What was found
OPEN ENG LATCHES ON NR 2 ENGINE. CONTACTED ENGINEERING AND APPLYING ECRA 5452-01160. TERMINATING ACTION TO BE COMPLETED IN 5 DAYS.111 LATCH OF CONCERN IS INBD AFT LATCH, SECURED REF ECRA5452-01160. INTERIM REPAIR MADE TO #2 ENGINE PYLON THUMBNAIL FAIRING LATCH PER ECRA 5452-01160 PART 1. ACCOMPLISH INSPECTION REQUIREMENTS PER PART 2 DAILY AND ACCOMPLISH A PERMANENT REPAIR PER PART 3 WITHIN 5 DAYS. T