Boeing 737-724
Service difficulty reports · 3,423
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '737724' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '737724' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2016072900468Battery Pack · dischargedLAST 4 ROWS ON LEFT SIDE EMERGENCY AISLE LIGHTING IS INOPERATIVE. R & R EMERGENCY BATTERY PACK REF AMM 33-51-06-9 60-805. LOCATED AT RT SIDE OVERHEAD AFT GALLEY CEILING. OPS CHECK GOOD.SDR CALA2016072900470Light · inoperativeEMERGENCY LIGHTS NOT ARMED, LIGHT INDICATOR BULBS BURNED OUT. RELAMPED, CKS GOOD.SDR CALA2016072800465Lamp · inoperativeAFT GALLEY EMERGENCY LIGHT INOPERATIVE. REPLACED THE LIGHT, OPS CHECKED OKSDR CALA2016070600412Smoke Detector · false activationSMOKE ALARM ACTIVATED IN FLIGHT FIRST CLASS, PULLED CIRCUIT BREAKER IAW CHECK LIST AND RESET. ALARM REACTIVATED, NO SMOKE OR HEAT DETECTED.SDR CALA2016070500407Skin · damagedSKIN BURN IN FIELD AT STA 817, 4.5" BETWEEN STRINGERS S-3R TO S-4R. ACCOMPLISHED SKIN REPAIR AT STA 817 IAW EC/RA 5331-02085. ACCOMPLISH INSP REQUIREMENTS ON OR BEFORE THE ACFT REACHING 50,000 TT AIRFRAME FLT CYCLES.SDR CALA2016062700386Skin · damagedLIGHTNING STRIKE DAMAGE OUT LIMITS FROM STA 807 TO STA 847, STR 25L TO STR 27R. REPAIRED IAW ECRA 5331-02109, INITIATED A DIP IAW SAME ECRA PART 1 STEP D-9. ACCOMPLISH A PERMANENT REPAIR ON OR BEFORE JUNE 24, 2018. PLANNING TO CONTACT ENGINEERING AFTER APRISDR CALA2016062700383Skin · damagedLIGHTNING STRIKE FOUND AT STA 471, STR 23L TO STR 24L. ACCOMPLISHED REPAIR OF FUSELAGE SKIN AT STA 471, STR 23L TO STR 24L IAW EC/RA 5331-02104.SDR CALA2016062700382Skin · crackedREF AD 2013-19-04, EA 5310-05878, REV D, OP-5 STE 7.1 LOWER FUSELAGE STA 540, STR-22, AMP 23, RT SIDE THERE IS A CRACK INDICATION IN THE SKIN AT THE 2 PLACES IN THE FWD FASTENER .2500 HOLE JUST BELOW THE DRAG LINK COMMON TO THE CHORD AREA. FUSELAGE AT STA 540SDR CALA2016062700381Skin · crackedPERFORMED HFEC IAW NDT PART 6, 51-00-00 PROCEDURE 23 AND EA 530-05878, REV D, STEP 4, 2. FOUND CRACKS ON RT SKIN, STA 540 BETWEEN STR S-22R AND S-23R. CRACK NOTED AT FWD ROW, 2ND HOLE AND CRACK NOTED ON AFT ROW 2ND HOLE. REF FIG 2, SHEET 2 OF 2 OF THE EA NOSDR CALA2016060600350Bulb · inoperativeR1 EXTERIOR LIGHT INOPERATIVE. R & R THE BULB IAW AMM 33-51-04. OPS CHECKED GOOD IAW AMM 33-51-04-710-0 02.SDR CALA2016060600349Battery Pack · inoperativeL1 OVERHEAD EMERGENCY LIGHT INOPERATIVE. R & R BATTERY PACKS AT POS M01672, M01673, M01674 & M01675 IAW AMM 33-51-06. PERFORMED EMERGENCY LIGHTS OPERATIONS CHECK IAW AMM 33-51-00, FOUND NORMAL AMM 33-51-00- 720-003. OPERATIONS TESTED GOOD IAW AMM 33-51-710-SDR CALA2016060600346Skin · damagedFOUND DAMAGE ON FUSELAGE AT APPROX BS 240, BETWEEN STRINGER 19L & 20L. REMOVED DAMAGE. PERFORMED SRM 53-00-01 REPAIR 3.SDR CALA2016060600345Skin · not reportedACCOMPLISHED REPAIR TO EXTERNAL POWER FUSELAGE SKIN AFT SIDE OF POWER RECEPTACLE, TWO EACH DAMAGED HOLES IAW ECRA 5330-05715.SDR CALA2016060200341Skin · crackedRIGHT LOWER HORIZONTAL STAB SHOWS CRACK AT STATION 138.70, INBD OF DRAIN HOLE, APPROX 0.75 INCHES LONG, VERIFIED HFEC. REPAIRED IAW SRM 55-10-01 REPAIR 11.SDR CALA2016050600284Battery Pack · weakEMERGENCY BATTERY PACK AT STATION 727C+13 LT WEAK. R & R WEAK BATTERY PACK AT STATION 727C+13. OPERATIONS CHECKED GOOD IAW AMM 33-51-06-960-805 ON PART D -D717-01-100, SN 178037.SDR CALA2016050200283Engine · malfunctionedAT FL380 LT ENG LOST 50% POWER & SLIGHT VIBRATION OCCURRED, REDUCED TO IDLE. NO FURTHER VIBRATION OR ABNORMAL INDICATIONS, DECIDED TO OPERATE AT IDLE DECLARED EMER & DIVERTED. SUSPECT NR 4 BEARING FAILURE ON NR 1 ENG. R & R NR 1 ENG IAW WC 29-7100-1-0900, &SDR CALA2016050200275Battery Pack · dischargedEMERGENCY LIGHT AT 8 ABC OVERHEAD BIN INOPERATIVE. R & R BATTERY PACK AT STATION 603 M1668. OPERATIONS CHECKED GOOD.SDR CALA2016050200274Battery Pack · weakLEFT AFT EMER LIGHT BATTERY PACK WEAK. R & R LT AFT EMER BATTERY PACK M1673 & OPERATIONS CHECKED GOOD ALL IAW AMM 33-51-00 PN AD-D717-01-100.SDR CALA2016050200273Battery Pack · dischargedEMERGENCY LIGHTS INOPERATIVE AT LT OVERWING EXIT. R & R BATTERY PACK AT STATION 603 M1668. OPERATIONS CHECKED GOOD ALL IAW AMM 33-51-13 PN AD-D717-01-100.SDR CALA2016050200272Battery Pack · defectiveRIGHT AFT EMER BATTERY PACK NOT CHARGING. R & R RT EMER BATTERY PACK M1672 & OPERATIONS CHECKED GOOD ALL IAW AMM 33-51-00 PN AD-D717-01-100.SDR CALA2016050200271Light · inoperativeEPL IS INOPERATIVE ON OVERHEAD STOW BIN AT ROWS 11ABC. RELAMPED LIGHT AT OVERHEAD STOW BIN 11ABC & OPERATIONS CHECKED GOOD ALL IAW AMM 33-51-00.SDR CALA2016042500248Frame · crackedIAW EA 5310-06135 OP 1. LEFT SIDE STATION 727 LOWER FRAME INSPECTION, .150 CRACK DETECTED IAW STEP 5.3. CUT OUT CRACK, INSTALLED FREEZE PLUG & COMPLETED REPAIR IAW STEPS 1- 2 OF EA 5310-06135.SDR CALA2016041100219Skin · scratchedSCRATCH IN FUSELAGE SKIN AT AFT CARGO DOOR, AFT LOWER CORNER. FABRICATED & INSTALLED REPAIR DOUBLERS & FILLERS TO AFT CARGO DOOR CUT OUT IAW SRM 53-00-01 REPAIR 21 DETAIL 2 & SRM 51-40-02. ALODINED & PRIMED IAW SRM 51-2 0-01. TOP COATED AREA IAW AMM 51-21-9SDR CALA2016041100216Ground Wire · detachedL1 UPPER DOOR SURROUND EMER EXIT LIGHT GND WIRE IS UNATTACHED ON LIGHT ASSEMBLY. R & R UPPER DOOR SURROUND EMER LIGHT ASSEMBLY IAW AMM 33-51-01-900-802. OPERATIONS CHECKED GOOD.SDR CALA2016040400210Light · inoperativeSUPPORT TASK RT OVERWING EMER LIGHT INOPERATIVE. RELAMPED RT OVERWING EMER LIGHT. OPERATIONS CHECKED GOOD IAW AMM 33-51-04-960-801.SDR CALA2016040400209Light · inoperativeSUPPORT TASK EXTERIOR EMER LIGHT AT L2 DOOR INOPERATIVE. REMOVED & RELAMPED EXTERIOR