Boeing 737-724
Service difficulty reports · 3,423
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '737724' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '737724' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2015011600048Splice · crackedWHILE ACCOMPLISHING EA 5320-02076 REV E OP 04, MAIN CABIN SEAT TRACK SPLICE LOCATION 727B RBL 24.75 HAS A CRACK ON THE OTBD AFT HOLE COMMON TO SPLICE STRAP. THE HOLES IN THE SEAT TRACK FLANGES WILL NOT MEET THE EDGE DISTANCE REQUIREMENTS IAW THE EA. TRIMMED SDR CALA2015011300043Hmu · unserviceableNUMBER 2 ENG SURGE, CRUISE FL 220, ENGS WERE RUNNING AROUND 74% N1 NR 2 ENG SURGED UNCONTROLLED AT 20 TO 305 TO 40%. BROUGHT NR 2 ENG BACK UNDER 60% & STABILIZED. STAYED UNDER 60% UNTIL LANDING, RT ENG CONTROL LIGHT ILLUMINATED ON GND. TROUBLE SHOT IAW FIM SDR CALA2015010900021Fuse · failedRIGHT SIDE OVERWING ESCAPE GND ILLUMINATION LIGHT INOPERATIVE. REPLACED EMER EXIT LIGHT BATTERY PACK M1670 FUSE & OPERATIONS CHECKS GOOD IAW AMM 33-51-06-960-804.SDR CALA2015010600010Seat Track · crackedWHILE ACCOMPLISHING EA 5320-02076 REV E OP 3 THE MAIN CABIN SEAT TRACK SPLICE LOCATION STATION 727B, LBL 45.50 HAS CRACKS ON THE SEAT TRACK HOLES COMMON TO THE SPLICE STRAP. THE SPLICE STRAP ALSO HAS CRACKED HOLES & THE REPAIR IAW EA DOES NOT ALLOW FOR PROPERSDR CALA2015010600009Seat Track · crackedWHILE ACCOMPLISHING EA 5320-02076 REV E OP 3 THE MAIN CABIN SEAT TRACK SPLICE LOCATION STATION 727B, RBL 24.75 HAS CRACKS ON THE SEAT TRACK HOLES COMMON TO THE SPLICE STRAP. THE SPLICE STRAP ALSO HAS CRACKED HOLES & THE REPAIR IAW THE EA DOES NOT ALLOW FOR PRSDR CALA2015010600008Seat Track · crackedWHILE ACCOMPLISHING EA 5320-02076 REV E OP 3 THE MAIN CABIN SEAT TRACKS SLICE LOCATION STATION 727B, RBL45.50 HAS CRACKS ON THE SEAT TRACK HOLES COMMON TO THE SPLICE STRAP. THE SPLICE STRAP ALSO HAS CRACKED HOLES & THE REPAIR IAW THE EA DOES NOT ALLOW FOR PROSDR CALA2015010600013Skin · wornUPPER FUSELAGE EXTERIOR SKIN IS WORN AT STATION 857 LBL-2. INSTALLED REPAIR DOUBLE AT FS 847 - 867 IAW ECRA 5330-050 03 PART 1. ACCOMPLISH AN INSPECTION OF CROWN SKIN REPAIR IAW ECRA 5330-05003 IAW PART 2 ON OR BEFORE 50,000 TOTAL ACFT FLIGHT CYCLES. CONTACSDR CALA2015010600011Seat Track · crackedWHILE ACCOMPLISHING EA 5230-02076 REV E OP 3, THE MAIN CABIN SEAT TRACK SPLICE LOCATION STATION 727B, LBL 24.75 HAS CRACKS ON THE SEAT TRACK HOLES COMMON TO THE SPLICE STRAP. THE REPAIR IAW THE EA DOES NOT ALLOW FOR PROPER EDGE DISTANCE OF THE 4 FASTENER HOLESDR CALA2014123001550Skin · crackedWHEN PREFORMED C SCAN EDDY CURRENT INSPECTION ON LT HORIZONTAL STAB