROW. CRACK LENGTH 1". REF AAR N/R 100049510CATEGORY B REPAIR,SDR CALA2026062517349Valve · faultyCOULD NOT MAINTAIN CABIN TEMP ACCOMPLISHED 700 CABIN TEMP HOT. CABIN TEMP CONTROLLER BITE PASSED. FOUND BAD 35 DEGREE VALVE ON RIGHT PACK. VAVLE OPENS, BUT WONT CLOSE. ALSO, RIGHT CONTROLLER KNOB BROKEN, AND LEFT 35 DEGREE VALVE MISSING POSITION INDICATOR. SDR CALA2026062417318Bulb · inoperativeLIGHT INOPERATIVE AT 21A EMERGENCY LIGHT SIGN. REPLACED THE BULB AT EMERGENCY EXIT SIGN ABOVE DOOR AT SEAT 21A IAW AMM 33-51-01-960-801.SDR CALA2026062417314Unknown · odorVERY MUSTY ODOR FROM ENVIRON SYS IN COCKPIT & CABIN. CABIN CREW REPORTED THEY DID NOT NOTICE ANY SMOKE OR ODOR THROUGHOUT FLIGHT. BURN OUT HAS BEEN REQUESTED TO CORRECT FAULT PER AMM TASK 05-51-26-800-801-C1 SECTION E. COMPLIANCE ON BURNOUT IAW AMM. NO MUSDR CALA2026062417319Window · leakingLOUD SQUEALING FROM CAPTAIN SIDE WINDOWS INCREASING WITH ALTITUDE L2 & L3 WINDOWS WERE REPLACED ON THE 16TH AND 18TH. PRESSURIZ ED THE ACFT AT THE GATE & OBSERVED BUBBLES (LEAKING) FROM EXTERIOR AT L2 WINDOW & PER DEBRIEFING WITH PILOT AIR BLOWING INTO THE FLSDR CALA2026061517102Support Beam · damagedSUPPORT BEAM IS DAMAGED ON LOWER FLANGE FROM HP DOOR 192DR LATCH.DAMAGE IS BEYOND ALLOWABLE LIMITS, WILL NEED SRM REPAIR. MAJOR REPAIR. COMPLIED WITH STEPS 4 A-E FOR REPAIR SRM 57-10-13-2R-3. REQUST HFEC SURFACE SCAN FOR DAMAGE CUTOUT AND HOLE PROBE FOR 4 NSDR CALA2026061517114Battery Pack · no testEMERGENCY LIGHT BATTERY PACK M1675 FAILS CAPACITY CHECK.POWER SUPPLY. REMOVED AND REPLACED BATTERY PACK IAW 33-51-06-960-805 OPS CHKD GOODSDR CALA2026061517113Battery Pack · no testEMERGENCY LIGHT BATTERY PACK M1672 FAILS CAPACITY CHECK.POWER SUPPLY. REPLACED #M1672 EMERGENCY LIGHT BATTERY, OPS CHKD GOOD IAW MM 33-51-06-960-805.SDR CALA2026061517112Battery Pack · no testEMERGENCY LIGHT BATTERY PACK M1668 FAILS CAPACITY CHECK.POWER SUPPLY BATTERY PACK CAPACITY CHECK POWER SUPPLY, REMOVED AND REPLACED BATTERY PACK IAW 33-51-06-960-805 OPS CHKD GOOD.SDR CALA2026060816922Door Frame · crackedL1 DOOR AFT UPPER INNER CORNER BENT. REMOVED FASTENER AND STRAIGHTENED MATERIAL IAW AVO 0814-06052026-1 STEPS 1 AND 2. READY FOR HFE. INSPECTION PER STEPS 3 AND 4. DURING REMOVAL OF FASTENER FOUND CRACK AT HOLE, PERFORMED HFEC OF DAMAGED AREA, CONFIRMED CRACKSDR CALA2026060816915Battery Pack · no testEMERGENCY LIGHT BATTERY AT M1673 FAILS 15 MIN. CAPACITY CHECK. REMOVED AND REPLACED BATTERY PACK M1673 IAW MM 33-51-06.SDR CALA2026060316764Housing · damagedEXIT PATH LIGHT SIGN AT 25C NEEDS REPAIR. REQUEST TO DEFER EMERGENCY PATHWAY LIGHT LOCATED AT SEAT 25C USING MEL 3319E TOMC APPROVED COMPLIED WITH MEL 3319E COMPLIED WITH MEL 3319E *DM* ADDED SEAT LIGHT (BR9644-11) IF NEEDED. REMOVED AND REPLACED SEAT 25C SEATSDR CALA2026060116688Lamp · inoperativeFLIGHT READINESS CHECKLIST (ADDED BY EC0500-01365) PROCEDURE - EMERGENCY PROXIMITY LIGHTS INOP AT SEATS ROWS 12, 15 AND 21. TROUBLESHOT EMERGENCY LIGHTS SYSTEM PER FIM 33-50 TASK 801. REF WDM 33-51-21-909, ROWS 12, 15 AND 21 ARE POWERED BY BATTERY PACK M1669. SDR CALA2026052716564Adiru · faultedON ROTATION R IRS FAULT LIGHT ILLUMINATED. DOES NOT EXTINGUISH COMPLETED ADIRU BITE FIM TASK 34-21 TASK 801, CURRENT STATUS R ADIRU, REPLACED RT ADIRU, OPS CHECK GOOD MM 34-21-00SDR CALA2026061217045Web · corrodedAFT CARGO COMPARTMENT MAIN SILL WEB MULTIPLER POINTS OF CORROSION, REMOVED AND REPLACED NEW MAIN SILL WEB AFT CARGO COMPARTMENT IAW SRM 51-40-02-0G-0.SDR CALA2026052116432Intercostal · corrodedDURING REMOTION OF AFT CARGO SIDEWALLS PANELS, FOUND CORROSION ON INTERCOSTAL BTW BS 747 - 767, RBL 21, REQUIRES REPLACEMENT. REMOVED, LOCATED, DRILLED, APPLIED ALODINE, PRIMER AND INSTALLED NEW INTERCOSTAL IAW SRM 51-40-02-0G-0, 51-40-05-0G-0, AMM 51-21-4SDR CALA2026052016417Light Sys · faultedDURING EMERGENCY LIGHT OPS CHECK, FOUND LOWER STOW BIN AISLE LIGHT AT SEAT ROW 23 ABC INOP. SUPPORT TASK NSA EMX NR 00012. REMOVED, REPLACED, AND OPS CHECKED EMERGENCY LIGHT LAMP AT LOWER STOW BIN AISLE SEAT ROW 23ABC IAW 33-51-03-960-801. OPS CHECK GOOD.SDR CALA2026052016399Battery Pack · no testEMEGENCY POWER PACK, M1672, FAILED EMERGENCY LIGHTING FUNCTIONAL CHECK. REMOVED AND INSTALLED NEW BATTERY PACK (M1672) IAW AMM 31-51-06-960-805 AND INSTALL TESTED GOOD.SDR CALA2026052016397Battery Pack · no testEMERGENCY POWER PACK, M1673, FAILS EMERGENCY LIGHTING FUNCTIONAL CHECK. REMOVED AND INSTALLED NEW BATTERY PACK (M1673) IAW B737 AMM 31-51-06-960-805 AND INSTALL TEST GOOD.SDR CALA2026052016395Battery Pack · no testEMEGENCY POWER PACK, M1669, FAILS EMERGENCY LIGHTING FUNCTIONAL CHECK. REMOVED AND REPLACED BATTERY PACK IN POSITION M1669 IAW B737 AMM 33-51-06-960-805. TEST PASS GOOD.SDR CALA2026052016393Battery Pack · faultedEMERGENCY BATTERY PACK, M1676, FAILS EMERGENCY LIGHTING FUNCTIONAL CHECK. REMOVED AND REPLACED BATTERY PACK M1676 IAW AMM 33-51-06-960-805. TEST PASSED GOOD.SDR CALA2026082718980Pressure Web · crackedCRACK FOUND AT VERTICAL PRESSURE WEB BETWEEN RBL 40.00 AND RBL 45.64. CRACK LENGTH 1". (REF AAR N/R 100012821)CUT AND REMOVED DAMAGED PART ,FABRICATED AND INSTALLED NEW REPAIR PART , [1] REPAIR WEB, NEW [2] , NEW [3] FILLERDOUBLER, [5] SHIM, AT STA 663 FROM RBSDR CALA2026052116428Shield · corrodedAFT CARGO COMAPRTMENT; RT FLOOR STRUCTURE SHIELD BETWEEN BS 767 AND 787, STRINGER 24R. FOUND EXCESSIVE CORROSION REQUIRING REPLACEMENT. R & R THE SHIELD IAW SRM 51-40-02-0G-0, SRM 51-40-05-0G-0, AND 51-40-08-0G-0.SDR CALA2026051816342Unknown · odorBURNING RUBBER ODOR IN AFT GALLEY REF MM 05-51-26-800-801-C1 PERFORMED INSPECTION IN THE CABIN LAVS AND