What was found
CABIN STATION 727B RBL 45.50 FLOORBEAM TWO EACH HOLES CRACKED REFER TO SKETCH FOR DETAIL. CRACK LENGTH 0.040 INCHES. REPAIRED IAW ECRA 5320-02290 REV.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CABIN STATION 727B RBL 45.50 FLOORBEAM TWO EACH HOLES CRACKED REFER TO SKETCH FOR DETAIL. CRACK LENGTH 0.040 INCHES. REPAIRED IAW ECRA 5320-02290 REV.