EMER LIGHT IAW AMM 33-51-04-960-801.SDR CALA2016040400206Power Supply · inoperativeSUPPORT TASK EEPL LIGHTS INOPERATIVE FROM ROWS 22 - 28 LT. R & R EMER POWER SUPPLY & TESTED GOOD IAW AMM 33-51-060 POSITON M1670. MFG PAGE STATION 7 27C+13, WL 212, BL L068 SN 12161 & PN D717-02-030.SDR CALA2016033100205Skin · dentedSUPPORT UPON FURTHER INVESTIGATION OF NR'S 6453318 & 6453375, DENTS FOUND TO EXCEED LIMITS IAW SRM 53-00-01 PAGE 106 TABLE 102. PERFORMED SKIN REPAIR, BETWEEN STRINGER 13L & 17L AFT FS 1016 IAW SRM 53-80-01 REPAIR 2 & ECRA 5330-05656 REV ORIGINAL.SDR CALA2016033100198Light · inoperativeSUPPORT TASK RT FWD OVERWING EXIT ON UPPER PART OF DOOR IS INOPERATIVE, INBD. RELAMPED RT FWD OVERWING EXIT ON UPPER PART OF DOOR & OPERATIONAL CHECKED GOOD IAW AMM 33-51-01-960-801. LOCATION L 00751, STATION 628, WL 270 & RBL 6.SDR CALA2016032900195Structure · damagedOUTBOARD CHORD IS DAMAGED AT HIGH PRESS PNEUMATIC ACCESS DOOR. OTBD LATCH POINT REPAIRED IAW ECRA 5351-01122 SEE 008 FOR WORK DESCRIPTION.SDR CALA2016032800189Battery Pack · dischargedTHE FOLLOWING 1ST CLASS EEPL LIGHTS ARE INOPERATIVE, INBOUND. RT FWD 2 BULLNOSE LIGHTS, CTR FWD EXIT SIGN ON LIFE RAFT 1, & CEILING EXIT LIGHT. REMOVED EMER LIGHTING BATTERY PACK SN 83769, & REPLACED WITH SN 173943 FROM THE 1ST CLASS RT FWD 2 BULLNOSE IAW AMSDR CALA2016032100174Battery Pack · dischargedMAIN CABIN AT ROW 1, 3 & 8 AT OVERHEAD BINS EMER LIGHT INOPERATIVE. R & R M1675 BATTERY PACK. R & R M1668 BATTERY CHARGER & BATTERY PACK IAW AMM 33-51- 06-960-806. R & R LIGHT ASSEMBLY LENSES AT SEAT ROWS 1 & 8 IAW AMM 33-51-03-960-802. EMER LIGHT OPERATIOSDR CALA2016031700169Light · inoperativeSUPPORT TASK NR 2 SERVICE CHECK STEP 17. SEAT ROW 32, LT SIDE OVERHEAD BIN EMER AISLE LIGHT DOES NOT ILLUMINATE. REPLACED ROW 32 OVERHEAD BIN EMER AISLE LIGHT LAMP IAW AMM 33-51-03-960-801. OPERATIONAL CHECK PASSED.SDR CALA2016031100159Control Box · failedFLIGHT DECK DOOR FAILED TO REMAIN LOCKED IN FLIGHT. FOUND ELEC CONTROL BOX FAILED. REPLACED THE SAME IAW TASK 52-52- 02-800-801C12. OPERATIONS CHECKED NORMAL.SDR CALA2016031100157Skin · crackedSUPPORT FUSELAGE SKIN CRACKED AT FASTENER HOLE, BS 540, 2ND FASTENER BELOW STRINGER 22R AT AFT EDGE. REPAIRED SKIN CRACK IAW EA 5310-05878 REV C.SDR CALA2016022200123Windshield · crackedPASSING 33,000 FT, WINDSHIELD L1 OUTER PANE CRACKED DUE TO OVERHEAT, OUTER PANE ONLY. REPLACED L1 WINDSHIELD IAW AMM 56-11-11 & LT WINDOW HEAT CONTROLLER IAW AMM 30-41-11. ALL TESTED OK.SDR CALA2016020100083Battery Pack · dischargedL2 EMER EXIT LIGHT, EXTERIOR, INOPERATIVE. R & R M1673 BATTERY PACK AMM 33-51-06. REF TO NR 4903047.SDR CALA2016020100082Battery Pack · dischargedBULLNOSE EMER EXIT LIGHTS LT ROWS 23 - 32 INOPERATIVE. R & R M1673 BATTERY PACK AMM 33-51-06. REF TO NR 4903047.SDR CALA2016020100081Battery