GALLEYS NEED TO START WITH STEP C (2)(E) ITEM (10) START ENGINE RUNS. NOTE COULD NOT SMELL ANY BURNT SMELL OR RUBBER SMELL OR ELECTRICAL SMELL AIRCRAFT WASSDR CALA2026051816340Fseu · faultyFLAP ASYMMETRY WHILE EXTENDING. LEFT FLAP STAYED AT 0. ACCOMPLISHED FSEU BITE, RESULTS MAINT MSG 27-81218 INTERMITENT. CYCLED FLAPS TWICE NO FAULTS NOTED. REF FIM 27-88 TASK 805. REMOVED AND REPLACED FSEU IN REF TO AMM 27-51-01. OPS CHECK GOOD. NO EXISTING SDR CALA2026051716303Channel · corrodedDURING REMOVAL OF SIDEWALLS PANELS ON AFT CARGO, FOUND MULTIPLES POINTS OF CORROSION ON Z-CHANNEL, LH SIDE BTW STA 727 TO 847, REQUIRE REPAIR. (REF. AAR NR 1000079768). REMOVED AND REPLACED DAMAGED ZEE CHANNEL AT AFT CARGO COMPARMENT LH SIDE BTW STA 747 TO 847SDR CALA2026051516295Transmitter · faultedNOTICED AT CRUISE THAT R FLAP TE IND HALF WAY BETWEEN 0 AND 1.NO LE OR TE FLAP LIGHTS ON DEBRIEF INBOUND FLT CREW, STATED FLAP HANDLE UP, AT CRUIZE THE TRAILING EDGE FLAP INDICATOR SHOW A SPLIT SEE PHOTOS. AT GATE CYCLE FLAPS WITH HYDRAULICS NEEDLES WERE MARRYSDR CALA2026051416248Channel · corrodedDURING REMOVAL OF AFT CARGO SIDEWALLS PANELS, FOUND CORROSION ON RH Z-CHANNEL BTW BS 727 TO 767, REQUIRE REPAIR. REMOVED, FABRICATED AND INSTALLED RT CHANEL BTW STA 727 TO 767 AT AFT CARGO COMPARTMENT IAW SRM 53-00-53-2R-6 AND SRM 51-40-02-0G-0, SRM 51-40-05SDR CALA2026051416242Latch · brokenROW 23 ABC PSU CAME DOWN. RESECURED FOUND AFT LATCH BROKEN ON PSU AT LOCATION 23ABC. PSU WILL NOT LOCK SCURELY IN POSTION. REPLACED BROKEN LACTH (AFT) POSITION ON PSU AND SECURE. AITCRAFT OKAY TO CONTINUE.SDR CALA2026051416226Light · inoperativeRT OVERWING EMERGENCY DOOR WINDOW LIGHT INOP REMOVED AND REPLACED RH OVERWING EMERGENCY EXIT DOOR WINDOW LIGHT IN REF TO AMM 33-21-00-960-806. OPS CHECK GOODSDR CALA2026051116161Sensor · faultedNOSE GEAR RED AND GREEN LIGHT ILUMINTED NLG RED AND GREEN LIGHTS SHOWING IN AIR WITH GEAR HANDLE AT OFF AND UP POSITIONS. PSEU BITE SHOWS 3 FAULTS. NOSE DN DISAGREE 32-61013. NOSE DWN A FAULT 32-61004. PERFORMED GV OF NLG AREA UPON ARRIVAL TO GATE IAW AMM 32SDR CALA2026050716051Light · brokenEMERGENCY LIGHTS - OPERATIONAL CHECK EMERGENCY LIGHTS OPERATIONAL CHECK - ROW 10 AISLE EMERGENCY LIGHT FOUND BROKEN REPLACED AISLE EMERGENCY LIGHT. OPS CHECK GOODSDR CALA2026082718974Skin · damagedDENT FROM BIRD STRIKE FWD OF LEFT AOA SKIN IAW SRM 53-10-01-1, 2024 T-3 .071 CHEM MILLED TO .040 IN POCKETS REF FIG 5. BLENDED DAMAGED AREA AND REMOVED PAINT REF SRM 53-00-01-1A-1 FIG103. NEEDS NDT PART 6 SRM 51-00-00 PROCEDURE 23. ACCOMPLISHED HFEC IAW 737 NDSDR CALA2026050415950Elec Connector · disconnectedEMERGENCY LIGHTS - OPERATIONAL CHECK EMERGENCY LIGHTS OPERATIONAL CHECK - OVERHEAD EMERGENCY EXIT LIGHT IN CEILING ABOVE ROW 24/25 IS INOP FOUND PLUG DISCONNECTED,SECURED PLUG ,ACP