LOWER SKIN FOUND CRACK INDICATION ON STATION SS101.90. CUT OUT DAMAGE, FABRICATED & INSTALLED REPAIR DOUBLER & FILLER ON LT HORIZONTAL STAB LOWER SKIN AT STATION SS101.90.SDR CALA2014121701522Air Data Module · defectiveDURING HIGH ALTITUDE CLIMB 35,000 IAS DISAGREE LIGHTS ILLUMINATED. CAPTAIN & FIRST OFFICER OVER SPEED CLACKER INITIATED. BOTH EEC SWITCHED TO ALT MODE WITH MASTER CAUTION LIGHT ILLUMINATED. STANDBY IAS MORE CLOSELY MATCHED CAPTAINS IAS. ALL APPLICABLE QRH SDR CALA2014120801491Door · malfunctionedREF LP 8007264 8 DEF O2 FAILED TO OPEN. REF LP 8007283 FOR AUTO & MANUAL DEPLOY O2 AT SEATS 8 DEF. OPERATIONS CHECKED GOOD.SDR CALA2014120201489Canister · unsecureDOOR 2L JUMP SEAT O2 CANISTERS FELL ON THE FLOOR, NOT ATTACHED TO ACFT DOOR 1L JUMP SEAT O2 DOOR FAILED TO OPEN. REF LOG 8 007269 FOR L1 R & R L2 & R2 JUMP SEAT O2 CANISTERS & REPACKED MASK IAW AMM 35-22-11-401 & 35-22-31-00-804-0-01. DOOR 1L REF LP 8007269 SDR CALA2014120201488Door · malfunctioned7 ABC, 8 DEF O2 FAILED TO OPEN. REF LP 8007270 FOR 8 DEF. REF LP 8007283 FOR AUTO & MANUAL DEPLOY. O2 DOOR AT 7 ABC & 8 DEF OPERATIONS CHECKED GOOD.SDR CALA2014120201487Door · malfunctionedREF LOG PAGE 8007263 DOOR L1 O2 DOOR FAILED TO OPEN AT JUMP SEAT. REPACKED FLIGHT ATTENDANT O2 MASK AT DOOR L1 MM-35-22-31-000-804-0-01.SDR CALA2014120201486Controller · failedRAPID DECOMPRESSION OF CABIN AT FL 340. CABIN APPROACHED APPROX 20,000 FT BEFORE IT WAS ARRESTED. NO DOOR LIGHTS. REF FOLLOWING LP FOR PARTS REPLACED. LP 8007273, 8007274, 8007275, 8007278 & 8007268. COMPONENTS REPLACED, BOTH PRESS CONTROLLERS, ONE SHOWEDSDR CALA2014120201490Door · malfunctioned22 DEF O2 MASKS DID NOT DEPLOY. REF LP 8007264 FOR AUTO & MANUAL DEPLOY O2 DOOR AT 22 DEF. OPERATIONS CHECKED GOOD.SDR CALA2014112501476Seat Track · crackedWHILE ACCOMPLISHING EA 5320-02076 REV D OP 004 MAIN CABIN SEAT TRACK SPLICE LOCATION 727B RBL 45.50 HAS A CRACK ON BOTH OF THE INBD HOLES & THE OTBD AFT HOLE COMMON TO THE SPLICE STRAP. THE OTBD AFT HOLE OF THE SPLICE STRAP COMMON TO THE SEAT TRACK IS ALSO CRSDR CALA2014112501475Seat Track · crackedWHILE ACCOMPLISHING EA 5320-02076 REV D OP 004 MAIN CABIN SEAT TRACK SPLICE LOCATION 727B RBL 24.75 HAS A CRACK ON THE OTBD AFT HOLE COMMON TO THE SPLICE STRAP. THE REPAIR IAW THIS EA ALSO DOES NOT ALLOW FOR PROPER EDGE MARGIN OF THE 4 FASTENER HOLES IN THE SSDR CALA2014112501473Seat Track · crackedACCOMPLISHING EA 5320-02076 REV DOP 003 MAIN SEAT TRACK SPLICE LOCATION 727B LBL 24.75 HAS A CRACK ON THE INBD AFT HOLE COMMON TO THE SPLICE STRAP. THE REPAIR IAW THIS EA ALSO DOES NOT ALLOW FOR PROPER