Pack · dischargedBULLNOSE EMER EXIT LIGHT RT ROW 30 INOPERATIVE. R & R M1673 BATTERY PACK AMM 33-51-06.SDR CALA2016020100079Skin · damagedDAMAGE TO FUSELAGE SKIN, FWD OF C1 DOOR, AT APPROX STATION 440, STRINGER 20R. REMOVED DAMAGED AREA & INSTALLED REPAIR IAW ECRA 5330-05553 & ECRA 5330-05555. REF LOG PAGE 8573892 FOR DIP STATUS.SDR CALA2016020100077Door Frame · crackedR1 DOOR FRAME BELOW THE BOX HANDLE MECHANISM, BOLT ATTACHMENT HOLE, JUST AFT OF DOOR TORQUE TUBE HAS A CRACK ALTER ACFT NOSE. R & R BEAM IAW SRM 51-40-02 & DWGS 141A6535 & 141A6516.SDR CALA2016012700071Battery Pack · dischargedEMERGENCY EXIT AISLE LIGHTS INOPERATIVE, ROWS 22 ABC - 28 ABC. R & R M1670 BATTERY PACK & POWER SUPPLY IAW MM 33-51-06. OPERATIONS CHECKED GOOD. OK FOR SERVICE.SDR CALA2016012500068Skin · damagedNICK WAS FOUND ON INTERNAL SURFACE OF FWD CARGO COMPARTMENT DOOR CUTOUT, FWD LOWER CORNER, STATION 442, RBL 35 8=0.4" X 0 .4". PERFORMED REPAIR IAW ECRA 5311-01671 & 737EN-53-024 0, INITIATED A DIP THAT STATES THE REPAIR IAW ECRA 5311-016 71 HAS ONLY FIRST STSDR CALA2016011200048Beam · crackedR1 DOOR CRACKED AT RADIUS FROM HORIZONTAL BEAM TO VERTICAL FLANGE, ABOVE TORQUE BOX AT FWD INBD TORQUE BOX MOUNT BOLT, VIEW WITH DOOR CLOSED, BELOW WINDOW. REPAIRED R1 DOOR HORIZONTAL BEAM, PN 141A6536-15, IAW ECRA 5 210-02684 STEP 13. R & R THE REPAIRED R1,SDR CALA2016011100045Skin · crackedFUSELAGE SKIN HAS A CRACK AT TWO FASTENERS, APPROX 1/2 INCH FROM FWD OF STATION 540 SKIN EDGE, BETWEEN STRINGERS 22R & 23R. FABRICATED & INSTALLED REPAIR PARTS IAW ECRA 5310-06725 & EA 5310-05878 REV C OP 05.SDR CALA2016011100043Skin · crackedFUSELAGE SKIN HAS A CRACK APPROX 1/2 FWD OF STATION 540, SKIN AFT EDGE AT FASTENER HOLE, LOCATED BETWEEN STRINGERS 22L & 23L. FABRICATED & INSTALLED REPAIR PARTS IAW ECRA 5310-06727 & EA 5310-05878 REV C OP 04.SDR CALA2016010800033Light · inoperativeR2 DOOR EMER EXIT LIGHT NOT WORKING AT LIGHT BAR AFT LIGHT. REPLACED LAMP AT R2 DOOR EMER EXIT LIGHT IAW AMM 33-51-01. OPERATIONS CHECKED GOOD.SDR CALA2016010800032Battery Pack · dischargedEMERGENCY BULLNOSE LIGHTS INOPERATIVE AT SEATS 12 & 21 RT. R & R BATTERY PACK AT STATION 603, WL 212, RBL 67 IAW AMM 35-51-06. OPERATIONS CHECKED GOOD. PN OFF AD-D717-01-100, SN 63546.SDR CALA2016010800031Battery Pack · dischargedEMERGENCY PATH LIGHTS ON SEATS 12 - 21 LT ARE INOPERATIVE. R & R BATTERY PACK AT STATION 603, WL 212, RBL 67 IAW AMM 35-51-06. OPERATIONS CHECKED GOOD. PN OFF AD-D717-01-100, SN 63546.SDR CALA2016010800027Battery Pack · dischargedSUPPORT TASK, EMER LIGHTS INOPERATIVE AT R1 DOOR & FWD LOWERED CEILING PANEL. R & R EMER LIGHT M1675 BATTERY PACK. OPERATIONS CHECKED GOOD IAW AMM 33-51-06. BATTERY PACK MANUFACTURER PN AD-D717-01-100, SN 83766, WDM 33-51-12, BS 322, WL 291, LBL 7, M1675.
Back to Boeing 737-724