What was found
EMERGENCY LIGHTS INOPERATIVE AT LT OVERWING EXIT. R & R BATTERY PACK AT STATION 603 M1668. OPERATIONS CHECKED GOOD ALL IAW AMM 33-51-13 PN AD-D717-01-100.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
EMERGENCY LIGHTS INOPERATIVE AT LT OVERWING EXIT. R & R BATTERY PACK AT STATION 603 M1668. OPERATIONS CHECKED GOOD ALL IAW AMM 33-51-13 PN AD-D717-01-100.