EDGE MARGIN OF THE 4 FASTENER HOLES IN THE SEAT TRACK. SDR CALA2014111901459Sensor · failedLEFT TE FLAP AT 0 DESCENT, RT TE FLAP BETWEEN 0 - 1 DESCENT, WHEN SELECTED ON ARRIVAL. PERFORMED FIM 27-59 TASK802 REPLACED TE FLAP SKEW NR 2 SENSOR IAW AMM 27-59-01 & PERFORMED FUNCTION TEST IAW AMM 27-59-00. OFF SN3017 ON SN 1994. ROTABLE PARTS CHANGE WASSDR CALA2014101501346Transmitter · faultyFMS INDICATION FLAPS 197 FLAPS WITH FLAP UP & INDICATION UP. ON DFCS BITE ANALOG DATA CHANNEL A FLAP VLV SHOWING INTERMITTENT FAULT, SHOWS CHANNEL A FAIL OR CROSS CHANNEL FAIL. R & R LT FLAP POSITION TRANSMITTER IAW AMM27-58-01, OPERATIONS CHECKED GOOD. PERSDR CALA2014101501343Structure · corrodedSTRUCTURE UNDER FLOOR PANEL 211AF SEVERAL AREAS LIGHT SURFACE CORROSION. INSTALLED REPAIR IAW DISPOSITION STEPS 1-19 OF ECRA 5321-015 66.SDR CALA2014100801322Skin · corrodedC2 DOOR INNER SKIN, FWD LOWER CORNER HAS CORROSION AT SNAP ATTACH POINT. TRIMMED OUT CORRODED SECTION & INSTALLED REPAIR IAW ECRA 5230-01945.SDR CALA2014100101292Battery · dischargedL1 EXTERIOR LIGHT INOPERATIVE. RELAMPED NO HELP. TROUBLE SHOT & FOUND BATTERY ON BATTERY CHARGER EQUIPMENT M1675 WEAK. R & R BATTERY, OPERATIONS CHECKED GOOD IAW AMM 33-51-06-960-8 05.SDR CALA2014100101291Power Supply · inoperativeEMERGENCY EXIT SEAT LIGHTS INOPERATIVE AT ABC ROWS 3, 7, 8, 10 & 11. R & R BATTERY POWER SUPPLY M1676 IAW AMM 33-51-0 6-960-806. OPERATIONS CHECKED GOOD. SEAT LIGHTS WORK NORMAL.SDR CALA2014091901263Slide · tornACFT LT REAR SLIDE HAS TEAR NEAR GIRT BAR. REPLACED SLIDE IAW AMM 25-66-01. ROTABLE PARTS CHANGE WAS INDICATED. TT 1647512 SN OFF 03373 SLIDE, OFF 29-2561-9-0004 3373 ON 29-2561-9-0004 3432.SDR CALA2014091801245Battery Pack · dischargedEMERGENCY LIGHTS ROW 3 TO 11 DIM DURING TEST. REPLACED BATTERY PACK MM 33-31-06. CHECKED OK SDR REQUIRED & SUBMITTED.SDR CALA2014091501240Rib · crackedLEFT HORIZONTAL STAB RIB AT STATION 92.70 HAS A CRACK AT RIB STIFFENERS 4 PLACES. ACCOMPLISHED REPAIR IAW SRM 55-10-01 REPAIR 11 CATEGORY B. INITIATE DIP TO INSPECT THRESHOLD 56,000 FLIGHT CYCLES AFTER REPAIR INSTALLATION WITH DETAILED VISUAL INSPECTION & EXSDR CALA2014091101222Circuit Breaker · poppedON APPROACH, UPON BRINGING LG LEVER DOWN WE DID NOT GET MAIN GEAR DOWN INDICATION, ALL 3 LIGHTS INOPERATIVE. ALTERNATE LG INDICATORS SHOWED 3 GREEN. UPON INSPECTION OF CB PANEL FOUND SECT 5 CB POPPED. RESET CB GOT 3 MAIN GREEN LIGHTS. CB SECT 5 P 6 - 3 F-1SDR CALA2014090801217Proximity Switch · failedON TAKEOFF FLAP RETRACTION NR 6 LED TRANSIT LIGHT STAYED ON. RAN QRH WITH ONE EXTEND TO FLAP 1 THEN RETRACT TO UP. TRANSIT