OPS CHK AMM 33-51-02-720 ,OPS CHK GOODSDR CALA2026043015899Sliding Window · leakingCAPTAIN`S LEFT WINDOW AIR LEAKING SOUND IN FLTPRESSURIZED A/C AND FOUND LEAKS AT 500FT AROUND BOTTOM OF 2L SLIDING WINDOW 56-12-11. REMOVED THE WINDOW. STARTED TO INSTALL NEW 2L WINDOW WHEN WE INFORMED TO STOP THAT MOVE TEAM WAS GOING TO TAKE THE ACFT. REINSSDR CALA2026043015898Adiru · faultedHEADING FAIL ON CAPT SIDE ADIRU 1 REPORTED HEADING FAULT, TCAS REPORTED HEADING FAULT, DEU REPORTED SEVERAL ADIRU 1 FAULTS. DUE TO MULTIPLE FAILURES LINKED TO ADIRU 1 REMOVED AND REPLACED ADIRU 1. REF AMM 34-21-01. ADIRU OPS CHECK GOOD. TCAS OPS CHECK GOOD. RESDR CALA2026042915819Battery Pack · no testEMERGENCY LIGHT BATTERY PACK M1674 FAILED CAPACITY CHECK. REPLACED M1674 EMERG BATTERY, OPS CHK GOOD PER MM #33-51-06-960-805.SDR CALA2026042915814Fire Warning · false activationLAV D FIRE ALARM ACTIVE LAV BOTTLE FIRE EXTINGUISHER DID NOT A CTIVATE PER FLIGHT CREW, NO SMOKE OR ODOR NOTICED WHEN ALARM WENT OFF. FA DID NOT TRY RESETTING SMOKE ALARM SOUND. UPDATED MAA CODE FIX USING VENDOR MAA SCREEN PLEASE CONTACT TOMC BEFORE COMMENCINGSDR CALA2026042815794Adiru · failedFLIGHT CREW REPORTED TCAS FAILED INFLIGHT FLAGGED FOR SDR REF FIM 34-45 TASK 801 BITE TEST OF TCAS FOUND HDNG FAULT. REMOVED AND REPLACED ADIRU 1 IAW AMM 34-21-01. ADIRU OPS CHECKED GOOD. TCAS OPS CHECKED GOOD IAW AMM 34-45-02-700-801-C2. PERFORMED LAND VERSDR CALA2026042915815Placard · missingPDA 2 MLG SERVICING CHART IN LEFT MAIN WHEEL WELL MISSING, BROKEN OFF. INSTALLED NEW PLACARD REF SRM 51-40-02PARTS USED: 29-1122-3-0008,QTY :1SDR CALA2026050415948Lamp · inoperativeSEAT 26 C BULLNOSE EMERGENCY PATHWAY LIGHT OUT NEEDS ADDITIONAL TROUBLESHOOTING SUSPECT WIRE BUNDLE W00634 BAD , RELAMPED AND REPLACED HOUSING ASSEMBLY STILL NOT WORKING REQUEST MEL 3314A FOR AREA LIGHT INOP BULLNOSE EMERGECY LIGHT MEL 3314A NOT CORRECT MEL RESDR CALA2026042715741Slide · unraveledMCD SLIDE HAS EXCESS SLIDE MATERIAL EXPOSED. RESTOWED EXCESS GIRT BAR MATERIAL INTO THE VALISE REF AMM TASK 25-66-01-400-801, NO DEFECTS NOTED.SDR CALA2026042315658Ring · crackedESCAPE SLIDE PACK INSTALLATION - GIRT BAR STOP RING IS CRACKED IN MULTIPLE PLACES. REMOVED AND REPLACED LA ESCAPE SLIDE STOP RELEASE PER AMM 25-66-01 VERIFIED RII REQUIRMENTS. ALL WORK COMPLETESDR CALA2026083119110Skin · crackedCRACK FOUND AT RT HORIZONTAL STAB LOWER SKIN AT HSS 101.90, 13 INCHES FROM REAR SPAR , INBD ROW. CRACK LENGTH 1". ACCOMPLISHED REPAIR ON THE RT HORZ STAB LOWER SKIN IAW SRM 55-10-01-2R-11.SDR CALA2026041615407Angle · corrodedAPU COMPARTMENT LEFT SIDE LOWER FRAME HAS LIGHT CORROSION IN SEVERAL SPOTS. ACCOMPLISHED ESFR FORM AS PER GMM 04-20-05. REMOVED AND REPLACED APU COMPARTMENT LEFT SIDE LOWER FRAME PER SRM 51-40-02-0G-0 AND DWG 148A8600.
Back to Boeing 737-724