LIGHT STAYED ON LANDED FLAPS 15. TROUBLE SHOT IAW FIM 27-88-00 FOUND FAULT 27-81211 SL6 PROX INBD SWITCH S1005 BAD. R & R NR 6 SLAT ISDR CALA2014082001149Shutoff Valve · faultyBALANCING FUEL LT PUMPS TURNED ON FUEL DID NOT MOVE OUT OF LT TANK, DIVERT. SUSPECT LT FUEL QTY READING INACCURATE, PLACED ON MEL. VERIFIED FUEL QTY USING ALTERNATE METHODS LT STICK NR 8 READS 5.0. REF LOG PAGE 7638228. R & R NR 1 FUEL SOV IAW AMM 28-21- 5SDR CALA2014081401114Pressure Switch · faultyAIRCRAFT DIVERTED, LT CTR FUEL PUMP LOW PRESS LIGHT. THE RT CTR FUEL PUMP IS ALREADY ON MEL. DID NOT HAVE ENOUGH FUEL TO GET TO FLL. EMER DECLARED TURNED ON LT CTR PUMP DURING FLIGHT & LOW PRESS LIGHT STAYED ON. CTR TANK HAD 4500 LBS FUEL WITHIN. CHECKED SDR CALA2014081101099Connector · damagedLEFT AFT ZONE EMER LIGHT FOUND INOPERATIVE. TROUBLESHOOTING FOUND CONNECTOR D107449 SOME PINS PUSHED BACK. CONNECTOR REPLACED & TEST CARRIED OUT NORMAL IAW WDM 33-51-11 & SWPM 20-61-11.SDR CALA2014081101090Support · corrodedMULT-06-3-0020 FWD CARGO 500D END WALL SUPPORT STRUCTURE UPPER EDGE FOUND HEAVY CORROSION AT LBL 24.75 AREA. FWD CARGO STATION 500D END WALL SUPPORT STRUCTURE UPPER RAIL CORROSION AREA REPAIRED IAW ECRA 5310-06164 REV & FORM 44.0008 ATTACHED ITEM 1-18 ACCOMPLSDR CALA2014080401067Intercostal · crackedFORWARD COMPARTMENT FLOOR STRUCTURE WET AREA INTERCOSTAL CRACKED AT FASTENER HOLE. LOCATED BETWEEN STATION 312 & 328 AT APPROX LBL-45. R & R INTERCOSTAL BETWEEN STATION 312 & 328 LBL 45 IAW SRM 51-40-02 & ECRA 5321-11524.SDR CALA2014080401075Floorbeam · crackedCABIN STATION 727B LBL 24.75 FLOORBEAM THREE EACH HOLES FOUND CRACKED REFER TO SKETCH FOR DETAIL. CRACK LENGTH 0.040 INCHES. REPAIRED IAW ECRA 5320-02290 REV.SDR CALA2014080401074Floorbeam · crackedCABIN STATION 727B LBL 45.50 FLOORBEAM THREE EACH HOLES FOUND CRACKED REFER TO SKETCH FOR DETAIL. CRACK LENGTH 0.040 INCHES. REPAIRED IAW ECRA 5320-02290 REV.SDR CALA2014080401073Floorbeam · crackedCABIN STATION 727B RBL 45.50 FLOORBEAM TWO EACH HOLES CRACKED REFER TO SKETCH FOR DETAIL. CRACK LENGTH 0.040 INCHES. REPAIRED IAW ECRA 5320-02290 REV.SDR CALA2014080401072Floorbeam · crackedCABIN STATION 727B RBL 24.75 FLOORBEAM THREE EACH HOLES FOUND CRACKED REFER TO SKETCH FOR DETAIL. CRACK LENGTH 0.040 INCHES. REPAIRED IAW ECRA 5320-02290 REV.SDR CALA2014080401071Floorbeam · crackedCABIN STATION 727B RBL 45.50 SEAT TRACK AREA. AFT HOLE FOUND CRACK AT FLOORBEAM REFER ATTACHED DWG CABIN BS 727B RBL 45.50. FLOORBEAM UPPER CHORD FASTENER HOLE CRACKED AREA, CRACK LENGTH 0.015 INCHES. REPAIRED IAW ECRA 5320-02290 REV.SDR CALA2014080401070Rib · damagedRIGHT HORIZONTAL STAB LOWER SKIN TRIM OFF & REPAIR FOR HORIZONTAL STAB RIB REPAIR ACCESS AT STAB STATION 92.7. RT HORIZONTAL STAB LOWER SKIN AT STATION 92.7 SKIN REPAIRED IAW SRM 55-10-01 REPAIR 11 FIG 204 & AFT REPAIR INSTALLED. REPEAT INSPECTION IAW SRM 55SDR CALA2014080401069Rib · damagedLEFT HORIZONTAL STAB LOWER SKIN TRIM OFF & REPAIR FOR HORIZONTAL STAB RIB REPAIR ACCESS AT STAB STATION 92.7. LT HORIZONTAL STAB LOWER SKIN AT STATION 92.7 SKIN REPAIRED IAW SRM 55-10-01 REPAIR 11 FIG 204 & AFT REPAIR INSTALLED. REPEAT INSPECTION IAW SRM 55-SDR CALA2014080101061Switch · intermittentE & E BAY DOOR LIGHT ON, ON TAKEOFF ROLL. REJECTED TAKEOFF & INITIATED REJECT AT 95 KTS TOP SPEED 100 WEIGHT 145,000. PLACED ITEM ON MEL. TROUBLE SHOT IAW WD 52-71-12. FOUND S197 ELEC ACCESS DOOR SWITCH INTERMITTENT OPEN FAULT. MEL REMAINS EXT 280422. REPSDR CALA2014080101059Battery Pack · dischargedRIGHT AFT EMER LIGHTS INOPERATIVE. R & R BATTERY PACK NEF 33-51-06-960-805. OPERATIONS TESTED GOOD.SDR CALA2014073101052Pump · failedAFTER LEVEL OFF, TAKEOFF +30 MIN B HYD SYS FAILED. FOUND HYD PUMP ON NR 2 SEIZED. R & R NR 2 ENG HYD PUMP IAW AMM 29-11-11-401. OPERATIONS & LEAK CHECKED GOOD. FLUSH & FILTER REPLACEMENT SCHEDULED.SDR CALA2014072801028Frame · crackedSUPPORT TASK CABIN RT BS 480 BETWEEN STRINGER 8 & 9 INBD HOLE OF SUPPORT BRACKET FOUND THREE EACH CRACKS AT FRAME APPROX 1/4 INCHES, 1/4 INCH & 3/16 INCHES IN LENGTH. FRAME CRACKED AREA LENGTH 0.250. REPAIRED IAW EA 5310-04716 OP 1 REV G STEP 9 FIG 3 & FORM 4SDR CALA2014072801022Frame · crackedSUPPORT TASK CABIN LT BS 827 BETWEEN STRINGER 8 & 9 INBD HOLE OF SUPPORT BRACKET FOUND TWO EACH CRACKS AT FRAME APPROX 3/16 INCH & 3/16 INCH IN LENGTH. FRAME CRACKED LENGTH 0.186. REPAIRED IAW EA 5310-04716 OP1 REV G STEP 9 FIG 3.SDR CALA2014072801021Frame · crackedSUPPORT TASK CABIN RT 400 BETWEEN STRINGER 8 & 9 INBD HOLE OF SUPPORT BRACKET FOUND TWO EACH CRACKS AT FRAME APPROX 1/4 INCH & 1/4 INCH IN LENGTH. FRAME CRACKED LENGTH 0.250 INCHES. REPAIRED IAW EA 5310-04716 OP1 REV G STEP 9 FIG 3.SDR CALA2014072801020Frame · crackedSUPPORT TASK CABIN LT BS 787 BETWEEN STRINGER 8 & 9 INBD HOLE OF SUPPORT BRACKET FOUND TWO EACH CRACKS AT FRAME APPROX 3/16 INCH & 1/4 INCH IN LENGTH. FRAME CRACKED LENGTH 0.250 INCHES. REPAIRED IAW EA 5310-04716 OP1 REV G STEP 9 FIG 3.SDR CALA2014072801019Frame · crackedSUPPORT TASK CABIN RT BS 787 BETWEEN STRINGER 8 & 9 INBD HOLE OF SUPPORT BRACKET FOUND TWO EACH CRACKS AT FRAME APPROX 3/8 INCH & 3/16 INCH IN LENGTH. FRAME REPAIRED IAW EA 5310-04716 REV G OP1 NR 9 FIG 3.
Back to Boeing 737-724